Skip to main content
Erschienen in: European Radiology 10/2003

01.10.2003 | Magnetic Resonance

A brief review of parallel magnetic resonance imaging

verfasst von: Robin M. Heidemann, Özkan Özsarlak, Paul M. Parizel, Johan Michiels, Berthold Kiefer, Vladimir Jellus, Mathias Müller, Felix Breuer, Martin Blaimer, Mark A. Griswold, Peter M. Jakob

Erschienen in: European Radiology | Ausgabe 10/2003

Einloggen, um Zugang zu erhalten

Abstract

Since the 1980s, the implementation of fast imaging methods and dedicated hardware for MRI scanners has reduced the image acquisition time from nearly an hour down to several seconds and has therefore enabled a widespread use of MRI in clinical diagnosis. Since this development, the greatest incremental gain in imaging speed has been provided by the development of parallel MRI (pMRI) techniques in late 1990s. Within the past 2 years, parallel imaging methods have become commercially available, which means that pMRI is now available for broad clinical use. In the clinical routine, virtually any MRI method can be enhanced by pMRI, allowing faster image acquisitions without any increased gradient system performance. In some cases pMRI can even result in a significant gain in image quality due to this faster acquisition. In this review article, the advantages and the disadvantages of pMRI in clinical applications are discussed and examples from many different daily applications are given.
Literatur
1.
Zurück zum Zitat Mansfield P (1977) Multi-planar image formation using NMR spin-echoes. J Phys C Solid State 10:L55–L58CrossRef Mansfield P (1977) Multi-planar image formation using NMR spin-echoes. J Phys C Solid State 10:L55–L58CrossRef
2.
Zurück zum Zitat Haase A, Frahm J, Matthaei D, Hänicke W, Merboldt KD (1986) FLASH imaging: rapid NMR imaging using low flip-angle pulses. J Magn Reson 67:258–266 Haase A, Frahm J, Matthaei D, Hänicke W, Merboldt KD (1986) FLASH imaging: rapid NMR imaging using low flip-angle pulses. J Magn Reson 67:258–266
3.
Zurück zum Zitat Hennig J, Nauerth A, Friedburg H (1986) RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 3:823–833PubMed Hennig J, Nauerth A, Friedburg H (1986) RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 3:823–833PubMed
4.
Zurück zum Zitat Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM (1990) The NMR phased array. Magn Reson Med 16:192–225PubMed Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM (1990) The NMR phased array. Magn Reson Med 16:192–225PubMed
5.
Zurück zum Zitat Hayes CE, Roemer PB (1990) Noise correlations in data simultaneously acquired from multiple surface coil arrays. Magn Reson Med 16:181–191PubMed Hayes CE, Roemer PB (1990) Noise correlations in data simultaneously acquired from multiple surface coil arrays. Magn Reson Med 16:181–191PubMed
6.
Zurück zum Zitat Hutchinson M, Raff U (1988) Fast MRI data acquisition using multiple detectors. Magn Reson Med 6:87–91PubMed Hutchinson M, Raff U (1988) Fast MRI data acquisition using multiple detectors. Magn Reson Med 6:87–91PubMed
7.
Zurück zum Zitat Kwiat D, Einav S, Navon G (1991) A decoupled coil detector array for fast image acquisition in magnetic resonance imaging. Med Phys 18:251–265CrossRefPubMed Kwiat D, Einav S, Navon G (1991) A decoupled coil detector array for fast image acquisition in magnetic resonance imaging. Med Phys 18:251–265CrossRefPubMed
8.
Zurück zum Zitat Kwiat D, Einav S (1995) Preliminary experimental evaluation of an inverse source imaging procedure using a decoupled coil detector array in magnetic resonance imaging. Med Eng Phys 17:257–263CrossRefPubMed Kwiat D, Einav S (1995) Preliminary experimental evaluation of an inverse source imaging procedure using a decoupled coil detector array in magnetic resonance imaging. Med Eng Phys 17:257–263CrossRefPubMed
9.
Zurück zum Zitat Kelton JR, Magin RL, Wright SM (1989) An algorithm for rapid image acquisition using multiple receiver coils. In: Proc 8th Annual Meeting of SMRM, p 1172 Kelton JR, Magin RL, Wright SM (1989) An algorithm for rapid image acquisition using multiple receiver coils. In: Proc 8th Annual Meeting of SMRM, p 1172
10.
Zurück zum Zitat Ra JB, Rim CY (1993) Fast imaging using subencoding data sets from multiple detectors. Magn Reson Med 30:142–145PubMed Ra JB, Rim CY (1993) Fast imaging using subencoding data sets from multiple detectors. Magn Reson Med 30:142–145PubMed
11.
Zurück zum Zitat Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962CrossRefPubMed Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42:952–962CrossRefPubMed
12.
Zurück zum Zitat Carlson JW (1987) An algorithm for NMR imaging reconstruction based on multiple RF receiver coils. J Magn Reson 74:376–380 Carlson JW (1987) An algorithm for NMR imaging reconstruction based on multiple RF receiver coils. J Magn Reson 74:376–380
13.
Zurück zum Zitat Carlson JW, Minemura T (1993) Imaging time reduction through multiple receiver coil data acquisition and image reconstruction. Magn Reson Med 29:681–688PubMed Carlson JW, Minemura T (1993) Imaging time reduction through multiple receiver coil data acquisition and image reconstruction. Magn Reson Med 29:681–688PubMed
14.
Zurück zum Zitat Sodickson DK, Manning WJ (1997) Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radio-frequency coil arrays. Magn Reson Med 38:591–603PubMed Sodickson DK, Manning WJ (1997) Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radio-frequency coil arrays. Magn Reson Med 38:591–603PubMed
15.
Zurück zum Zitat Jakob PM, Griswold MA, Edelman RR, Sodickson DK (1998) AUTO-SMASH, a self-calibrating technique for SMASH imaging. MAGMA 7:42–54CrossRefPubMed Jakob PM, Griswold MA, Edelman RR, Sodickson DK (1998) AUTO-SMASH, a self-calibrating technique for SMASH imaging. MAGMA 7:42–54CrossRefPubMed
16.
Zurück zum Zitat Heidemann RM, Griswold MA, Haase A, Jakob PM (2001) VD-AUTO-SMASH imaging. Magn Reson Med 45:1066–1074CrossRefPubMed Heidemann RM, Griswold MA, Haase A, Jakob PM (2001) VD-AUTO-SMASH imaging. Magn Reson Med 45:1066–1074CrossRefPubMed
17.
Zurück zum Zitat Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202–1210CrossRefPubMed Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202–1210CrossRefPubMed
18.
Zurück zum Zitat Sodickson DK (2000) Tailored SMASH image reconstruction for robust in-vivo parallel MR imaging. Magn Reson Med 44:243–251CrossRefPubMed Sodickson DK (2000) Tailored SMASH image reconstruction for robust in-vivo parallel MR imaging. Magn Reson Med 44:243–251CrossRefPubMed
19.
Zurück zum Zitat Kyriakos WE, Panych LP, Kacher DK, Westin CF, Bao SM, Mulkern RV, Jolesz FA (2000) Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP). Magn Reson Med 44:301–308CrossRefPubMed Kyriakos WE, Panych LP, Kacher DK, Westin CF, Bao SM, Mulkern RV, Jolesz FA (2000) Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP). Magn Reson Med 44:301–308CrossRefPubMed
20.
Zurück zum Zitat Griswold MA, Jakob PM, Nittka M, Goldfarb JW, Haase A (2000) Partially parallel imaging with localized sensitivities (PILS). Magn Reson Med 44:602–609CrossRefPubMed Griswold MA, Jakob PM, Nittka M, Goldfarb JW, Haase A (2000) Partially parallel imaging with localized sensitivities (PILS). Magn Reson Med 44:602–609CrossRefPubMed
21.
Zurück zum Zitat Constable RT, Gore JC (1992) The loss of small objects in variable TE imaging: implications for FSE, RARE and EPI. Magn Reson Med 28:9–24PubMed Constable RT, Gore JC (1992) The loss of small objects in variable TE imaging: implications for FSE, RARE and EPI. Magn Reson Med 28:9–24PubMed
22.
Zurück zum Zitat Griswold MA, Jakob PM, Chen Q, Goldfarb J, Manning WJ, Edelman RR, Sodickson DK (1999) Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH). Magn Reson Med 41:1236–1245CrossRefPubMed Griswold MA, Jakob PM, Chen Q, Goldfarb J, Manning WJ, Edelman RR, Sodickson DK (1999) Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH). Magn Reson Med 41:1236–1245CrossRefPubMed
23.
Zurück zum Zitat Griswold MA, Jakob PM, Edelman RR, Sodickson DK (1998) Alternative EPI-acquisition strategies using SMASH. In: Proc 6th Annual Meeting of the ISMRM, Sidney, Australia, p 423 Griswold MA, Jakob PM, Edelman RR, Sodickson DK (1998) Alternative EPI-acquisition strategies using SMASH. In: Proc 6th Annual Meeting of the ISMRM, Sidney, Australia, p 423
24.
Zurück zum Zitat Griswold MA, Jakob PM, Heidemann RM, Nittka M, Wang J, Kiefer B, Haase A (2001) Off-resonance artifacts in single-shot EPI using partially parallel imaging. In: Proc 9th Annual Meeting of the ISMRM, Glasgow, Scotland, p 446 Griswold MA, Jakob PM, Heidemann RM, Nittka M, Wang J, Kiefer B, Haase A (2001) Off-resonance artifacts in single-shot EPI using partially parallel imaging. In: Proc 9th Annual Meeting of the ISMRM, Glasgow, Scotland, p 446
25.
Zurück zum Zitat Heidemann RM, Griswold MA, Porter D, Kiefer B, Nittka M, Wang J, Haase A, Jakob PM (2001) Minimizing distortions and blurring in diffusion weighted single-shot EPI using high performance gradients in combination with parallel imaging. In: Proc 9th Annual Meeting of the ISMRM, Glasgow, Scotland, p 169 Heidemann RM, Griswold MA, Porter D, Kiefer B, Nittka M, Wang J, Haase A, Jakob PM (2001) Minimizing distortions and blurring in diffusion weighted single-shot EPI using high performance gradients in combination with parallel imaging. In: Proc 9th Annual Meeting of the ISMRM, Glasgow, Scotland, p 169
26.
Zurück zum Zitat Bammer R, Keeling SL, Augustin M, Pruessmann KP, Wolf R, Stollberger R, Hartung HP, Fazekas F (2001) Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med 46:548–554CrossRefPubMed Bammer R, Keeling SL, Augustin M, Pruessmann KP, Wolf R, Stollberger R, Hartung HP, Fazekas F (2001) Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med 46:548–554CrossRefPubMed
27.
Zurück zum Zitat Kiefer B, Grassner J, Hausmann R (1994) Image acquisition in a second with half-Fourier acquisition single-shot turbo spin-echo. J Magn Reson Imaging 4:86–87 Kiefer B, Grassner J, Hausmann R (1994) Image acquisition in a second with half-Fourier acquisition single-shot turbo spin-echo. J Magn Reson Imaging 4:86–87
28.
Zurück zum Zitat Hatabu H, Gaa J, Tadamura E, Edinburgh KJ, Stock KW, Garpestad E, Edelman RR (1999) MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence. Eur J Radiol 29:152–159CrossRefPubMed Hatabu H, Gaa J, Tadamura E, Edinburgh KJ, Stock KW, Garpestad E, Edelman RR (1999) MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence. Eur J Radiol 29:152–159CrossRefPubMed
29.
Zurück zum Zitat Heidemann RM, Griswold MA, Kiefer B, Nittka M, Wang J, Jellus V, Jakob PM (2003) Resolution enhancement in lung 1H imaging using parallel imaging methods. Magn Reson Med 49:391–394CrossRefPubMed Heidemann RM, Griswold MA, Kiefer B, Nittka M, Wang J, Jellus V, Jakob PM (2003) Resolution enhancement in lung 1H imaging using parallel imaging methods. Magn Reson Med 49:391–394CrossRefPubMed
30.
Zurück zum Zitat Oppelt A, Graumann R, Barfuss H, Fischer H, Hartl W, Schajor W (1986) FISP: a fast new MRI sequence. Electromedica 54:15–18 Oppelt A, Graumann R, Barfuss H, Fischer H, Hartl W, Schajor W (1986) FISP: a fast new MRI sequence. Electromedica 54:15–18
31.
Zurück zum Zitat Jakob PM, Griswold MA, Edelman RR, Manning WJ, Sodickson DK (1999) Accelerated cardiac imaging using the SMASH technique. J Cardiovasc Magn Reson 1:153–157PubMed Jakob PM, Griswold MA, Edelman RR, Manning WJ, Sodickson DK (1999) Accelerated cardiac imaging using the SMASH technique. J Cardiovasc Magn Reson 1:153–157PubMed
32.
Zurück zum Zitat Pruessmann KP, Weiger M, Boesiger P (2001) Sensitivity encoded cardiac MRI. J Cardiovasc Magn Reson 3:1–9CrossRefPubMed Pruessmann KP, Weiger M, Boesiger P (2001) Sensitivity encoded cardiac MRI. J Cardiovasc Magn Reson 3:1–9CrossRefPubMed
33.
Zurück zum Zitat Weiger M, Pruessmann KP, Kassner A, Roditi G, Lawton T, Reid A, Boesiger P (2000) Contrast-enhanced 3D MRA using SENSE. J Magn Reson Imaging 12:671–677PubMed Weiger M, Pruessmann KP, Kassner A, Roditi G, Lawton T, Reid A, Boesiger P (2000) Contrast-enhanced 3D MRA using SENSE. J Magn Reson Imaging 12:671–677PubMed
34.
Zurück zum Zitat Heidemann RM, Benfield A, Griswold MA, Haase A, Jakob PM (2002) General considerations about the CNR in diffusion-weighted EPI using partially parallel acquisition methods. In: Proc 10th Annual Meeting of the ISMRM, Honolulu, Hawaii, p 2414 Heidemann RM, Benfield A, Griswold MA, Haase A, Jakob PM (2002) General considerations about the CNR in diffusion-weighted EPI using partially parallel acquisition methods. In: Proc 10th Annual Meeting of the ISMRM, Honolulu, Hawaii, p 2414
Metadaten
Titel
A brief review of parallel magnetic resonance imaging
verfasst von
Robin M. Heidemann
Özkan Özsarlak
Paul M. Parizel
Johan Michiels
Berthold Kiefer
Vladimir Jellus
Mathias Müller
Felix Breuer
Martin Blaimer
Mark A. Griswold
Peter M. Jakob
Publikationsdatum
01.10.2003
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 10/2003
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1992-7

Weitere Artikel der Ausgabe 10/2003

European Radiology 10/2003 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.