Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 11/2020

03.08.2020 | Knee Arthroplasty

Correlation of tibial component size and rotation with outcomes after total knee arthroplasty

verfasst von: Antonio Klasan, Joshua G. Twiggs, Brett A. Fritsch, Brad P. Miles, Thomas J. Heyse, Michael Solomon, David A. Parker

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 11/2020

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Tibial component design and positioning contribute more to patient satisfaction than previously realized. A surgeon needs to decide on the size and rotation, bearing in mind that coverage should be as high as possible, whilst malrotation and overhang should be avoided. No study investigates the impact of each of these components on clinical outcomes in a single cohort.

Materials and methods

This is a retrospective analysis of 1-year postoperative outcomes measured with the Knee Injury and Osteoarthritis Outcome (KOOS) Score, as well as a previously validated rotational CT protocol. Coverage, rotation from Insall’s axis, and overhang of an asymmetric tibial baseplate were measured, and positive and negative correlations to clinical outcomes were calculated.

Results

A total of 499 knees were analyzed. Patient average age was 68.4 years. Rotation within 7° internal and 5° external from Insall’s axis was a “safe zone”. Mean coverage was 76%. A total of 429 knees (94%) had a coverage of at least 70% and 102 knees (22%) greater than 80%. Overhang was detected in 23% of the cohort. Increased coverage was correlated to increased KOOS score and overhang correlated with a decreased KOOS score (p = 0.008).

Conclusions

This study demonstrates the individual role of three aspects of tibial component implantation properties in postoperative pain and short-term functional outcomes. Upsizing to the point of overhang with rotational tolerance of 7° internal and 3° external to Insall’s axis demonstrates best patient reported outcomes. Overhang decreases the clinical outcome by the same margin as loss of 16% of coverage.
Literatur
11.
Zurück zum Zitat Incavo SJ, Ronchetti PJ, Howe JG, Tranowski JP (1994) Tibial plateau coverage in total knee arthroplasty. Clin Orthop Relat Res 299:81–85 Incavo SJ, Ronchetti PJ, Howe JG, Tranowski JP (1994) Tibial plateau coverage in total knee arthroplasty. Clin Orthop Relat Res 299:81–85
27.
Zurück zum Zitat Baldini A, Indelli PF, Luca DEL et al (2013) Rotational alignment of the tibial component in total knee arthroplasty: the anterior tibial cortex is a reliable landmark. Joints 1:155–160CrossRef Baldini A, Indelli PF, Luca DEL et al (2013) Rotational alignment of the tibial component in total knee arthroplasty: the anterior tibial cortex is a reliable landmark. Joints 1:155–160CrossRef
29.
Zurück zum Zitat Akagi M, Mori S, Nishimura S et al (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172–176CrossRef Akagi M, Mori S, Nishimura S et al (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172–176CrossRef
32.
Zurück zum Zitat Liau JJ, Cheng CK, Huang CH, Lo WH (2002) The effect of malalignment on stresses in polyethylene component of total knee prostheses–a finite element analysis. Clin Biomech (Bristol, Avon) 17:140–146CrossRef Liau JJ, Cheng CK, Huang CH, Lo WH (2002) The effect of malalignment on stresses in polyethylene component of total knee prostheses–a finite element analysis. Clin Biomech (Bristol, Avon) 17:140–146CrossRef
Metadaten
Titel
Correlation of tibial component size and rotation with outcomes after total knee arthroplasty
verfasst von
Antonio Klasan
Joshua G. Twiggs
Brett A. Fritsch
Brad P. Miles
Thomas J. Heyse
Michael Solomon
David A. Parker
Publikationsdatum
03.08.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 11/2020
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-020-03550-z

Weitere Artikel der Ausgabe 11/2020

Archives of Orthopaedic and Trauma Surgery 11/2020 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.