The left ventricular assist device (LVAD) has become an established treatment option for patients with refractory heart failure. Many of these patients experience chronic kidney disease (CKD) due to chronic cardiorenal syndrome type II, which is often alleviated quickly following LVAD implantation. Nevertheless, reversibility of CKD remains difficult to predict. Interestingly, initial recovery of GFR appears to be transient, being followed by gradual but significant late decline. Nevertheless, GFR often remains elevated compared to preimplant status. Larger GFR increases are followed by a proportionally larger late decline. Several explanations for this gradual decline in renal function after LVAD therapy have been proposed, yet a definitive answer remains elusive. Mortality predictors of LVAD implantation are the occurrence of either postimplantation acute kidney injury (AKI) or preimplant CKD. However, patient outcomes continue to improve as LVAD therapy becomes more widespread, and adverse events including AKI appear to decline. In light of a growing destination therapy population, it is important to understand the cumulative effects of long-term LVAD support on kidney function. Additional research and passage of time are required to further unravel the intricate relationships between the LVAD and the kidney.

Introduction

Approximately 1–2 % of the adult population in developed countries suffers from heart failure (HF) [1]. In the USA, an estimated 5.7 million people suffer from HF [2], whereas worldwide the number of HF patients exceeds 23 million [3]. Although most cases can be managed pharmacologically and/or surgically, HF may progress and become unresponsive to conventional treatment [4]. For these refractory HF patients, encompassing an estimated 5–10 % of the total HF population [5], heart transplantation (HTx) is currently the gold standard of treatment [4, 68]. However, HTx is limited by availability of donor hearts [7] and patients may not always meet criteria for placement on waiting lists [4]. Eurotransplant reported an increasing number of patients waiting for HTx, a trend unmatched by donor heart availability [9]. Consequently, waiting list mortality remains too high [10, 11].
Implantable left ventricular assist devices (LVAD) have revolutionized treatment of late-stage systolic HF [7, 12]. An LVAD is an implantable mechanical circulatory support (MCS) device, powered by an external driveline cable, which aids the failing heart by unloading the left (or right) ventricle. In 2001, the pivotal REMATCH trial showed that LVAD therapy was superior to maximal medical therapy: 1-year survival rate of the LVAD group doubled that of the control group receiving such therapy (52 vs. 25 %) [13]. Although LVADs were first accepted to support patients awaiting HTx, the so-called bridge to transplantation therapy, they are now increasingly being offered to patients ineligible for HTx. Such destination therapy (DT) can be seen as an alternative to HTx [14, 15]. It has to be noted that some patients initially intended for DT may improve sufficiently to become HTx eligible again, the bridge to candidacy population. This implies that the division between bridge to transplantation therapy and DT is not always entirely black and white.
The first-generation LVAD pumps were large and pneumatically driven, creating pulsatile-flow (pf). However, these devices showed many adverse events. The new generation of continuous-flow (cf) pumps is smaller, more durable and shows a considerably improved safety profile [16]. Moreover, cf-LVADs are easier to implant, operate silently, but create high shear stress and areas of stasis [17]. Retrospective analysis of large patient samples has shown that cf-LVADs offer superior survival over pf-LVADs with fewer adverse events [16] and at lower cost [18]. However, the non-physiologic nature of these devices has been topic of debate. Since 2010, continuous-flow devices accounted for over 99 % of LVADs implanted in the USA [16].
Many LVAD patients experience renal impairment secondary to HF, prior to pump placement. Baseline eGFR, at the time of LVAD implantation, averages 60 (±35) mL/min/1.73 m2 [19]. HF combined with chronic kidney disease (CKD) is significant public health problems with increasing overlap [20]. Two out of three patients hospitalized for HF also present with CKD [21], defined as estimated creatinine clearance <60 mL/min/1.73 m2. Cardiorenal syndrome (CRS) refers to a group of acute and chronic clinical conditions in which failure of either heart or kidney initiates or aggravates failure of the other organ [22]. Increased efforts are directed toward classification, identification and understanding of the pathogenesis of combined heart and kidney diseases [23]. The subtypes of CRS are categorized depending on primary organ dysfunction and acute versus chronic onset [24], as shown in Table 1. However, it should be noted that the validity of this classification is under debate [22].
Table 1
Classification of cardiorenal syndromes
Cardiorenal syndrome (CRS) general definition
 A pathophysiologic disorder of the heart and kidneys whereby acute or chronic dysfunction in one organ may induce acute or chronic dysfunction in the other organ
CRS type I (acute cardiorenal syndrome)
 Abrupt worsening of cardiac function (e.g., acute cardiogenic shock or acutely decompensated congestive heart failure) leading to acute kidney injury
CRS type II (chronic cardiorenal syndrome)
 Chronic abnormalities in cardiac function (e.g., chronic congestive heart failure) causing progressive and potentially permanent chronic kidney disease
CRS type III (acute renocardiac syndrome)
 Abrupt worsening of renal function (e.g., acute kidney ischemia or glomerulonephritis) causing acute cardiac disorder [e.g., heart failure, arrhythmia, ischemia)
CRS type IV (chronic renocardiac syndrome)
 Chronic kidney disease (e.g., chronic glomerular or interstitial disease) contributing to decreased cardiac function, cardiac hypertrophy and/or increased risk of adverse cardiovascular events
CRS type V (secondary cardiorenal syndrome)
 Systemic condition (e.g., diabetes mellitus, sepsis) causing both cardiac and renal dysfunction
Adapted from McCullough et al. [24]

Cardiorenal syndrome type II

The fact that many patients hospitalized for HF also present with CKD can mainly be explained by the pathophysiology of CRS type II. The pathophysiology of chronic CRS type II (CKD on top of HF) is largely derived from animal studies since it is difficult to exclude confounding factors and establish temporal relationships in humans [25]. Proposed pathophysiological mechanisms include neurohormonal activation, hemodynamic factors such as renal hypoperfusion and venous congestion, inflammation and oxidative stress [25]; mechanisms are summarized in Fig. 1. In CRS type II, chronic abnormalities in cardiac function can cause progressive and permanent kidney injury [25].
The first established cardiorenal connectors were hemodynamic factors [22]. Significant increases in renal venous pressure are transmitted to intratubular pressure, which directly decreases net filtration pressure, thereby diminishing GFR. Venous congestion resulting from inadequate left ventricular output has been reported as the most important hemodynamic factor resulting in worsening renal function in advanced HF patients [2427].
However, chronic CRS type II cannot only be explained by hemodynamic factors [22]. Falling cardiac output and reduced renal perfusion results in activation of both the sympathetic nervous system and the renin angiotensin aldosterone system (RAAS) [28]. It has been shown that renal venous hypertension can induce RAAS activation, independent of changes in systolic blood pressure (BP) and flow [25]. Water and sodium retention resulting from RAAS activation will increase fluid volume and thus workload of the already faltering heart. Heart and kidney can subsequently enter a vicious circle, inevitably leading to decompensated HF. It has been proposed that activation of the sympathetic nervous system and local angiotensin II stimulates NADPH oxidase-dependent reactive oxygen species generation in the kidney, leading to podocyte injury and albuminuria [29]. Moreover, paracrine aldosterone signaling can provoke oxidative stress, which can lead to renal fibrosis [25].
Another non-hemodynamic factor contributing to CKD in HF patients is an inflammatory response in the kidneys. Cardiac monocytes, under stress of mechanical stretch or ischemia, can produce pro-inflammatory cytokines that may have distant effects on the kidneys [25]. In addition, venous congestion may precipitate intestinal ischemia, enhancing translocation of intestinal endotoxin-containing bacteria into the bloodstream [30], leading to a pro-inflammatory state [25].
There has been increasing interest in new biomarkers such as NGAL, KIM-1 and L-FABP (depicted in Fig. 1) to assess and predict renal injury [31, 32]. However, these biomarkers are not (yet) in routine use in the clinic and will therefore not be further explored in this review.

Preimplant renal function and survival

Baseline eGFR prior to LVAD implantation averages 60 (±35) mL/min/1.73 m2 [19]. Severity of preimplant renal dysfunction is inversely related to postimplant survival [16]. Kirklin et al. [33] retrospectively analyzed the Interagency Registry for Mechanical Circulatory Support (INTERMACS) database and concluded that preimplant renal dysfunction (RD) predicts higher mortality after LVAD-implant. This has been confirmed by studies in Europe and Asia [34, 35]. In a study not limited to LVAD patients, Hillege et al. [36] drew a similar conclusion: RD in HF patients predicts longer hospitalization and worse long-term survival outcomes. This reduced survival of patients with severe preimplant RD is most pronounced in the early postoperative course: After the initial postoperative period, death rates appear independent of preimplant RD [33].
Since preimplant RD increases early postimplant mortality, it is imperative that patients receive timely referral for LVAD therapy, before HF worsens and leads to CKD [37]. In fact, those patients with marked RD tend to represent the old and very sick; subgroups with inherent decreased perioperative survival [38].

Predictor models

In predicting perioperative mortality, renal parameters are incorporated in various risk scoring systems [3942]. As a general rule, RD and high diuretic doses, among others, serve as poor prognostic markers [38]. It has recently been proposed that AKI after implantation serves as a more reliable predictor of mortality in this patient population [43, 44]. This warrants close monitoring of immediate postoperative renal function and minimization of modifiable risk factors for AKI.
Surprisingly, not only the rapid deterioration of renal function, but also a prompt increase in eGFR serves as a marker for increased mortality (Fig. 2a) [19]. Mortality prediction over changes in eGFR therefore appears to follow a U-curve (Fig. 2b). An explanation for this puzzling observation remains elusive. Perhaps relatively healthy patients who already have a near-normal eGFR can only regain a small proportion of their eGFR. These patients experience good survival. In contrast, very sick patients with severely compromised eGFR may initially experience as much as a doubling of eGFR. However, this cohort of very sick patients also experiences higher perioperative mortality.

Patient selection

The fact that patients with preimplant RD have a higher mortality risk, combined with the fact that the majority of these patients nevertheless experience improvement in renal function after LVAD placement, creates a dilemma for the practicing physician concerning patient selection. Some have listed renal disease, marked by serum creatinine (sCr) ≥ 2.5 mg/dL or hemodialysis, as a relative contraindication for LVAD placement [38]. Kirklin et al. [16] show that dialysis prior to LVAD placement is accompanied with a 2.37 mortality hazard ratio. Nevertheless, others argue that patients with severe RD, even requiring renal replacement therapy (RRT) preimplant, need not be excluded from receiving LVADs [4548]. Optimization of renal function prior to LVAD can be achieved by diuretics in an attempt to decrease renal venous congestion [38]. Not all HF patients have irreversible kidney damage; in fact, kidney function improves markedly early following LVAD placement. LVAD therapy has therefore been suggested as bridge to HTx candidacy: Improved circulation should restore renal function sufficiently to be eligible for HTx [49, 50]. Note that eligibility for LVAD therapy depends on many factors, of which renal function is only one [38, 51].
There are no definitive tests that can reliably predict reversibility of RD [52, 53]. Nevertheless, in the acutely decompensated HF population, Brisco et al. [53] show a linear relationship between BUN/creatinine ratio upon admittance, and percentage of patients that experience improved renal function (eGFR improved >20 %) upon return to cardiac compensation. This relationship has not been replicated in the LVAD population.

Initial recovery of renal function

The short-term effects of LVAD therapy on renal function have been widely studied and well documented in various reviews [20, 49]. Renal function generally improves directly after LVAD implantation if decreased GFR is due to low perfusion before implantation [54]. Reduction in sCr from as high as 4.6–1.2 mg/dL has been observed [55]. Most of the recovery tends to occur in the first month after LVAD placement [56] with the most significant improvement occurring in the subpopulation with the most reduced preoperative renal function [56, 105]. Hasin et al. [57] found that 68 % of patients with a preimplant eGFR <60 mL/min showed an improvement in eGFR to above 60 mL/min after the first month. By analyzing the extensive INTERMACS database, Brisco et al. [19] reported a median improvement in eGFR of around 50 % by month 1, with 17 % of the LVAD population even doubling eGFR.
Improvement in renal function after LVAD implantation largely relies on reversal of several factors, both hemodynamic and non-hemodynamic, attributed to chronic CRS type II. The improvement in eGFR after LVAD implantation may in part be through improvement in intrarenal hemodynamics [58] and reversal of renal hypoperfusion [1]. The importance of the effect of hemodynamic factors is underscored by the observation that higher pump speeds at hospital discharge are associated with larger early increases in GFR [57]. It has been found that plasma renin activity and plasma aldosterone decrease significantly from baseline through weeks 4 and 8 following LVAD implantation [59]. This means that RAAS activation in HF is importantly reduced after LVAD implantation [60], providing biochemical confirmation of the improvement in hemodynamic status [49]. In addition, a decrease in sympathetic tone, as measured by renal sympathetic nerve activity, has been measured in animal models [61]. Reduced sympathetic nerve activity may be mediated by the aortic and cardiopulmonary baroreflex system and may lead to a decrease in renal vascular resistance [49]. In humans, plasma epinephrine and plasma norepinephrine levels also decrease after LVAD implantation [62].
In patients with near-normal preimplant renal function, these early improvements are less pronounced [63]. Butler et al. [52] found that the absence of diabetes was the only variable that could predict recovery of renal function post-LVAD, an observation which was confirmed [35]. However, a more recent study did not find diabetes to be a significant predictor of postimplant renal function improvement but indicated older age and smaller kidney size as negative predictors [57]. Brisco et al. [53] retrospectively studied reversibility of RD in a large number of decompensated HF patients and concluded that an elevated BUN/creatinine ratio upon admission could predict improvement of renal function with return to cardiac compensation. At the same time, recurrence of RD was common after discharge. These findings have yet to be replicated in the LVAD patient population.

Renal function in the long run

Interestingly, it appears that no further improvement in renal function occurs from about 1 month after pump placement. In fact, many studies have observed a slow but gradual decrease in renal function several months postimplant [35, 52, 57, 6467], although others failed to observe this phenomenon [56, 63, 68]. Table 2 shows the change in renal function after the period of initial recovery in various studies.
Table 2
Change in renal function after the initial period of recovery following placement of continuous-flow LVAD
Period (weeks)
Change in GFR
How GFR was estimated: mean change over the indicated period of observation
Participants (N)
References
2–12
sCr: 0.8–1.0 mg/dL
43
Jacobs et al. [66]
4–12
eGFR: 87 (±32)–90 (±31)
30
Kamdar et al. [69]
4–12
eGFR: 87 (±28)–78 (±23)
83
Hasin et al. [57]
4–12
eGFR: 84 (±33)–75 (±30)
55
Sandner et al. [70]
2–26
eGFR: 62–74
116
Singh et al. [56]
4–26
sCr: 1.0–1.1 mg/dL
126
Deo et al. [65]
4–26
eGFR: 81 (±33)–63 (±25)
86
Sandner et al. [35]
4–26
"…renal function showed improvements […] stabilizing by approximately 1–2 months of LVAD support with no further change afterward"
309
Russell et al. [63]
Discharge to 52
eGFR: 96–71
27
Feitell et al. [67]
12–52
sCr: 90–100 µmol/mL
85
Lok et al. [64]
eGFR estimated glomerular filtration rate (mL/min/1.73 m2), NA not available, sCr serum creatinine
Brisco et al. [19] analyzed 3,363 patients from the INTERMACS database and concluded that renal function improvement was transient. By 12 months, eGFR was only 6.7 % above the preimplant value. The changes in renal function over time have been schematically represented in Fig. 3.
Of special note are the (hypothetical) developments under phase 4 (dotted lines). The downward trend in GFR initiated after the initial 1- to 2-month peak may continue to decline in the long term. Unfortunately, sufficient reliable data for this time period are lacking. In addition, paired sample analyses combining the development of renal function following consecutive LVAD and HTx in the same patients are scant. Some research suggests that HTx following LVAD leaves the downward trend unaltered [71] although others report that HTx may temporarily increase GFR in patients with prior compromised renal function [72]. Singh et al. [56] retrospectively analyzed the evolution of renal function of 116 patients consecutively undergoing MCS and HTx. They reported a clear decrease in GFR following HTx, due to tacrolimus administration. However, renal outcomes after HTx seemed to be more dependent on the level of renal function achieved during MCS than on the level of renal function before MCS.
Moreover, as shown in Fig. 4, changes in eGFR vary considerably depending on preimplant levels. Patients with eGFR ≤ 60 mL/min experience a net increase up to 1 year after implantation, whereas the eGFR of those patients with good preimplant values (dark blue line) may actually decrease after 1 year. Note that patients with eGFR ≥ 90 mL/min only represent a minority (12 %), and that the majority of patients have an eGFR ≤ 60 mL/min, due to the presence of CRS type II.
Another interesting observation made by Brisco et al. is the fact that patients experiencing the largest increase in eGFR also have the largest subsequent deterioration. Nevertheless, this subpopulation still has a higher eGFR compared to the patients who did not significantly increase filtration after LVAD placement. The ‘volatile’ changes in eGFR displayed in Fig. 5 can provide further evidence for the transient nature of increased GFR directly after initiation of MCS. Note that the rate of GFR decline, on average, is much larger than that expected with age [73], CKD stage 3 [74] or even diabetic kidney disease [75] (declines of ±1, ±1 and ±3.5 mL/min/1.73 m2 per year, respectively). Several explanations for this trend have been proposed, which need not be mutually exclusive, but could in fact work synergistically.

Measurement bias

One explanation for the trend in Fig. 3 is the measurement bias of sCr. End-stage HF patients are often bedridden and show signs of cachexia [57, 76]. Following LVAD placement, exercise capacity is restored, which might lead to an increase in muscle mass. Importantly, this might increase the sCr level, dependent on muscle mass [32]. Measuring GFR using cystatin C, a marker independent of muscle mass, might control for this bias. However, literature on this subject in the LVAD population is lacking.
Another explanation, proposed by Sandner et al. [35], is that patients lose the optimal medical care (particularly fluid balance management) they enjoyed during their hospital stay. Lack of improvement in renal function frequently corresponded with hospital discharge and may thus be attributed in part to inadequate patient self-management.

Hemolysis

Another explanation for the late gradual decrease in renal function is that a sub-clinical level of hemolysis causes tubular damage [77]. Current commonly used devices operate at pump speeds approaching 10,000 and 3,000 rotations per minute (axial- and centrifugal flow, respectively) [78]. Erythrocytes can lyse under high shear stress, created either through pump speed or partial pump thrombosis. Thrombotic plaques may obstruct the inflow cannula and change blood flow patterns in favor of non-laminar flow. This puts erythrocytes under increased shear stress, causing hemolysis which can ultimately lead to kidney injury [79]. Free iron from hemolytic cells can initiate inflammation around the nephrons [77] and free hemoglobin could precipitate with Tamm-Horsfall and cause intratubular obstruction [80]. Moreover, the free hemoglobin could decrease the availability of nitric oxide, leading to renal vasoconstriction and ischemia [77].

Right-sided HF

A serious complication after prolonged LVAD support is right-sided HF [81, 82]. A recent post-market evaluation study showed right HF to occur in 9 % of patients, representing 0.10 events per patient-year [83]. Left ventricular unloading by the LVAD may promptly increase venous return and overload the right ventricle (RV). Increased filling pressure may cause RV overdistension and decrease myocardial perfusion, leading to RV failure. This, in turn, results in venous congestion in the kidneys (and other organs) [82], reducing perfusion and eGFR [27].

Pulsatility

The non-physiological nature of reduced pulsatility in cf-devices has been reported as a possible factor for decreasing renal function [84]. In humans, insufficient data exist on effects of reduced pulsatility on long-term end-organ function, although functions are maintained within normal range for up to 15 months [85]. Surprisingly, analysis of INTERMACS data reveals that gradual late decline in eGFR was observed with both cf-LVADs and pf-LVADs, hinting that gradually declining kidney function cannot solely be attributed to reduced pulsatility [19]. Some studies found no detrimental effects or major differences in renal function comparing cf-LVAD to pf-LVAD patients [19, 63, 86].
Nevertheless, reduced pulsatility most likely induces profound morphological changes in the large vasculature. Animal [87] and human [88, 89] studies have shown that prolonged continuous flow caused significant changes in the aortic wall, including medial degeneration, smooth muscle cell (SMC) disorientation and depletion, elastic fiber fragmentation and depletion, medial fibrosis and atherosclerotic changes [89]. Such changes may translate to decreased peripheral vascular reactivity [90, 91]. It has been suggested that continuous flow leads to stiff and unresponsive arteries [92].
Animal studies report proliferation of SMCs in the afferent arteriole in the renal cortex [93, 94] and perivascular tissue [94], but could not determine whether this change in morphology affected afferent arteriolar constriction and renal function. Infiltration of inflammatory cells in the renal cortical matrix has been observed, suggesting an immunologic mechanism for SMC hypertrophy [93]. Interestingly, reduced pulsatility may induce (severe) peri-arteritis in the kidneys, an observation not made in control animals supported by pf-devices. Peri-arteritis has been linked to upregulation of the local RAS system [93]. Blood contact with the device’s artificial surface may activate inflammatory cells to induce inflammation [95, 96], although this should be largely prevented by formation of a pseudo-intima in the LVAD [78].
Latif et al. studied the GFR of LVAD-bridged and medication-bridged HTx recipients. Despite near identical patient characteristics and renal function at baseline, the medication-bridged population showed a higher GFR compared to the LVAD-bridged group following HTx [71]. This suggests that the LVAD may induce some permanent structural damage in the kidney.
Arguably, the late and gradual decline in renal function does not pose the largest clinical challenge for the duration of support at this point. For most patients, renal function can be maintained within normal ranges for the duration of support. However, with a growing number of DT patients, and the fact that LVADs are to be used for significantly longer periods of time, it is of the utmost importance to ascertain the causes of decreasing renal function. Because durability of MCS has improved, the cumulative effects of long-term support on non-cardiac organ function have become an important topic [19]. Introduction of pulsatility in rotary blood pumps [85] and reduction in shear stress may be necessary to further improve results [17].

Acute kidney injury after LVAD

Acute kidney injury (AKI) is one of the major perioperative adverse events following LVAD placement. Table 3 summarizes the incidence of AKI in cf-LVAD devices. Patel et al. [20] and Mao et al. [49] also reviewed AKI in the LVAD population. AKI is defined as a doubling of baseline sCr level or reduction of eGFR by 50 % following LVAD implantation [33]. Note that patient characteristics at baseline can greatly influence the occurrence of postimplant AKI. The incidence of AKI after cf-LVAD implantation varies considerably: between 4 and 38 % (see Table 3). It appears that studies from the early era of MCS report higher incidences of AKI compared to the most recent post-market evaluation studies. Reasons for this improvement are uncertain, but may include better patient selection and increased surgical experience.
Table 3
Incidence of acute kidney injury after implantation of continuous-flow LVAD
Enrollment period
Incidence AKI (%)
EPPY
LVAD type
Definition of AKI
Patients at baseline
References
Notes
9/1994–1/2007
24/63 (38)
NA
DeBakey
VAD (59)
HVAD (2)
Terumo
DuraHeart
LVAD (2)
AKI = RRT
sCr 1.4 (±0.6)
Sandner et al. [70]a
 
11/1998–7/2007
30/86 (35)
NA
DeBakey
VAD (75)
HVAD (6)
DuraHeart
LVAD (5)
AKI = RRT
sCr 1.3
Sandner et al. [35]
 
9/2002 –8/2005
4/14 (29)
NA
Jarvik 2000
AKI = RRT
sCr 1.5 (±0.5)
Feller et al. [103]a
 
11/2003–6/2009
15/107 (14)
NA
HMII
AKI = RRT
sCr 1.9 (±0.6)
Demirozu et al. [45]
b
3/2005–5/2006
18/133 (14)
0.31
HMII
ND
eGFR 75 (±37)
All NYHA IV
Miller et al. [104]
 
3/2005–5/2007
21/133 (16)
0.10
HMII
ND
sCr 1.6 (±0.6)
71 % NYHA IV
Slaughter et al. [105]
 
3/2005–4/2008
30/281 (11)
0.17
HMII
ND
eGFR 79 (±35)
All NYHA IV
Pagani et al. [106]
 
3/2006–12/2008
5/50 (10)
0.10
HVAD
ND
sCr 1.3 (±0.5)
Intermacs profile II (22 %) III (78 %) IV (8 %)
Strueber et al. [107]
 
3/2006–7/2011
28/100 (28)
NA
HMII and HVAD
RIFLE stage II and greater
sCr 1.4
Borgi et al. [98]
c
3/2006–12/2011
9/85 (11)
0.08
HMII
AKI = RRT
sCr 120 μmol/l
Intermacs profile I (25 %) II (75 %)
Lok et al. [64]
 
2/2007–6/2010
8/83 (10)
NA
HMII
AKI = RRT
sCr 1.6 (±0.7)
62 % NYHA IV
Hasin et al. [57]
d
5/2007–3/2009
30/281 (11)
0.06
HMII
ND
sCr 1.5 (±0.6)
63 % NYHA IV
Park et al. [111]
e
4/2008–8/2008
17/169 (10)
0.13
HMII
ND
sCr 1.3 (±0.5)
Intermacs profile I (24 %)
II (37 %)
III–VII (39 %)
Starling et al. [112]
 
4/2008–10/2010
129/1496 (9)
0.14
HMII
ND
sCr 1.4 (±0.8)
Intermacs profile I (17 %)
II (45 %)
III–VII (38 %)
John et al. [109]
 
8/2008–8/2010
12/140 (9)
0.16
HVAD
ND
sCr 1.3 (±0.4)
Intermacs profiles I (5 %) II (24 %) III (52 %) IV–VII (19 %)
Aaronson et al. [108]
 
8/2008–7/2012
32/332 (10)
0.13
HVAD
ND
eGFR 87 (±39)
96 % NYHA IV
Intermacs profile I (6 %) II (40 %) III (42 %)
Slaughter et al. [110]
f
2/2009–11/2012
10/254 (4)
0.04
HVAD
ND
sCr: ND
NYHA: ND
Strueber et al. [83]
 
Some studies repeat results of previous publications. Care was taken to disentangle those results and only represent the ‘new’ patients, not previously published
AKI acute kidney injury, BTT bridge to transplantation, DT destination therapy, eGFR estimated glomerular filtration rate (mL/min/1.73 m2), EPPY events per patient-year, HMII HeartMate II (Thoratec Inc., Pleasanton, CA), HVAD HeartWare ventricular assist device (HeartWare Inc., Framingham, MA), Intermacs Interagency Registry for Mechanically Assisted Circulatory Support, LVAD left ventricular assist device, NA not available, ND not defined, NYHA New York Heart Association, RRT renal replacement therapy, sCr serum creatinine (mg/dL)
aThese studies included both pulsatile and continuous-flow devices. However, outcomes of pf-LVADs were omitted
bThis single-center study only included patients supported for more than 30 days
c32 % of patients included in this study received LVAD as destination therapy
d68 % of patients included in this study received LVAD as destination therapy
eAll of the patients included in this study received LVAD as destination therapy
f140 patients included in this study were already previously reported by Aaronson et al. [108]
AKI is clearly a negative survival predictor [97]: patients experiencing AKI after LVAD implantation generally have a longer length of hospital stay and increased 30-day mortality [39, 98]. Genovese et al. predicted a threefold increased risk for 1-year mortality in case of AKI [99]. Several mechanisms of postoperative AKI, both functional and histological, have been proposed. Device routing may predispose hemodynamic instability, enhance thrombogenicity and spawn small emboli to the kidney, which have been observed as small renal infarctions in a lamb model [100]. In addition, cardiopulmonary bypass time [39, 101] and number of blood transfusions [77, 102] have been linked to AKI. Alternatively, hemolysis induced by high shear stress from the rotor, releasing free hemoglobin and iron, could play a role [77, 79]. These effects may act synergistically.

Renal replacement therapy

A variable number of LVAD recipients experiencing AKI after LVAD placement may require renal replacement therapy (RRT). In a recent Dutch study, 11 % of patients required post-surgical continuous venovenous hemofiltration [64], but this number may even reach 33 % [45, 97, 113]. Fortunately, the majority of patients recover from AKI and RRT can in many cases be discontinued after about 1 month [114].
Patients with preimplant RRT are only sporadically admitted for LVAD treatment; about 1.5 % of all new patients required dialysis before LVAD implantation [16]. This subpopulation is at increased mortality risk [16, 33], which makes clinicians more hesitant to initiate LVAD therapy. Nevertheless, successful results have been obtained and some of these patients could be weaned off RRT [45]. There is anecdotal evidence of patients whose renal function failed to improve either due to irreversible renal damage or early mortality [45, 115]. Incidentally, patients stay on RRT during LVAD support before combined heart and kidney transplantation [45].
Theoretically, some LVAD patients will experience gradual progression of CKD. If this gradual decline continues steadily and over a significant period of time, it will ultimately necessitate RRT. Considering the fact that widespread use of DT has only recently taken root, it is too early to evaluate if this subpopulation of RRT LVAD patients will occur.

Hemodialysis versus peritoneal dialysis

There are two options for RRT in the LVAD population, hemodialysis (HD) or peritoneal dialysis (PD). HD is currently the default option [6], although it has been suggested to give more consideration to PD because of its decreased chance of systemic infection [115, 116] and hemodynamic instability. Cross-contamination with the driveline site can be minimized by placing the PD catheter as far away as possible from the driveline exit site [116]. However, this option is not available for devices that need to be placed sub-diaphragmatically. Results with PD in LVAD patients are encouraging [116], but due to a lack of randomized controlled prospective trials, superiority over HD cannot yet be claimed [117].

Management challenges

AKI necessitating RRT poses considerable challenges [117]. Hemodynamic instability and the fact that LVAD patients show reduced to no pulse makes continuous pulse and BP monitoring difficult. Normal arm-cuff BP measurements are less reliable. Instead, blood flow and BP can be estimated using Doppler probe devices [117]. This was shown to be successful in over 90 % of attempts, roughly twofold the success rate of arm-cuff measurements [118].
Theoretically, there are several dangers of HD for LVAD patients. Currently, cf-LVADs are volume-sensitive and can malfunction due to intravascular fluid flux inherent to HD [114]. Reduced blood volume as well as increased pump speed can create a so-called suction event in which the left atrium and ventricle collapse [114, 117]. Changes in pump speed due to volume sensitivity during HD can also induce thrombosis (reduced speed) or hemolysis (increased speed) [114, 117]. Although challenging and not without risks, HD can be given to LVAD patients safely under specialized supervision. A recent report showed that only 5 % of HD sessions were interrupted or terminated, with no serious adverse effects noted [114].

Future outlook

In the USA, the annual number of LVAD placements (>2000 [16]) has surpassed the number of heart transplantations since 2009 [119]. In 2011, 37 % of HTx recipients were bridged to transplantation with an LVAD [120], and this percentage is steadily increasing [121]. Currently, DT accounts for over 40 % of new implants [16], and this fraction is also expected to grow [84]. In Europe, LVADs are still predominantly used for BTT, although the tide may shift toward DT in the (near) future, mimicking the trend abroad. In Japan, which faces an extremely low availability of donor hearts, DT has already been proposed as the new gold standard for treatment of end-stage HF [122].
Several developments can accelerate the growing acceptance of implantable MCS devices for DT, including device miniaturization, development of less invasive surgical techniques and reduction of adverse event burden [123]. At present, the percutaneous driveline cable considerably limits patients’ quality of life and poses risk for infection. Transcutaneous energy transfer systems [124] and, alternatively, free-range resonant electrical delivery [125] will render driveline cables obsolete. Successful implementation of transcutaneous energy transfer systems will mark a decisive turning point for the use of LVAD technology in mainstream therapy of advanced HF [126]. However, documented reduction in adverse event burden is urgently required before a paradigm shift of MCS as true alternative to HTx can occur [123].
At present, there is not enough evidence to support the durability and reliability of LVAD therapy for lengths of time comparable to HTx. There are no reliable data concerning end-organ function after prolonged LVAD support (e.g., >5 years) [33], although it is expected that 10-year survival can soon be achieved with current devices [37]. Currently, only around 100 LVAD patients have survived longer than 5–7.5 years [17, 48]. Long-term studies (>1 year) are needed to assess effects on end-organ function with continuous-flow devices, which may have important implications for use as DT [69, 127]. Gradually declining renal function may have important clinical consequences if LVADs are expected to offer long-term chronic support as DT. The transient nature of renal recovery also has relevance to the BTT population. Haglund et al. [128] recently demonstrated that LVAD patients with pre-HTx GFR < 45 mL/min/m2 show reduced graft survival after HTx.
There are many research avenues to be investigated. The extent to which declining GFR could be attributed to sCr measurements biased for muscle mass can be investigated using a muscle-mass independent serum marker such as Cystatin C. In addition, possible reduction of in vivo erythrocyte survival should be investigated to ascertain the possible role of subclinical hemolysis and consequent nephrotoxicity. Closer attention can be paid to the long-term effects of continuous-flow support, particularly in relation to renal (micro) vasculature. Better understanding of the relationship between the LVAD and the kidney may aid development of more durable devices and help improve patient selection.

Conclusion

In conclusion, LVAD therapy has become an established treatment option for end-stage HF patients. Although difficult to predict, following LVAD implantation CRS type II is often relieved quickly in this population. Interestingly, early recovery appears to be transient and is followed by a gradual decline in GFR starting 1–2 months following implantation. Larger increases in GFR are followed by a proportionally larger decline later on, although GFR generally remains above preimplant levels for duration of follow-up. LVAD patient outcomes continue to improve, and adverse events including AKI are on the decline. Emerging technological advances such as transcutaneous energy transfer are expected to greatly improve quality of life in the near future and may allow these devices to start rivalling HTx. However, considering the growing acceptance of DT, it is of the utmost importance to be informed on long-term cumulative effects of the LVAD on the kidneys. Additional experience, gained with both research and passage of time, is required to further unravel the intricate relationship between LVADs and the kidney.

Acknowledgments

We thank J.R. Martina and N. Hulstein for their practical advice and informative comments.

Conflict of interest

None.

Ethical standard

This article does not contain any studies with human participants or animals performed by any of the authors.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Literatur
1.
Zurück zum Zitat Seferovic PM, Stoerk S, Filippatos G et al (2013) Organization of heart failure management in European Society of Cardiology member countries: survey of the Heart Failure Association of the European Society of Cardiology in collaboration with the Heart Failure National Societies/Working Groups. Eur J Heart Fail 15(9):947–959PubMed Seferovic PM, Stoerk S, Filippatos G et al (2013) Organization of heart failure management in European Society of Cardiology member countries: survey of the Heart Failure Association of the European Society of Cardiology in collaboration with the Heart Failure National Societies/Working Groups. Eur J Heart Fail 15(9):947–959PubMed
2.
Zurück zum Zitat Roger VL, Go AS, Lloyd-Jones DM et al (2012) Heart disease and stroke statistics-2012 update: a report from the American Heart Association. Circulation 125(1):e2–e220PubMedCentralPubMed Roger VL, Go AS, Lloyd-Jones DM et al (2012) Heart disease and stroke statistics-2012 update: a report from the American Heart Association. Circulation 125(1):e2–e220PubMedCentralPubMed
4.
Zurück zum Zitat Ammirati E, Oliva F, Cannata A et al (2014) Current indications for heart transplantation and left ventricular assist device: a practical point of view. Eur J Intern Med 25(5):422–429PubMed Ammirati E, Oliva F, Cannata A et al (2014) Current indications for heart transplantation and left ventricular assist device: a practical point of view. Eur J Intern Med 25(5):422–429PubMed
5.
Zurück zum Zitat Jessup M, Brozena S (2003) Heart failure. N Engl J Med 348(20):2007–2018PubMed Jessup M, Brozena S (2003) Heart failure. N Engl J Med 348(20):2007–2018PubMed
6.
Zurück zum Zitat Allen JG, Weiss ES, Schaffer JM et al (2010) Quality of life and functional status in patients surviving 12 months after left ventricular assist device implantation. J Heart Lung Transplant 29(3):278–285PubMedCentralPubMed Allen JG, Weiss ES, Schaffer JM et al (2010) Quality of life and functional status in patients surviving 12 months after left ventricular assist device implantation. J Heart Lung Transplant 29(3):278–285PubMedCentralPubMed
7.
Zurück zum Zitat Rodriguez LE, Suarez EE, Loebe M, Bruckner BA (2013) Ventricular assist devices (VAD) therapy: new technology, new hope? Methodist Debakey Cardiovasc J 9(1):32–37PubMedCentralPubMed Rodriguez LE, Suarez EE, Loebe M, Bruckner BA (2013) Ventricular assist devices (VAD) therapy: new technology, new hope? Methodist Debakey Cardiovasc J 9(1):32–37PubMedCentralPubMed
8.
Zurück zum Zitat Rigatelli G, Santini F, Faggian G (2012) Past and present of cardiocirculatory assist devices: a comprehensive critical review. J Geriatr Cardiol 9(4):389–400PubMedCentralPubMed Rigatelli G, Santini F, Faggian G (2012) Past and present of cardiocirculatory assist devices: a comprehensive critical review. J Geriatr Cardiol 9(4):389–400PubMedCentralPubMed
9.
Zurück zum Zitat Eurotransplant International Foundation. Eurotransplant Annual Report 2013. Rahmel A (ed). Leiden Eurotransplant International Foundation. Eurotransplant Annual Report 2013. Rahmel A (ed). Leiden
10.
Zurück zum Zitat Singh TP, Almond CS, Taylor DO, Graham DA (2012) Decline in heart transplant wait list mortality in the United States following broader regional sharing of donor hearts. Circ Heart Fail 5(2):249–258PubMed Singh TP, Almond CS, Taylor DO, Graham DA (2012) Decline in heart transplant wait list mortality in the United States following broader regional sharing of donor hearts. Circ Heart Fail 5(2):249–258PubMed
11.
Zurück zum Zitat Bruce CR, Brody B, Majumder MA (2013) Ethical dilemmas surrounding the use of ventricular assist devices in supporting patients with end-stage organ dysfunction. Methodist Debakey Cardiovasc J 9(1):11–14PubMedCentralPubMed Bruce CR, Brody B, Majumder MA (2013) Ethical dilemmas surrounding the use of ventricular assist devices in supporting patients with end-stage organ dysfunction. Methodist Debakey Cardiovasc J 9(1):11–14PubMedCentralPubMed
12.
Zurück zum Zitat Nascimbene A, Hernandez R, George JK et al (2014) Association between cell-derived microparticles and adverse events in patients with nonpulsatile left ventricular assist devices. J Heart Lung Transplant 33(5):470–477PubMedCentralPubMed Nascimbene A, Hernandez R, George JK et al (2014) Association between cell-derived microparticles and adverse events in patients with nonpulsatile left ventricular assist devices. J Heart Lung Transplant 33(5):470–477PubMedCentralPubMed
13.
Zurück zum Zitat Rose E, Gelijns A (2001) Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med 345(20):1435–1443PubMed Rose E, Gelijns A (2001) Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med 345(20):1435–1443PubMed
14.
Zurück zum Zitat Hrobowski T, Lanfear DE (2013) Ventricular assist devices: is destination therapy a viable alternative in the non-transplant candidate? Curr Heart Fail Rep 10(1):101–107PubMedCentralPubMed Hrobowski T, Lanfear DE (2013) Ventricular assist devices: is destination therapy a viable alternative in the non-transplant candidate? Curr Heart Fail Rep 10(1):101–107PubMedCentralPubMed
15.
Zurück zum Zitat Pruijsten RV, de Jonge N, Kirkels JH et al (2008) Left ventricular assist device: a functional comparison with heart transplantation. Neth Heart J 16(2):41–46PubMedCentralPubMed Pruijsten RV, de Jonge N, Kirkels JH et al (2008) Left ventricular assist device: a functional comparison with heart transplantation. Neth Heart J 16(2):41–46PubMedCentralPubMed
16.
Zurück zum Zitat Kirklin JK, Naftel DC, Pagani FD et al (2014) Sixth intermacs annual report: a 10,000 patient database. J Heart Lung Transplant 33(6):555–564PubMed Kirklin JK, Naftel DC, Pagani FD et al (2014) Sixth intermacs annual report: a 10,000 patient database. J Heart Lung Transplant 33(6):555–564PubMed
17.
Zurück zum Zitat Dembitsky WP, Adamson RM (2014) Chapter 1 opportunities and challenges for LVAD therapy now and in the future. In: Kyo S (ed) Ventricular assist devices in advanced-stage heart failure. Springer, Japan Dembitsky WP, Adamson RM (2014) Chapter 1 opportunities and challenges for LVAD therapy now and in the future. In: Kyo S (ed) Ventricular assist devices in advanced-stage heart failure. Springer, Japan
18.
Zurück zum Zitat Slaughter MS, Bostic R, Tong K, Russo M, Rogers JG (2011) Temporal changes in hospital costs for left ventricular assist device implantation. J Card Surg 26(5):535–541PubMed Slaughter MS, Bostic R, Tong K, Russo M, Rogers JG (2011) Temporal changes in hospital costs for left ventricular assist device implantation. J Card Surg 26(5):535–541PubMed
19.
Zurück zum Zitat Brisco MA, Kimmel SE, Coca SG et al (2014) Prevalence and prognostic importance of changes in renal function after mechanical circulatory support. Circ Heart Fail 7(1):68–75PubMedCentralPubMed Brisco MA, Kimmel SE, Coca SG et al (2014) Prevalence and prognostic importance of changes in renal function after mechanical circulatory support. Circ Heart Fail 7(1):68–75PubMedCentralPubMed
20.
Zurück zum Zitat Patel AM, Adeseun GA, Ahmed I, Mitter N, Rame JE, Rudnick MR (2013) Renal failure in patients with left ventricular assist devices. Clin J Am Soc Nephrol 8(3):484–496PubMed Patel AM, Adeseun GA, Ahmed I, Mitter N, Rame JE, Rudnick MR (2013) Renal failure in patients with left ventricular assist devices. Clin J Am Soc Nephrol 8(3):484–496PubMed
21.
Zurück zum Zitat Patel UD, Hernandez AF, Liang L et al (2008) Quality of care and outcomes among patients with heart failure and chronic kidney disease: a get with the guidelines—Heart Failure Program study. Am Heart J 156(4):674–681PubMedCentralPubMed Patel UD, Hernandez AF, Liang L et al (2008) Quality of care and outcomes among patients with heart failure and chronic kidney disease: a get with the guidelines—Heart Failure Program study. Am Heart J 156(4):674–681PubMedCentralPubMed
22.
Zurück zum Zitat Braam B, Joles JA, Danishwar AH, Gaillard CA (2014) Cardiorenal syndrome-current understanding and future perspectives. Nat Rev Nephrol 10(1):48–55PubMed Braam B, Joles JA, Danishwar AH, Gaillard CA (2014) Cardiorenal syndrome-current understanding and future perspectives. Nat Rev Nephrol 10(1):48–55PubMed
24.
Zurück zum Zitat McCullough PA, Kellum JA, Haase M et al (2013) Pathophysiology of the cardiorenal syndromes: executive summary from the eleventh consensus conference of the Acute Dialysis Quality Initiative (ADQI. Contrib Nephrol 182:82–98PubMed McCullough PA, Kellum JA, Haase M et al (2013) Pathophysiology of the cardiorenal syndromes: executive summary from the eleventh consensus conference of the Acute Dialysis Quality Initiative (ADQI. Contrib Nephrol 182:82–98PubMed
25.
Zurück zum Zitat Cruz DN, Schmidt-Ott KM, Vescovo G et al (2013) Pathophysiology of cardiorenal syndrome type 2 in stable chronic heart failure: workgroup statements from the eleventh consensus conference of the Acute Dialysis Quality Initiative (ADQI. Contrib Nephrol 182:117–136PubMed Cruz DN, Schmidt-Ott KM, Vescovo G et al (2013) Pathophysiology of cardiorenal syndrome type 2 in stable chronic heart failure: workgroup statements from the eleventh consensus conference of the Acute Dialysis Quality Initiative (ADQI. Contrib Nephrol 182:117–136PubMed
26.
Zurück zum Zitat Damman K, van Deursen VM, Navis G, Voors AA, van Veldhuisen DJ, Hillege HL (2009) Increased central venous pressure is associated with impaired renal function and mortality in a broad spectrum of patients with cardiovascular disease. J Am Coll Cardiol 53(7):582–588PubMed Damman K, van Deursen VM, Navis G, Voors AA, van Veldhuisen DJ, Hillege HL (2009) Increased central venous pressure is associated with impaired renal function and mortality in a broad spectrum of patients with cardiovascular disease. J Am Coll Cardiol 53(7):582–588PubMed
27.
Zurück zum Zitat Mullens W, Abrahams Z, Francis GS et al (2009) Importance of venous congestion for worsening of renal function in advanced decompensated heart failure. J Am Coll Cardiol 53(7):589–596PubMedCentralPubMed Mullens W, Abrahams Z, Francis GS et al (2009) Importance of venous congestion for worsening of renal function in advanced decompensated heart failure. J Am Coll Cardiol 53(7):589–596PubMedCentralPubMed
28.
Zurück zum Zitat Bongartz LG, Cramer MJ, Doevendans PA, Joles JA, Braam B (2005) The severe cardiorenal syndrome: “Guyton revisited”. Eur Heart J 26(1):11–17PubMed Bongartz LG, Cramer MJ, Doevendans PA, Joles JA, Braam B (2005) The severe cardiorenal syndrome: “Guyton revisited”. Eur Heart J 26(1):11–17PubMed
29.
Zurück zum Zitat Rafiq K, Noma T, Fujisawa Y et al (2012) Renal sympathetic denervation suppresses de novo podocyte injury and albuminuria in rats with aortic regurgitation. Circulation 125(11):1402–1413PubMedCentralPubMed Rafiq K, Noma T, Fujisawa Y et al (2012) Renal sympathetic denervation suppresses de novo podocyte injury and albuminuria in rats with aortic regurgitation. Circulation 125(11):1402–1413PubMedCentralPubMed
30.
Zurück zum Zitat Parida S, Badhe AS (2013) Cardiac surgery-associated acute kidney injury. J Anesth 27(3):433–446PubMed Parida S, Badhe AS (2013) Cardiac surgery-associated acute kidney injury. J Anesth 27(3):433–446PubMed
31.
Zurück zum Zitat McCullough PA, Shaw AD, Haase M et al (2013) Diagnosis of acute kidney injury using functional and injury biomarkers: workgroup statements from the tenth acute dialysis quality initiative consensus conference. Contrib Nephrol 182:13–29PubMed McCullough PA, Shaw AD, Haase M et al (2013) Diagnosis of acute kidney injury using functional and injury biomarkers: workgroup statements from the tenth acute dialysis quality initiative consensus conference. Contrib Nephrol 182:13–29PubMed
32.
Zurück zum Zitat Damman K, Voors AA, Navis G, van Veldhuisen DJ, Hillege HL (2012) Current and novel renal biomarkers in heart failure. Heart Fail Rev 17(2):241–250PubMedCentralPubMed Damman K, Voors AA, Navis G, van Veldhuisen DJ, Hillege HL (2012) Current and novel renal biomarkers in heart failure. Heart Fail Rev 17(2):241–250PubMedCentralPubMed
33.
Zurück zum Zitat Kirklin JK, Naftel DC, Kormos RL et al (2013) Quantifying the effect of cardiorenal syndrome on mortality after left ventricular assist device implant. J Heart Lung Transplant 32(12):1205–1213PubMed Kirklin JK, Naftel DC, Kormos RL et al (2013) Quantifying the effect of cardiorenal syndrome on mortality after left ventricular assist device implant. J Heart Lung Transplant 32(12):1205–1213PubMed
34.
Zurück zum Zitat Ma L, Fujino Y, Matsumiya G, Sawa Y, Mashimo T (2008) Renal function with left ventricular assist devices: the poorer the preoperative renal function, the longer the recovery. Med Sci Monit 14(12):CR621–CR627PubMed Ma L, Fujino Y, Matsumiya G, Sawa Y, Mashimo T (2008) Renal function with left ventricular assist devices: the poorer the preoperative renal function, the longer the recovery. Med Sci Monit 14(12):CR621–CR627PubMed
35.
Zurück zum Zitat Sandner SE, Zimpfer D, Zrunek P et al (2009) Renal function and outcome after continuous flow left ventricular assist device implantation. Ann Thorac Surg 87(4):1072–1078PubMed Sandner SE, Zimpfer D, Zrunek P et al (2009) Renal function and outcome after continuous flow left ventricular assist device implantation. Ann Thorac Surg 87(4):1072–1078PubMed
36.
Zurück zum Zitat Hillege HL, Nitsch D, Pfeffer MA et al (2006) Renal function as a predictor of outcome in a broad spectrum of patients with heart failure. Circulation 113(5):671–678PubMed Hillege HL, Nitsch D, Pfeffer MA et al (2006) Renal function as a predictor of outcome in a broad spectrum of patients with heart failure. Circulation 113(5):671–678PubMed
37.
Zurück zum Zitat Kyo S (2014) Ventricular assist devices in advanced-stage heart failure. Springer, Japan Kyo S (2014) Ventricular assist devices in advanced-stage heart failure. Springer, Japan
38.
Zurück zum Zitat Gilotra NA, Russell SD (2013) Patient selection for mechanical circulatory support. Heart Fail Rev 18(1):27–34PubMed Gilotra NA, Russell SD (2013) Patient selection for mechanical circulatory support. Heart Fail Rev 18(1):27–34PubMed
39.
Zurück zum Zitat Alba AC, Rao V, Ivanov J, Ross HJ, Delgado DH (2009) Predictors of acute renal dysfunction after ventricular assist device placement. J Card Fail 15(10):874–881PubMed Alba AC, Rao V, Ivanov J, Ross HJ, Delgado DH (2009) Predictors of acute renal dysfunction after ventricular assist device placement. J Card Fail 15(10):874–881PubMed
40.
Zurück zum Zitat Imamura T, Kinugawa K, Shiga T et al (2013) Preoperative levels of bilirubin or creatinine adjusted by age can predict their reversibility after implantation of left ventricular assist device. Circ J 77(1):96–104PubMed Imamura T, Kinugawa K, Shiga T et al (2013) Preoperative levels of bilirubin or creatinine adjusted by age can predict their reversibility after implantation of left ventricular assist device. Circ J 77(1):96–104PubMed
41.
Zurück zum Zitat Imamura T, Kinugawa K, Shiga T et al (2012) Novel risk scoring system with preoperative objective parameters gives a good prediction of 1-year mortality in patients with a left ventricular assist device. Circ J 76(8):1895–1903PubMed Imamura T, Kinugawa K, Shiga T et al (2012) Novel risk scoring system with preoperative objective parameters gives a good prediction of 1-year mortality in patients with a left ventricular assist device. Circ J 76(8):1895–1903PubMed
42.
Zurück zum Zitat Schaffer JM, Allen JG, Weiss ES et al (2009) Evaluation of risk indices in continuous-flow left ventricular assist device patients. Ann Thorac Surg 88(6):1889–1896PubMed Schaffer JM, Allen JG, Weiss ES et al (2009) Evaluation of risk indices in continuous-flow left ventricular assist device patients. Ann Thorac Surg 88(6):1889–1896PubMed
43.
Zurück zum Zitat Rosenbaum AN, Duval S, Adatya S, Khan MBS, John R, Eckman PM (2013) The effect of continuous flow left ventricular assist device (CF-LVAD) implantation on serum uric acid levels. Int J Cardiol 168(4):4291–4293PubMed Rosenbaum AN, Duval S, Adatya S, Khan MBS, John R, Eckman PM (2013) The effect of continuous flow left ventricular assist device (CF-LVAD) implantation on serum uric acid levels. Int J Cardiol 168(4):4291–4293PubMed
44.
Zurück zum Zitat Iwashima Y, Yanase M, Horio T et al (2012) Serial changes in renal function as a prognostic indicator in advanced heart failure patients with left ventricular assist system. Ann Thorac Surg 93(3):816–823PubMed Iwashima Y, Yanase M, Horio T et al (2012) Serial changes in renal function as a prognostic indicator in advanced heart failure patients with left ventricular assist system. Ann Thorac Surg 93(3):816–823PubMed
45.
Zurück zum Zitat Demirozu ZT, Etheridge WB, Radovancevic R, Frazier OH (2011) Results of HeartMate II left ventricular assist device implantation on renal function in patients requiring postimplant renal replacement therapy. J Heart Lung Transplant 30(2):182–187PubMed Demirozu ZT, Etheridge WB, Radovancevic R, Frazier OH (2011) Results of HeartMate II left ventricular assist device implantation on renal function in patients requiring postimplant renal replacement therapy. J Heart Lung Transplant 30(2):182–187PubMed
46.
Zurück zum Zitat Khot UN, Mishra M, Yamani MH et al (2003) Severe renal dysfunction complicating cardiogenic shock is not a contraindication to mechanical support as a bridge to cardiac transplantation. J Am Coll Cardiol 41(3):381–385PubMed Khot UN, Mishra M, Yamani MH et al (2003) Severe renal dysfunction complicating cardiogenic shock is not a contraindication to mechanical support as a bridge to cardiac transplantation. J Am Coll Cardiol 41(3):381–385PubMed
47.
Zurück zum Zitat Ruzza A, Esmailian F, Vespignani R et al (2013) Renal dysfunction does not contraindicate ventricular assist device as destination therapy or as bridge to single heart or combined heart and kidney transplantation. J Heart Lung Transplant 32(4):S231 Ruzza A, Esmailian F, Vespignani R et al (2013) Renal dysfunction does not contraindicate ventricular assist device as destination therapy or as bridge to single heart or combined heart and kidney transplantation. J Heart Lung Transplant 32(4):S231
48.
Zurück zum Zitat Westaby S, Siegenthaler M, Beyersdorf F et al (2010) Destination therapy with a rotary blood pump and novel power delivery. Eur J Cardiothorac Surg 37(2):350–356PubMed Westaby S, Siegenthaler M, Beyersdorf F et al (2010) Destination therapy with a rotary blood pump and novel power delivery. Eur J Cardiothorac Surg 37(2):350–356PubMed
49.
Zurück zum Zitat Mao H, Katz N, Kim JC, Day S, Ronco C (2014) Implantable left ventricular assist devices and the kidney. Blood Purif 37(1):57–66PubMed Mao H, Katz N, Kim JC, Day S, Ronco C (2014) Implantable left ventricular assist devices and the kidney. Blood Purif 37(1):57–66PubMed
50.
Zurück zum Zitat Elhenawy AM, Algarni KD, Rodger M et al (2011) Mechanical circulatory support as a bridge to transplant candidacy. J Card Surg 26(5):542–547PubMed Elhenawy AM, Algarni KD, Rodger M et al (2011) Mechanical circulatory support as a bridge to transplant candidacy. J Card Surg 26(5):542–547PubMed
51.
Zurück zum Zitat Lund LH, Matthews J, Aaronson K (2010) Patient selection for left ventricular assist devices. Eur J Heart Fail 12(5):434–443PubMed Lund LH, Matthews J, Aaronson K (2010) Patient selection for left ventricular assist devices. Eur J Heart Fail 12(5):434–443PubMed
52.
Zurück zum Zitat Butler J, Geisberg C, Howser R et al (2006) Relationship between renal function and left ventricular assist device use. Ann Thorac Surg 81(5):1745–1751PubMed Butler J, Geisberg C, Howser R et al (2006) Relationship between renal function and left ventricular assist device use. Ann Thorac Surg 81(5):1745–1751PubMed
53.
Zurück zum Zitat Brisco MA, Coca SG, Chen J et al (2013) Blood urea nitrogen/creatinine ratio identifies a high-risk but potentially reversible form of renal dysfunction in patients with decompensated heart failure. Circ Heart Fail 6(2):233–239PubMedCentralPubMed Brisco MA, Coca SG, Chen J et al (2013) Blood urea nitrogen/creatinine ratio identifies a high-risk but potentially reversible form of renal dysfunction in patients with decompensated heart failure. Circ Heart Fail 6(2):233–239PubMedCentralPubMed
54.
Zurück zum Zitat Slaughter MS, Pagani FD, Rogers JG et al (2010) Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. J Heart Lung Transplant 29(4 Suppl):S1–S39PubMed Slaughter MS, Pagani FD, Rogers JG et al (2010) Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. J Heart Lung Transplant 29(4 Suppl):S1–S39PubMed
55.
Zurück zum Zitat Kainuma S, Sakaguchi T, Saito S et al (2012) Implantation of a Jarvik 2000 left ventricular assist device as a bridge to eligibility for refractory heart failure with renal dysfunction. J Artif Organs 15(1):83–86PubMed Kainuma S, Sakaguchi T, Saito S et al (2012) Implantation of a Jarvik 2000 left ventricular assist device as a bridge to eligibility for refractory heart failure with renal dysfunction. J Artif Organs 15(1):83–86PubMed
56.
Zurück zum Zitat Singh M, Shullo M, Kormos RL et al (2011) Impact of renal function before mechanical circulatory support on posttransplant renal outcomes. Ann Thorac Surg 91(5):1348–1354PubMed Singh M, Shullo M, Kormos RL et al (2011) Impact of renal function before mechanical circulatory support on posttransplant renal outcomes. Ann Thorac Surg 91(5):1348–1354PubMed
57.
Zurück zum Zitat Hasin T, Topilsky Y, Schirger JA et al (2012) Changes in renal function after implantation of continuous-flow left ventricular assist devices. J Am Coll Cardiol 59(1):26–36PubMed Hasin T, Topilsky Y, Schirger JA et al (2012) Changes in renal function after implantation of continuous-flow left ventricular assist devices. J Am Coll Cardiol 59(1):26–36PubMed
58.
Zurück zum Zitat Iwashima Y, Yanase M, Horio T et al (2012) Effect of pulsatile left ventricular assist system implantation on Doppler measurements of renal hemodynamics in patients with advanced heart failure. Artif Organs 36(4):353–358PubMed Iwashima Y, Yanase M, Horio T et al (2012) Effect of pulsatile left ventricular assist system implantation on Doppler measurements of renal hemodynamics in patients with advanced heart failure. Artif Organs 36(4):353–358PubMed
59.
Zurück zum Zitat James KB, McCarthy PM, Jaalouk S et al (1996) Plasma volume and its regulatory factors in congestive heart failure after implantation of long-term left ventricular assist devices. Circulation 93(8):1515–1519PubMed James KB, McCarthy PM, Jaalouk S et al (1996) Plasma volume and its regulatory factors in congestive heart failure after implantation of long-term left ventricular assist devices. Circulation 93(8):1515–1519PubMed
60.
Zurück zum Zitat Welp H, Rukosujew A, Tjan TD, Hoffmeier A, Kösek V, Scheld HH, Drees G (2010) Effect of pulsatile and non-pulsatile left ventricular assist devices on the renin-angiotensin system in patients with end-stage heart failure. Thorac Cardiovasc Surg 58(2 Suppl):S185–S188PubMed Welp H, Rukosujew A, Tjan TD, Hoffmeier A, Kösek V, Scheld HH, Drees G (2010) Effect of pulsatile and non-pulsatile left ventricular assist devices on the renin-angiotensin system in patients with end-stage heart failure. Thorac Cardiovasc Surg 58(2 Suppl):S185–S188PubMed
61.
Zurück zum Zitat Yambe T, Nitta S, Katahira Y, Sonobe T, Tanaka M, Miura M, Satoh N, Mohri H, Yoshizawa M, Takeda H (1990) Effect of left ventricular assistance on sympathetic tone. Int J Artif Organs 13:681–686PubMed Yambe T, Nitta S, Katahira Y, Sonobe T, Tanaka M, Miura M, Satoh N, Mohri H, Yoshizawa M, Takeda H (1990) Effect of left ventricular assistance on sympathetic tone. Int J Artif Organs 13:681–686PubMed
62.
Zurück zum Zitat James KB, McCarthy PM, Thomas JD, Vargo R, Hobbs RE, Sapp S, Bravo E (1995) Effect of the implantable left ventricular assist device on neuroendocrine activation in heart failure. Circulation 92:191–195 James KB, McCarthy PM, Thomas JD, Vargo R, Hobbs RE, Sapp S, Bravo E (1995) Effect of the implantable left ventricular assist device on neuroendocrine activation in heart failure. Circulation 92:191–195
63.
Zurück zum Zitat Russell SD, Rogers JG, Milano CA et al (2009) Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device. Circulation 120(23):2352–2357PubMed Russell SD, Rogers JG, Milano CA et al (2009) Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device. Circulation 120(23):2352–2357PubMed
64.
Zurück zum Zitat Lok SI, Martina JR, Hesselink T et al (2013) Single-centre experience of 85 patients with a continuous-flow left ventricular assist device: clinical practice and outcome after extended support. Eur J Cardiothorac Surg 44(3):e233–e238PubMed Lok SI, Martina JR, Hesselink T et al (2013) Single-centre experience of 85 patients with a continuous-flow left ventricular assist device: clinical practice and outcome after extended support. Eur J Cardiothorac Surg 44(3):e233–e238PubMed
65.
Zurück zum Zitat Deo SV, Sharma V, Altarabsheh SE et al (2014) Hepatic and renal function with successful long-term support on a continuous flow left ventricular assist device. Heart Lung Circ 23(3):229–233PubMed Deo SV, Sharma V, Altarabsheh SE et al (2014) Hepatic and renal function with successful long-term support on a continuous flow left ventricular assist device. Heart Lung Circ 23(3):229–233PubMed
66.
Zurück zum Zitat Jacobs S, Droogne W, Waelbers V et al (2014) Evolution of renal function after partial and full mechanical support for chronic heart failure. Int J Artif Organs 37(5):364–370PubMed Jacobs S, Droogne W, Waelbers V et al (2014) Evolution of renal function after partial and full mechanical support for chronic heart failure. Int J Artif Organs 37(5):364–370PubMed
67.
Zurück zum Zitat Feitell S, Patel J, Pirlamarla P et al (2013) Type 2 cardiorenal syndrome in the left ventricular assist device (LVAD) population. J Heart Lung Transplant 32(4):S227 Feitell S, Patel J, Pirlamarla P et al (2013) Type 2 cardiorenal syndrome in the left ventricular assist device (LVAD) population. J Heart Lung Transplant 32(4):S227
68.
Zurück zum Zitat Radovancevic B, Vrtovec B, de Kort E, Radovancevic R, Gregoric ID, Frazier OH (2007) End-organ function in patients on long-term circulatory support with continuous- or pulsatile-flow assist devices. J Heart Lung Transplant 26(8):815–818PubMed Radovancevic B, Vrtovec B, de Kort E, Radovancevic R, Gregoric ID, Frazier OH (2007) End-organ function in patients on long-term circulatory support with continuous- or pulsatile-flow assist devices. J Heart Lung Transplant 26(8):815–818PubMed
69.
Zurück zum Zitat Kamdar F, Boyle A, Liao K, Colvin-adams M, Joyce L, John R (2009) Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients. J Heart Lung Transplant 28(4):352–359PubMed Kamdar F, Boyle A, Liao K, Colvin-adams M, Joyce L, John R (2009) Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients. J Heart Lung Transplant 28(4):352–359PubMed
70.
Zurück zum Zitat Sandner SE, Zimpfer D, Zrunek P et al (2008) Renal function after implantation of continuous versus pulsatile flow left ventricular assist devices. J Heart Lung Transplant 27(5):469–473PubMed Sandner SE, Zimpfer D, Zrunek P et al (2008) Renal function after implantation of continuous versus pulsatile flow left ventricular assist devices. J Heart Lung Transplant 27(5):469–473PubMed
71.
Zurück zum Zitat Latif F, Pak S-W, Uriel N et al (2011) Effect of LVAD on the prognostic value of baseline GFR for long term renal function in patients undergoing heart transplant (HTX. J Heart Lung Transplant 30(4):S78–S79 Latif F, Pak S-W, Uriel N et al (2011) Effect of LVAD on the prognostic value of baseline GFR for long term renal function in patients undergoing heart transplant (HTX. J Heart Lung Transplant 30(4):S78–S79
72.
Zurück zum Zitat Libório AB, Uchia RS, Aragao AP et al (2012) Importance of anemia in the chronic cardiorenal syndrome: effects on renal function after heart transplantation. Med Sci Monit 18(10):CR611–CR616PubMedCentralPubMed Libório AB, Uchia RS, Aragao AP et al (2012) Importance of anemia in the chronic cardiorenal syndrome: effects on renal function after heart transplantation. Med Sci Monit 18(10):CR611–CR616PubMedCentralPubMed
73.
Zurück zum Zitat Cohen E, Nardi Y, Krause I, Goldberg E, Milo G, Garty M, Krause I (2014) A longitudinal assessment of the natural rate of decline in renal function with age. J Nephrol 27(6):635–641 Cohen E, Nardi Y, Krause I, Goldberg E, Milo G, Garty M, Krause I (2014) A longitudinal assessment of the natural rate of decline in renal function with age. J Nephrol 27(6):635–641
74.
Zurück zum Zitat Eriksen BO, Ingebretsen OC (2006) The progression of chronic kidney disease: a 10-year population-based study of the effects of gender and age. Kidney Int 69(2):375–382PubMed Eriksen BO, Ingebretsen OC (2006) The progression of chronic kidney disease: a 10-year population-based study of the effects of gender and age. Kidney Int 69(2):375–382PubMed
75.
Zurück zum Zitat Altemtam N, Russell J, El Nahas M (2012) A study of the natural history of diabetic kidney disease (DKD). Nephrol Dial Transplant 27(5):1847–1854PubMed Altemtam N, Russell J, El Nahas M (2012) A study of the natural history of diabetic kidney disease (DKD). Nephrol Dial Transplant 27(5):1847–1854PubMed
76.
Zurück zum Zitat Macedo E, Mehta R (2010) Prerenal azotemia in congestive heart failure. Contrib Nephrol 164:79–87PubMed Macedo E, Mehta R (2010) Prerenal azotemia in congestive heart failure. Contrib Nephrol 164:79–87PubMed
77.
Zurück zum Zitat Moreno JA, Martín-Cleary C, Gutiérrez E et al (2012) AKI associated with macroscopic glomerular hematuria: clinical and pathophysiologic consequences. Clin J Am Soc Nephrol 7(1):175–184PubMed Moreno JA, Martín-Cleary C, Gutiérrez E et al (2012) AKI associated with macroscopic glomerular hematuria: clinical and pathophysiologic consequences. Clin J Am Soc Nephrol 7(1):175–184PubMed
78.
Zurück zum Zitat Meyer AL, Malehsa D, Budde U, Bara C, Haverich A, Strueber M (2014) Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device. JACC Heart Fail 2(2):141–145PubMed Meyer AL, Malehsa D, Budde U, Bara C, Haverich A, Strueber M (2014) Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device. JACC Heart Fail 2(2):141–145PubMed
79.
Zurück zum Zitat Burke MA, Givertz MM (2014) Assessment and management of heart failure after left ventricular assist device implantation. Circulation 129(10):1161–1166PubMed Burke MA, Givertz MM (2014) Assessment and management of heart failure after left ventricular assist device implantation. Circulation 129(10):1161–1166PubMed
80.
Zurück zum Zitat Heyman SN, Brezis M (1995) Acute renal failure in glomerular bleeding: a puzzling phenomenon. Nephrol Dial Transplant 10(5):591–593PubMed Heyman SN, Brezis M (1995) Acute renal failure in glomerular bleeding: a puzzling phenomenon. Nephrol Dial Transplant 10(5):591–593PubMed
81.
Zurück zum Zitat Kormos RL, Teuteberg JJ, Pagani FD et al (2010) Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes. J Thorac Cardiovasc Surg 139(5):1316–1324PubMed Kormos RL, Teuteberg JJ, Pagani FD et al (2010) Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes. J Thorac Cardiovasc Surg 139(5):1316–1324PubMed
82.
Zurück zum Zitat Puhlman M (2012) Continuous-flow left ventricular assist device and the right ventricle. AACN Adv Crit Care 23(1):86–90PubMed Puhlman M (2012) Continuous-flow left ventricular assist device and the right ventricle. AACN Adv Crit Care 23(1):86–90PubMed
83.
Zurück zum Zitat Strueber M, Larbalestier R, Jansz P et al (2014) Results of the post-market registry to evaluate the heartware left ventricular assist system (ReVOLVE. J Heart Lung Transplant 33(5):486–491PubMed Strueber M, Larbalestier R, Jansz P et al (2014) Results of the post-market registry to evaluate the heartware left ventricular assist system (ReVOLVE. J Heart Lung Transplant 33(5):486–491PubMed
84.
Zurück zum Zitat Patel CB, Cowger JA, Zuckermann A (2014) A contemporary review of mechanical circulatory support. J Heart Lung Transplant 33(7):667–674PubMed Patel CB, Cowger JA, Zuckermann A (2014) A contemporary review of mechanical circulatory support. J Heart Lung Transplant 33(7):667–674PubMed
85.
Zurück zum Zitat Pirbodaghi T, Asgari S, Cotter C, Bourque K (2014) Physiologic and hematologic concerns of rotary blood pumps: what needs to be improved? Heart Fail Rev 19(2):259–266PubMed Pirbodaghi T, Asgari S, Cotter C, Bourque K (2014) Physiologic and hematologic concerns of rotary blood pumps: what needs to be improved? Heart Fail Rev 19(2):259–266PubMed
86.
Zurück zum Zitat Nishimura T, Tatsumi E, Takaichi S (1997) Morphologic changes of the aortic wall due to reduced systemic pulse pressure in prolonged non pulsatile left heart bypass. ASAIO J 43(5):M691–M695PubMed Nishimura T, Tatsumi E, Takaichi S (1997) Morphologic changes of the aortic wall due to reduced systemic pulse pressure in prolonged non pulsatile left heart bypass. ASAIO J 43(5):M691–M695PubMed
87.
Zurück zum Zitat Westaby S, Bertoni GB, Clelland C, Nishinaka T, Frazier OH (2007) Circulatory support with attenuated pulse pressure alters human aortic wall morphology. J Thorac Cardiovasc Surg 133(2):575–576PubMed Westaby S, Bertoni GB, Clelland C, Nishinaka T, Frazier OH (2007) Circulatory support with attenuated pulse pressure alters human aortic wall morphology. J Thorac Cardiovasc Surg 133(2):575–576PubMed
88.
Zurück zum Zitat Segura AM, Gregoric I, Radovancevic R, Demirozu ZT, Buja LM, Frazier OH (2013) Morphologic changes in the aortic wall media after support with a continuous-flow left ventricular assist device. J Heart Lung Transplant 32(11):1096–1100PubMed Segura AM, Gregoric I, Radovancevic R, Demirozu ZT, Buja LM, Frazier OH (2013) Morphologic changes in the aortic wall media after support with a continuous-flow left ventricular assist device. J Heart Lung Transplant 32(11):1096–1100PubMed
89.
Zurück zum Zitat Amir O, Radovancevic B, Delgado RM et al (2006) Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support. J Heart Lung Transplant 25(4):391–394PubMed Amir O, Radovancevic B, Delgado RM et al (2006) Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support. J Heart Lung Transplant 25(4):391–394PubMed
90.
Zurück zum Zitat Nishinaka T, Tatsumi E, Nishimura T et al (2001) Change in vasoconstrictive function during prolonged nonpulsatile left heart bypass. Artif Organs 25(5):371–375PubMed Nishinaka T, Tatsumi E, Nishimura T et al (2001) Change in vasoconstrictive function during prolonged nonpulsatile left heart bypass. Artif Organs 25(5):371–375PubMed
91.
Zurück zum Zitat Bartoli CR, Giridharan GA, Litwak KN et al (2010) Hemodynamic responses to continuous versus pulsatile mechanical unloading of the failing left ventricle. ASAIO J 56(5):410–416PubMed Bartoli CR, Giridharan GA, Litwak KN et al (2010) Hemodynamic responses to continuous versus pulsatile mechanical unloading of the failing left ventricle. ASAIO J 56(5):410–416PubMed
92.
Zurück zum Zitat Kihara S, Litwak KN, Nichols L et al (2003) Smooth muscle cell hypertrophy of renal cortex ventricular assist. Ann Thorac Surg 75(1):178–183PubMed Kihara S, Litwak KN, Nichols L et al (2003) Smooth muscle cell hypertrophy of renal cortex ventricular assist. Ann Thorac Surg 75(1):178–183PubMed
93.
Zurück zum Zitat Ootaki C, Yamashita M, Ootaki Y et al (2008) Reduced pulsatility induces periarteritis in kidney: role of the local renin-angiotensin system. J Thorac Cardiovasc Surg 136(1):150–158PubMedCentralPubMed Ootaki C, Yamashita M, Ootaki Y et al (2008) Reduced pulsatility induces periarteritis in kidney: role of the local renin-angiotensin system. J Thorac Cardiovasc Surg 136(1):150–158PubMedCentralPubMed
94.
Zurück zum Zitat Ohnishi H, Itoh T, Nishinaka T et al (2002) Morphological changes of the arterial systems in the kidney under prolonged continuous flow left heart bypass. Artif Organs 26(11):974–979PubMed Ohnishi H, Itoh T, Nishinaka T et al (2002) Morphological changes of the arterial systems in the kidney under prolonged continuous flow left heart bypass. Artif Organs 26(11):974–979PubMed
95.
Zurück zum Zitat Grosman-Rimon L (2014) Chronic inflammation in heart failure patients with mechanical circulatory support. J Heart Lung Transplant 33(4):S76–S77 Grosman-Rimon L (2014) Chronic inflammation in heart failure patients with mechanical circulatory support. J Heart Lung Transplant 33(4):S76–S77
96.
Zurück zum Zitat Kurien S, Hughes KA (2012) Anticoagulation and bleeding in patients with ventricular assist devices: walking the tightrope. AACN Adv Crit Care 23(1):91–98PubMed Kurien S, Hughes KA (2012) Anticoagulation and bleeding in patients with ventricular assist devices: walking the tightrope. AACN Adv Crit Care 23(1):91–98PubMed
97.
Zurück zum Zitat Kaltenmaier B, Pommer W, Kaufmann F, Hennig E, Molzahn M, Hetzer R (2000) Outcome of patients with ventricular assist devices and acute renal failure requiring renal replacement therapy. ASAIO J 46(3):330–333PubMed Kaltenmaier B, Pommer W, Kaufmann F, Hennig E, Molzahn M, Hetzer R (2000) Outcome of patients with ventricular assist devices and acute renal failure requiring renal replacement therapy. ASAIO J 46(3):330–333PubMed
98.
Zurück zum Zitat Borgi J, Tsiouris A, Hodari A, Cogan CM, Paone G, Morgan JA (2013) Significance of postoperative acute renal failure after continuous-flow left ventricular assist device implantation. Ann Thorac Surg 95(1):163–169PubMed Borgi J, Tsiouris A, Hodari A, Cogan CM, Paone G, Morgan JA (2013) Significance of postoperative acute renal failure after continuous-flow left ventricular assist device implantation. Ann Thorac Surg 95(1):163–169PubMed
99.
Zurück zum Zitat Genovese EA, Dew MA, Teuteberg JJ et al (2010) Early adverse events as predictors of 1-year mortality during mechanical circulatory support. J Heart Lung Transplant 29(9):981–988PubMedCentralPubMed Genovese EA, Dew MA, Teuteberg JJ et al (2010) Early adverse events as predictors of 1-year mortality during mechanical circulatory support. J Heart Lung Transplant 29(9):981–988PubMedCentralPubMed
100.
Zurück zum Zitat Cooper TK, Zhong Q, Nabity M, Rosenberg G, Weiss WJ (2012) Use of urinary biomarkers of renal ischemia in a lamb preclinical left ventricular assist device model. Artif Organs 36(9):820–824PubMed Cooper TK, Zhong Q, Nabity M, Rosenberg G, Weiss WJ (2012) Use of urinary biomarkers of renal ischemia in a lamb preclinical left ventricular assist device model. Artif Organs 36(9):820–824PubMed
101.
Zurück zum Zitat Morgan JA, Brewer RJ, Nemeh HW et al (2010) Impact of acute renal failure on survival after HM II LVAD implantation. J Heart Lung Transplant 29(2):S178 Morgan JA, Brewer RJ, Nemeh HW et al (2010) Impact of acute renal failure on survival after HM II LVAD implantation. J Heart Lung Transplant 29(2):S178
102.
Zurück zum Zitat Karkouti K, Wijeysundera DN, Yau TM et al (2009) Acute kidney injury after cardiac surgery: focus on modifiable risk factors. Circulation 119(4):495–502PubMed Karkouti K, Wijeysundera DN, Yau TM et al (2009) Acute kidney injury after cardiac surgery: focus on modifiable risk factors. Circulation 119(4):495–502PubMed
103.
Zurück zum Zitat Feller ED, Sorensen EN, Haddad M et al (2007) Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients. Ann Thorac Surg 83(3):1082–1088PubMed Feller ED, Sorensen EN, Haddad M et al (2007) Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients. Ann Thorac Surg 83(3):1082–1088PubMed
104.
Zurück zum Zitat Miller L, Pagani F, Russell S et al (2007) Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 2007:885–896 Miller L, Pagani F, Russell S et al (2007) Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 2007:885–896
105.
Zurück zum Zitat Slaughter MS, Rogers JG, Milano CA et al (2009) Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 361(23):2241–2251PubMed Slaughter MS, Rogers JG, Milano CA et al (2009) Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 361(23):2241–2251PubMed
106.
Zurück zum Zitat Pagani FD, Miller LW, Russell SD et al (2009) Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 54(4):312–321PubMed Pagani FD, Miller LW, Russell SD et al (2009) Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 54(4):312–321PubMed
107.
Zurück zum Zitat Strueber M, O’Driscoll G, Jansz P, Khaghani A, Levy WC, Wieselthaler GM (2011) Multicenter evaluation of an intrapericardial left ventricular assist system. J Am Coll Cardiol 57(12):1375–1382PubMed Strueber M, O’Driscoll G, Jansz P, Khaghani A, Levy WC, Wieselthaler GM (2011) Multicenter evaluation of an intrapericardial left ventricular assist system. J Am Coll Cardiol 57(12):1375–1382PubMed
108.
Zurück zum Zitat Aaronson KD, Slaughter MS, Miller LW et al (2012) Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation. Circulation 125(25):3191–3200PubMed Aaronson KD, Slaughter MS, Miller LW et al (2012) Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation. Circulation 125(25):3191–3200PubMed
109.
Zurück zum Zitat John R, Naka Y, Smedira NG et al (2011) Continuous flow left ventricular assist device outcomes in commercial use compared with the prior clinical trial. Ann Thorac Surg 92(4):1406–1413 (discussion 1413)PubMed John R, Naka Y, Smedira NG et al (2011) Continuous flow left ventricular assist device outcomes in commercial use compared with the prior clinical trial. Ann Thorac Surg 92(4):1406–1413 (discussion 1413)PubMed
110.
Zurück zum Zitat Slaughter MS, Pagani FD, McGee EC et al (2013) HeartWare ventricular assist system for bridge to transplant: combined results of the bridge to transplant and continued access protocol trial. J Heart Lung Transplant 32(7):675–683PubMed Slaughter MS, Pagani FD, McGee EC et al (2013) HeartWare ventricular assist system for bridge to transplant: combined results of the bridge to transplant and continued access protocol trial. J Heart Lung Transplant 32(7):675–683PubMed
111.
Zurück zum Zitat Park SJ, Milano CA, Tatooles AJ et al (2012) Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy. Circ Heart Fail 5(2):241–248PubMed Park SJ, Milano CA, Tatooles AJ et al (2012) Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy. Circ Heart Fail 5(2):241–248PubMed
112.
Zurück zum Zitat Starling RC, Naka Y, Boyle AJ et al (2011) Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: a prospective study using the INTERMACS (Interagency Registry for Mechanically Assisted Circul. J Am Coll Cardiol 57(19):1890–1898PubMed Starling RC, Naka Y, Boyle AJ et al (2011) Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: a prospective study using the INTERMACS (Interagency Registry for Mechanically Assisted Circul. J Am Coll Cardiol 57(19):1890–1898PubMed
113.
Zurück zum Zitat Topkara VK, Dang NC, Barili F et al (2006) Predictors and outcomes of continuous veno-venous hemodialysis use after implantation of a left ventricular assist device. J Heart Lung Transplant 25(4):404–408PubMed Topkara VK, Dang NC, Barili F et al (2006) Predictors and outcomes of continuous veno-venous hemodialysis use after implantation of a left ventricular assist device. J Heart Lung Transplant 25(4):404–408PubMed
114.
Zurück zum Zitat Quader MA, Kumar D, Shah KB, Fatani YI, Katlaps G, Kasirajan V (2014) Safety analysis of intermittent hemodialysis in patients with continuous flow left ventricular assist devices. Hemodial Int 18(1):205–209PubMed Quader MA, Kumar D, Shah KB, Fatani YI, Katlaps G, Kasirajan V (2014) Safety analysis of intermittent hemodialysis in patients with continuous flow left ventricular assist devices. Hemodial Int 18(1):205–209PubMed
115.
Zurück zum Zitat Thomas BA, Logar CM, Anderson AE (2012) Renal replacement therapy in congestive heart failure requiring left ventricular assist device augmentation. Perit Dial Int 32(4):386–392PubMedCentralPubMed Thomas BA, Logar CM, Anderson AE (2012) Renal replacement therapy in congestive heart failure requiring left ventricular assist device augmentation. Perit Dial Int 32(4):386–392PubMedCentralPubMed
116.
Zurück zum Zitat Guglielmi AA, Guglielmi KE, Bhat G, Siemeck R, Tatooles AJ (2014) Peritoneal dialysis after left ventricular assist device placement. ASAIO J 60(1):127–128PubMed Guglielmi AA, Guglielmi KE, Bhat G, Siemeck R, Tatooles AJ (2014) Peritoneal dialysis after left ventricular assist device placement. ASAIO J 60(1):127–128PubMed
117.
Zurück zum Zitat Patel AM, Eduardo Rame J, Rudnick MR (2014) How does the nephrologist manage an LVAD patient on chronic maintenance dialysis? Semin Dial 27(3):284–288PubMed Patel AM, Eduardo Rame J, Rudnick MR (2014) How does the nephrologist manage an LVAD patient on chronic maintenance dialysis? Semin Dial 27(3):284–288PubMed
118.
Zurück zum Zitat Bennett MK, Roberts CA, Dordunoo D, Shah A, Russell SD (2010) Ideal methodology to assess systemic blood pressure in patients with continuous-flow left ventricular assist devices. J Heart Lung Transplant 29(5):593–594PubMed Bennett MK, Roberts CA, Dordunoo D, Shah A, Russell SD (2010) Ideal methodology to assess systemic blood pressure in patients with continuous-flow left ventricular assist devices. J Heart Lung Transplant 29(5):593–594PubMed
119.
Zurück zum Zitat Mulloy DP, Bhamidipati CM, Stone ML, Ailawadi G, Kron IL, Kern JA (2013) Orthotopic heart transplant versus left ventricular assist device: a national comparison of cost and survival. J Thorac Cardiovasc Surg 145(2):566–573 (discussion 573–574)PubMedCentralPubMed Mulloy DP, Bhamidipati CM, Stone ML, Ailawadi G, Kron IL, Kern JA (2013) Orthotopic heart transplant versus left ventricular assist device: a national comparison of cost and survival. J Thorac Cardiovasc Surg 145(2):566–573 (discussion 573–574)PubMedCentralPubMed
120.
Zurück zum Zitat Lund LH, Edwards LB, Kucheryavaya AY et al (2013) The Registry of the International Society for Heart and Lung Transplantation: thirtieth Official Adult Heart Transplant Report–2013; focus theme: age. J Heart Lung Transplant 32(10):951–964PubMed Lund LH, Edwards LB, Kucheryavaya AY et al (2013) The Registry of the International Society for Heart and Lung Transplantation: thirtieth Official Adult Heart Transplant Report–2013; focus theme: age. J Heart Lung Transplant 32(10):951–964PubMed
121.
Zurück zum Zitat Mancini DM, Schulze PC (2014) Heart transplant allocation: in desperate need of revision. J Am Coll Cardiol 63(12):1179–1181PubMed Mancini DM, Schulze PC (2014) Heart transplant allocation: in desperate need of revision. J Am Coll Cardiol 63(12):1179–1181PubMed
122.
Zurück zum Zitat Yamakawa M, Kyo S, Yamakawa S, Ono M, Kinugawa K, Nishimura T (2013) Destination therapy: the new gold standard treatment for heart failure patients with left ventricular assist devices. Gen Thorac Cardiovasc Surg 61(3):111–117PubMed Yamakawa M, Kyo S, Yamakawa S, Ono M, Kinugawa K, Nishimura T (2013) Destination therapy: the new gold standard treatment for heart failure patients with left ventricular assist devices. Gen Thorac Cardiovasc Surg 61(3):111–117PubMed
123.
Zurück zum Zitat Kirklin JK (2014) Terminal heart failure: who should be transplanted and who should have mechanical circulatory support? Curr Opin Organ Transplant 19(5):486–493PubMed Kirklin JK (2014) Terminal heart failure: who should be transplanted and who should have mechanical circulatory support? Curr Opin Organ Transplant 19(5):486–493PubMed
124.
Zurück zum Zitat Slaughter MS, Myers TJ (2010) Transcutaneous energy transmission for mechanical circulatory support systems: history, current status, and future prospects. J Card Surg 25(4):484–489PubMed Slaughter MS, Myers TJ (2010) Transcutaneous energy transmission for mechanical circulatory support systems: history, current status, and future prospects. J Card Surg 25(4):484–489PubMed
125.
Zurück zum Zitat Waters BH, Smith JR, Bonde P (2014) Innovative free-range resonant electrical energy delivery system (FREE-D system) for a ventricular assist device using wireless power. ASAIO J 60(1):31–37PubMed Waters BH, Smith JR, Bonde P (2014) Innovative free-range resonant electrical energy delivery system (FREE-D system) for a ventricular assist device using wireless power. ASAIO J 60(1):31–37PubMed
126.
Zurück zum Zitat Wever-Pinzon O, Stehlik J (2012) Ventricular assist devices: pharmacological aspects of a mechanical therapy. Pharmacol Ther 134(2):189–199PubMedCentralPubMed Wever-Pinzon O, Stehlik J (2012) Ventricular assist devices: pharmacological aspects of a mechanical therapy. Pharmacol Ther 134(2):189–199PubMedCentralPubMed
127.
Zurück zum Zitat Caccamo M, Eckman P, John R (2011) Current state of ventricular assist devices. Curr Heart Fail Rep 8(2):91–98PubMed Caccamo M, Eckman P, John R (2011) Current state of ventricular assist devices. Curr Heart Fail Rep 8(2):91–98PubMed
128.
Zurück zum Zitat Haglund NA, Feurer ID, Dwyer JP et al (2014) Does renal dysfunction and method of bridging support influence heart transplant graft survival? Ann Thorac Surg 98(3):835–841PubMed Haglund NA, Feurer ID, Dwyer JP et al (2014) Does renal dysfunction and method of bridging support influence heart transplant graft survival? Ann Thorac Surg 98(3):835–841PubMed
Metadaten
Titel
Left ventricular assist devices: a kidney’s perspective
verfasst von
T. R. Tromp
N. de Jonge
J. A. Joles
Publikationsdatum
01.07.2015
Verlag
Springer US
Erschienen in
Heart Failure Reviews / Ausgabe 4/2015
Print ISSN: 1382-4147
Elektronische ISSN: 1573-7322
DOI
https://doi.org/10.1007/s10741-015-9481-z

Weitere Artikel der Ausgabe 4/2015

Heart Failure Reviews 4/2015 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.