Skip to main content
Erschienen in: International Orthopaedics 6/2022

29.03.2022 | Original Paper

Comminuted AO-C3 fractures of the patella: good outcome using anatomically contoured locking plate fixation

verfasst von: Stefan Buschbeck, Kristina Götz, Alexander Klug, Stefan Barzen, Yves Gramlich, Reinhard Hoffmann

Erschienen in: International Orthopaedics | Ausgabe 6/2022

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The treatment of comminuted patellar fractures remains a challenge for orthopedic surgeons. The aim of this study was to assess the clinical, functional, and radiological outcome after treatment of comminuted patellar fractures using an anatomically contoured plating system.

Methods

Between January 2015 and December 2019 (5 years), 29 patients with complex C3 fractures according to AO classification (18 female, 11 male; mean age: 53 years) were treated using an anatomically contoured plating system (patella SuturePlate™, Arthrex®, Naples, USA). Indication for surgery was based on instability and/or initial fragment dislocation (> 2 mm). After a minimum follow-up of 12 months, patients were examined using a standardized clinical examination and functional outcome was assessed using specific knee scores (Lysholm, WOMAC, IKDC, Kujala, and Tegner score). In addition, complications were recorded and all available radiographs were evaluated regarding osteoarthritis and reduction quality.

Results

All patients returned for follow-up investigation after an average of 19 months (range: 12–48 months). A mean range of motion (ROM) of 131° (range: 100–150) was recorded. Overall good functional outcome parameters could be reported, with a mean Lysholm score of 84.7 (range: 100–45), a WOMAC of 5.1 (range: 0–19.2), a Kujala scale of 85.5 (range: 100–48), an IKDC of 76.6 (range: 100–44.8), and a Tegner score of 4.3 (range: 10–3) with a difference of 0.62 to pre-operative. Patient satisfaction was rated 8.4 (range: 4–10) using a VAS. No loss of reduction, mechanical failure, or implant complications were detected. Radiological follow-up showed no evidence of relevant post-traumatic retropatellar osteoarthritis. In 7 cases, implants were removed due to subjective mechanical irritation.

Conclusion

Anatomically contoured patellar plates allow secure fixation of the fracture fragments even in comminuted cases. Especially when tension-band wiring is prone to early failure, locking plate fixation represents a viable option leading to good functional results and low complication rates.
Literatur
6.
Zurück zum Zitat Schüttrumpf JP, Piatek S, Stürmer KM (2019) Patellafraktur. Leitlinien Unfallchirurgie. AWMF-Nr. 012-017 Schüttrumpf JP, Piatek S, Stürmer KM (2019) Patellafraktur. Leitlinien Unfallchirurgie. AWMF-Nr. 012-017
9.
Zurück zum Zitat Müller ME, Allgöwer M, Schneider R, et al. (1990) Manual der Osteosynthese, 3rd edn. Springer Verlag, Berlin, Heidelberg, New York Müller ME, Allgöwer M, Schneider R, et al. (1990) Manual der Osteosynthese, 3rd edn. Springer Verlag, Berlin, Heidelberg, New York
17.
Zurück zum Zitat Tegner Y, Lysholm J (1985) Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res 198:43–49 Tegner Y, Lysholm J (1985) Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res 198:43–49
20.
Zurück zum Zitat Bellamy N (2005) The WOMAC knee and hip osteoarthritis indices: development, validation, globalization and influence on the development of the AUSCAN hand osteoarthritis indices. Clin Exp Rheumatol 23:S148-153PubMed Bellamy N (2005) The WOMAC knee and hip osteoarthritis indices: development, validation, globalization and influence on the development of the AUSCAN hand osteoarthritis indices. Clin Exp Rheumatol 23:S148-153PubMed
Metadaten
Titel
Comminuted AO-C3 fractures of the patella: good outcome using anatomically contoured locking plate fixation
verfasst von
Stefan Buschbeck
Kristina Götz
Alexander Klug
Stefan Barzen
Yves Gramlich
Reinhard Hoffmann
Publikationsdatum
29.03.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 6/2022
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-022-05374-5

Weitere Artikel der Ausgabe 6/2022

International Orthopaedics 6/2022 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Traumatologische Notfälle Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.