We sought to compare the reliability and prognostic implications of left ventricular (LV) ejection fraction (EF) measurements obtained in routine clinical practice. We retrospectively selected from our clinical database a group of 422 patients with known or suspected ischemic heart disease, studied by two-dimensional echocardiography, gated single-photon emission computed tomography (SPECT) and left ventriculography (LVG) for clinical purposes. In each diagnostic procedure LVEF was measured as done routinely. The LVEF values obtained by the three methods were similar and closely related. The correlation coefficient r was equal to 0.83 between echocardiographic and LVG, to 0.75 between gated SPECT and LVG and to 0.81 between echocardiographic and SPECT. During follow-up (median 41 months), 31 patients died. The values of LVEF obtained by echocardiography, gated-SPECT and LVG were all powerful predictors of all-cause mortality: χ2 = 12.3 for echocardiography, 14.4 for gated SPECT and 14.5 for LVG. However, including LVEF values into a model based on patient age, sex, history of angina, evidence of previous infarction and number of stenotic coronary arteries, the ability to predict patient survival significantly increased only including LVEF values measured by gated SPECT (χ2 = 40.6, = 0.039). Thus, in a large cohort of unselected patients with known or suspected ischemic heart disease, the values of LVEF routinely measured by echocardiography, gated SPECT and LVG were closely correlated, and provided a powerful prognostic information, that was incremental to clinical variables for gated SPECT.
Literatur
1.
Zurück zum Zitat Cohn PF, Gorlin R, Cohn LH, Collins JJ Jr (1974) Left ventricular ejection fraction as a prognostic guide in surgical treatment of coronary and valvular heart disease. Am J Cardiol 34:136–141PubMedCrossRef Cohn PF, Gorlin R, Cohn LH, Collins JJ Jr (1974) Left ventricular ejection fraction as a prognostic guide in surgical treatment of coronary and valvular heart disease. Am J Cardiol 34:136–141PubMedCrossRef
2.
Zurück zum Zitat Battler A, Slutsky R, Karliner J, Froelicher V, Ashburn W, Ross J Jr (1980) Left ventricular ejection fraction and first third ejection fraction early after acute myocardial infarction: value for predicting mortality and morbidity. Am J Cardiol 45:197–202PubMedCrossRef Battler A, Slutsky R, Karliner J, Froelicher V, Ashburn W, Ross J Jr (1980) Left ventricular ejection fraction and first third ejection fraction early after acute myocardial infarction: value for predicting mortality and morbidity. Am J Cardiol 45:197–202PubMedCrossRef
3.
Zurück zum Zitat Curtis JP, Sokol SI, Wang Y, Rathore SS, Ko DT, Jadbabaie F et al (2003) The association of left ventricular ejection fraction, mortality, and cause of death in stable outpatients with heart failure. J Am Coll Cardiol 42:736–742PubMedCrossRef Curtis JP, Sokol SI, Wang Y, Rathore SS, Ko DT, Jadbabaie F et al (2003) The association of left ventricular ejection fraction, mortality, and cause of death in stable outpatients with heart failure. J Am Coll Cardiol 42:736–742PubMedCrossRef
4.
Zurück zum Zitat Bosch X, Theroux P (2005) Left ventricular ejection fraction to predict early mortality in patients with non-ST-segment elevation acute coronary syndromes. Am Heart J 150:215–220PubMedCrossRef Bosch X, Theroux P (2005) Left ventricular ejection fraction to predict early mortality in patients with non-ST-segment elevation acute coronary syndromes. Am Heart J 150:215–220PubMedCrossRef
5.
Zurück zum Zitat Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS et al (2002) Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 346:877–883PubMedCrossRef Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS et al (2002) Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 346:877–883PubMedCrossRef
6.
Zurück zum Zitat Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E et al (2002) MIRACLE Study Group. Multicenter InSync randomized clinical evaluation. Cardiac resynchronization in chronic heart failure. N Engl J Med 346:1845–1853PubMedCrossRef Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E et al (2002) MIRACLE Study Group. Multicenter InSync randomized clinical evaluation. Cardiac resynchronization in chronic heart failure. N Engl J Med 346:1845–1853PubMedCrossRef
7.
Zurück zum Zitat Henning H, Schelbert H, Crawford MH, Karliner JS, Ashburn W, O’Rourke RA (1975) Left ventricular performance assessed by radionuclide angiocardiography and echocardiography in patients with previous myocardial infarction. Circulation 52:1069–1075PubMed Henning H, Schelbert H, Crawford MH, Karliner JS, Ashburn W, O’Rourke RA (1975) Left ventricular performance assessed by radionuclide angiocardiography and echocardiography in patients with previous myocardial infarction. Circulation 52:1069–1075PubMed
8.
Zurück zum Zitat Teichholz LE, Kreulen T, Herman MV, Gorlin R (1976) Problems in echocardiographic volume determinations: echocardiographic–angiographic correlations in the presence of absence of asynergy. Am J Cardiol 37:7–11PubMedCrossRef Teichholz LE, Kreulen T, Herman MV, Gorlin R (1976) Problems in echocardiographic volume determinations: echocardiographic–angiographic correlations in the presence of absence of asynergy. Am J Cardiol 37:7–11PubMedCrossRef
9.
Zurück zum Zitat Folland ED, Parisi AF, Moynihan PF, Jones DR, Feldman CL, Tow DE (1979) Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation 60:760–766PubMed Folland ED, Parisi AF, Moynihan PF, Jones DR, Feldman CL, Tow DE (1979) Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques. Circulation 60:760–766PubMed
10.
Zurück zum Zitat Quinones MA, Waggoner AD, Reduto LA, Nelson JG, Young JB, Winters WL Jr et al (1981) A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography. Circulation 64:744–753PubMed Quinones MA, Waggoner AD, Reduto LA, Nelson JG, Young JB, Winters WL Jr et al (1981) A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography. Circulation 64:744–753PubMed
11.
Zurück zum Zitat Rich S, Sheikh A, Gallastegui J, Kondos GT, Mason T, Lam W (1982) Determination of left ventricular ejection fraction by visual estimation during real-time two-dimensional echocardiography. Am Heart J 104:603–606PubMedCrossRef Rich S, Sheikh A, Gallastegui J, Kondos GT, Mason T, Lam W (1982) Determination of left ventricular ejection fraction by visual estimation during real-time two-dimensional echocardiography. Am Heart J 104:603–606PubMedCrossRef
12.
Zurück zum Zitat Baran AO, Rogal GJ, Nanda NC (1983) Ejection fraction determination without planimetry by two-dimensional echocardiography: a new method. J Am Coll Cardiol 1:1471–1478PubMedCrossRef Baran AO, Rogal GJ, Nanda NC (1983) Ejection fraction determination without planimetry by two-dimensional echocardiography: a new method. J Am Coll Cardiol 1:1471–1478PubMedCrossRef
13.
Zurück zum Zitat Erbel R, Schweizer P, Krebs W, Meyer J, Effert S (1984) Sensitivity and specificity of two-dimensional echocardiography in detection of impaired left ventricular function. Eur Heart J 5:477–489PubMed Erbel R, Schweizer P, Krebs W, Meyer J, Effert S (1984) Sensitivity and specificity of two-dimensional echocardiography in detection of impaired left ventricular function. Eur Heart J 5:477–489PubMed
14.
Zurück zum Zitat Amico AF, Lichtenberg GS, Reisner SA, Stone CK, Schwartz RG, Meltzer RS (1989) Superiority of visual versus computerized echocardiographic estimation of radionuclide left ventricular ejection fraction. Am Heart J 118:1259–1265PubMedCrossRef Amico AF, Lichtenberg GS, Reisner SA, Stone CK, Schwartz RG, Meltzer RS (1989) Superiority of visual versus computerized echocardiographic estimation of radionuclide left ventricular ejection fraction. Am Heart J 118:1259–1265PubMedCrossRef
15.
Zurück zum Zitat Yvorchuk KJ, Davies RA, Chan KL (1994) Measurement of left ventricular ejection fraction by acoustic quantification and comparison with radionuclide angiography. Am J Cardiol 74:1052–1056PubMedCrossRef Yvorchuk KJ, Davies RA, Chan KL (1994) Measurement of left ventricular ejection fraction by acoustic quantification and comparison with radionuclide angiography. Am J Cardiol 74:1052–1056PubMedCrossRef
16.
Zurück zum Zitat Senior R, Sridhara BS, Basu S, Henley M, Handler CE, Raftery EB et al (1994) Comparison of radionuclide ventriculography and 2D echocardiography for the measurement of left ventricular ejection fraction following acute myocardial infarction. Eur Heart J 15:1235–1239PubMed Senior R, Sridhara BS, Basu S, Henley M, Handler CE, Raftery EB et al (1994) Comparison of radionuclide ventriculography and 2D echocardiography for the measurement of left ventricular ejection fraction following acute myocardial infarction. Eur Heart J 15:1235–1239PubMed
17.
Zurück zum Zitat Lindower PD, Rath L, Preslar J, Burns TL, Rezai K, Vandenberg BF (1994) Quantification of left ventricular function with an automated border detection system and comparison with radionuclide ventriculography. Am J Cardiol 73:195–199PubMedCrossRef Lindower PD, Rath L, Preslar J, Burns TL, Rezai K, Vandenberg BF (1994) Quantification of left ventricular function with an automated border detection system and comparison with radionuclide ventriculography. Am J Cardiol 73:195–199PubMedCrossRef
18.
Zurück zum Zitat Gopal AS, Shen Z, Sapin PM, Keller AM, Schnellbaecher MJ, Leibowitz DW et al (1995) Assessment of cardiac function by three-dimensional echocardiography compared with conventional noninvasive methods. Circulation 92:842–853PubMed Gopal AS, Shen Z, Sapin PM, Keller AM, Schnellbaecher MJ, Leibowitz DW et al (1995) Assessment of cardiac function by three-dimensional echocardiography compared with conventional noninvasive methods. Circulation 92:842–853PubMed
19.
Zurück zum Zitat Naik MM, Diamond GA, Pai T, Soffer A, Siegel RJ (1995) Correspondence of left ventricular ejection fraction determinations from two-dimensional echocardiography, radionuclide angiography and contrast cineangiography. J Am Coll Cardiol 25:937–942PubMedCrossRef Naik MM, Diamond GA, Pai T, Soffer A, Siegel RJ (1995) Correspondence of left ventricular ejection fraction determinations from two-dimensional echocardiography, radionuclide angiography and contrast cineangiography. J Am Coll Cardiol 25:937–942PubMedCrossRef
20.
Zurück zum Zitat Nosir YF, Fioretti PM, Vletter WB, Boersma E, Salustri A, Postma JT et al (1996) Accurate measurement of left ventricular ejection fraction by three-dimensional echocardiography. A comparison with radionuclide angiography. Circulation 94:460–466PubMed Nosir YF, Fioretti PM, Vletter WB, Boersma E, Salustri A, Postma JT et al (1996) Accurate measurement of left ventricular ejection fraction by three-dimensional echocardiography. A comparison with radionuclide angiography. Circulation 94:460–466PubMed
21.
Zurück zum Zitat Chandra S, Bahl VK, Reddy SC, Bhargava B, Malhotra A, Wasir HS (1997) Comparison of echocardiographic acoustic quantification system and radionuclide ventriculography for estimating left ventricular ejection fraction: validation in patients without regional wall motion abnormalities. Am Heart J 133:359–363PubMedCrossRef Chandra S, Bahl VK, Reddy SC, Bhargava B, Malhotra A, Wasir HS (1997) Comparison of echocardiographic acoustic quantification system and radionuclide ventriculography for estimating left ventricular ejection fraction: validation in patients without regional wall motion abnormalities. Am Heart J 133:359–363PubMedCrossRef
22.
Zurück zum Zitat Jensen-Urstad K, Bouvier F, Hojer J, Ruiz H, Hulting J, Samad B et al (1998) Comparison of different echocardiographic methods with radionuclide imaging for measuring left ventricular ejection fraction during acute myocardial infarction treated by thrombolytic therapy. Am J Cardiol 81:538–544PubMedCrossRef Jensen-Urstad K, Bouvier F, Hojer J, Ruiz H, Hulting J, Samad B et al (1998) Comparison of different echocardiographic methods with radionuclide imaging for measuring left ventricular ejection fraction during acute myocardial infarction treated by thrombolytic therapy. Am J Cardiol 81:538–544PubMedCrossRef
23.
Zurück zum Zitat Hibberd MG, Chuang ML, Beaudin RA, Riley MF, Mooney MG, Fearnside JT et al (2000) Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction. Am Heart J 140:469–475PubMedCrossRef Hibberd MG, Chuang ML, Beaudin RA, Riley MF, Mooney MG, Fearnside JT et al (2000) Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction. Am Heart J 140:469–475PubMedCrossRef
24.
Zurück zum Zitat Bellenger NG, Burgess MI, Ray SG, Lahiri A, Coats AJ, Cleland JG et al (2000) Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J 21:1387–1396PubMedCrossRef Bellenger NG, Burgess MI, Ray SG, Lahiri A, Coats AJ, Cleland JG et al (2000) Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J 21:1387–1396PubMedCrossRef
25.
Zurück zum Zitat Malm S, Frigstad S, Sagberg E, Larsson H, Skjaerpe T (2004) Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging. J Am Coll Cardiol 44:1030–1035PubMedCrossRef Malm S, Frigstad S, Sagberg E, Larsson H, Skjaerpe T (2004) Accurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging. J Am Coll Cardiol 44:1030–1035PubMedCrossRef
26.
Zurück zum Zitat Galasko GI, Basu S, Lahiri A, Senior R (2004) Is echocardiography a valid tool to screen for left ventricular systolic dysfunction in chronic survivors of acute myocardial infarction? A comparison with radionuclide ventriculography. Heart 90:1422–1426PubMedCrossRef Galasko GI, Basu S, Lahiri A, Senior R (2004) Is echocardiography a valid tool to screen for left ventricular systolic dysfunction in chronic survivors of acute myocardial infarction? A comparison with radionuclide ventriculography. Heart 90:1422–1426PubMedCrossRef
27.
Zurück zum Zitat Hoffmann R, von Bardeleben S, ten Cate F, Borges AC, Kasprzak J, Firschke C et al (2005) Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiography. Eur Heart J 26:607–616PubMedCrossRef Hoffmann R, von Bardeleben S, ten Cate F, Borges AC, Kasprzak J, Firschke C et al (2005) Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiography. Eur Heart J 26:607–616PubMedCrossRef
28.
Zurück zum Zitat Vaduganathan P, He ZX, Vick GW III, Mahmarian JJ, Verani MS (1999) Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99 m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging. J Nucl Cardiol 6:3–10PubMedCrossRef Vaduganathan P, He ZX, Vick GW III, Mahmarian JJ, Verani MS (1999) Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99 m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging. J Nucl Cardiol 6:3–10PubMedCrossRef
29.
Zurück zum Zitat Tadamura E, Kudoh T, Motooka M, Inubushi M, Okada T, Kubo S et al (1999) Use of technetium–99 m sestamibi ECG-gated single-photon emission tomography for the evaluation of left ventricular function following coronary artery bypass graft: comparison with three-dimensional magnetic resonance imaging. Eur J Nucl Med 26:705–712PubMedCrossRef Tadamura E, Kudoh T, Motooka M, Inubushi M, Okada T, Kubo S et al (1999) Use of technetium–99 m sestamibi ECG-gated single-photon emission tomography for the evaluation of left ventricular function following coronary artery bypass graft: comparison with three-dimensional magnetic resonance imaging. Eur J Nucl Med 26:705–712PubMedCrossRef
30.
Zurück zum Zitat Yoshioka J, Hasegawa S, Yamaguchi H, Tokita N, Paul AK, Xiuli M et al (1999) Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT. J Nucl Med 40:1693–1698PubMed Yoshioka J, Hasegawa S, Yamaguchi H, Tokita N, Paul AK, Xiuli M et al (1999) Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT. J Nucl Med 40:1693–1698PubMed
31.
Zurück zum Zitat Bax JJ, Lamb H, Dibbets P, Pelikan H, Boersma E, Viergever EP et al (2000) Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy. Am J Cardiol 86:1299–1305PubMedCrossRef Bax JJ, Lamb H, Dibbets P, Pelikan H, Boersma E, Viergever EP et al (2000) Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy. Am J Cardiol 86:1299–1305PubMedCrossRef
32.
Zurück zum Zitat Faber TL, Vansant JP, Pettigrew RI, Galt JR, Blais M, Chatzimavroudis G et al (2001) Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods. J Nucl Cardiol 8:645–651PubMedCrossRef Faber TL, Vansant JP, Pettigrew RI, Galt JR, Blais M, Chatzimavroudis G et al (2001) Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods. J Nucl Cardiol 8:645–651PubMedCrossRef
33.
Zurück zum Zitat Nanasato M, Ando A, Isobe S, Nonokawa M, Hirayama H, Tsuboi N et al (2001) Evaluation of left ventricular function using electrocardiographically gated myocardial SPECT with (123) I-labeled fatty acid analog. J Nucl Med 42:1747–1756PubMed Nanasato M, Ando A, Isobe S, Nonokawa M, Hirayama H, Tsuboi N et al (2001) Evaluation of left ventricular function using electrocardiographically gated myocardial SPECT with (123) I-labeled fatty acid analog. J Nucl Med 42:1747–1756PubMed
34.
Zurück zum Zitat Schaefer WM, Lipke CS, Standke D, Kuhl HP, Nowak B, Kaiser HJ et al (2005) Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT. J Nucl Med 46:1256–1263PubMed Schaefer WM, Lipke CS, Standke D, Kuhl HP, Nowak B, Kaiser HJ et al (2005) Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT. J Nucl Med 46:1256–1263PubMed
35.
Zurück zum Zitat Schepis T, Gaemperli O, Koepfli P, Valenta I, Strobel K, Brunner A et al (2006) Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function. J Nucl Med 47:1288–1294PubMed Schepis T, Gaemperli O, Koepfli P, Valenta I, Strobel K, Brunner A et al (2006) Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function. J Nucl Med 47:1288–1294PubMed
36.
Zurück zum Zitat Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA et al (2005) Chamber quantification writing group; American Society of Echocardiography’s Guidelines and Standards Committee; European Association of Echocardiography. Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 18:1440–1463 Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA et al (2005) Chamber quantification writing group; American Society of Echocardiography’s Guidelines and Standards Committee; European Association of Echocardiography. Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 18:1440–1463
37.
Zurück zum Zitat Habash-Bseiso DE, Rokey R, Berger CJ, Weier AW, Chyou PH (2005) Accuracy of noninvasive ejection fraction measurement in a large community-based clinic. Clin Med Res 3:75–82PubMedCrossRef Habash-Bseiso DE, Rokey R, Berger CJ, Weier AW, Chyou PH (2005) Accuracy of noninvasive ejection fraction measurement in a large community-based clinic. Clin Med Res 3:75–82PubMedCrossRef
38.
Zurück zum Zitat Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS et al (2003) American College of Cardiology; American Heart Association; American Society for Nuclear Cardiology. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging—executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol 42:1318–1333PubMedCrossRef Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS et al (2003) American College of Cardiology; American Heart Association; American Society for Nuclear Cardiology. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging—executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol 42:1318–1333PubMedCrossRef
Metadaten
Titel
Left ventricular ejection fraction measurements: accuracy and prognostic implications in a large population of patients with known or suspected ischemic heart disease
verfasst von
Alessia Gimelli
Patrizia Landi
Paolo Marraccini
Rosa Sicari
Paolo Frumento
Antonio L’Abbate
Daniele Rovai
Publikationsdatum
01.12.2008
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 8/2008
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-008-9317-1

Weitere Artikel der Ausgabe 8/2008

The International Journal of Cardiovascular Imaging 8/2008 Zur Ausgabe

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Vorhofflimmern bei Jüngeren gefährlicher als gedacht

06.05.2024 Vorhofflimmern Nachrichten

Immer mehr jüngere Menschen leiden unter Vorhofflimmern. Betroffene unter 65 Jahren haben viele Risikofaktoren und ein signifikant erhöhtes Sterberisiko verglichen mit Gleichaltrigen ohne die Erkrankung.

Chronisches Koronarsyndrom: Gefahr von Hospitalisierung wegen Herzinsuffizienz

06.05.2024 Herzinsuffizienz Nachrichten

Obwohl ein rezidivierender Herzinfarkt bei chronischem Koronarsyndrom wahrscheinlich die Hauptsorge sowohl der Patienten als auch der Ärzte ist, sind andere Ereignisse womöglich gefährlicher. Laut einer französischen Studie stellt eine Hospitalisation wegen Herzinsuffizienz eine größere Gefahr dar.

Das Risiko für Vorhofflimmern in der Bevölkerung steigt

02.05.2024 Vorhofflimmern Nachrichten

Das Risiko, im Lauf des Lebens an Vorhofflimmern zu erkranken, ist in den vergangenen 20 Jahren gestiegen: Laut dänischen Zahlen wird es drei von zehn Personen treffen. Das hat Folgen weit über die Schlaganfallgefährdung hinaus.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.