Skip to main content
Erschienen in: European Radiology 9/2016

17.12.2015 | Computed Tomography

Iodine concentration as a perfusion surrogate marker in oncology: Further elucidation of the underlying mechanisms using Volume Perfusion CT with 80 kVp

verfasst von: Wolfgang M. Thaiss, Ulrike Haberland, Sascha Kaufmann, Daniel Spira, Christoph Thomas, Konstantin Nikolaou, Marius Horger, Alexander W. Sauter

Erschienen in: European Radiology | Ausgabe 9/2016

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To assess the value of iodine concentration (IC) in computed tomography data acquired with 80 kVp, as a surrogate for perfusion imaging in hepatocellular carcinoma (HCC) and lymphoma by comparing iodine related attenuation (IRA) with quantitative Volume Perfusion CT (VPCT)-parameters.

Methods

VPCT-parameters were compared with intra-tumoral IC at 5 time points after the aortic peak enhancement (APE) with a temporal resolution of 3.5 sec in untreated 30 HCC and 30 lymphoma patients.

Results

Intra-tumoral perfusion parameters for HCC showed a blood flow (BF) of 52.7 ± 17.0 mL/100 mL/min, blood volume (BV) 12.6 ± 4.3 mL/100 mL, arterial liver perfusion (ALP) 44.4 ± 12.8 mL/100 mL/min. Lesion IC 7 sec after APE was 133.4 ± 57.3 mg/100 mL. Lymphoma showed a BF of 36.8 ± 13.4 mL/100 mL/min, BV of 8.8 ± 2.8 mL/100 mL and IC of 118.2 ± 64.5 mg/100 mL 3.5 sec after APE. Strongest correlations exist for VPCT-derived BF and ALP with IC in HCC 7 sec after APE (r = 0.71 and r = 0.84) and 3.5 sec after APE in lymphoma lesions (r = 0.77). Significant correlations are also present for BV (r = 0.60 and r = 0.65 for HCC and lymphoma, respectively).

Conclusions

We identified a good, time-dependent agreement between VPCT-derived flow values and IC in HCC and lymphoma. Thus, CT-derived ICs 7 sec after APE in HCC and 3.5 sec in lymphoma may be used as surrogate imaging biomarkers for tumor perfusion with 80 kVp.

Key points

Iodine concentration derived from low kVp CT is regarded as perfusion surrogate
Correlation with Perfusion CT was performed to elucidate timing and histology dependencies
Highest correlation was present 7 sec after aortic peak enhancement in hepatocellular carcinoma
In lymphoma, highest correlation was calculated 3.5 sec after aortic peak enhancement
With these results, further optimization of Dual energy CT protocols is possible
Literatur
1.
2.
Zurück zum Zitat Davarpanah AH, Weinreb JC (2013) The role of imaging in hepatocellular carcinoma: the present and future. J Clin Gastroenterol 47:S7–S10CrossRefPubMed Davarpanah AH, Weinreb JC (2013) The role of imaging in hepatocellular carcinoma: the present and future. J Clin Gastroenterol 47:S7–S10CrossRefPubMed
3.
Zurück zum Zitat Ippolito D, Sironi S, Pozzi M et al (2008) Hepatocellular carcinoma in cirrhotic liver disease: functional computed tomography with perfusion imaging in the assessment of tumor vascularization. Acad Radiol 15:919–927CrossRefPubMed Ippolito D, Sironi S, Pozzi M et al (2008) Hepatocellular carcinoma in cirrhotic liver disease: functional computed tomography with perfusion imaging in the assessment of tumor vascularization. Acad Radiol 15:919–927CrossRefPubMed
4.
Zurück zum Zitat Miles KA, Charnsangavej C, Lee FT, Fishman EK, Horton K, Lee TY (2000) Application of CT in the investigation of angiogenesis in oncology. Acad Radiol 7:840–850CrossRefPubMed Miles KA, Charnsangavej C, Lee FT, Fishman EK, Horton K, Lee TY (2000) Application of CT in the investigation of angiogenesis in oncology. Acad Radiol 7:840–850CrossRefPubMed
5.
Zurück zum Zitat Miles KA (2003) Perfusion CT for the assessment of tumour vascularity: which protocol? Br J Radiol 76:S36–S42CrossRefPubMed Miles KA (2003) Perfusion CT for the assessment of tumour vascularity: which protocol? Br J Radiol 76:S36–S42CrossRefPubMed
6.
Zurück zum Zitat Kambadakone AR, Sahani DV (2009) Body perfusion CT: technique, clinical applications, and advances. Radiol Clin N Am 47:161–178CrossRefPubMed Kambadakone AR, Sahani DV (2009) Body perfusion CT: technique, clinical applications, and advances. Radiol Clin N Am 47:161–178CrossRefPubMed
7.
Zurück zum Zitat Petralia G, Preda L, D'Andrea G et al (2010) CT perfusion in solid-body tumours. Part I: technical issues. Radiol Med 115:843–857CrossRefPubMed Petralia G, Preda L, D'Andrea G et al (2010) CT perfusion in solid-body tumours. Part I: technical issues. Radiol Med 115:843–857CrossRefPubMed
8.
Zurück zum Zitat Ippolito D, Capraro C, Casiraghi A, Cestari C, Sironi S (2012) Quantitative assessment of tumour associated neovascularisation in patients with liver cirrhosis and hepatocellular carcinoma: role of dynamic-CT perfusion imaging. Eur Radiol 22:803–811CrossRefPubMed Ippolito D, Capraro C, Casiraghi A, Cestari C, Sironi S (2012) Quantitative assessment of tumour associated neovascularisation in patients with liver cirrhosis and hepatocellular carcinoma: role of dynamic-CT perfusion imaging. Eur Radiol 22:803–811CrossRefPubMed
9.
Zurück zum Zitat Ippolito D, Fior D, Bonaffini PA et al (2014) Quantitative evaluation of CT-perfusion map as indicator of tumor response to transarterial chemoembolization and radiofrequency ablation in HCC patients. Eur J Radiol 83:1665–1671CrossRefPubMed Ippolito D, Fior D, Bonaffini PA et al (2014) Quantitative evaluation of CT-perfusion map as indicator of tumor response to transarterial chemoembolization and radiofrequency ablation in HCC patients. Eur J Radiol 83:1665–1671CrossRefPubMed
10.
Zurück zum Zitat Syha R, Grunwald L, Horger T et al (2014) Assessment of the nature of residual masses at end of treatment in lymphoma patients using volume perfusion computed tomography. Eur Radiol 24:770–779CrossRefPubMed Syha R, Grunwald L, Horger T et al (2014) Assessment of the nature of residual masses at end of treatment in lymphoma patients using volume perfusion computed tomography. Eur Radiol 24:770–779CrossRefPubMed
11.
Zurück zum Zitat Spira D, Adam P, Linder C et al (2012) Perfusion and flow extraction product as potential discriminators in untreated follicular and diffuse large B cell lymphomas using volume perfusion CT with attempt at histopathologic explanation. AJR Am J Roentgenol 198:1239–1246CrossRefPubMed Spira D, Adam P, Linder C et al (2012) Perfusion and flow extraction product as potential discriminators in untreated follicular and diffuse large B cell lymphomas using volume perfusion CT with attempt at histopathologic explanation. AJR Am J Roentgenol 198:1239–1246CrossRefPubMed
12.
Zurück zum Zitat Mileto A, Mazziotti S, Gaeta M et al (2012) Pancreatic dual-source dual-energy CT: is it time to discard unenhanced imaging? Clin Radiol 67:334–339CrossRefPubMed Mileto A, Mazziotti S, Gaeta M et al (2012) Pancreatic dual-source dual-energy CT: is it time to discard unenhanced imaging? Clin Radiol 67:334–339CrossRefPubMed
13.
Zurück zum Zitat Graser A, Becker CR, Staehler M et al (2010) Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant. Investig Radiol 45:399–405 Graser A, Becker CR, Staehler M et al (2010) Single-phase dual-energy CT allows for characterization of renal masses as benign or malignant. Investig Radiol 45:399–405
14.
Zurück zum Zitat Apfaltrer P, Meyer M, Meier C et al (2012) Contrast-enhanced dual-energy CT of gastrointestinal stromal tumors: is iodine-related attenuation a potential indicator of tumor response? Investig Radiol 47:65–70CrossRef Apfaltrer P, Meyer M, Meier C et al (2012) Contrast-enhanced dual-energy CT of gastrointestinal stromal tumors: is iodine-related attenuation a potential indicator of tumor response? Investig Radiol 47:65–70CrossRef
15.
Zurück zum Zitat Lee JA, Jeong WK, Kim Y et al (2013) Dual-energy CT to detect recurrent HCC after TACE: initial experience of color-coded iodine CT imaging. Eur J Radiol 82:569–576CrossRefPubMed Lee JA, Jeong WK, Kim Y et al (2013) Dual-energy CT to detect recurrent HCC after TACE: initial experience of color-coded iodine CT imaging. Eur J Radiol 82:569–576CrossRefPubMed
16.
Zurück zum Zitat Chandler A, Wei W, Anderson EF, Herron DH, Ye Z, Ng CS (2012) Validation of motion correction techniques for liver CT perfusion studies. Br J Radiol 85:e514–e522CrossRefPubMedPubMedCentral Chandler A, Wei W, Anderson EF, Herron DH, Ye Z, Ng CS (2012) Validation of motion correction techniques for liver CT perfusion studies. Br J Radiol 85:e514–e522CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Kaufmann S, Horger T, Oelker A et al (2015) Characterization of hepatocellular carcinoma (HCC) lesions using a novel CT-based volume perfusion (VPCT) technique. Eur J Radiol 84:1029–1035CrossRefPubMed Kaufmann S, Horger T, Oelker A et al (2015) Characterization of hepatocellular carcinoma (HCC) lesions using a novel CT-based volume perfusion (VPCT) technique. Eur J Radiol 84:1029–1035CrossRefPubMed
18.
Zurück zum Zitat Spira D, Grunwald L, Vogel W et al (2014) Midtreatment evaluation of lymphoma response to chemotherapy by volume perfusion computed tomography. J Comput Assist Tomogr 38:123–130CrossRefPubMed Spira D, Grunwald L, Vogel W et al (2014) Midtreatment evaluation of lymphoma response to chemotherapy by volume perfusion computed tomography. J Comput Assist Tomogr 38:123–130CrossRefPubMed
19.
Zurück zum Zitat Thomas C, Heuschmid M, Schilling D et al (2010) Urinary calculi composed of uric acid, cystine, and mineral salts: differentiation with dual-energy CT at a radiation dose comparable to that of intravenous pyelography. Radiology 257:402–409CrossRefPubMed Thomas C, Heuschmid M, Schilling D et al (2010) Urinary calculi composed of uric acid, cystine, and mineral salts: differentiation with dual-energy CT at a radiation dose comparable to that of intravenous pyelography. Radiology 257:402–409CrossRefPubMed
20.
Zurück zum Zitat Marin D, Boll DT, Mileto A, Nelson RC (2014) State of the art: dual-energy CT of the abdomen. Radiology 271:327–342CrossRefPubMed Marin D, Boll DT, Mileto A, Nelson RC (2014) State of the art: dual-energy CT of the abdomen. Radiology 271:327–342CrossRefPubMed
21.
Zurück zum Zitat Ippolito D, Sironi S, Pozzi M et al (2008) Perfusion computed tomographic assessment of early hepatocellular carcinoma in cirrhotic liver disease: initial observations. J Comput Assist Tomogr 32:855–858CrossRefPubMed Ippolito D, Sironi S, Pozzi M et al (2008) Perfusion computed tomographic assessment of early hepatocellular carcinoma in cirrhotic liver disease: initial observations. J Comput Assist Tomogr 32:855–858CrossRefPubMed
22.
Zurück zum Zitat Spira D, Schulze M, Sauter A et al (2012) Volume perfusion-CT of the liver: insights and applications. Eur J Radiol 81:1471–1478CrossRefPubMed Spira D, Schulze M, Sauter A et al (2012) Volume perfusion-CT of the liver: insights and applications. Eur J Radiol 81:1471–1478CrossRefPubMed
23.
Zurück zum Zitat Ippolito D, Sironi S, Pozzi M et al (2010) Perfusion CT in cirrhotic patients with early stage hepatocellular carcinoma: assessment of tumor-related vascularization. Eur J Radiol 73:148–152CrossRefPubMed Ippolito D, Sironi S, Pozzi M et al (2010) Perfusion CT in cirrhotic patients with early stage hepatocellular carcinoma: assessment of tumor-related vascularization. Eur J Radiol 73:148–152CrossRefPubMed
24.
Zurück zum Zitat Li Y, Shi G, Wang S, Wang S, Wu R (2013) Iodine quantification with dual-energy CT: phantom study and preliminary experience with VX2 residual tumour in rabbits after radiofrequency ablation. Br J Radiol 86:20130143CrossRefPubMedPubMedCentral Li Y, Shi G, Wang S, Wang S, Wu R (2013) Iodine quantification with dual-energy CT: phantom study and preliminary experience with VX2 residual tumour in rabbits after radiofrequency ablation. Br J Radiol 86:20130143CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Harders SW, Madsen HH, Nellemann HM et al (2013) Dynamic contrast-enhanced CT in suspected lung cancer: quantitative results. Br J Radiol 86:20130257CrossRefPubMedPubMedCentral Harders SW, Madsen HH, Nellemann HM et al (2013) Dynamic contrast-enhanced CT in suspected lung cancer: quantitative results. Br J Radiol 86:20130257CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Shi J, Schmid-Bindert G, Fink C et al (2013) Dynamic volume perfusion CT in patients with lung cancer: baseline perfusion characteristics of different histological subtypes. Eur J Radiol 82:e894–e900CrossRefPubMed Shi J, Schmid-Bindert G, Fink C et al (2013) Dynamic volume perfusion CT in patients with lung cancer: baseline perfusion characteristics of different histological subtypes. Eur J Radiol 82:e894–e900CrossRefPubMed
27.
Zurück zum Zitat Sun X, Liu C, Liang C, Sun C, Liu S, Deng K (2009) Hepatocellular carcinomas: correlation between time to peak hepatocellular carcinomas enhancement and time to peak aortic enhancement. Comput Med Imaging Graph 33:312–316CrossRefPubMed Sun X, Liu C, Liang C, Sun C, Liu S, Deng K (2009) Hepatocellular carcinomas: correlation between time to peak hepatocellular carcinomas enhancement and time to peak aortic enhancement. Comput Med Imaging Graph 33:312–316CrossRefPubMed
28.
Zurück zum Zitat Knobloch G, Jost G, Huppertz A, Hamm B, Pietsch H (2014) Dual-energy computed tomography for the assessment of early treatment effects of regorafenib in a preclinical tumor model: comparison with dynamic contrast-enhanced CT and conventional contrast-enhanced single-energy CT. Eur Radiol 24:1896–1905CrossRefPubMed Knobloch G, Jost G, Huppertz A, Hamm B, Pietsch H (2014) Dual-energy computed tomography for the assessment of early treatment effects of regorafenib in a preclinical tumor model: comparison with dynamic contrast-enhanced CT and conventional contrast-enhanced single-energy CT. Eur Radiol 24:1896–1905CrossRefPubMed
29.
Zurück zum Zitat McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology 276:637–653CrossRefPubMedPubMedCentral McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology 276:637–653CrossRefPubMedPubMedCentral
Metadaten
Titel
Iodine concentration as a perfusion surrogate marker in oncology: Further elucidation of the underlying mechanisms using Volume Perfusion CT with 80 kVp
verfasst von
Wolfgang M. Thaiss
Ulrike Haberland
Sascha Kaufmann
Daniel Spira
Christoph Thomas
Konstantin Nikolaou
Marius Horger
Alexander W. Sauter
Publikationsdatum
17.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 9/2016
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-015-4154-9

Weitere Artikel der Ausgabe 9/2016

European Radiology 9/2016 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.