Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 8/2008

01.12.2008 | Original Paper

Accuracy of quantitative coronary angiography with computed tomography and its dependency on plaque composition

Plaque composition and accuracy of cardiac CT

verfasst von: Lars Husmann, Oliver Gaemperli, Tiziano Schepis, Hans Scheffel, Ines Valenta, Tobias Hoefflinghaus, Paul Stolzmann, Lotus Desbiolles, Bernhard A. Herzog, Sebastian Leschka, Borut Marincek, Hatem Alkadhi, Philipp A. Kaufmann

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 8/2008

Einloggen, um Zugang zu erhalten

Abstract

Objective: To determine the impact of plaque composition on accuracy of quantitative 64-slice computed tomography coronary angiography (CTCA). Methods: The institutional review board approved this study; written informed consent was obtained from all patients. One hundred consecutive patients (42 women, mean age 64.6 ± 9.4 years, age range 39–87 years) underwent CTCA and invasive quantitative coronary angiography (QCA) to determine (a) the diagnostic accuracy of CTCA for the detection of significant stenosis (diameter reduction of ≥50%), and (b) the accuracy of stenosis grading. In CTCA stenosis severity was graded in 10% steps and evaluated separately for calcified and non-calcified coronary lesions using Pearson-linear-regression analysis, Bland/Altman-analysis (BA), and Mann-Whitney-U-test. Results: In 60/100 patients 139 significant coronary artery stenoses were identified with QCA. On a per-segment analysis, sensitivity of CTCA was 75.5%, and specificity was 96.6% (positive predictive value: 72.9%, negative predictive value: 97.0%). Quantification of stenosis grading correlated moderately between methods (r = 0.60; P < 0.001), with an overestimation by CTCA of 5.5% (BA limits-of-agreement −29 to 39%). BA limits-of-agreement were greater in calcified lesions (−29.2 to 45.6%; mean error 8.2%) than in non-calcified lesions (−25.9 to 30.2%; mean error 2.2%) and differed significantly (P < 0.05). Conclusions: Diagnostic accuracy of CTCA is high, however agreement for quantitative lesion severity assessment between CTCA and QCA is moderate for calcified but superior for non-calcified lesions.
Literatur
2.
Zurück zum Zitat Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154. doi:10.1016/j.jacc.2005.03.071 PubMedCrossRef Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154. doi:10.​1016/​j.​jacc.​2005.​03.​071 PubMedCrossRef
7.
Zurück zum Zitat Ong TK, Chin SP, Liew CK et al. (2006) Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J 151:1323 e1321–e1326 Ong TK, Chin SP, Liew CK et al. (2006) Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J 151:1323 e1321–e1326
8.
Zurück zum Zitat Ehara M, Surmely JF, Kawai M et al (2006) Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J 70:564–571. doi:10.1253/circj.70.564 PubMedCrossRef Ehara M, Surmely JF, Kawai M et al (2006) Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J 70:564–571. doi:10.​1253/​circj.​70.​564 PubMedCrossRef
9.
Zurück zum Zitat Ropers D, Rixe J, Anders K et al (2006) Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. Am J Cardiol 97:343–348. doi:10.1016/j.amjcard.2005.08.050 PubMedCrossRef Ropers D, Rixe J, Anders K et al (2006) Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses. Am J Cardiol 97:343–348. doi:10.​1016/​j.​amjcard.​2005.​08.​050 PubMedCrossRef
10.
Zurück zum Zitat Meijboom WB, Mollet NR, van Mieghem CA et al. (2007 [Epub ahead of print]) 64-slice computed tomography coronary angiography in patients with non-ST elevation acute coronary syndrome. Heart Meijboom WB, Mollet NR, van Mieghem CA et al. (2007 [Epub ahead of print]) 64-slice computed tomography coronary angiography in patients with non-ST elevation acute coronary syndrome. Heart
11.
Zurück zum Zitat Gould KL (1988) Percent coronary stenosis: battered gold standard, pernicious relic or clinical practicality? J Am Coll Cardiol 11:886–888PubMedCrossRef Gould KL (1988) Percent coronary stenosis: battered gold standard, pernicious relic or clinical practicality? J Am Coll Cardiol 11:886–888PubMedCrossRef
13.
Zurück zum Zitat Cury RC, Ferencik M, Achenbach S et al (2006) Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: assessment of cross-sectional and longitudinal vessel reconstructions. Eur J Radiol 57:345–350. doi:10.1016/j.ejrad.2005.12.019 PubMedCrossRef Cury RC, Ferencik M, Achenbach S et al (2006) Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: assessment of cross-sectional and longitudinal vessel reconstructions. Eur J Radiol 57:345–350. doi:10.​1016/​j.​ejrad.​2005.​12.​019 PubMedCrossRef
14.
Zurück zum Zitat Achenbach S, Giesler T, Ropers D et al (2001) Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography. Circulation 103:2535–2538PubMed Achenbach S, Giesler T, Ropers D et al (2001) Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography. Circulation 103:2535–2538PubMed
15.
Zurück zum Zitat Kuettner A, Trabold T, Schroeder S et al (2004) Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol 44:1230–1237PubMed Kuettner A, Trabold T, Schroeder S et al (2004) Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: initial clinical results. J Am Coll Cardiol 44:1230–1237PubMed
18.
Zurück zum Zitat Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed
19.
22.
Zurück zum Zitat Cademartiri F, La Grutta L, Runza G et al (2007) Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography. Eur Radiol 17:1842–1849. doi:10.1007/s00330-006-0548-z PubMedCrossRef Cademartiri F, La Grutta L, Runza G et al (2007) Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography. Eur Radiol 17:1842–1849. doi:10.​1007/​s00330-006-0548-z PubMedCrossRef
23.
24.
Zurück zum Zitat Topol EJ, Nissen SE (1995) Our preoccupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease. Circulation 92:2333–2342PubMed Topol EJ, Nissen SE (1995) Our preoccupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease. Circulation 92:2333–2342PubMed
25.
Zurück zum Zitat Arnett EN, Isner JM, Redwood DR et al (1979) Coronary artery narrowing in coronary heart disease: comparison of cineangiographic and necropsy findings. Ann Intern Med 91:350–356PubMed Arnett EN, Isner JM, Redwood DR et al (1979) Coronary artery narrowing in coronary heart disease: comparison of cineangiographic and necropsy findings. Ann Intern Med 91:350–356PubMed
26.
Zurück zum Zitat Grondin CM, Dyrda I, Pasternac A et al (1974) Discrepancies between cineangiographic and postmortem findings in patients with coronary artery disease and recent myocardial revascularization. Circulation 49:703–708PubMed Grondin CM, Dyrda I, Pasternac A et al (1974) Discrepancies between cineangiographic and postmortem findings in patients with coronary artery disease and recent myocardial revascularization. Circulation 49:703–708PubMed
27.
Zurück zum Zitat White CW, Wright CB, Doty DB et al (1984) Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis? N Engl J Med 310:819–824PubMed White CW, Wright CB, Doty DB et al (1984) Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis? N Engl J Med 310:819–824PubMed
30.
Zurück zum Zitat Scheffel H, Alkadhi H, Plass A et al (2006) Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 16:2739–2747. doi:10.1007/s00330-006-0474-0 PubMedCrossRef Scheffel H, Alkadhi H, Plass A et al (2006) Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 16:2739–2747. doi:10.​1007/​s00330-006-0474-0 PubMedCrossRef
Metadaten
Titel
Accuracy of quantitative coronary angiography with computed tomography and its dependency on plaque composition
Plaque composition and accuracy of cardiac CT
verfasst von
Lars Husmann
Oliver Gaemperli
Tiziano Schepis
Hans Scheffel
Ines Valenta
Tobias Hoefflinghaus
Paul Stolzmann
Lotus Desbiolles
Bernhard A. Herzog
Sebastian Leschka
Borut Marincek
Hatem Alkadhi
Philipp A. Kaufmann
Publikationsdatum
01.12.2008
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 8/2008
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-008-9327-z

Weitere Artikel der Ausgabe 8/2008

The International Journal of Cardiovascular Imaging 8/2008 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.