Skip to main content
Erschienen in: European Journal of Applied Physiology 6/2007

01.12.2007 | Original Article

Impaired exercise ventilatory mechanics with the self-contained breathing apparatus are improved with heliox

verfasst von: Scott J. Butcher, Richard L. Jones, Jonathan R. Mayne, Timothy C. Hartley, Stewart R. Petersen

Erschienen in: European Journal of Applied Physiology | Ausgabe 6/2007

Einloggen, um Zugang zu erhalten

Abstract

The effect of the self-contained breathing apparatus (SCBA) with compressed air (BA-A) on ventilatory mechanics, work of breathing (WOB), pulmonary function, and respiratory muscle fatigue, was compared with that of a low resistance breathing valve (LRV). Further, the effect of unloading the respiratory muscles with heliox with the SCBA (BA-H) was compared with BA-A and LRV. Twelve men completed three randomized exercise trials on separate days, each consisting of three 10 min bouts of stepping exercise (Bouts 1, 2, and 3) separated by a 5 min recovery. Subjects wore firefighter protective equipment including the SCBA. At rest, FEV1 and peak expiratory flow rates were lower with BA-A than with LRV, but were higher with BA-H than either with BA-A or LRV. After Bout 3, expiratory reserve volume, expiratory resistive WOB, and inspiratory elastic WOB were increased in BA-A compared to LRV but these were lower with BA-H compared to BA-A. After Bout 3, maximal inspiratory and expiratory pressures were reduced with BA-A, but not with LRV or BA-H. In summary, we found that the SCBA reduced resting pulmonary function, and increased expiratory reserve volume, work of breathing, and respiratory muscle fatigue during stepping exercise, and these changes can be reduced with the use of heliox.
Literatur
Zurück zum Zitat Aliverti A, Iandelli I, Duranti R, Cala SJ, Kayser B, Kelly S, Misuri G, Pedotti A, Scano G, Sliwinski P, Yan S, Macklem PT (2002) Respiratory muscle dynamics and control during exercise with externally imposed expiratory flow limitation. J Appl Physiol 92:1953–1963PubMed Aliverti A, Iandelli I, Duranti R, Cala SJ, Kayser B, Kelly S, Misuri G, Pedotti A, Scano G, Sliwinski P, Yan S, Macklem PT (2002) Respiratory muscle dynamics and control during exercise with externally imposed expiratory flow limitation. J Appl Physiol 92:1953–1963PubMed
Zurück zum Zitat American Thoracic Society (1995) Standardization of spirometry. Am J Respir Crit Care Med 152:1107–1136 American Thoracic Society (1995) Standardization of spirometry. Am J Respir Crit Care Med 152:1107–1136
Zurück zum Zitat Babb TG (2001) Breathing He–O2 increases ventilation but does not decrease work of breathing during exercise. Am J Respir Crit Care Med 163:1128–1134PubMed Babb TG (2001) Breathing He–O2 increases ventilation but does not decrease work of breathing during exercise. Am J Respir Crit Care Med 163:1128–1134PubMed
Zurück zum Zitat Babb TG (2002) Hyperventilation with He–O2 breathing is not decreased by superimposed external resistance. Respir Physiol Neurobiol 133:139–151PubMedCrossRef Babb TG (2002) Hyperventilation with He–O2 breathing is not decreased by superimposed external resistance. Respir Physiol Neurobiol 133:139–151PubMedCrossRef
Zurück zum Zitat Babcock MA, Pegelow DF, McClaran SR, Suman OE, Dempsey JA (1995) Contribution of diaphragmatic power output to exercise-induced diaphragm fatigue. J Appl Physiol 78:1710–1719PubMed Babcock MA, Pegelow DF, McClaran SR, Suman OE, Dempsey JA (1995) Contribution of diaphragmatic power output to exercise-induced diaphragm fatigue. J Appl Physiol 78:1710–1719PubMed
Zurück zum Zitat Black LF, Hyatt RE (1969) Maximal respiratory pressures: normal values and relationship to age and sex. Am Rev Respir Dis 99:696–702PubMed Black LF, Hyatt RE (1969) Maximal respiratory pressures: normal values and relationship to age and sex. Am Rev Respir Dis 99:696–702PubMed
Zurück zum Zitat Butcher SJ, Jones RL, Eves ND, Petersen SR (2006) Work of breathing is increased during exercise with the self-contained breathing apparatus regulator. Appl Physiol Nutr Metab 31:693–701PubMedCrossRef Butcher SJ, Jones RL, Eves ND, Petersen SR (2006) Work of breathing is increased during exercise with the self-contained breathing apparatus regulator. Appl Physiol Nutr Metab 31:693–701PubMedCrossRef
Zurück zum Zitat Bygrave S, Legg SJ, Myers S, Llewellyn M (2004) Effect of backpack fit on lung function. Ergonomics 26:324–329 Bygrave S, Legg SJ, Myers S, Llewellyn M (2004) Effect of backpack fit on lung function. Ergonomics 26:324–329
Zurück zum Zitat Coates AL, Desmond KJ, Demizio D, Allen P, Beaudry PH (1988) Sources of error in flow–volume curves: effect of expired volume measured at the mouth vs that measured in a body plethysmograph. Chest 94:976–982PubMed Coates AL, Desmond KJ, Demizio D, Allen P, Beaudry PH (1988) Sources of error in flow–volume curves: effect of expired volume measured at the mouth vs that measured in a body plethysmograph. Chest 94:976–982PubMed
Zurück zum Zitat Crapo RO, Morris AH, Gardner RM (1981) Reference spirometric values using techniques and equipment that meet ATS recommendations. Am Rev Respir Dis 123:659–664PubMed Crapo RO, Morris AH, Gardner RM (1981) Reference spirometric values using techniques and equipment that meet ATS recommendations. Am Rev Respir Dis 123:659–664PubMed
Zurück zum Zitat Dreger RW, Jones RL, Petersen SR (2006) Effects of the self-contained breathing apparatus and fire protective clothing on maximal oxygen uptake. Ergonomics 49:911–920PubMedCrossRef Dreger RW, Jones RL, Petersen SR (2006) Effects of the self-contained breathing apparatus and fire protective clothing on maximal oxygen uptake. Ergonomics 49:911–920PubMedCrossRef
Zurück zum Zitat Eves ND, Petersen SR, Jones RL (2002) Hyperoxia improves maximal exercise with the self-contained breathing apparatus (SCBA). Ergonomics 45:829–839PubMedCrossRef Eves ND, Petersen SR, Jones RL (2002) Hyperoxia improves maximal exercise with the self-contained breathing apparatus (SCBA). Ergonomics 45:829–839PubMedCrossRef
Zurück zum Zitat Eves ND, Petersen SR, Jones RL (2003a) Effects of helium and 40% O2 on graded exercise with self-contained breathing apparatus. Can J Appl Physiol 28:910–926PubMed Eves ND, Petersen SR, Jones RL (2003a) Effects of helium and 40% O2 on graded exercise with self-contained breathing apparatus. Can J Appl Physiol 28:910–926PubMed
Zurück zum Zitat Eves ND, Petersen SR, Jones RL (2003b) Submaximal exercise with a self-contained breathing apparatus: the effects of hyperoxia and inspired gas density. Aviat Space Environ Med 74:1040–1047PubMed Eves ND, Petersen SR, Jones RL (2003b) Submaximal exercise with a self-contained breathing apparatus: the effects of hyperoxia and inspired gas density. Aviat Space Environ Med 74:1040–1047PubMed
Zurück zum Zitat Eves ND, Jones RL, Petersen SR (2005) The influence of self-contained breathing apparatus (SCBA) on ventilatory function and maximal exercise. Can J Appl Physiol 30:507–519PubMed Eves ND, Jones RL, Petersen SR (2005) The influence of self-contained breathing apparatus (SCBA) on ventilatory function and maximal exercise. Can J Appl Physiol 30:507–519PubMed
Zurück zum Zitat Eves ND, Petersen SR, Haykowsky MJ, Wong EY, Jones RL (2006) Helium-hyperoxia, exercise and respiratory mechanics in chronic obstructive pulmonary disease. Am J Respir Crit Care Med 174:763–771PubMedCrossRef Eves ND, Petersen SR, Haykowsky MJ, Wong EY, Jones RL (2006) Helium-hyperoxia, exercise and respiratory mechanics in chronic obstructive pulmonary disease. Am J Respir Crit Care Med 174:763–771PubMedCrossRef
Zurück zum Zitat Hayashi K, Honda Y, Ogawa T, Kondo N, Nishiyau T (2006) Relationship between ventilatory response and body temperature during prolonged submaximal exercise. J Appl Physiol 100:414–420PubMedCrossRef Hayashi K, Honda Y, Ogawa T, Kondo N, Nishiyau T (2006) Relationship between ventilatory response and body temperature during prolonged submaximal exercise. J Appl Physiol 100:414–420PubMedCrossRef
Zurück zum Zitat Johnson BD, Aaron EA, Babcock MA, Dempsey JA (1996) Respiratory muscle fatigue during exercise: implications for performance. Med Sci Sports Exerc 28:1129–1137PubMed Johnson BD, Aaron EA, Babcock MA, Dempsey JA (1996) Respiratory muscle fatigue during exercise: implications for performance. Med Sci Sports Exerc 28:1129–1137PubMed
Zurück zum Zitat Johnson BD, Weisman IM, Zeballos RJ, Beck KC (1999) Emerging concepts in the evaluation of ventilatory limitation during exercise: the exercise tidal flow–volume loop. Chest 116:488–503PubMedCrossRef Johnson BD, Weisman IM, Zeballos RJ, Beck KC (1999) Emerging concepts in the evaluation of ventilatory limitation during exercise: the exercise tidal flow–volume loop. Chest 116:488–503PubMedCrossRef
Zurück zum Zitat Lambert RK (1986) Analysis of bronchial mechanics and density dependence of maximal expiratory flow. J Appl Physiol 61:138–149PubMed Lambert RK (1986) Analysis of bronchial mechanics and density dependence of maximal expiratory flow. J Appl Physiol 61:138–149PubMed
Zurück zum Zitat McClaran SR, Wetter TJ, Pegelow DF, Dempsey JA (1999) Role of expiratory flow limitation in determining lung volumes and ventilation during exercise. J Appl Physiol 86:1357–1366PubMed McClaran SR, Wetter TJ, Pegelow DF, Dempsey JA (1999) Role of expiratory flow limitation in determining lung volumes and ventilation during exercise. J Appl Physiol 86:1357–1366PubMed
Zurück zum Zitat Melissant CF, Lammers JWJ, Demedts M (1998) Relationship between external resistances, lung function changes and maximal exercise capacity. Eur Respir J 11:1369–1375PubMedCrossRef Melissant CF, Lammers JWJ, Demedts M (1998) Relationship between external resistances, lung function changes and maximal exercise capacity. Eur Respir J 11:1369–1375PubMedCrossRef
Zurück zum Zitat Milic-Emili J, Mead J, Turner JM (1964) Topography of esophageal pressure as a function of posture in man. J Appl Physiol 19:212–216PubMed Milic-Emili J, Mead J, Turner JM (1964) Topography of esophageal pressure as a function of posture in man. J Appl Physiol 19:212–216PubMed
Zurück zum Zitat O’Donnell DE, Revill SM, Webb KA (2001) Dynamic hyperinflation and exercise intolerance in chronic obstructive pulmonary disease. Am J Respir Crit Care Med 164:770–777PubMed O’Donnell DE, Revill SM, Webb KA (2001) Dynamic hyperinflation and exercise intolerance in chronic obstructive pulmonary disease. Am J Respir Crit Care Med 164:770–777PubMed
Zurück zum Zitat Palange P, Valli G, Onorati P, Antonucci R, Paoletti P, Rosato A, Manfredi F, Serra P (2004) Effect of heliox on lung dynamic hyperinflation, dyspnea, and exercise endurance capacity in COPD patients. J Appl Physiol 97:1637–1642PubMedCrossRef Palange P, Valli G, Onorati P, Antonucci R, Paoletti P, Rosato A, Manfredi F, Serra P (2004) Effect of heliox on lung dynamic hyperinflation, dyspnea, and exercise endurance capacity in COPD patients. J Appl Physiol 97:1637–1642PubMedCrossRef
Zurück zum Zitat Pellegrino R, Brusasco V, Rodarte JR, Babb TG (1993) Expiratory flow limitation and regulation of end-expiratory lung volume during exercise. J Appl Physiol 4:2552–2558 Pellegrino R, Brusasco V, Rodarte JR, Babb TG (1993) Expiratory flow limitation and regulation of end-expiratory lung volume during exercise. J Appl Physiol 4:2552–2558
Zurück zum Zitat Roussos C, Campbell EJM (1986) Respiratory muscle energetics. In: Handbook of physiology. The respiratory system. Mechanics of breathing. Am Physiol Soc, Bethesda, MD, sect 3, vol 3, pt 2, chap 28, pp 481–509 Roussos C, Campbell EJM (1986) Respiratory muscle energetics. In: Handbook of physiology. The respiratory system. Mechanics of breathing. Am Physiol Soc, Bethesda, MD, sect 3, vol 3, pt 2, chap 28, pp 481–509
Zurück zum Zitat Schilder DP, Roberts A, Fry DL (1963) Effect of gas density and viscosity on the maximal expiratory flow–volume relationship. J Clin Invest 42:1705–1713PubMedCrossRef Schilder DP, Roberts A, Fry DL (1963) Effect of gas density and viscosity on the maximal expiratory flow–volume relationship. J Clin Invest 42:1705–1713PubMedCrossRef
Zurück zum Zitat Sliwinski P, Yan S, Gauthier AP, Macklem PT (1996) Influence of global inspiratory muscle fatigue on breathing during exercise. J Appl Physiol 80:1270–1278PubMed Sliwinski P, Yan S, Gauthier AP, Macklem PT (1996) Influence of global inspiratory muscle fatigue on breathing during exercise. J Appl Physiol 80:1270–1278PubMed
Zurück zum Zitat Stubbing DG, Pengelly LD, Morse JC, Jones NL (1980) Pulmonary mechanics during exercise in normal males. J Appl Physiol 49:506–510PubMed Stubbing DG, Pengelly LD, Morse JC, Jones NL (1980) Pulmonary mechanics during exercise in normal males. J Appl Physiol 49:506–510PubMed
Zurück zum Zitat Wang LY, Cerny FJ (2004) Ventilatory response to exercise in simulated obesity by chest loading. Med Sci Sports Exerc 36:780–786PubMedCrossRef Wang LY, Cerny FJ (2004) Ventilatory response to exercise in simulated obesity by chest loading. Med Sci Sports Exerc 36:780–786PubMedCrossRef
Zurück zum Zitat West JB (2005) Respiratory physiology: the essentials, 7th edn. Lippincott Williams and Wilkins, Philadelphia West JB (2005) Respiratory physiology: the essentials, 7th edn. Lippincott Williams and Wilkins, Philadelphia
Zurück zum Zitat Wilson GD, Welch HG (1980) Effects of varying concentrations of N2/O2 and He/O2 on exercise tolerance in man. Med Sci Sports Exerc 12:380–384PubMedCrossRef Wilson GD, Welch HG (1980) Effects of varying concentrations of N2/O2 and He/O2 on exercise tolerance in man. Med Sci Sports Exerc 12:380–384PubMedCrossRef
Zurück zum Zitat Yan S, Kayser B, Tobiasz M, Sliwinski P (1996) Comparison of static and dynamic intrinsic positive end-expiratory pressure using the Campbell diagram. Am J Respir Crit Care Med 154:938–944PubMed Yan S, Kayser B, Tobiasz M, Sliwinski P (1996) Comparison of static and dynamic intrinsic positive end-expiratory pressure using the Campbell diagram. Am J Respir Crit Care Med 154:938–944PubMed
Metadaten
Titel
Impaired exercise ventilatory mechanics with the self-contained breathing apparatus are improved with heliox
verfasst von
Scott J. Butcher
Richard L. Jones
Jonathan R. Mayne
Timothy C. Hartley
Stewart R. Petersen
Publikationsdatum
01.12.2007
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 6/2007
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-007-0541-5

Weitere Artikel der Ausgabe 6/2007

European Journal of Applied Physiology 6/2007 Zur Ausgabe

Neu im Fachgebiet Arbeitsmedizin

Elterliches Belastungserleben, Unaufmerksamkeits‑/Hyperaktivitätssymptome und elternberichtete ADHS bei Kindern und Jugendlichen: Ergebnisse aus der KiGGS-Studie

Open Access ADHS Leitthema

Die Aufmerksamkeitsdefizit‑/Hyperaktivitätsstörung (ADHS) ist eine der häufigsten psychischen Störungen im Kindes- und Jugendalter [ 1 ]. In Deutschland beträgt die Prävalenz einer elternberichteten ADHS-Diagnose bei Kindern und Jugendlichen 4,4 % …

Substanzkonsum und Nutzung von sozialen Medien, Computerspielen und Glücksspielen unter Auszubildenden an beruflichen Schulen

Open Access Leitthema

Die Begrenzung von Schäden durch Substanzkonsum und andere abhängige Verhaltensweisen von Jugendlichen und jungen Erwachsenen ist ein wichtiges Anliegen der öffentlichen Gesundheit. Der Übergang von der Adoleszenz zum jungen Erwachsenenalter ist …

Berufsbelastung und Stressbewältigung von weiblichen und männlichen Auszubildenden

Leitthema

In der Öffentlichkeit wird die berufliche Ausbildung oftmals unter ökonomischen Gesichtspunkten diskutiert: Mit den geburtenstarken Jahrgängen gehen erfahrene Fachkräfte in Rente und von nachfolgenden Generationen rücken zu wenige Arbeitskräfte …

Rauschtrinken in der frühen Adoleszenz

COVID-19 Leitthema

Alkohol ist in Deutschland die mit Abstand am häufigsten konsumierte psychoaktive Substanz. Mehr als 2 Drittel aller Erwachsenen im Alter von 18 bis 64 Jahren (70,5 %) hat 2021 in den letzten 30 Tagen Alkohol konsumiert [ 1 ]. Von diesen …