Comparison Between Cardiac Output Measured by the Pulmonary Arterial Thermodilution Technique and that Measured by the Femoral Arterial Thermodilution Technique in a Pediatric Animal Model

verfasst von: M. Rupérez, J. López-Herce, C. García, C. Sánchez, E. García, D. Vigil

Erschienen in: Pediatric Cardiology | Ausgabe 2/2004

Einloggen, um Zugang zu erhalten

Abstract

This study compares the correlation between two methods for the determination of cardiac output—the pulmonary arterial thermodilution technique using the Swan–Ganz catheter and the femoral arterial thermodilution technique using a pulse contour analysis computer (PiCCO) catheter. We performed a prospective animal study using 16 immature Maryland pigs weighing 9 to 16 kg. A 5.5- or 7.5-Fr Swan–Ganz catheter was introduced into the femoral or jugular vein, and a 4- or 5-Fr arterial PiCCO catheter was introduced into the femoral artery. In each animal, we made measurements of cardiac output at 30-minute intervals, simultaneously by pulmonary arterial thermodilution and femoral arterial thermodilution, before, during, and after hemodiafiltration carried out via different venous catheters, recording a total of 78 measurements. The mean Swan–Ganz cardiac output was 2.22 ± 0.94 L/min, and mean PiCCO cardiac output was 1.94 ± 0.80 L/min (no significant difference). The mean difference (bias) of differences (limits of agreement) was 0.2812. The differences between the methods increased with higher cardiac output, but the percentage differences in relation to cardiac output remained stable. Good correlation was found between the two methods: single-measure intraclass correlation was 0.8892 (95% confidence interval, 0.54–0.95). There were no differences between the 5.5- and 7.5-FR Swan–Ganz catheters or between the 4- and 5-Fr PiCCO catheters. Femoral arterial thermodilution cardiac output measurements correlated well with pulmonary arterial thermodilution cardiac output measurements in a pediatric animal model.
Literatur
1.
Zurück zum Zitat Antonini, M, Meloncelli, S, Dantimi, C, et al. 2001PiCCO System con accesso arterioso brachio-ascellare nel monitoraggio emodinamico degli interventi per aneurisma dell‘aorta abdomianle.Minerva Anestesiol67447456PubMed Antonini, M, Meloncelli, S, Dantimi, C,  et al. 2001PiCCO System con accesso arterioso brachio-ascellare nel monitoraggio emodinamico degli interventi per aneurisma dell‘aorta abdomianle.Minerva Anestesiol67447456PubMed
2.
Zurück zum Zitat Berkenstadt, H, Margalit, N, Hadani, M, et al. 2001Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery.Anesth Analg92984989PubMed Berkenstadt, H, Margalit, N, Hadani, M,  et al. 2001Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery.Anesth Analg92984989PubMed
3.
Zurück zum Zitat Bland, JM, Altman, DG 1986Statistical methods for assessing agreement between two methods of clinical measurement.Lancet1307311PubMed Bland, JM, Altman, DG 1986Statistical methods for assessing agreement between two methods of clinical measurement.Lancet1307311PubMed
4.
Zurück zum Zitat Böck, JC, Barker, BC, Mackersie, RC, Tranbaugh, RF 1989Cardiac output measurements using femoral artery thermodilution in patients.J Crit Care4106111 Böck, JC, Barker, BC, Mackersie, RC, Tranbaugh, RF 1989Cardiac output measurements using femoral artery thermodilution in patients.J Crit Care4106111
5.
Zurück zum Zitat Boeck, JC, Deuflhard, P, Hoeft, A 1988Thermal recovery after passage of the pulmonary circulation assessed by deconvolution.J Appl Physiol6412101216PubMed Boeck, JC, Deuflhard, P, Hoeft, A 1988Thermal recovery after passage of the pulmonary circulation assessed by deconvolution.J Appl Physiol6412101216PubMed
6.
Zurück zum Zitat Buhre, W, Weyland, A, Kazmaier, S, et al. 1999Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting.J Cardiothorac Vasc Anesth13437440PubMed Buhre, W, Weyland, A, Kazmaier, S,  et al. 1999Comparison of cardiac output assessed by pulse-contour analysis and thermodilution in patients undergoing minimally invasive direct coronary artery bypass grafting.J Cardiothorac Vasc Anesth13437440PubMed
7.
Zurück zum Zitat Chang, AC, Kulik, TJ, Hickey, PR, Wessel, DL 1993Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.Crit Care Med2113691375PubMed Chang, AC, Kulik, TJ, Hickey, PR, Wessel, DL 1993Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.Crit Care Med2113691375PubMed
8.
Zurück zum Zitat Goedje, O, Hoeke, K, Lamm, P, et al. 1998Continuous, less invasive, hemodynamic monitoring in intensive care after cardiac surgery.Thorac Cardiovasc Surg46242249 Goedje, O, Hoeke, K, Lamm, P,  et al. 1998Continuous, less invasive, hemodynamic monitoring in intensive care after cardiac surgery.Thorac Cardiovasc Surg46242249
9.
Zurück zum Zitat Goedje, O, Hoeke, K, Lichtwarck-Aschoff, M, et al. 1999Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution.Crit Care Med2724072412PubMed Goedje, O, Hoeke, K, Lichtwarck-Aschoff, M,  et al. 1999Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution.Crit Care Med2724072412PubMed
10.
Zurück zum Zitat Gust, R, Gottschalk, A, Bauer, H, et al. 1998Cardiac output measurement by transpulmonary versus conventional thermodilution technique in intensive care patients after coronary artery bypass grafting.J Cardiothorac Vasc Anesth12519522PubMed Gust, R, Gottschalk, A, Bauer, H,  et al. 1998Cardiac output measurement by transpulmonary versus conventional thermodilution technique in intensive care patients after coronary artery bypass grafting.J Cardiothorac Vasc Anesth12519522PubMed
11.
Zurück zum Zitat Harris, AP, Miller, CF, Beattie, C, Rosenfeld, GI, Rogers, MC 1985The slowing of sinus rhythm during thermodilution cardiac output determination and the effect of altering injectate temperature.Anesthesiology63540541PubMed Harris, AP, Miller, CF, Beattie, C, Rosenfeld, GI, Rogers, MC 1985The slowing of sinus rhythm during thermodilution cardiac output determination and the effect of altering injectate temperature.Anesthesiology63540541PubMed
12.
Zurück zum Zitat Hillis, LD, Firth, BG, Winniford, MD 1985Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output.Am J Cardiol56764768PubMed Hillis, LD, Firth, BG, Winniford, MD 1985Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output.Am J Cardiol56764768PubMed
13.
Zurück zum Zitat Holm, C, Melcer, B, Horbrad, F, Henckel von Donnersmarck, G, Muhlbauer, W 2001Arterial thermodilution: an alternative to pulmonary artery catheter for cardiac output assessment in burn patients.Burns27161166CrossRefPubMed Holm, C, Melcer, B, Horbrad, F, Henckel von Donnersmarck, G, Muhlbauer, W 2001Arterial thermodilution: an alternative to pulmonary artery catheter for cardiac output assessment in burn patients.Burns27161166CrossRefPubMed
14.
Zurück zum Zitat Lewis, FR, Elings, VB, Hill, SL, Christensen, JM 1982The measurement of extravascular lung water by thermal-green dye indicator dilution.Ann N Y Acad Sci384394410PubMed Lewis, FR, Elings, VB, Hill, SL, Christensen, JM 1982The measurement of extravascular lung water by thermal-green dye indicator dilution.Ann N Y Acad Sci384394410PubMed
15.
Zurück zum Zitat Marx, G, Sumpelmann, R, Schuerholz, T, et al. 2000Cardiac output measurement by arterial thermodilution in piglets.Anaesth Analg905758 Marx, G, Sumpelmann, R, Schuerholz, T,  et al. 2000Cardiac output measurement by arterial thermodilution in piglets.Anaesth Analg905758
16.
Zurück zum Zitat McLuckie, A, Murdoch, IA, Marsh, ., Anderson, D 1996A comparison of pulmonary and femoral artery thermodilution cardiac indices in paediatric intensive care patients.Acta Paediatr85336338PubMed McLuckie, A, Murdoch, IA, Marsh, ., Anderson, D 1996A comparison of pulmonary and femoral artery thermodilution cardiac indices in paediatric intensive care patients.Acta Paediatr85336338PubMed
17.
Zurück zum Zitat Mellander, M, Sabel, KG, Caidahl, K, Solymar, L, Eriksson, B 1987Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution.Pediatr Cardiol8241246PubMed Mellander, M, Sabel, KG, Caidahl, K, Solymar, L, Eriksson, B 1987Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution.Pediatr Cardiol8241246PubMed
18.
Zurück zum Zitat Morrow, WR, Murphy, DJ, Fisher, DJ, et al. 1988Continuous wave Doppler cardiac output: use in pediatric patients receiving inotropic support.Pediatr Cardiol9131136PubMed Morrow, WR, Murphy, DJ, Fisher, DJ,  et al. 1988Continuous wave Doppler cardiac output: use in pediatric patients receiving inotropic support.Pediatr Cardiol9131136PubMed
19.
Zurück zum Zitat Murdoch, IA, Marsh, MJ, Morrison, G 1995Measurement of cardiac output in children.Vincent, J-L eds. Year Book of Intensive Care and Emergency Medicine.SpringerBerlin606614 Murdoch, IA, Marsh, MJ, Morrison, G 1995Measurement of cardiac output in children.Vincent, J-L eds. Year Book of Intensive Care and Emergency Medicine.SpringerBerlin606614
20.
Zurück zum Zitat Perrino, AC, Lippman, A, Ariyan, C 1994Intraoperative cardiac output monitoring: comparison of impedance cardiography and thermodilution.J Cardiothorac Vasc Anesth82429PubMed Perrino, AC, Lippman, A, Ariyan, C 1994Intraoperative cardiac output monitoring: comparison of impedance cardiography and thermodilution.J Cardiothorac Vasc Anesth82429PubMed
21.
Zurück zum Zitat Rodig, G, Prasser, C, Keyl, C, Liebold, A, Hobbhahn, J 1999Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients.Br J Anaesth82525530PubMed Rodig, G, Prasser, C, Keyl, C, Liebold, A, Hobbhahn, J 1999Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients.Br J Anaesth82525530PubMed
22.
Zurück zum Zitat Sakka, SG, Reinhart, K, Meier-Hellmann, A 1999Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients.Intensive Care Med25843846CrossRefPubMed Sakka, SG, Reinhart, K, Meier-Hellmann, A 1999Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients.Intensive Care Med25843846CrossRefPubMed
23.
Zurück zum Zitat Senzaki, H, Chen, CH, Masutani, S, et al. 2001Assessment of cardiovascular dynamics by pressure-area relation in pediatric patients with congenital heart disease.J Thorac Cardiovasc Surg122535547CrossRefPubMed Senzaki, H, Chen, CH, Masutani, S,  et al. 2001Assessment of cardiovascular dynamics by pressure-area relation in pediatric patients with congenital heart disease.J Thorac Cardiovasc Surg122535547CrossRefPubMed
24.
Zurück zum Zitat Tibby, SM, Hatherill, M, Marsh, MJ, et al. 1997Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants.Intensive Care Med23987991PubMed Tibby, SM, Hatherill, M, Marsh, MJ,  et al. 1997Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants.Intensive Care Med23987991PubMed
25.
Zurück zum Zitat Valtier, B, Cholley, BP, Belot, JP 1998Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler.Am J Respir Crit Care Med1587783 Valtier, B, Cholley, BP, Belot, JP 1998Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler.Am J Respir Crit Care Med1587783
26.
Zurück zum Zitat Van Grondelle, A, Ditchey, RV, Groves, BM, Wagner Jr, WW, Reeves, JT 1983Thermodilution method overestimates low cardiac output in humans.Am J Phvsiol245H690H692 Van Grondelle, A, Ditchey, RV, Groves, BM, Wagner Jr, WW, Reeves, JT 1983Thermodilution method overestimates low cardiac output in humans.Am J Phvsiol245H690H692
27.
Zurück zum Zitat Von Spiegel, T, Wietasch, G, Bursch, J, Hoeft, A 1996A cardiac output determination with transpulmonary thermodilution: an alternative to pulmonary catheterization?Anaesthesist4510451050PubMed Von Spiegel, T, Wietasch, G, Bursch, J, Hoeft, A 1996A cardiac output determination with transpulmonary thermodilution: an alternative to pulmonary catheterization?Anaesthesist4510451050PubMed
28.
Zurück zum Zitat Zollner, C, Haller, M, Weis, M, et al. 2000Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery.J Cardiothorac Vasc Anesth14125129PubMed Zollner, C, Haller, M, Weis, M,  et al. 2000Beat-to-beat measurement of cardiac output by intravascular pulse contour analysis: a prospective criterion standard study in patients after cardiac surgery.J Cardiothorac Vasc Anesth14125129PubMed
Metadaten
Titel
Comparison Between Cardiac Output Measured by the Pulmonary Arterial Thermodilution Technique and that Measured by the Femoral Arterial Thermodilution Technique in a Pediatric Animal Model
verfasst von
M. Rupérez
J. López-Herce
C. García
C. Sánchez
E. García
D. Vigil
Publikationsdatum
01.04.2004
Erschienen in
Pediatric Cardiology / Ausgabe 2/2004
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-003-0450-2

Weitere Artikel der Ausgabe 2/2004

Pediatric Cardiology 2/2004 Zur Ausgabe

OriginalPaper

From Other Journals

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

„Jeder Fall von plötzlichem Tod muss obduziert werden!“

17.05.2024 Plötzlicher Herztod Nachrichten

Ein signifikanter Anteil der Fälle von plötzlichem Herztod ist genetisch bedingt. Um ihre Verwandten vor diesem Schicksal zu bewahren, sollten jüngere Personen, die plötzlich unerwartet versterben, ausnahmslos einer Autopsie unterzogen werden.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Schlechtere Vorhofflimmern-Prognose bei kleinem linken Ventrikel

17.05.2024 Vorhofflimmern Nachrichten

Nicht nur ein vergrößerter, sondern auch ein kleiner linker Ventrikel ist bei Vorhofflimmern mit einer erhöhten Komplikationsrate assoziiert. Der Zusammenhang besteht nach Daten aus China unabhängig von anderen Risikofaktoren.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.