Skip to main content
Erschienen in: European Radiology 7/2004

01.07.2004 | Chest

Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions

verfasst von: Michel Montaudon, Valerie Latrabe, Antoine Pariente, Olivier Corneloup, Hugues Begueret, François Laurent

Erschienen in: European Radiology | Ausgabe 7/2004

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to evaluate the performance and complication rate of CT-guided percutaneous lung biopsy of pulmonary lesions using a coaxial automated biopsy device and to determine factors influencing the false negative rate for the diagnosis of malignancy. A prospective study of 605 consecutive biopsies performed in 595 patients was undertaken. The performances for the diagnosis of malignancy, for the specific diagnosis of benignity and the complication rate were calculated. Patients’ characteristics and lesion and procedure variables were included in a logistic regression model and analyzed as potential predictive variables for occurrence of a false-negative diagnosis of malignancy. The sensitivity, specificity, positive predictive value and negative predictive value for a diagnosis of malignancy were 92.2, 99.1, 99.8 and 73.3%, respectively. A specific diagnosis of benignity was obtained in 43 cases (40%) biopsies. The pneumothorax rate was 17.4% (n=105) with 3 (0.5%) requiring drainage. At multivariate analysis, the sole variable significantly associated with a higher rate of false negative diagnosis of malignancy was lesion size equal to or smaller than 10 mm in diameter. Using a coaxial automated device, CT-guided percutaneous biopsy of pulmonary lesions of size equal to or less than 10 mm in diameter provides a high diagnostic yield with an acceptable complication rate.
Literatur
1.
Zurück zum Zitat Westcott JL (1980) Direct percutaneous needle aspiration of localized pulmonary lesions: result in 422 patients. Radiology 137:31–35PubMed Westcott JL (1980) Direct percutaneous needle aspiration of localized pulmonary lesions: result in 422 patients. Radiology 137:31–35PubMed
2.
Zurück zum Zitat Miller DA, Carrasco CH, Katz RL, Cramer FM, Wallace S, Charnsangavej C (1986) Fine needle aspiration biopsy: the role of immediate cytologic assessment. Am J Roentgenol 147:155–158 Miller DA, Carrasco CH, Katz RL, Cramer FM, Wallace S, Charnsangavej C (1986) Fine needle aspiration biopsy: the role of immediate cytologic assessment. Am J Roentgenol 147:155–158
3.
Zurück zum Zitat Austin JH, Cohen MB (1993) Value of having a cytopathologist present during percutaneous fine-needle aspiration biopsy of lung: report of 55 cancer patients and metaanalysis of the literature. Am J Roentgenol 160:175–177 Austin JH, Cohen MB (1993) Value of having a cytopathologist present during percutaneous fine-needle aspiration biopsy of lung: report of 55 cancer patients and metaanalysis of the literature. Am J Roentgenol 160:175–177
4.
Zurück zum Zitat Padhani AR, Scott WW Jr, Cheema M, Kearney D, Erozan YS (1997) The value of immediate cytologic evaluation for needle aspiration lung biopsy. Invest Radiol 32:453–458CrossRefPubMed Padhani AR, Scott WW Jr, Cheema M, Kearney D, Erozan YS (1997) The value of immediate cytologic evaluation for needle aspiration lung biopsy. Invest Radiol 32:453–458CrossRefPubMed
5.
Zurück zum Zitat Lucidarme O, Howarth N, Finet JF, Grenier PA (1998) Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle. Radiology 207:759–765PubMed Lucidarme O, Howarth N, Finet JF, Grenier PA (1998) Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle. Radiology 207:759–765PubMed
6.
Zurück zum Zitat Moulton JS, Moore PT (1993) Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value. Radiology 186:515–522PubMed Moulton JS, Moore PT (1993) Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value. Radiology 186:515–522PubMed
7.
Zurück zum Zitat Arakawa H, Nakajima Y, Kurihara Y, Niimi H, Ishikawa T (1996) CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration. Clin Radiol 51:503–506PubMed Arakawa H, Nakajima Y, Kurihara Y, Niimi H, Ishikawa T (1996) CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration. Clin Radiol 51:503–506PubMed
8.
Zurück zum Zitat Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 198:715–720PubMed Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 198:715–720PubMed
9.
Zurück zum Zitat Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM, Dubrez J (2000) CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol 55:281–287CrossRefPubMed Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM, Dubrez J (2000) CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol 55:281–287CrossRefPubMed
10.
Zurück zum Zitat Hosmer DWLS (1989) Applied logistic regression. Wiley, New York Hosmer DWLS (1989) Applied logistic regression. Wiley, New York
11.
Zurück zum Zitat Berquist TH, Bailey PB, Cortese DA, Miller WE (1980) Transthoracic needle biopsy: accuracy and complications in relation to location and type of lesion. Mayo Clin Proc 55:475–481PubMed Berquist TH, Bailey PB, Cortese DA, Miller WE (1980) Transthoracic needle biopsy: accuracy and complications in relation to location and type of lesion. Mayo Clin Proc 55:475–481PubMed
12.
Zurück zum Zitat Westcott JL, Rao N, Colley DP (1997) Transthoracic needle biopsy of small pulmonary nodules. Radiology 202:97–103PubMed Westcott JL, Rao N, Colley DP (1997) Transthoracic needle biopsy of small pulmonary nodules. Radiology 202:97–103PubMed
13.
Zurück zum Zitat Bocking A, Klose KC, Kyll HJ, Hauptmann S (1995) Cytologic versus histologic evaluation of needle biopsy of the lung, hilum and mediastinum. Sensitivity, specificity and typing accuracy. Acta Cytol 39:463–471PubMed Bocking A, Klose KC, Kyll HJ, Hauptmann S (1995) Cytologic versus histologic evaluation of needle biopsy of the lung, hilum and mediastinum. Sensitivity, specificity and typing accuracy. Acta Cytol 39:463–471PubMed
14.
Zurück zum Zitat Oikonomou A, Matzinger FR, Seely JM, Dennie CJ, Macleod PJ (2003) Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates. Eur Radiol 13:20 Oikonomou A, Matzinger FR, Seely JM, Dennie CJ, Macleod PJ (2003) Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates. Eur Radiol 13:20
15.
Zurück zum Zitat Hahn PF, Eisenberg PJ, Pitman MB, Gazelle GS, Mueller PR (1995) Cytopathologic touch preparations (imprints) from core needle biopsies: accuracy compared with that of fine-needle aspirates. Am J Roentgenol 165:1277–1279 Hahn PF, Eisenberg PJ, Pitman MB, Gazelle GS, Mueller PR (1995) Cytopathologic touch preparations (imprints) from core needle biopsies: accuracy compared with that of fine-needle aspirates. Am J Roentgenol 165:1277–1279
16.
Zurück zum Zitat Yamagami T, Shigeharu L, Takeharu K, Tanaka O, Nishimura M (2003) Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules. Am J Roentgenol 180:811–815 Yamagami T, Shigeharu L, Takeharu K, Tanaka O, Nishimura M (2003) Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules. Am J Roentgenol 180:811–815
17.
Zurück zum Zitat Tsukada H, Satou T, Iwashima A, Souma T (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. Am J Roentgenol 175:239–243 Tsukada H, Satou T, Iwashima A, Souma T (2000) Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. Am J Roentgenol 175:239–243
18.
Zurück zum Zitat Wallace MJ, Krishnamurthy S, Broemeling LD, Gupta S, Ahrar K, Morello FA Jr et al (2002) CT-guided percutaneous fine-needle aspiration biopsy of small (≤1-cm) pulmonary lesions. Radiology 225:823–828PubMed Wallace MJ, Krishnamurthy S, Broemeling LD, Gupta S, Ahrar K, Morello FA Jr et al (2002) CT-guided percutaneous fine-needle aspiration biopsy of small (≤1-cm) pulmonary lesions. Radiology 225:823–828PubMed
19.
Zurück zum Zitat Boiselle PM, Shepard JA, Mark EJ, Szyfelbein WM, Fan CM, Slanetz PJ et al (1997) Routine addition of an automated biopsy device to fine-needle aspiration of the lung: a prospective assessment. Am J Roentgenol 169:661–666 Boiselle PM, Shepard JA, Mark EJ, Szyfelbein WM, Fan CM, Slanetz PJ et al (1997) Routine addition of an automated biopsy device to fine-needle aspiration of the lung: a prospective assessment. Am J Roentgenol 169:661–666
20.
Zurück zum Zitat McLoud TC (1998) Should cutting needles replace needle aspiration of lung lesions? Radiology 207:569–570PubMed McLoud TC (1998) Should cutting needles replace needle aspiration of lung lesions? Radiology 207:569–570PubMed
Metadaten
Titel
Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions
verfasst von
Michel Montaudon
Valerie Latrabe
Antoine Pariente
Olivier Corneloup
Hugues Begueret
François Laurent
Publikationsdatum
01.07.2004
Erschienen in
European Radiology / Ausgabe 7/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2250-3

Weitere Artikel der Ausgabe 7/2004

European Radiology 7/2004 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.