We evaluated the potential for reduction of dose to the female breast in computed tomography (CT) of the thorax by using three different techniques: bismuth shielding, partial CT scanning and tube-current modulation (TCM). Measurements and simulations of dose and image quality were performed for a 64-slice CT system using a semi-anthropomorphic thorax phantom with breasts added. Three-dimensional dose distributions were calculated by Monte Carlo (MC) methods. Noise was determined by measurements and simulations. Bismuth shielding resulted in a dose reduction of about 50% for the breast, noise increased up to 40% and image quality was impaired by artifacts. In partial CT scans, not irradiating the breasts directly, dose to the breasts was reduced typically by 50%. To sustain a constant noise level, an increase of irradiation in the anteroposterior position resulted in a higher dose to the spine. Reduction of dose to the breasts of about 10% was achieved with TCM; distribution of noise was homogeneous and image quality uniform. Reduction of dose to the female breast was achieved by using all adapted CT methods. Bismuth shielding may compromise image quality, increase noise level and introduce streak artifacts. Partial and TCM examinations reduced dose to the breast without influencing image quality.
Literatur
1.
Zurück zum Zitat American Cancer Society (2006) Cancer facts and figures 2006. American Cancer Society, Atlanta American Cancer Society (2006) Cancer facts and figures 2006. American Cancer Society, Atlanta
2.
Zurück zum Zitat Tokunaga M, Land CE, Yamamoto T (1987) Incidence of female breast cancer among atomic bomb survivors, Hiroshima and Nagasaki, 1950–1980. Radiat Res 112:243–272PubMedCrossRef Tokunaga M, Land CE, Yamamoto T (1987) Incidence of female breast cancer among atomic bomb survivors, Hiroshima and Nagasaki, 1950–1980. Radiat Res 112:243–272PubMedCrossRef
3.
Zurück zum Zitat Boice JD, Monson RR (1977) Breast cancer in women after repeated fluoroscopic examinations of the chest. J Natl Cancer Inst 59:823–832PubMed Boice JD, Monson RR (1977) Breast cancer in women after repeated fluoroscopic examinations of the chest. J Natl Cancer Inst 59:823–832PubMed
4.
Zurück zum Zitat Shore RE, Hempelmann LH, Kowaluk E (1977) Breast neoplasms in women treated with x-rays for acute postpartum mastitis. J Natl Cancer Inst 59:813–822PubMed Shore RE, Hempelmann LH, Kowaluk E (1977) Breast neoplasms in women treated with x-rays for acute postpartum mastitis. J Natl Cancer Inst 59:813–822PubMed
5.
Zurück zum Zitat International Commission on Radiological Protection (ICRP) (1991) 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60, Ann ICRP 21(1–3). Pergamon Press Oxford International Commission on Radiological Protection (ICRP) (1991) 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60, Ann ICRP 21(1–3). Pergamon Press Oxford
6.
Zurück zum Zitat International Commission on Radiological Protection (ICRP) (2008) Recommendations of the ICRP. ICRP Publication 103, Ann ICRP 37(2–3). Elsevier, Oxford International Commission on Radiological Protection (ICRP) (2008) Recommendations of the ICRP. ICRP Publication 103, Ann ICRP 37(2–3). Elsevier, Oxford
7.
Zurück zum Zitat Geleijns J, Salvado Artells M, Veldkamp WJ, Lopez Tortosa M, Calzado Cantera A (2006) Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality. Eur Radiol 16:2334–2340PubMedCrossRef Geleijns J, Salvado Artells M, Veldkamp WJ, Lopez Tortosa M, Calzado Cantera A (2006) Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality. Eur Radiol 16:2334–2340PubMedCrossRef
8.
Zurück zum Zitat McLaughlin DJ, Mooney RB (2004) Dose reduction to radiosensitive tissues in CT. Do commercially available shields meet the users’ needs? Clin Radiol 59:446–450PubMedCrossRef McLaughlin DJ, Mooney RB (2004) Dose reduction to radiosensitive tissues in CT. Do commercially available shields meet the users’ needs? Clin Radiol 59:446–450PubMedCrossRef
9.
Zurück zum Zitat Schmidt B, Kalender WA (2002) Zusammenhang zwischen Reduktion der Patientendosis und des Röhrenstom-Zeit-Produktes bei unterschiedlichen Arten der Röhrenstrommodulation bei CT-Untersuchungen. Fortschr Röntgenstr VO52.3 Schmidt B, Kalender WA (2002) Zusammenhang zwischen Reduktion der Patientendosis und des Röhrenstom-Zeit-Produktes bei unterschiedlichen Arten der Röhrenstrommodulation bei CT-Untersuchungen. Fortschr Röntgenstr VO52.3
10.
Zurück zum Zitat Schmidt B. Dosisberechnungen für die Computertomographie (2001) In: Kalender WA (ed) Berichte aus dem Institut für Medizinische Physik. Bd. 7. Shaker, Aachen Schmidt B. Dosisberechnungen für die Computertomographie (2001) In: Kalender WA (ed) Berichte aus dem Institut für Medizinische Physik. Bd. 7. Shaker, Aachen
11.
Zurück zum Zitat Kalender WA, Wolf H, Süß C, Gies M, Greess H, Bautz WA (1999) Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers. Eur Radiol 9:323–328PubMedCrossRef Kalender WA, Wolf H, Süß C, Gies M, Greess H, Bautz WA (1999) Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers. Eur Radiol 9:323–328PubMedCrossRef
12.
Zurück zum Zitat Kalender WA (2005) Computed tomography, 2nd edn. Publicis, Erlangen Kalender WA (2005) Computed tomography, 2nd edn. Publicis, Erlangen
13.
Zurück zum Zitat Greess H, Nömayr A, Wolf H et al (2002) Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE dose). Eur Radiol 12:1571–1576PubMedCrossRef Greess H, Nömayr A, Wolf H et al (2002) Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE dose). Eur Radiol 12:1571–1576PubMedCrossRef
14.
Zurück zum Zitat Kalra MK, Maher MM, Toth TL et al (2004) Strategies for CT radiation dose optimization. Radiology 230:619–628PubMedCrossRef Kalra MK, Maher MM, Toth TL et al (2004) Strategies for CT radiation dose optimization. Radiology 230:619–628PubMedCrossRef
15.
Zurück zum Zitat Graser A, Wintersperger BJ, Suess C, Reiser MF, Becker CR (2006) Dose reduction and image quality in MDCT colonography using tube current modulation. AJR Am J Roentgenol 187:695–701PubMedCrossRef Graser A, Wintersperger BJ, Suess C, Reiser MF, Becker CR (2006) Dose reduction and image quality in MDCT colonography using tube current modulation. AJR Am J Roentgenol 187:695–701PubMedCrossRef
16.
Zurück zum Zitat Mulkens TH, Daineffe S, De Wijngaert R et al (2007) Urinary stone disease: comparison of standard-dose and low-dose with 4D MDCT tube current modulation. AJR Am J Roentgenol 188:553–562PubMedCrossRef Mulkens TH, Daineffe S, De Wijngaert R et al (2007) Urinary stone disease: comparison of standard-dose and low-dose with 4D MDCT tube current modulation. AJR Am J Roentgenol 188:553–562PubMedCrossRef
17.
Zurück zum Zitat Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484–497PubMed Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484–497PubMed
18.
Zurück zum Zitat McCollough CH, Ulzheimer S, Halliburton SS, Shanneik K, White RD, Kalender WA (2007) Coronary artery calcium: a multiinstitutional, multimanufacturer international standard for quantification at cardiac CT. Radiology 243:527–538PubMedCrossRef McCollough CH, Ulzheimer S, Halliburton SS, Shanneik K, White RD, Kalender WA (2007) Coronary artery calcium: a multiinstitutional, multimanufacturer international standard for quantification at cardiac CT. Radiology 243:527–538PubMedCrossRef
19.
Zurück zum Zitat Kalender WA, Rienmüller R, Behr J, Seißler W, Fichte H, Welke M (1990) Quantitative CT of the lung with spirometrically controlled respiratory status and automated evaluation procedures. In: Fuchs W (ed) Advances in CT. Springer, Heidelberg, pp 85–93 Kalender WA, Rienmüller R, Behr J, Seißler W, Fichte H, Welke M (1990) Quantitative CT of the lung with spirometrically controlled respiratory status and automated evaluation procedures. In: Fuchs W (ed) Advances in CT. Springer, Heidelberg, pp 85–93
20.
Zurück zum Zitat Deak P, van Straten M, Shrimpton PC, Zankl M, Kalender WA (2007) Validation of a Monte Carlo tool for patient-specific dose simulations in X-ray computed tomography. Eur Radiol (in press) Deak P, van Straten M, Shrimpton PC, Zankl M, Kalender WA (2007) Validation of a Monte Carlo tool for patient-specific dose simulations in X-ray computed tomography. Eur Radiol (in press)
21.
Zurück zum Zitat Schmidt B, Kalender WA (2002) A fast voxel-based Monte Carlo method for scanner- and patient- specific dose calculations in computed tomography. Physica Medica XVIII(2) Schmidt B, Kalender WA (2002) A fast voxel-based Monte Carlo method for scanner- and patient- specific dose calculations in computed tomography. Physica Medica XVIII(2)
22.
Zurück zum Zitat Mulkens TH, Bellinck P, Baeyaert M et al (2005) Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 237:213–223PubMedCrossRef Mulkens TH, Bellinck P, Baeyaert M et al (2005) Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 237:213–223PubMedCrossRef
Metadaten
Titel
Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations
verfasst von
Sabrina V. Vollmar
Willi A. Kalender
Publikationsdatum
01.08.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 8/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-0934-9

Weitere Artikel der Ausgabe 8/2008

European Radiology 8/2008 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.