Skip to main content
Erschienen in: European Radiology 7/2003

01.07.2003 | Physics

Investigation into patient doses for intravenous urography and proposed Irish diagnostic reference levels

verfasst von: E. M. Carroll, P. C. Brennan

Erschienen in: European Radiology | Ausgabe 7/2003

Einloggen, um Zugang zu erhalten

Abstract.

With the introduction of Council Directive 97/43/Euratom, all member states should establish relevant diagnostic reference levels for X-ray examinations. Diagnostic reference levels help to facilitate standardisation and optimisation within departments and attempt to reduce dose variations between hospitals. High variation of individual patient doses for plain-film examinations by up to a factor of 75 was demonstrated by a previous Irish study, which highlighted the necessity for further investigation into other examinations in Ireland. The current work aimed to establish reference values for intravenous urography (IVU) examinations, an important contributor to collective dose. Eleven Irish hospitals were randomly selected, representing 30% of the total number of hospitals. Dose-area product (DAP) readings for IVUs were recorded along with technical and procedural details. Resultant data demonstrated mean hospital and individual patient DAP variations of a factor of 4 and 58, respectively. Stepwise regression analysis demonstrated that number of images taken, method of image acquisition and patient weight were the main causal agents for dose variations recorded. A proposed diagnostic reference level of 12 Gy cm2 was established at the level of the third-quartile value of the mean hospital DAP values. This article provides evidence of large variations in DAP values for IVU examinations. It is hoped that application of the proposed DRL of 12 Gy cm2 will reduce the size of these variations.
Literatur
1.
Zurück zum Zitat Council Directive 97/43/Euratom. Health protection of individuals against the dangers of ionizing radiation in relation to medical exposure, and repealing Directive 84/ 466/ Euratom Council Directive 97/43/Euratom. Health protection of individuals against the dangers of ionizing radiation in relation to medical exposure, and repealing Directive 84/ 466/ Euratom
2.
Zurück zum Zitat Institute of Physical Sciences in Medicine, National Radiological Protection Board, College of Radiographers (1992) National Protocol for Patient Dose Measurements in Diagnostic Radiology, The National Radiological Protection Board, Oxon Institute of Physical Sciences in Medicine, National Radiological Protection Board, College of Radiographers (1992) National Protocol for Patient Dose Measurements in Diagnostic Radiology, The National Radiological Protection Board, Oxon
3.
Zurück zum Zitat Warren-Forward HM, Haddaway MJ, Temperton DH, McCall IW (1998) Dose-area product readings for fluoroscopic and plain film examinations, including analysis of the source of variation for barium enema examinations. Br J Radiol 71:961–967CrossRefPubMed Warren-Forward HM, Haddaway MJ, Temperton DH, McCall IW (1998) Dose-area product readings for fluoroscopic and plain film examinations, including analysis of the source of variation for barium enema examinations. Br J Radiol 71:961–967CrossRefPubMed
4.
Zurück zum Zitat Johnston DA, Brennan PC (2000) Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals. Br J Radiol 73:396–402CrossRefPubMed Johnston DA, Brennan PC (2000) Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals. Br J Radiol 73:396–402CrossRefPubMed
5.
Zurück zum Zitat Contento G, Malisan MR, Padovani R, Maccia C, Wall F, Shrimpton PC (1998) A comparison of diagnostic radiology practice and patient exposure in Britain, France and Italy. Br J Radiol 61:143–152CrossRef Contento G, Malisan MR, Padovani R, Maccia C, Wall F, Shrimpton PC (1998) A comparison of diagnostic radiology practice and patient exposure in Britain, France and Italy. Br J Radiol 61:143–152CrossRef
6.
Zurück zum Zitat Hart D, Hillier MC, Wall BF, Shrimpton PC, Bungay D (1996) Dose to patients from medical X-ray examinations in the UK 1995 review, NRPB-R289. National Radiological Protection Board, Oxon Hart D, Hillier MC, Wall BF, Shrimpton PC, Bungay D (1996) Dose to patients from medical X-ray examinations in the UK 1995 review, NRPB-R289. National Radiological Protection Board, Oxon
7.
Zurück zum Zitat National Radiological Protection Board (2002) Radiation exposure of the UK population from medical and dental X-ray examinations, NRPB-W4. National Radiological Protection Board, Oxon National Radiological Protection Board (2002) Radiation exposure of the UK population from medical and dental X-ray examinations, NRPB-W4. National Radiological Protection Board, Oxon
8.
Zurück zum Zitat European Commission (1999) Radiation Protection 109 Guidance on diagnostic reference dose levels (DRLs) for medical exposure. European Communities Publications European Commission (1999) Radiation Protection 109 Guidance on diagnostic reference dose levels (DRLs) for medical exposure. European Communities Publications
9.
Zurück zum Zitat Muller M, Heicappell R, Steiner U, Merkle E, Aschoff AJ, Miller K (1998) The average dose-area product at intravenous urography in 205 adults. Br J Radiol 71:210–212CrossRefPubMed Muller M, Heicappell R, Steiner U, Merkle E, Aschoff AJ, Miller K (1998) The average dose-area product at intravenous urography in 205 adults. Br J Radiol 71:210–212CrossRefPubMed
10.
Zurück zum Zitat Daniels SJ, Brennan PC (1996) A comparison of tomography and zonography during intravenous urography. Radiography 2:99–109CrossRef Daniels SJ, Brennan PC (1996) A comparison of tomography and zonography during intravenous urography. Radiography 2:99–109CrossRef
11.
Zurück zum Zitat Busch HP, Georgi M (1992) Digital radiography: clinical experience with digital image intensifier and storage phosphor radiography, Blackwell, Berlin Busch HP, Georgi M (1992) Digital radiography: clinical experience with digital image intensifier and storage phosphor radiography, Blackwell, Berlin
12.
Zurück zum Zitat Kopp J, Maiter W, Losereit C (1995) Radiation exposure of patients by using modern digital fluoroscopy systems. Radiat Prot Dosim 57:487–488 Kopp J, Maiter W, Losereit C (1995) Radiation exposure of patients by using modern digital fluoroscopy systems. Radiat Prot Dosim 57:487–488
Metadaten
Titel
Investigation into patient doses for intravenous urography and proposed Irish diagnostic reference levels
verfasst von
E. M. Carroll
P. C. Brennan
Publikationsdatum
01.07.2003
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 7/2003
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-002-1792-5

Weitere Artikel der Ausgabe 7/2003

European Radiology 7/2003 Zur Ausgabe

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.