Skip to main content
Erschienen in: Journal of Nuclear Cardiology 3/2014

01.06.2014 | Original Article

Inappropriate utilization of SPECT myocardial perfusion imaging on the USA-Mexico border

verfasst von: Omosalewa O. Lalude, MBBS, FACC, Mell F. Gutarra, MD, Eduardo N. Pollono, MD, Soyoung Lee, MSCS, Patrick M. Tarwater, PhD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 3/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

The American College of Cardiology/American Society of Nuclear Cardiology published revised appropriate use criteria (AUC) for SPECT MPI in 2009. We assessed adherence to these guidelines and factors associated with inappropriate utilization at the University Medical Center.

Methods

The AUC was applied retrospectively to 420 SPECT MPI studies. Two-sample t test, Fisher’s exact test, and multivariable logistic regression models were used for analysis.

Results

There were 322 appropriate (86%) and 54 (14%) inappropriate studies. The odds of having an inappropriate test increased with younger age (P < .001) and female gender (P < .001). Subjects with diabetes (P = .007) and chest pain (P < .001) were less likely to have an inappropriate test. Academic outpatients were three times more likely to have an inappropriate study (P = .123), while community PCPs were 5.6 times (P = .011) and community cardiologists eight times more likely to order inappropriate tests (P = .031).

Conclusions

Inappropriate SPECT MPI in low risk younger women is an important issue on the USA-Mexico border. Initiatives to reduce inappropriate SPECT MPI should focus on a few indications and evaluation of cardiovascular symptoms in younger age women in outpatient/community practices.
Literatur
1.
Zurück zum Zitat Mehta R, Ward RP, Chandra S, Agarwal R, Williams KA. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging. J Nucl Cardiol 2008;15:337-44.PubMedCrossRef Mehta R, Ward RP, Chandra S, Agarwal R, Williams KA. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging. J Nucl Cardiol 2008;15:337-44.PubMedCrossRef
2.
Zurück zum Zitat Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol 2008;51:1283-9.PubMedCrossRef Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol 2008;51:1283-9.PubMedCrossRef
3.
Zurück zum Zitat Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol 2010;55:156-62.PubMedCrossRef Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol 2010;55:156-62.PubMedCrossRef
4.
Zurück zum Zitat Nelson KH, Willens HJ, Hendel RC. Utilization of radionuclide myocardial perfusion imaging in two health care systems: Assessment with the 2009 ACCF/ASNC/AHA appropriateness use criteria. J Nucl Cardiol 2012;19:37-42.PubMedCrossRef Nelson KH, Willens HJ, Hendel RC. Utilization of radionuclide myocardial perfusion imaging in two health care systems: Assessment with the 2009 ACCF/ASNC/AHA appropriateness use criteria. J Nucl Cardiol 2012;19:37-42.PubMedCrossRef
5.
Zurück zum Zitat Brindis RG, Douglas PS, Hendel RC, Peterson ED, Wolk MJ, Allen JM, et al. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol 2005;46:1587-605.PubMedCrossRef Brindis RG, Douglas PS, Hendel RC, Peterson ED, Wolk MJ, Allen JM, et al. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol 2005;46:1587-605.PubMedCrossRef
6.
Zurück zum Zitat Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation appropriate use criteria task force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. J Am Coll Cardiol 2009;53:2201-29.PubMedCrossRef Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation appropriate use criteria task force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. J Am Coll Cardiol 2009;53:2201-29.PubMedCrossRef
7.
Zurück zum Zitat Gibbons RJ, Askew WJ, Hodge D, Miller TD. Temporal trends in compliance with appropriateness criteria for stress single-photon emission computed tomography sestamibi studies in an academic medical center. Am Heart J 2010;159:484-9.PubMedCrossRef Gibbons RJ, Askew WJ, Hodge D, Miller TD. Temporal trends in compliance with appropriateness criteria for stress single-photon emission computed tomography sestamibi studies in an academic medical center. Am Heart J 2010;159:484-9.PubMedCrossRef
8.
Zurück zum Zitat Gupta A, Tsiaras SV, Dunsiger SI, Tilkemeier PL. Gender disparity and the appropriateness of myocardial perfusion imaging. J Nucl Cardiol 2011;18:588-94.PubMedCrossRef Gupta A, Tsiaras SV, Dunsiger SI, Tilkemeier PL. Gender disparity and the appropriateness of myocardial perfusion imaging. J Nucl Cardiol 2011;18:588-94.PubMedCrossRef
9.
Zurück zum Zitat Carryer DJ, Askew JW, Hodge D, Miller TD, Gibbons RJ. The impact of ordering provider specialty on appropriateness classification. J Nucl Cardiol 2012;19:285-90.PubMedCrossRef Carryer DJ, Askew JW, Hodge D, Miller TD, Gibbons RJ. The impact of ordering provider specialty on appropriateness classification. J Nucl Cardiol 2012;19:285-90.PubMedCrossRef
10.
Zurück zum Zitat Koh AS, Flores JL, Keng FY, Tan RS, Chua TS. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging in an Asian Tertiary Cardiac Center. J Nucl Cardiol 2011;18:324-30.PubMedCrossRef Koh AS, Flores JL, Keng FY, Tan RS, Chua TS. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging in an Asian Tertiary Cardiac Center. J Nucl Cardiol 2011;18:324-30.PubMedCrossRef
12.
Zurück zum Zitat Iglehart JK. The new era of medical imaging—Progress and pitfalls. N Engl J Med 2006;354:2822-8.PubMedCrossRef Iglehart JK. The new era of medical imaging—Progress and pitfalls. N Engl J Med 2006;354:2822-8.PubMedCrossRef
13.
Zurück zum Zitat Iglehart JK. Health insurers and medical-imaging policy—A work in progress. N Engl J Med 2009;360:1030-7.PubMedCrossRef Iglehart JK. Health insurers and medical-imaging policy—A work in progress. N Engl J Med 2009;360:1030-7.PubMedCrossRef
14.
Zurück zum Zitat Gibbons RJ, Askew JW, Hodge D, Kaping B, Carryer DJ, Miller T. Appropriate use criteria for stress single-photon emission computed tomography sestamibi studies: A quality improvement project. Circulation 2011;123:499-503.PubMedCrossRef Gibbons RJ, Askew JW, Hodge D, Kaping B, Carryer DJ, Miller T. Appropriate use criteria for stress single-photon emission computed tomography sestamibi studies: A quality improvement project. Circulation 2011;123:499-503.PubMedCrossRef
15.
Zurück zum Zitat Lin FY, Dunning AM, Narula J, Shaw LJ, Gransar H, Berman DS, et al. Impact of an automated multimodality point-of-order decision support tool on rates of appropriate testing and clinical decision making for individuals with suspected coronary artery disease: A prospective multicenter study. J Am Coll Cardiol 2013;62:308-15.PubMedCrossRef Lin FY, Dunning AM, Narula J, Shaw LJ, Gransar H, Berman DS, et al. Impact of an automated multimodality point-of-order decision support tool on rates of appropriate testing and clinical decision making for individuals with suspected coronary artery disease: A prospective multicenter study. J Am Coll Cardiol 2013;62:308-15.PubMedCrossRef
16.
Zurück zum Zitat Saifi S, Taylor AJ, Allen J, Hendel R. The use of a learning community and online evaluation of utilization for SPECT myocardial perfusion imaging. J Am Coll Cardiol Imaging 2013;6:823-9.CrossRef Saifi S, Taylor AJ, Allen J, Hendel R. The use of a learning community and online evaluation of utilization for SPECT myocardial perfusion imaging. J Am Coll Cardiol Imaging 2013;6:823-9.CrossRef
Metadaten
Titel
Inappropriate utilization of SPECT myocardial perfusion imaging on the USA-Mexico border
verfasst von
Omosalewa O. Lalude, MBBS, FACC
Mell F. Gutarra, MD
Eduardo N. Pollono, MD
Soyoung Lee, MSCS
Patrick M. Tarwater, PhD
Publikationsdatum
01.06.2014
Verlag
Springer US
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 3/2014
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-014-9881-9

Weitere Artikel der Ausgabe 3/2014

Journal of Nuclear Cardiology 3/2014 Zur Ausgabe

Nuclear Cardiology in the Literature

Review of cardiovascular literature

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.