Skip to main content
Erschienen in: Anatomical Science International 2/2020

14.11.2019 | Original Article

Influence of storage on the quality of conventional CT and µCT-imaging for the middle and inner cat ear

verfasst von: Tobias Beck, T. Kilchling, S. Reese, A. Brühschwein, Andrea Meyer-Lindenberg

Erschienen in: Anatomical Science International | Ausgabe 2/2020

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to analyze whether different fixation methods such as freezing or formaldehyde storage for different periods of time have an influence on the recognition of anatomical relevant structures in the middle and inner ear of the cat with conventional computed tomography (cCT) and micro-computed tomography (µCT). Besides, effects of freeze–thaw cycles on determined structures of the ear were investigated by means of histological slices. Three veterinarians with different radiologic expertise evaluated the scans of 30 dissected cat ears anonymously and scored predefined structures in a five-point scale with reference to visually sharp reproducibility and perfect image quality. The total scores of the different fixation groups as well as the ears within a group were compared with each other. Furthermore, an intra-reader examination including an evaluation of the identifiability of specified structures was performed for both imaging methods. cCT as well as µCT-scans have a very low variation coefficient of 1.6% and 2.3%, respectively. The results for the alterations between the different fixation methods show that the changes for cCT-scans are negligible, as the percentage alteration compared to fresh samples ranges in a very small interval with values from 1.0% better to 1.2% worse. µCT-scans are more influenced by the fixation method with a range from 1.3% better to 6.9% worse values. The scans mostly deteriorated after two freeze–thaw cycles (1.8% worse) and after storing the samples for 1 (2.4% worse), respectively, and 3 weeks in formaldehyde (6.9% worse).
Literatur
Zurück zum Zitat Beck T, Kilchling TP, Meyer-Lindenberg A (2019) Differences between µCT-imaging and conventional CT for the diagnosis of possible diseases of the middle and inner cat ear. Anat Histol Embryol 48:268–276CrossRef Beck T, Kilchling TP, Meyer-Lindenberg A (2019) Differences between µCT-imaging and conventional CT for the diagnosis of possible diseases of the middle and inner cat ear. Anat Histol Embryol 48:268–276CrossRef
Zurück zum Zitat Bolliger SA, Tomasin D, Heimer J, Richter H, Thali MJ, Gascho D (2018) Rapid and reliable detection of previous freezing of cerebral tissue by computed tomography and magnetic resonance imaging. Forensic Sci Med Pathol 14:85–94CrossRef Bolliger SA, Tomasin D, Heimer J, Richter H, Thali MJ, Gascho D (2018) Rapid and reliable detection of previous freezing of cerebral tissue by computed tomography and magnetic resonance imaging. Forensic Sci Med Pathol 14:85–94CrossRef
Zurück zum Zitat Bongartz G, Golding S, Jurik A, Leonardi van Meerten E, Geleijns J, Jessen K, Panzer W, Shrimpton P, Tosi G (1998) European guidelines on quality criteria for computed tomography. EUR 16262 EN, 1–23 Bongartz G, Golding S, Jurik A, Leonardi van Meerten E, Geleijns J, Jessen K, Panzer W, Shrimpton P, Tosi G (1998) European guidelines on quality criteria for computed tomography. EUR 16262 EN, 1–23
Zurück zum Zitat Bullen A, Taylor RR, Kachar B, Moores C, Fleck RA, Forge A (2014) Inner ear tissue preservation by rapid freezing: improving fixation by high-pressure freezing and hybrid methods. Hear Res 315:49–60CrossRef Bullen A, Taylor RR, Kachar B, Moores C, Fleck RA, Forge A (2014) Inner ear tissue preservation by rapid freezing: improving fixation by high-pressure freezing and hybrid methods. Hear Res 315:49–60CrossRef
Zurück zum Zitat Cisneros JC, Brito R, Martins GS, Candido N, Ferraz R, Bento R (2017) Evaluation of the microgrinding procedure for the microscopic analysis of temporal bones. Cochlear Implants Int 18:106–115CrossRef Cisneros JC, Brito R, Martins GS, Candido N, Ferraz R, Bento R (2017) Evaluation of the microgrinding procedure for the microscopic analysis of temporal bones. Cochlear Implants Int 18:106–115CrossRef
Zurück zum Zitat Decraemer WF, Dirckx JJ, Funnell WR (2003) Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner. J Assoc Res Otolaryngol 4:250–263CrossRef Decraemer WF, Dirckx JJ, Funnell WR (2003) Three-dimensional modelling of the middle-ear ossicular chain using a commercial high-resolution X-ray CT scanner. J Assoc Res Otolaryngol 4:250–263CrossRef
Zurück zum Zitat Fallon JB, Shepherd RK, Nayagam DA, Wise AK, Heffer LF, Landry TG, Irvine DR (2014) Effects of deafness and cochlear implant use on temporal response characteristics in cat primary auditory cortex. Hear Res 315:1–9CrossRef Fallon JB, Shepherd RK, Nayagam DA, Wise AK, Heffer LF, Landry TG, Irvine DR (2014) Effects of deafness and cochlear implant use on temporal response characteristics in cat primary auditory cortex. Hear Res 315:1–9CrossRef
Zurück zum Zitat George SS, Wise AK, Shivdasani MN, Shepherd RK, Fallon JB (2014) Evaluation of focused multipolar stimulation for cochlear implants in acutely deafened cats. J Neural Eng 11:065003CrossRef George SS, Wise AK, Shivdasani MN, Shepherd RK, Fallon JB (2014) Evaluation of focused multipolar stimulation for cochlear implants in acutely deafened cats. J Neural Eng 11:065003CrossRef
Zurück zum Zitat Hammer N, Voigt C, Werner M, Hoffmann F, Bente K, Kunze H, Scholz R, Steinke H (2014) Ethanol and formaldehyde fixation irreversibly alter bones’ organic matrix. J Mech Behav Biomed Mater 29:252–258CrossRef Hammer N, Voigt C, Werner M, Hoffmann F, Bente K, Kunze H, Scholz R, Steinke H (2014) Ethanol and formaldehyde fixation irreversibly alter bones’ organic matrix. J Mech Behav Biomed Mater 29:252–258CrossRef
Zurück zum Zitat Hassepass F, Bulla S, Maier W, Laszig R, Arndt S, Beck R, Traser L, Aschendorff A (2014) The new mid-scala electrode array: a radiologic and histologic study in human temporal bones. Otol Neurotol 35:1415–1420CrossRef Hassepass F, Bulla S, Maier W, Laszig R, Arndt S, Beck R, Traser L, Aschendorff A (2014) The new mid-scala electrode array: a radiologic and histologic study in human temporal bones. Otol Neurotol 35:1415–1420CrossRef
Zurück zum Zitat Kim JS, Lee JS, Park M-H, Kang H, Lee JJ, Lee H-J, Im KC, Moon DH, Lim S-M, Oh S-H (2008) Assessment of cerebral glucose metabolism in cat deafness model: strategies for improving the voxel-based statistical analysis for animal PET studies. Mol Imaging Biol 10:154–161CrossRef Kim JS, Lee JS, Park M-H, Kang H, Lee JJ, Lee H-J, Im KC, Moon DH, Lim S-M, Oh S-H (2008) Assessment of cerebral glucose metabolism in cat deafness model: strategies for improving the voxel-based statistical analysis for animal PET studies. Mol Imaging Biol 10:154–161CrossRef
Zurück zum Zitat Klop AC, Vester MEM, Colman KL, Ruijter JM, Van Rijn RR, Oostra RJ (2017) The effect of repeated freeze-thaw cycles on human muscle tissue visualized by postmortem computed tomography (PMCT). Clin Anat 30:799–804CrossRef Klop AC, Vester MEM, Colman KL, Ruijter JM, Van Rijn RR, Oostra RJ (2017) The effect of repeated freeze-thaw cycles on human muscle tissue visualized by postmortem computed tomography (PMCT). Clin Anat 30:799–804CrossRef
Zurück zum Zitat Lander SL, Brits D, Hosie M (2014) The effects of freezing, boiling and degreasing on the microstructure of bone. Homo 65:131–142CrossRef Lander SL, Brits D, Hosie M (2014) The effects of freezing, boiling and degreasing on the microstructure of bone. Homo 65:131–142CrossRef
Zurück zum Zitat Lane JI, Witte RJ, Driscoll CL, Camp JJ, Robb RA (2004) Imaging microscopy of the middle and inner ear: Part I: CT microscopy. Clin Anat 17:607–612CrossRef Lane JI, Witte RJ, Driscoll CL, Camp JJ, Robb RA (2004) Imaging microscopy of the middle and inner ear: Part I: CT microscopy. Clin Anat 17:607–612CrossRef
Zurück zum Zitat Lee W, Jasiuk I (2014) Effects of freeze–thaw and micro-computed tomography irradiation on structure-property relations of porcine trabecular bone. J Biomech 47:1495–1498CrossRef Lee W, Jasiuk I (2014) Effects of freeze–thaw and micro-computed tomography irradiation on structure-property relations of porcine trabecular bone. J Biomech 47:1495–1498CrossRef
Zurück zum Zitat Levy AD, Harcke HT, Mallak CT (2010) Postmortem imaging: MDCT features of postmortem change and decomposition. Am J Forensic Med Pathol 31:12–17CrossRef Levy AD, Harcke HT, Mallak CT (2010) Postmortem imaging: MDCT features of postmortem change and decomposition. Am J Forensic Med Pathol 31:12–17CrossRef
Zurück zum Zitat Maran A, Khosla S, Riggs BL, Zhang M, Ritman EL, Turner RT (2003) Measurement of gene expression following cryogenic mu-CT scanning of human iliac crest biopsies. J Musculoskelet Neuronal Interact 3:83–88PubMed Maran A, Khosla S, Riggs BL, Zhang M, Ritman EL, Turner RT (2003) Measurement of gene expression following cryogenic mu-CT scanning of human iliac crest biopsies. J Musculoskelet Neuronal Interact 3:83–88PubMed
Zurück zum Zitat McElderry JD, Kole MR, Morris MD (2011) Repeated freeze-thawing of bone tissue affects Raman bone quality measurements. J Biomed Opt 16:071407CrossRef McElderry JD, Kole MR, Morris MD (2011) Repeated freeze-thawing of bone tissue affects Raman bone quality measurements. J Biomed Opt 16:071407CrossRef
Zurück zum Zitat Middlebrooks JC, Snyder RL (2007) Auditory prosthesis with a penetrating nerve array. J Assoc Res Otolaryngol 8:258–279CrossRef Middlebrooks JC, Snyder RL (2007) Auditory prosthesis with a penetrating nerve array. J Assoc Res Otolaryngol 8:258–279CrossRef
Zurück zum Zitat Morita K, Doi K, Oue H, Kajihara S, Hayashi K, Akagawa Y (2013) Influence of formalin fixation on the implant stability quotient and mechanical characteristics of bone. Br J Oral Maxillofac Surg 51:550–554CrossRef Morita K, Doi K, Oue H, Kajihara S, Hayashi K, Akagawa Y (2013) Influence of formalin fixation on the implant stability quotient and mechanical characteristics of bone. Br J Oral Maxillofac Surg 51:550–554CrossRef
Zurück zum Zitat Peake WT, Rosowski JJ, Lynch TJ (1992) Middle-ear transmission: acoustic versus ossicular coupling in cat and human. Hear Res 57:245–268CrossRef Peake WT, Rosowski JJ, Lynch TJ (1992) Middle-ear transmission: acoustic versus ossicular coupling in cat and human. Hear Res 57:245–268CrossRef
Zurück zum Zitat Poznyakovskiy AA, Zahnert T, Kalaidzidis Y, Schmidt R, Fischer B, Baumgart J, Yarin YM (2008) The creation of geometric three-dimensional models of the inner ear based on micro computer tomography data. Hear Res 243:95–104CrossRef Poznyakovskiy AA, Zahnert T, Kalaidzidis Y, Schmidt R, Fischer B, Baumgart J, Yarin YM (2008) The creation of geometric three-dimensional models of the inner ear based on micro computer tomography data. Hear Res 243:95–104CrossRef
Zurück zum Zitat Schuknecht H (1993) Pathology of the inner ear, 2nd edn. Lea & Febiger, Philadelphia Schuknecht H (1993) Pathology of the inner ear, 2nd edn. Lea & Febiger, Philadelphia
Zurück zum Zitat Scruggs JL, Flatland B, Reed A (2014) Effects of freezing on tissue factor activity in a thromboelastography assay. Vet Clin Pathol 43:322–325CrossRef Scruggs JL, Flatland B, Reed A (2014) Effects of freezing on tissue factor activity in a thromboelastography assay. Vet Clin Pathol 43:322–325CrossRef
Zurück zum Zitat Seidel A, Bergauer B, Lell M, Buder T, von Wilmowsky C, Dach E, Wichmann M, Matta RE (2018) Does formalin fixation influence MSCT/CBCT accuracy? Surg Radiol Anat 40:31–37CrossRef Seidel A, Bergauer B, Lell M, Buder T, von Wilmowsky C, Dach E, Wichmann M, Matta RE (2018) Does formalin fixation influence MSCT/CBCT accuracy? Surg Radiol Anat 40:31–37CrossRef
Zurück zum Zitat Smith ZM, Delgutte B (2007) Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants. J Assoc Res Otolaryngol 8:134–151CrossRef Smith ZM, Delgutte B (2007) Using evoked potentials to match interaural electrode pairs with bilateral cochlear implants. J Assoc Res Otolaryngol 8:134–151CrossRef
Zurück zum Zitat Tirko NN, Ryugo DK (2012) Synaptic plasticity in the medial superior olive of hearing, deaf, and cochlear-implanted cats. J Comp Neurol 520:2202–2217CrossRef Tirko NN, Ryugo DK (2012) Synaptic plasticity in the medial superior olive of hearing, deaf, and cochlear-implanted cats. J Comp Neurol 520:2202–2217CrossRef
Zurück zum Zitat Uzun H, Curthoys IS, Jones AS (2007) A new approach to visualizing the membranous structures of the inner ear—high resolution X-ray micro-tomography. Acta Otolaryngol 127:568–573CrossRef Uzun H, Curthoys IS, Jones AS (2007) A new approach to visualizing the membranous structures of the inner ear—high resolution X-ray micro-tomography. Acta Otolaryngol 127:568–573CrossRef
Zurück zum Zitat van der Made AD, Maas M, Beenen LF, Oostra RJ, Kerkhoffs GM (2013) Postmortem imaging exposed: an aid in MR imaging of musculoskeletal structures. Skelet Radiol 42:467–472CrossRef van der Made AD, Maas M, Beenen LF, Oostra RJ, Kerkhoffs GM (2013) Postmortem imaging exposed: an aid in MR imaging of musculoskeletal structures. Skelet Radiol 42:467–472CrossRef
Zurück zum Zitat Wehrl HF, Bezrukov I, Wiehr S, Lehnhoff M, Fuchs K, Mannheim JG, Quintanilla-Martinez L, Kohlhofer U, Kneilling M, Pichler BJ, Sauter AW (2015) Assessment of murine brain tissue shrinkage caused by different histological fixatives using magnetic resonance and computed tomography imaging. Histol Histopathol 30:601–613PubMed Wehrl HF, Bezrukov I, Wiehr S, Lehnhoff M, Fuchs K, Mannheim JG, Quintanilla-Martinez L, Kohlhofer U, Kneilling M, Pichler BJ, Sauter AW (2015) Assessment of murine brain tissue shrinkage caused by different histological fixatives using magnetic resonance and computed tomography imaging. Histol Histopathol 30:601–613PubMed
Zurück zum Zitat Wei Z, Niu Q, Zhang F, Xiao K, Liu L, Wang Y, Jia J, Cao J, Fu S, Yun K (2017) The effect of sodium fluoride, formaldehyde, and storage temperature on the stability of methamidophos in post-mortem blood and liver. Int J Legal Med 131:667–675CrossRef Wei Z, Niu Q, Zhang F, Xiao K, Liu L, Wang Y, Jia J, Cao J, Fu S, Yun K (2017) The effect of sodium fluoride, formaldehyde, and storage temperature on the stability of methamidophos in post-mortem blood and liver. Int J Legal Med 131:667–675CrossRef
Metadaten
Titel
Influence of storage on the quality of conventional CT and µCT-imaging for the middle and inner cat ear
verfasst von
Tobias Beck
T. Kilchling
S. Reese
A. Brühschwein
Andrea Meyer-Lindenberg
Publikationsdatum
14.11.2019
Verlag
Springer Singapore
Erschienen in
Anatomical Science International / Ausgabe 2/2020
Print ISSN: 1447-6959
Elektronische ISSN: 1447-073X
DOI
https://doi.org/10.1007/s12565-019-00509-y

Weitere Artikel der Ausgabe 2/2020

Anatomical Science International 2/2020 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.