Skip to main content
Erschienen in: European Radiology 1/2005

01.01.2005 | Cardiac

Visualisation of non-invasive coronary bypass imaging: 4-row vs. 16-row multidetector computed tomography

verfasst von: M. Fawad Khan, Christopher Herzog, Kai Landenberger, Adel Maataoui, Sven Martens, Hanns Ackermann, Anton Moritz, Thomas J. Vogl

Erschienen in: European Radiology | Ausgabe 1/2005

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to investigate the image quality of coronary artery bypass graft visualization in 4- and 16-row multidetector CT using multiple imaging reformations. Material and Methods: One hundred sixteen patients underwent CT examination of the heart after receiving CABG. Group A (n=58) received 4-row MDCT; group B (n=58) received 16-row MDCT. Various bypass types such as LITA to LAD and venous grafts to the RCA and RCX were included in the study. A five-point Likert scale was used to grade image quality. Each bypass was reviewed under different imaging reformations: thin slap maximum intensity projection (MIP thin), multiplanar reformation (MPR) and volume rendering technique (VRT). Special attention was paid to the delineation of the distal anastomosis. Interobserver correlation was determined. Results: From 289 bypass grafts examined, 279 (96.54%) were classified as patent and 10 (3.46%) as not patent. Except for the distal anastomosis, 16-row MDCT showed significantly better results for all segments of bypasses. Comparison of reformations within group A and B showed that MIP thin (P<0.05) and VRT (P<0.05) displayed better visualization as compared to MPR. Conclusion: Significantly better imaging of all bypass types is possible using 16-row MDCT as compared to 4-row MDCT. Assessment of the distal anastomosis yields no difference between 4- and 16-row technology.
Literatur
1.
Zurück zum Zitat Bruckenberger E (2001) Bericht der Arbeitsgruppe Krankenhauswesen der Arbeitsgemeinschaft der obersten Landesgesundheitsbehörden der Länder (AOLG). Herzbericht 14:2001 Bruckenberger E (2001) Bericht der Arbeitsgruppe Krankenhauswesen der Arbeitsgemeinschaft der obersten Landesgesundheitsbehörden der Länder (AOLG). Herzbericht 14:2001
2.
Zurück zum Zitat Berger PB, Alderman EL, Nadel A, Schaff HV (1999) Frequency of early occlusion and stenosis in a left internal mammary artery to left anterior descending artery bypass graft after surgery through a median sternotomy on conventional bypass: benchmark for minimally invasive direct coronary artery bypass. Circulation 100:2353–2358PubMed Berger PB, Alderman EL, Nadel A, Schaff HV (1999) Frequency of early occlusion and stenosis in a left internal mammary artery to left anterior descending artery bypass graft after surgery through a median sternotomy on conventional bypass: benchmark for minimally invasive direct coronary artery bypass. Circulation 100:2353–2358PubMed
3.
Zurück zum Zitat Tan ES, van der Meer J, Jan de Kam P et al (1999) Worse clinical outcome but similar graft patency in women versus men one year after coronary artery bypass graft surgery owing to an excess of exposed risk factors in women. CABADAS. Research Group of the Interuniversity Cardiology Institute of The Netherlands. Coronary artery bypass graft occlusion by aspirin, dipyridamole and acenocoumarol/phenoprocoumon study. J Am Coll Cardiol 34:1760–1768CrossRefPubMed Tan ES, van der Meer J, Jan de Kam P et al (1999) Worse clinical outcome but similar graft patency in women versus men one year after coronary artery bypass graft surgery owing to an excess of exposed risk factors in women. CABADAS. Research Group of the Interuniversity Cardiology Institute of The Netherlands. Coronary artery bypass graft occlusion by aspirin, dipyridamole and acenocoumarol/phenoprocoumon study. J Am Coll Cardiol 34:1760–1768CrossRefPubMed
4.
Zurück zum Zitat Serruys PW, Unger F, Sousa JE et al (2001) Comparison of coronary-artery bypass surgery and stenting for the treatment of multivessel disease. N Engl J Med 344:1117–1124CrossRefPubMed Serruys PW, Unger F, Sousa JE et al (2001) Comparison of coronary-artery bypass surgery and stenting for the treatment of multivessel disease. N Engl J Med 344:1117–1124CrossRefPubMed
5.
Zurück zum Zitat Goldman S, Zadina K, Krasnicka B et al (1997) Predictors of graft patency 3 years after coronary artery bypass graft surgery. Department of Veterans Affairs Cooperative Study Group No. 297. J Am Coll Cardiol 29:1563–1568CrossRefPubMed Goldman S, Zadina K, Krasnicka B et al (1997) Predictors of graft patency 3 years after coronary artery bypass graft surgery. Department of Veterans Affairs Cooperative Study Group No. 297. J Am Coll Cardiol 29:1563–1568CrossRefPubMed
6.
Zurück zum Zitat von Smekal A, Lachat M, Wildermuth S, Khan G, Turina M, Marincek B (2000) Proximal anastomoses of aortocoronary bypasses. Evaluation with ECG-triggered single-slice computerized tomography. Radiologe 40:130–135CrossRefPubMed von Smekal A, Lachat M, Wildermuth S, Khan G, Turina M, Marincek B (2000) Proximal anastomoses of aortocoronary bypasses. Evaluation with ECG-triggered single-slice computerized tomography. Radiologe 40:130–135CrossRefPubMed
7.
Zurück zum Zitat Kwok BW, Lim TT (2000) Cortical blindness following coronary angiography. Singapore Med J 41:604–605PubMed Kwok BW, Lim TT (2000) Cortical blindness following coronary angiography. Singapore Med J 41:604–605PubMed
8.
Zurück zum Zitat Silber S, Finsterer S, Krischke I, Lochow P, Muhling H (2003) Noninvasive angiography of coronary bypass grafts with cardio-CT in a cardiology practice. Herz 28:126–135CrossRefPubMed Silber S, Finsterer S, Krischke I, Lochow P, Muhling H (2003) Noninvasive angiography of coronary bypass grafts with cardio-CT in a cardiology practice. Herz 28:126–135CrossRefPubMed
9.
Zurück zum Zitat Marano R, Storto ML, Maddestra N, Bonomo L (2004) Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography. Eur Radiol 14:1353–1362 Marano R, Storto ML, Maddestra N, Bonomo L (2004) Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography. Eur Radiol 14:1353–1362
10.
Zurück zum Zitat Cademartiri F, Mollet N, van der Lugt A et al (2004) Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser. Eur Radiol 14:178–183CrossRefPubMed Cademartiri F, Mollet N, van der Lugt A et al (2004) Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser. Eur Radiol 14:178–183CrossRefPubMed
11.
Zurück zum Zitat Ohnesorge B, Flohr T, Becker C et al (2000) Cardiac imaging with rapid, retrospective ECG synchronized multilevel spiral CT. Radiologe 40:111–117CrossRefPubMed Ohnesorge B, Flohr T, Becker C et al (2000) Cardiac imaging with rapid, retrospective ECG synchronized multilevel spiral CT. Radiologe 40:111–117CrossRefPubMed
12.
Zurück zum Zitat Ohnesorge B, Flohr T, Becker C et al (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571PubMed Ohnesorge B, Flohr T, Becker C et al (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571PubMed
13.
Zurück zum Zitat Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed Flohr T, Ohnesorge B (2001) Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed
14.
15.
Zurück zum Zitat Herzog C, Dogan S, Diebold T et al (2003) Multi-detector row CT versus coronary angiography: preoperative evaluation before totally endoscopic coronary artery bypass grafting. Radiology 229:200–208PubMed Herzog C, Dogan S, Diebold T et al (2003) Multi-detector row CT versus coronary angiography: preoperative evaluation before totally endoscopic coronary artery bypass grafting. Radiology 229:200–208PubMed
16.
Zurück zum Zitat Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463PubMed Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W (2000) In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology 216:457–463PubMed
17.
Zurück zum Zitat Hong C, Becker CR, Huber A et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717PubMed Hong C, Becker CR, Huber A et al (2001) ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology 220:712–717PubMed
18.
Zurück zum Zitat Kopp AF, Ohnesorge B, Flohr T et al (2000) Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 172:429–435CrossRefPubMed Kopp AF, Ohnesorge B, Flohr T et al (2000) Cardiac multidetector-row CT: first clinical results of retrospectively ECG-gated spiral with optimized temporal and spatial resolution. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 172:429–435CrossRefPubMed
19.
Zurück zum Zitat Georg C, Kopp A, Schroder S et al (2001) Optimizing image reconstruction timing for the RR interval in imaging coronary arteries with multi-slice computerized tomography. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:536–541CrossRefPubMed Georg C, Kopp A, Schroder S et al (2001) Optimizing image reconstruction timing for the RR interval in imaging coronary arteries with multi-slice computerized tomography. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 173:536–541CrossRefPubMed
20.
Zurück zum Zitat Rodenwaldt J (2003) Multislice computed tomography of the coronary arteries. Eur Radiol 13:748–757PubMed Rodenwaldt J (2003) Multislice computed tomography of the coronary arteries. Eur Radiol 13:748–757PubMed
21.
Zurück zum Zitat Nikolaou K, Sagmeister S, Knez A et al (2003) Multidetector-row computed tomography of the coronary arteries: predictive value and quantitative assessment of non-calcified vessel-wall changes. Eur Radiol 13:2505–2512CrossRefPubMed Nikolaou K, Sagmeister S, Knez A et al (2003) Multidetector-row computed tomography of the coronary arteries: predictive value and quantitative assessment of non-calcified vessel-wall changes. Eur Radiol 13:2505–2512CrossRefPubMed
22.
Zurück zum Zitat Lu B, Dai RP, Zhuang N, Budoff MJ (2002) Noninvasive assessment of coronary artery bypass graft patency and flow characteristics by electron-beam tomography. J Invasive Cardiol 14:19–24PubMed Lu B, Dai RP, Zhuang N, Budoff MJ (2002) Noninvasive assessment of coronary artery bypass graft patency and flow characteristics by electron-beam tomography. J Invasive Cardiol 14:19–24PubMed
23.
Zurück zum Zitat Pasowicz M, Klimeczek P, Pieniazek P et al (2002) Assessment of stent patency using multi-slice spiral computed tomography: initial experience. Acta Cardiol 57:63–64PubMed Pasowicz M, Klimeczek P, Pieniazek P et al (2002) Assessment of stent patency using multi-slice spiral computed tomography: initial experience. Acta Cardiol 57:63–64PubMed
24.
Zurück zum Zitat Nieman K, Pattynama PM, Rensing BJ, Van Geuns RJ, De Feyter PJ (2003) Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries. Radiology 229:749–756PubMed Nieman K, Pattynama PM, Rensing BJ, Van Geuns RJ, De Feyter PJ (2003) Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries. Radiology 229:749–756PubMed
25.
Zurück zum Zitat Enzweiler CN, Kivelitz DE, Wiese TH et al (2000) Coronary artery bypass grafts: improved electron-beam tomography by prolonging breath holds with preoxygenation. Radiology 217:278–283PubMed Enzweiler CN, Kivelitz DE, Wiese TH et al (2000) Coronary artery bypass grafts: improved electron-beam tomography by prolonging breath holds with preoxygenation. Radiology 217:278–283PubMed
26.
Zurück zum Zitat Knollmann FD, Moller J, Gebert A, Bethge C, Felix R (2004) Assessment of coronary artery stent patency by electron-beam CT. Eur Radiol 14:1341–1347CrossRefPubMed Knollmann FD, Moller J, Gebert A, Bethge C, Felix R (2004) Assessment of coronary artery stent patency by electron-beam CT. Eur Radiol 14:1341–1347CrossRefPubMed
27.
Zurück zum Zitat Achenbach S, Moshage W, Ropers D, Nossen J, Bachmann K (1997) Noninvasive, three-dimensional visualization of coronary artery bypass grafts by electron beam tomography. Am J Cardiol 79:856–861CrossRefPubMed Achenbach S, Moshage W, Ropers D, Nossen J, Bachmann K (1997) Noninvasive, three-dimensional visualization of coronary artery bypass grafts by electron beam tomography. Am J Cardiol 79:856–861CrossRefPubMed
28.
Zurück zum Zitat Ropers D, Ulzheimer S, Wenkel E et al (2001) Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction. Am J Cardiol 88:792–795CrossRefPubMed Ropers D, Ulzheimer S, Wenkel E et al (2001) Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction. Am J Cardiol 88:792–795CrossRefPubMed
29.
Zurück zum Zitat Dewey M, Lembcke A, Enzweiler C, Hamm B, Rogalla P (2004) Isotropic half-millimeter angiography of coronary artery bypass grafts with 16-slice computed tomography. Ann Thorac Surg 77:800–804CrossRefPubMed Dewey M, Lembcke A, Enzweiler C, Hamm B, Rogalla P (2004) Isotropic half-millimeter angiography of coronary artery bypass grafts with 16-slice computed tomography. Ann Thorac Surg 77:800–804CrossRefPubMed
Metadaten
Titel
Visualisation of non-invasive coronary bypass imaging: 4-row vs. 16-row multidetector computed tomography
verfasst von
M. Fawad Khan
Christopher Herzog
Kai Landenberger
Adel Maataoui
Sven Martens
Hanns Ackermann
Anton Moritz
Thomas J. Vogl
Publikationsdatum
01.01.2005
Erschienen in
European Radiology / Ausgabe 1/2005
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2521-z

Weitere Artikel der Ausgabe 1/2005

European Radiology 1/2005 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.