Skip to main content
Erschienen in: Multidisciplinary Respiratory Medicine 1/2019

Open Access 01.12.2019 | Original research article

Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools

verfasst von: Zewudu Andualem, Zemichael Gizaw, Laekemariam Bogale, Henok Dagne

Erschienen in: Multidisciplinary Respiratory Medicine | Ausgabe 1/2019

Abstract

Background

Poor indoor air quality is a great problem in schools due to a high number of students per classroom, insufficient outside air supply, poor construction and maintenance of school buildings. Bacteria in the indoor air environment pose a serious health problem. Determination of bacterial load in the indoor environment is necessary to estimate the health hazard and to create standards for indoor air quality control. This is especially important in such densely populated facilities like schools.

Methods

Institutional based cross-sectional study was conducted among 51 randomly selected classrooms of eight public primary schools from March 29–April 26, 2018. To determine the bacterial load passive air sampling settle plate method was used by exposing a Petri dish of blood agar media for an hour. The Pearson correlation matrix was employed to assess the correlation between bacterial load and physical parameters.

Results

The grand total mean bacterial load was 2826.35 CFU/m3 in the morning and 4514.63 CFU/m3 in the afternoon. The lowest and highest mean bacterial load was recorded at school 3 (450.67 CFU/m3) and school 5 (7740.57 CFU/m3) in the morning and afternoon, respectively. In the morning relative humidity (r = − 0.7034), PM2.5 (r = 0.5723) and PM10 (r = 0.6856); in the afternoon temperature (r = 0.3838), relative humidity (r = − 0.4014) were correlated with indoor bacterial load. Staphylococcus aureus, Coagulase-negative Staphylococcus species and Bacillus species were among isolated bacteria.

Conclusions

High bacterial load was found in public primary schools in the Gondar city as compared to different indoor air biological standards. Temperature, relative humidity and particulate matter concentration (PM2.5 and PM10) were associated with the indoor bacterial load. Staphylococcus aureus, Coagulase-negative Staphylococcus species and Bacillus species were among isolated bacterial species. Attention should be given to control those physical factors which favour the growth and multiplication of bacteria in the indoor environment of classrooms to safeguard the health of students and teachers in school.
Abkürzungen
°C
Degree centigrade
am
Ante meridian
ANOVA
Analysis of variance
CFU
Colony forming units
cm2
Centimeter square
m3
Cubic meter
PM
Particulate matter
pm
Post meridian
ppm
Part per million
RH
Relative humidity
WHO
World Health Organization.
μg
Microgram

Background

Clean air is a basic requirement of life [1]. Most people spend 80–95% of their time in indoor environments by breathing on average 10–14 m3 of air per day [25]. Millions of children and adults spend 24–30% of their time in a day in school buildings, and they need safe, healthy environments to thrive, learn, and succeed [6, 7].
The indoor air quality has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people spend more time indoors than outdoors [810]. The quality of air inside, homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being [1].
Indoor air pollution is a major problem in people daily life. Efficient corrective methods are urgently needed to combat the problem of indoor air quality: bacteria, pollen grains, smoke, humidity, chemical substances, and gases released by anthropogenic activity which has adverse health effects in humans [11]. Several studies underscore the significant risks of global warming on human health due to increasing levels of air pollution. The last decades have seen a rise in the concentrations of pollens and pollutants in the air. This rise parallels the increase in the number of people presenting with allergic symptoms (e.g., allergic rhinitis, conjunctivitis, and asthma) [12].
Globally, 3.8 million deaths were attributed to indoor air pollution in 2016. More than 90% of air pollution-related deaths occur in low- and middle-income countries, mainly in Asia and Africa, followed by low- and middle-income countries of the Eastern Mediterranean region, Europe, and Americas [13]. Bioaerosols contribute about 5–34% of indoor air pollution [5, 6, 14, 15].
Indoor air quality problems in schools may be even more serious than in other categories of buildings, due to higher occupant density, poor sanitation of classrooms, and insufficient outside air supply, aggravated by frequent poor construction and maintenance of school buildings [16]. Poor indoor air quality can also affect scholarly performance and attendance since children are more vulnerable than adults to health risks from exposure to the environmental hazard [1618].
Therefore, the purpose of this research was to assess the bacterial quality of indoor air in public primary schools to increase awareness and provide references for better understanding about bacterial indoor air quality problems in public primary schools.

Methods and materials

Study design and study area

Institutional based cross-sectional study was conducted to assess indoor bacterial load and its relation to physical indoor air quality parameters of public primary schools in Gondar city, Northwest Ethiopia. Gondar city is located in the northern part of Ethiopia in Amhara national regional state, North Gondar zone at a distance of 727 km from Addis Ababa and 173.09 km from the regional capital Bahir Dar at the 12°45’north latitude and 37 ° 45′ east longitudes. In Gondar city there are twenty public primary schools from grade 1–8 with a total of 27,766 students enrolled in 266 classrooms [19].

Sample size and sampling procedures

The sample size was determined based on environmental sampling and sample size determination methods [20]. Manly formula was used to determine sample size [21] by using the following equation.
$$ n=\frac{4{\upsigma}^2\ }{\updelta^2} $$
Where n = Number of samples, σ = Standard deviation, δ = Acceptable error [δ is half of the width of a 95% the confidence interval on the mean (\( \overline{X}\pm \)δ)].
From a total of twenty public primary schools, 40% of the schools were selected through simple random sampling and 20% of classrooms at schools were selected as study unit through simple random sampling.
The mean and standard deviation (σ) of eight randomly selected public primary schools was 13.3 and 5.37 respectively, by taking 3% acceptable error (δ).
$$ n=\left[\frac{4\ast {(5.37)}^2}{(1.5)^2}\right]=51 $$
A total of fifty-one classrooms were selected from eight public primary schools of Gondar city by simple random sampling technique.

Air sampling procedures

Air samples were taken from 51 randomly selected classrooms from eight public primary schools in Gondar city. Bacterial measurements were made by passive air sampling method i.e., the settle plate method. Standard Petri dishes with 9 cm diameter (63.585 cm2 areas) containing culture media were exposed. Bacterial contamination determination was based on the count of the microbial fall out on to Petri dishes left open to the air, according to the 1/1/1 scheme (for 1 h, 1 m away from the floor, at least 1 m away from walls or any obstacle) [14]. Bacteria were collected on blood agar media to which an antifungal agent (Griseofulvin) had been added to inhibit the growth of fungi. To determine the bacterial load with respect to environmental variation, sampling was done in the morning (at 6:30 am before students enter to the classroom) and afternoon (5:00 pm, after students left the classroom). After exposure, the sample was taken to the laboratory (Department of Biology, at the University of Gondar) and incubated at 37 °C for 24 to 48 h. Colony forming units (CFU) was enumerated, CFU/m3 microbial concentration was determined, using the following equation [22].
$$ \raisebox{1ex}{$\mathrm{N}=\mathrm{a}\ast 10000$}\!\left/ \!\raisebox{-1ex}{$\mathrm{bt}\ast 0.2$}\right. $$
Where N = Microbial CFU/m3 of indoor air; a = Number of colonies per Petri dish; b = Dish surface area (cm2); t = Exposure time.
Individual bacterial isolates were identified using standard methods (including colonial morphology, microscopy, and biochemical tests) [23, 24].
Parallel with bacterial sample collection, data on physical parameters such as CO2 concentration, particulate matter concentration (PM2.5 and PM10), indoor temperature, and relative humidity were measured by Aireveda. To minimize dilution of air contaminants, openings like doors and windows were closed [7, 25, 26]. In addition, the movement of people during sampling was restricted to avoid air disturbance and newly emitted microorganisms.

Data analysis

Statistical analyses were carried out using STATA/SE 14.0. To assess the correlation of bacteria concentration with environmental factors like carbon dioxide concentration, particulate matter concentration (PM2.5 and PM10), temperature and relative humidity Pearson correlation was employed. One way analysis of variance (ANOVA) was carried out to know the mean difference of the bacterial load in public primary schools.

Results

Bacterial load

The concentrations of bacterial aerosols in the indoor environment of public primary schools in Gondar city, estimated with the use of the settle plate method, the lowest and highest bacterial load was estimated in the morning in school 1 (208 CFU/m3) and in the afternoon in school 5 (23,504 CFU/m3) (Table 1).
Table 1
Statistical summary of bacterial load, in public primary schools of Gondar city, Northwest Ethiopia, 2018. (n = 51)
Name of School
Number of classrooms
Mean
Standard deviation
Minimum
Maximum
Median
Morning bacterial load
 School 1
5
702.00
316.44
390
1183
741
 School 2
7
1131.00
515.87
559
2145
1066
 School 3
3
450.67
314.52
208
806
338
 School 4
8
5843.50
1973.45
3588
8528
5356
 School 5
7
5588.14
2167.85
3341
9100
4420
 School 6
8
3284.13
1185.78
2067
5668
3321.5
 School 7
7
748.43
179.95
585
1105
767
 School 8
6
2331.33
801.49
1430
3666
2158
 Total
51
2826.35
2408.76
208
9100
2093
Afternoon bacterial load
 School 1
5
1510.60
1267.53
728
3757
1001
 School 2
7
5404.29
2320.31
2301
8502
5460
 School 3
3
507.00
144.76
351
637
533
 School 4
8
5073.25
2517.63
2600
9984
4082
 School 5
7
7740.57
7228.03
2340
23,504
5304
 School 6
8
1158.63
709.06
260
2652
994.5
 School 7
7
4561.57
2031.61
819
7332
4332
 School 8
6
7895.33
1403.10
5720
9880
7943
 Total
51
4514.63
3918.20
260
23,504
3939
The grand total mean bacterial load was 2826.35 and 4514.63 CFU/m3 in the morning and afternoon, respectively, while the overall mean bacterial load was 3670.49 CFU/m3 (Table 1). ANOVA test result was presented to show the mean bacterial load difference among different public primary schools. The test showed that there was a significant mean bacterial load difference among public primary schools at p < 0.001 (Table 2).
Table 2
ANOVA test result on mean bacterial load difference among public primary schools of Gondar city, Northwest Ethiopia 2018
Analysis of Variance
 Source variation
Sum of Square
Degree of freedom
Mean Square
F
Sig.
 Between groups
189,395,110
7
27,056,444.3
7.67
<  0.001
 Within groups
151,708,969
43
3,528,115.56
  
 Total
341,104,079
50
6,822,081.58
  

Physical parameters of indoor air environments

During physical parameter measurement, it was found that all examined classrooms did not have an HVAC (heating, ventilation, and air conditioning) system. The ranges of carbon dioxide concentration, indoor temperature, relative humidity, and particulate matter concentration (PM2.5 & PM10) during sampling time ranged from 401 to 550 ppm, 12 to 24 °C, 14 to 64%, 7 to 173 μg/m3, and 21 to 277 μg/m3 respectively (Table 3).
Table 3
Statistical summary of physical indoor air quality parameters in public primary schools of Gondar city, Northwest Ethiopia, 2018 (n = 51)
Variables
Mean
Standard Deviation
Median
Minimum
Maximum
CO2 6:30 am
458.54
30.44
453
406
550
CO2 5:00 pm
429.12
27.05
422
401
548
T °C 6:30 am
14.27
0.94
14
12
16
T °C 5:00 pm
19.02
3.08
20
15
24
RH%6:30 am
39.37
14.25
45
21
61
RH%5:00 pm
36.37
13.89
39
14
57
PM2.5 6:30 am
68.18
43.42
48
18
173
PM2.5 5:00 pm
12.82
3.38
13
7
22
PM10 6:30 am
138.06
68.64
129
42
277
PM10 5:00 pm
55.92
22.06
51
21
144
N.B Carbon dioxide, (CO2, ppm); Temperature, (T, °C); Relative humidity, RH (%); concentration of particulate matter concentration PM10 and PM2.5 (μg/m3)

Isolated bacterial species

Three bacterial species were isolated; Bacillus species, Staphylococcus aureus and Coagulase-negative Staphylococcus (CoNS) species. Bacillus species was found in all public primary schools (Table 4).
Table 4
Type of microorganism isolated from each public Primary schools in Gondar city Northwest Ethiopia, 2018 (n = 51)
School ID
Number of classrooms
Bacterial Isolates
SA
BA
CoNS
School 1
5
+
+
School 2
7
+
+
+
School 3
3
+
+
+
School 4
8
+
+
+
School 5
7
+
+
School 6
8
+
+
+
School 7
7
+
+
+
School 8
6
+
+
Total
51
7
8
6
N.B. Staphylococcus aureus (SA), Bacillus species (BA), Coagulase negative staphylococcus species (CoNS), + = Present,  = absent
According to the European sanitary standards for non-industrial premises, the degree of air pollution by bacteria population across the various classrooms of the eight public primary schools ranges largely between high to very high (Table 5).
Table 5
Assessments of bacterial indoor air quality in the selected eight public Primary schools in Gondar city, according to the sanitary standards for non-industrial premises (n = 51)
 
Bacterial
Sampling time
 
6:30–7:30 am
5:00–6:00 pm
Range of values (CFU/m3)
 
< 50
50–100
100–500
500–2000
> 2000
< 50
50–100
100–500
500–2000
> 2000
Degree of Air Pollution
Very low
Low
Intermediate
High
Very high
Very low
Low
Intermediate
High
Very high
School
School 1
 
School 2
 
School 3
 
School 4
 
School 5
 
School 6
 
School 7
 
School 8
NB: ≤ 500 CFU/m3 is the permissive standard, () in the range; () not in the range
Relative humidity, particulate matter concentration and temperature correlated with an indoor bacterial load of public primary schools from all physical indoor air quality parameters; relative humidity had a negative strong correlation with indoor bacterial load (Table 6).
Table 6
Pearson correlation coefficients between indoor bacterial concentration & physical indoor air quality parameters in public primary schools of Gondar city, Northwest Ethiopia, 2018. (n = 51)
Variables
Bacteria
CO2
T (°C)
RH (%)
PM2.5
PM10
Morning
 Bacteria
1.00
     
 CO2
0.1049
1.00
    
 T °C
0.0007
−0.0928
1.00
   
 RH%
−0.7034a
0.2237
−0.0839
1.00
  
 PM2.5
0.5723a
0.2226
−0.0767
− 0.3634a
1.00
 
 PM10
0.6856a
0.1573
−0.0762
−0.5493a
0.9447a
1.00
Afternoon
 Bacteria
1.00
     
 CO2
−0.1641
1.00
    
 T °C
0.3838a
−0.1820
1.00
   
 RH%
−0.4014a
0.4510a
−0.8420a
1.00
  
 PM2.5
−0.1100
0.6676a
−0.2036
0.4368a
1.00
 
 PM10
0.1856
0.5418a
0.2903a
−0.0771
0.4460a
1.00
N.B = a Correlation is significant at the 0.05 level; Carbon dioxide, (ppm); Temperature, T (°C); Relative humidity, RH (%); concentration of particulate matter PM10 and PM2.5 (μg/m3)

Discussion

The bacterial load of indoor air environments of public primary schools in Gondar city was found in the range between 208 and 23,504 CFU/m3 with a mean bacterial load of 3670.49 CFU/m3, the finding of this study was higher than the findings of other studies, one conducted in Poland, [27] and another in Malaysia, [28].
There are no generally accepted threshold limit values concerning concentrations of the air of indoor bacteria, and the obtained results could be compared only with the values recommended by various authors or institutions. The work conducted by a WHO expert group on assessment of health risks of biological agents in indoor environments suggested that total microbial concentration should not exceed 1000 CFU/m3 [29], whereas other scholars considered that 750 CFU/m3 should be the limit for bacteria [30]. Airborne microbial concentrations ranging from 4500 to 10,000 CFU/m3 also have been suggested as the upper limit for ubiquitous bacterial aerosols [31]. According to the sanitary standards of the European Commission for non-industrial premises, the permissible limits of bacterial load were ≤ 500 CFU/m3 [32]. The variation of bacterial load in indoor environments might be due to environmental factors such as ventilation system of classroom, temperature, humidity, and particulate matter concentration.
The finding of isolated bacterial species of the present study partly agrees with the work by Hussin N. et al. [28]. Likewise, it was harmonized in a study conducted in India [33], and it was partly agreed in the work by Naruka K. et al., [34].
In this study, the temperature of the indoor environment had a positive correlation with total airborne bacteria in the afternoon (r = 0.3838) while there was no correlation in the morning airborne bacterial concentration. During the study, the temperature ranged from 12 to 16 °C and 15–26 °C in morning and afternoon, respectively. This was consistent with the results reported by Brągoszewska Ewa, et al. [35], but inconsistent with the results reported by Naruka et al. [34], where the temperature was negatively correlated, and Hayleeyesus S. et al. [14] where there was no correlation between temperature and indoor bacterial load.
The bacterial load would be significantly correlated with indoor temperature, i.e., the concentration of aerosols will increase as the temperature increases [35], but the variation might be due to the fact that other environmental factors increase the concentration of bacteria in classrooms and the number of students may result in a great diversity of high bacterial load [36].
In this study relative moderate to strong humidity was negatively correlated with total airborne bacteria in the afternoon (r = − 0.4014) and in the morning (r = − 0.7034), respectively. The RH in public primary schools ranged from 21 to 62 % and 14–57 % in morning and afternoon, respectively. The negative correlation between relative humidity and indoor airborne bacterial load was not consistent with what is expected since a strict correlation between bacterial load and relative humidity was already reported by Brągoszewska Ewa, et al. [35], Huang H, et al. [37]. The possible explanation might be that if relative humidity decreases, bacterial load becomes decreased because the viability of aerosols becomes inhibited if relative humidity is too low, because a dry environment decreases the metabolism and physiological activities of microorganisms [35].
Correlation of PM2.5 was positively strong with total airborne bacteria (r = 0.5723), while there is no correlation in the afternoon airborne bacterial concentration. The positive correlation of this finding is in agreement with a study conducted in Poland [38], but in other study conducted in Poland [35], PM2.5 was negatively correlated.
In this study, PM10 had a strong positive correlation with airborne bacterial load (r = 0.6856) but there was no correlation with the afternoon airborne bacterial load. The positive correlation is supported by a study conducted in Poland [35]. The possible explanation might be due to the fact that the PM10 increases the bacterial load that increases because of bioaerosols attached to coarse solid particles [39]; whereas the afternoon particulate matter concentration was not correlated with indoor bacterial load due to other environmental factors which have a more significant correlation with concentration bacterial load as compared to PM10, and the concentration of PM10 in the afternoon is lower when compared in the morning.

Conclusions

A high bacterial load was found in public primary school classrooms in the Gondar city as compared with different indoor air biological standards. Temperature, humidity, and particulate matter concentration (PM2.5 and PM10) were associated with the indoor bacterial load. Staphylococcus aureus, Coagulase-negative Staphylococcus, and Bacillus were among isolated bacterial species. Attention should be given to control those physical factors which favour the growth and multiplication of bacteria in the indoor environment of classrooms to safeguard the health of students and teachers in school.

Acknowledgements

Firstly, we would like to give our heartfelt thanks to the Almighty of God for giving us the wisdom, knowledge and all the support we needed to do this study. We would like to express our appreciation to the University of Gondar College of Medicine and Health Sciences and public primary school directors and teachers for their support.

Funding

No funding source.

Availability of data and materials

Data will be made available upon request to the primary author.
Ethical clearance was obtained from the Institutional Review Board of the University of Gondar (ref. number: IPH/295/2017). Then, an official letter from the University of Gondar Research and Community Service Vice President and supportive letter from Institute of public health college of Medicine and Health Sciences was written to the respective responsible bodies. Confidentiality of the data was maintained. No identifiers except coding were included in the data collection tools.
This manuscript does not contain any individual person’s data.

Competing interest

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat World Health Organization, WHO guidelines for Indoor Air quality: selected pollutants. 2010. World Health Organization, WHO guidelines for Indoor Air quality: selected pollutants. 2010.
2.
Zurück zum Zitat Fekadu HS, Melaku MA. Microbiological quality of indoor air in university libraries. Asian Pacific journal of tropical biomedicine. 2014;4:S312–7.CrossRef Fekadu HS, Melaku MA. Microbiological quality of indoor air in university libraries. Asian Pacific journal of tropical biomedicine. 2014;4:S312–7.CrossRef
3.
Zurück zum Zitat Awad Abdel Hameed A, Farag SA. An indoor bio-contaminants air quality. Int J Environ Health Res. 1999;9(4):313–9.CrossRef Awad Abdel Hameed A, Farag SA. An indoor bio-contaminants air quality. Int J Environ Health Res. 1999;9(4):313–9.CrossRef
4.
Zurück zum Zitat Peter SG, Yakubu SE. Comparative analysis of airborne microbial concentrations in the indoor environment of two selected clinical laboratories. IOSR J Pharm Biol Sci (IOSR-JPBS). 2013;8:4. Peter SG, Yakubu SE. Comparative analysis of airborne microbial concentrations in the indoor environment of two selected clinical laboratories. IOSR J Pharm Biol Sci (IOSR-JPBS). 2013;8:4.
5.
Zurück zum Zitat Uzoechi AU, et al. Microbiological Evaluation of Indoor Air Quality of State University Library. Asian J Applied Sciences. 2017;05(03):525-30. Uzoechi AU, et al. Microbiological Evaluation of Indoor Air Quality of State University Library. Asian J Applied Sciences. 2017;05(03):525-30.
6.
Zurück zum Zitat Samson E, Ihongbe JC, Okeleke Ochei, Hi Effedua, Phillips Adeyemi O. Microbiological assessment of indoor air quality of some selected private primary schools in Ilishan-Remo, Ogun state. Nigeria. 2017;3:2454–9142. Samson E, Ihongbe JC, Okeleke Ochei, Hi Effedua, Phillips Adeyemi O. Microbiological assessment of indoor air quality of some selected private primary schools in Ilishan-Remo, Ogun state. Nigeria. 2017;3:2454–9142.
7.
Zurück zum Zitat Mohan K, Madhan N, Ramprasad S, Maruthi YA. Microbiological air quality of indoors in primary and secondary schools of Visakhapatnam, India. Int J Curr Microbiol App Sci. 2014;3(8):880–7. Mohan K, Madhan N, Ramprasad S, Maruthi YA. Microbiological air quality of indoors in primary and secondary schools of Visakhapatnam, India. Int J Curr Microbiol App Sci. 2014;3(8):880–7.
8.
Zurück zum Zitat Cahna N, Martinho M, Almeida-Silva M, Freitas MC. Indoor air quality in primary schools. Int J Environment and Pollution. 2012;50:396–410. Cahna N, Martinho M, Almeida-Silva M, Freitas MC. Indoor air quality in primary schools. Int J Environment and Pollution. 2012;50:396–410.
9.
Zurück zum Zitat Cahna N, Freitas MC, Almeida SM, Almeida-Silva M. Indoor school enviroment: Easy and low cost to assess inorganic pollutants. J Radioanal Nucl Chem. 2010;286(2):495–500. Cahna N, Freitas MC, Almeida SM,  Almeida-Silva M. Indoor school enviroment: Easy and low cost to assess inorganic pollutants. J Radioanal Nucl Chem. 2010;286(2):495–500.
10.
Zurück zum Zitat Freitas MC, Canha N, Martinho M, Almeida-Silva M, Almeida SM, Pegas P, et al. Chapter 20:‘Indoor air quality in primary school’, in Advanced Topics in Environmental Health and Air Pollution Case Studies, Anca Maria Moldoveanu, Editor. 2011. InTech Press: Croatia. 361-84. Freitas MC, Canha N, Martinho M, Almeida-Silva M, Almeida SM, Pegas P, et al. Chapter 20:‘Indoor air quality in primary school’, in Advanced Topics in Environmental Health and Air Pollution Case Studies, Anca Maria Moldoveanu, Editor. 2011. InTech Press: Croatia. 361-84.
11.
Zurück zum Zitat Kalpana S. Indoor air pollution. Bhartiya Krishi Anusandhan Patrika. 2016. 4. Kalpana S. Indoor air pollution. Bhartiya Krishi Anusandhan Patrika. 2016. 4. 
12.
Zurück zum Zitat Patella V, Florio G, Magliacane D, Giuliano A, Crivellaro MA, Di Bartolomeo D, etal. Urban air pollution and climate change:“the Decalogue: allergy safe tree” for allergic and respiratory diseases care. Clin Mol Allergy. 2018;16(1):20. Patella V,  Florio G, Magliacane D, Giuliano A, Crivellaro MA, Di Bartolomeo D, etal. Urban air pollution and climate change:“the Decalogue: allergy safe tree” for allergic and respiratory diseases care. Clin Mol Allergy. 2018;16(1):20.
14.
Zurück zum Zitat Fekadu HS, Amanuel E, Aklilu DF. Quantitative assessment of bio-aerosols contamination in indoor air of university dormitory rooms. Int J Health Sci. 2015;9(3):249. Fekadu HS, Amanuel E, Aklilu DF. Quantitative assessment of bio-aerosols contamination in indoor air of university dormitory rooms. Int J Health Sci. 2015;9(3):249.
15.
Zurück zum Zitat Zemichael G, Mulat G, Chalachew Y. High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia. Multidiscip Respir Med. 2016;11(1):24. Zemichael G, Mulat G, Chalachew Y. High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia. Multidiscip Respir Med. 2016;11(1):24.
16.
Zurück zum Zitat Nascimento Pegas P, Alves C, Guennadievna Evtyugina M, Nunes T. Indoor air quality in elementary schools of Lisbon in Spring. Environ Geochem Health . 2010;33:455–68. Nascimento Pegas P, Alves C,  Guennadievna Evtyugina M, Nunes T. Indoor air quality in elementary schools of  Lisbon in Spring. Environ Geochem  Health . 2010;33:455–68.
17.
Zurück zum Zitat Daisey Joan M, Angell William J, Apte Michael G. Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. Indoor Air. 2003;13(1):53–64.CrossRef Daisey Joan M, Angell William J, Apte Michael G. Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. Indoor Air. 2003;13(1):53–64.CrossRef
18.
Zurück zum Zitat Godoi RHM, et al. Indoor air quality assessment of elementary schools in Curitiba, Brazil. Water Air Soil Pollut. 2009;9(3–4):171–7. Godoi RHM, et al. Indoor air quality assessment of elementary schools in Curitiba, Brazil. Water Air Soil Pollut. 2009;9(3–4):171–7.
19.
Zurück zum Zitat Gondar city education office, Number of students enrolled in Gondar city public primary schools from grade 1–8 2018. Gondar city education office, Number of students enrolled in Gondar city public primary schools from grade 1–8 2018.
20.
Zurück zum Zitat Chunlong Z. Fundamentals of environmental sampling and analysis. Hoboken: Wiley; 2007. Chunlong Z. Fundamentals of environmental sampling and analysis. Hoboken: Wiley; 2007.
21.
Zurück zum Zitat Manly Bryan FJ. Statistics for environmental science and management. New York: Chapman and Hall/CRC; 2008. Manly Bryan FJ. Statistics for environmental science and management. New York: Chapman and Hall/CRC; 2008.
22.
Zurück zum Zitat Dumała Sławomira M, Dudzińska Marzenna R. Microbiological indoor air quality in polish schools. Annual Set The Environment Protection (Rocznik Ochrona Środowiska). 2013;15:231–44. Dumała Sławomira M, Dudzińska Marzenna R. Microbiological indoor air quality in polish schools. Annual Set The Environment Protection (Rocznik Ochrona Środowiska). 2013;15:231–44.
23.
Zurück zum Zitat Cheesbrough M. Biochemical tests to identify bacteria. In: Cheesbrough M, editor. District laboratory practice in topical countries, part 2, vol. 180. Cape Town: Cambridge University Press; 2006;63–70. Cheesbrough M. Biochemical tests to identify bacteria. In: Cheesbrough M, editor. District laboratory practice in topical countries, part 2, vol. 180. Cape Town: Cambridge University Press; 2006;63–70.
24.
Zurück zum Zitat Rajesh B, Lal IR. Essentials of medical microbiology. New Delhi: Jaypee Brothers, Medical Publishers Pvt. Limited; 2008. Rajesh B, Lal IR. Essentials of medical microbiology. New Delhi: Jaypee Brothers, Medical Publishers Pvt. Limited; 2008.
25.
Zurück zum Zitat Manisha J, Srivastava RK. Identification of indoor airborne microorganisms in residential rural houses of Uttarakhand, India. Int J Curr Microbiol Appl Sci. 2013;2:146–52. Manisha J, Srivastava RK. Identification of indoor airborne microorganisms in residential rural houses of Uttarakhand, India. Int J Curr Microbiol Appl Sci. 2013;2:146–52.
26.
Zurück zum Zitat Bartlett KH, Kennedy SM, Brauer M, van Netten C, Dill B. Evaluation and determinants of airborne bacterial concentrations in school classrooms. J Occup Environ Hyg. 2004;1(10):639–47. Bartlett KH, Kennedy SM, Brauer M, van Netten C, Dill B. Evaluation and determinants of airborne bacterial concentrations in school classrooms. J Occup Environ Hyg. 2004;1(10):639–47.
27.
Zurück zum Zitat Ewa Brągoszewska E, Mainka A, Pastuszka JS, Lizończyk K. Assessment of bacterial aerosol in a preschool, primary school and high school in Poland. Atmosphere. 2018;9(3):87. Ewa Brągoszewska E, Mainka A, Pastuszka JS, Lizończyk K. Assessment of bacterial aerosol in a preschool, primary school and high school in Poland. Atmosphere. 2018;9(3):87.
28.
Zurück zum Zitat Mat HNH, Sann LM, Shamsudin MN, Hashim Z. Characterization of bacteria and fungi bioaerosol in the indoor air of selected primary schools in Malaysia. Indoor Built Environ. 2011;20(6):607–17. Mat HNH, Sann LM, Shamsudin MN, Hashim Z. Characterization of bacteria and fungi bioaerosol in the indoor air of selected primary schools in Malaysia. Indoor  Built Environ. 2011;20(6):607–17.
29.
Zurück zum Zitat Heseltine Elisabeth and Rosen Jerome. WHO guidelines for indoor air quality: dampness and mould. Copenhagen: WHO Regional Office Europe; 2009. Heseltine Elisabeth and Rosen Jerome. WHO guidelines for indoor air quality: dampness and mould. Copenhagen: WHO Regional Office Europe; 2009.
30.
Zurück zum Zitat Rao Carol Y, Burge Harriet A, Chang John CS. Review of quantitative standards and guidelines for fungi in indoor air. J Air Waste Manage Assoc. 1996;46(9):899–908.CrossRef Rao Carol Y, Burge Harriet A, Chang John CS. Review of quantitative standards and guidelines for fungi in indoor air. J Air Waste Manage Assoc. 1996;46(9):899–908.CrossRef
31.
Zurück zum Zitat Hameed AA, Habeeballah T. Air microbial contamination at the holy mosque, Makkah, Saudi Arabia. Curr World Environ. 2013;8:179–87. Hameed AA, Habeeballah T. Air microbial contamination at the holy mosque, Makkah, Saudi Arabia. Curr World Environ. 2013;8:179–87.
32.
Zurück zum Zitat Wanner H, Verhoeff A, Colombi A, Flannigan B, Gravesen S, Mouilleseaux A, et al. Indoor air quality and its impact on man: report no. 12: biological particles in indoor Environments. Brussels-Luxembourg: ECSC-EEC-EAEC; 1993. Wanner H, Verhoeff A, Colombi A, Flannigan B, Gravesen S, Mouilleseaux A, et al. Indoor air quality and its impact on man: report no. 12: biological particles in indoor Environments. Brussels-Luxembourg: ECSC-EEC-EAEC; 1993.
33.
Zurück zum Zitat Kumari NK. Shravanthi Ch M, Byragi RT. Identification and assessment of airborne bacteria in selected school environments in Visakhapatnam. India Ind J Sci Res and tech. 2015;3(6):21–5. Kumari NK. Shravanthi Ch M, Byragi RT. Identification and assessment of airborne bacteria in selected school environments in Visakhapatnam. India Ind J Sci Res and tech. 2015;3(6):21–5.
34.
Zurück zum Zitat Kavita N, Jyoti G. Microbial air contamination in a school. Int J Curr Microbiol App Sci. 2012;2(12):404–10. Kavita N, Jyoti G. Microbial air contamination in a school. Int J Curr Microbiol App Sci. 2012;2(12):404–10.
35.
Zurück zum Zitat Bragoszewska E, Mainka A, Pastuszka JS. Concentration and size distribution of culturable bacteria in ambient air during spring and winter in Gliwice: a typical urban area. Atmosphere. 2017;8(12):239. Bragoszewska E, Mainka A, Pastuszka JS. Concentration and size distribution of culturable bacteria in ambient air during spring and winter in Gliwice: a typical urban area. Atmosphere. 2017;8(12):239.
36.
Zurück zum Zitat Viegas C, Faria T, Pacifico C, Guimarães dos Santos M. Microbiota and particulate matter assessment in Portuguese optical shops providing contact lens services. Healthcare. 2017;5(2):24. Viegas C, Faria T, Pacifico C, Guimarães dos Santos M. Microbiota and particulate matter assessment in Portuguese optical shops providing contact lens services. Healthcare. 2017;5(2):24.
37.
Zurück zum Zitat Hsiao-Lin H, Lee M-K, Hao-Wun S. Assessment of indoor bioaerosols in public spaces by real-time measured airborne particles. Aerosol Air Qual Res. 2017;17(9):2276–88.CrossRef Hsiao-Lin H, Lee M-K, Hao-Wun S. Assessment of indoor bioaerosols in public spaces by real-time measured airborne particles. Aerosol Air Qual Res. 2017;17(9):2276–88.CrossRef
38.
Zurück zum Zitat Bragoszewska E, Pastuszka JS. Influence of meteorological factors on the level and characteristics of culturable bacteria in the air in Gliwice, upper Silesia (Poland). Aerobiologia. 2018;34(2):241–55. Bragoszewska E, Pastuszka JS. Influence of meteorological factors on the level and characteristics of culturable bacteria in the air in Gliwice, upper Silesia (Poland). Aerobiologia. 2018;34(2):241–55.
39.
Zurück zum Zitat Min G, Yan X, Qiu T, Han M, Wang X. Variation of correlations between factors and culturable airborne bacteria and fungi. Atmos Environ. 2016;128:10–9. Min G, Yan X, Qiu T, Han M, Wang X. Variation of correlations between factors and culturable airborne bacteria and fungi. Atmos Environ. 2016;128:10–9.
Metadaten
Titel
Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
verfasst von
Zewudu Andualem
Zemichael Gizaw
Laekemariam Bogale
Henok Dagne
Publikationsdatum
01.12.2019
Verlag
BioMed Central
Erschienen in
Multidisciplinary Respiratory Medicine / Ausgabe 1/2019
Elektronische ISSN: 2049-6958
DOI
https://doi.org/10.1186/s40248-018-0167-y

Weitere Artikel der Ausgabe 1/2019

Multidisciplinary Respiratory Medicine 1/2019 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.