Are computer numerical control (CNC)-manufactured patient-specific metal templates available for posterior thoracic pedicle screw insertion? Feasibility and accuracy evaluation

verfasst von: Xiangxue Kong, Lei Tang, Qiang Ye, Wenhua Huang, Jianyi Li

Erschienen in: European Spine Journal | Ausgabe 11/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Accurate and safe posterior thoracic pedicle insertion (PTPI) remains a challenge. Patient-specific drill templates (PDTs) created by rapid prototyping (RP) can assist in posterior thoracic pedicle insertion, but pose biocompatibility risks. The aims of this study were to develop alternative PDTs with computer numerical control (CNC) and assess their feasibility and accuracy in assisting PTPI.

Methods

Preoperative CT images of 31 cadaveric thoracic vertebras were obtained and then the optimal pedicle screw trajectories were planned. The PDTs with optimal screw trajectories were randomly assigned to be designed and manufactured by CNC or RP in each vertebra. With the guide of the CNC- or RP-manufactured PDTs, the appropriate screws were inserted into the pedicles. Postoperative CT scans were performed to analyze any deviations at entry point and midpoint of the pedicles.

Results

The CNC group was found to be significant manufacture-time-shortening, and cost-decreasing, when compared with the RP group (P < 0.01). The PDTs fitted the vertebral laminates well while all screws were being inserted into the pedicles. There were no significant differences in absolute deviations at entry point and midpoint of the pedicle on either axial or sagittal planes (P > 0.05). The screw positions were grade 0 in 90.3% and grade 1 in 9.7% of the cases in the CNC group and grade 0 in 93.5% and grade 1 in 6.5% of the cases in the RP group (P = 0.641).

Conclusion

CNC-manufactured PDTs are viable for assisting in PTPI with good feasibility and accuracy.
Literatur
3.
4.
Zurück zum Zitat Deng Y, Zhou Y, Lu G, Wang B, Li J, Kang Y, Lu C, Liu W, Ma Z (2009) Complication of thoracic pedicle screw fixation in spinal deformities. Zhong Nan Da Xue Xue Bao Yi Xue Ban 34:820–824PubMed Deng Y, Zhou Y, Lu G, Wang B, Li J, Kang Y, Lu C, Liu W, Ma Z (2009) Complication of thoracic pedicle screw fixation in spinal deformities. Zhong Nan Da Xue Xue Bao Yi Xue Ban 34:820–824PubMed
6.
Zurück zum Zitat Lekovic GP, Potts EA, Karahalios DG, Hall G (2007) A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg Spine 7:393–398. doi:10.3171/SPI-07/10/3933 CrossRefPubMed Lekovic GP, Potts EA, Karahalios DG, Hall G (2007) A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg Spine 7:393–398. doi:10.​3171/​SPI-07/​10/​3933 CrossRefPubMed
8.
Zurück zum Zitat Gang C, Haibo L, Fancai L, Weishan C, Qixin C (2012) Learning curve of thoracic pedicle screw placement using the free-hand technique in scoliosis: how many screws needed for an apprentice? Eur Spine J 21:1151–1156. doi:10.1007/s00586-011-2065-2 CrossRefPubMed Gang C, Haibo L, Fancai L, Weishan C, Qixin C (2012) Learning curve of thoracic pedicle screw placement using the free-hand technique in scoliosis: how many screws needed for an apprentice? Eur Spine J 21:1151–1156. doi:10.​1007/​s00586-011-2065-2 CrossRefPubMed
9.
Zurück zum Zitat Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine (Phila Pa 1976) 29:333–342CrossRef Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine (Phila Pa 1976) 29:333–342CrossRef
10.
Zurück zum Zitat Li J, Zhao H, Xie H, Yu L, Wei J, Zong M, Chen F, Zhu Z, Zhang N, Cao X (2014) A new free-hand pedicle screw placement technique with reference to the supraspinal ligament. J Biomed Res 28:64–70. doi:10.7555/JBR.27.20130051 PubMed Li J, Zhao H, Xie H, Yu L, Wei J, Zong M, Chen F, Zhu Z, Zhang N, Cao X (2014) A new free-hand pedicle screw placement technique with reference to the supraspinal ligament. J Biomed Res 28:64–70. doi:10.​7555/​JBR.​27.​20130051 PubMed
11.
Zurück zum Zitat Braga BP, de Morais JV, Vilela MD (2010) Free-hand placement of high thoracic pedicle screws with the aid of fluoroscopy: evaluation of positioning by CT scans in a four-year consecutive series. Arq Neuropsiquiatr 68:390–395CrossRefPubMed Braga BP, de Morais JV, Vilela MD (2010) Free-hand placement of high thoracic pedicle screws with the aid of fluoroscopy: evaluation of positioning by CT scans in a four-year consecutive series. Arq Neuropsiquiatr 68:390–395CrossRefPubMed
12.
13.
Zurück zum Zitat Austin MS, Vaccaro AR, Brislin B, Nachwalter R, Hilibrand AS, Albert TJ (2002) Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine (Phila Pa 1976) 27:2503–2508. doi:10.1097/01.BRS.0000031274.34509.1E CrossRef Austin MS, Vaccaro AR, Brislin B, Nachwalter R, Hilibrand AS, Albert TJ (2002) Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Spine (Phila Pa 1976) 27:2503–2508. doi:10.​1097/​01.​BRS.​0000031274.​34509.​1E CrossRef
14.
Zurück zum Zitat Lee CY, Wu MH, Li YY, Cheng CC, Hsu CH, Huang TJ, Hsu RW (2015) Intraoperative computed tomography navigation for transpedicular screw fixation to treat unstable thoracic and lumbar spine fractures: clinical analysis of a case series (CARE-compliant). Medicine (Baltimore) 94:e757. doi:10.1097/MD.0000000000000757 CrossRef Lee CY, Wu MH, Li YY, Cheng CC, Hsu CH, Huang TJ, Hsu RW (2015) Intraoperative computed tomography navigation for transpedicular screw fixation to treat unstable thoracic and lumbar spine fractures: clinical analysis of a case series (CARE-compliant). Medicine (Baltimore) 94:e757. doi:10.​1097/​MD.​0000000000000757​ CrossRef
16.
Zurück zum Zitat Larson AN, Santos ER, Polly DJ, Ledonio CG, Sembrano JN, Mielke CH, Guidera KJ (2012) Pediatric pedicle screw placement using intraoperative computed tomography and 3-dimensional image-guided navigation. Spine (Phila Pa 1976) 37:E188–E194. doi:10.1097/BRS.0b013e31822a2e0a CrossRef Larson AN, Santos ER, Polly DJ, Ledonio CG, Sembrano JN, Mielke CH, Guidera KJ (2012) Pediatric pedicle screw placement using intraoperative computed tomography and 3-dimensional image-guided navigation. Spine (Phila Pa 1976) 37:E188–E194. doi:10.​1097/​BRS.​0b013e31822a2e0a​ CrossRef
17.
Zurück zum Zitat Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 25:2637–2645CrossRef Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M (2000) Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 25:2637–2645CrossRef
18.
Zurück zum Zitat Nyheim T, Staxrud LE, Jorgensen JJ, Jensen K, Olerud HM, Sandbaek G (2017) Radiation exposure in patients treated with endovascular aneurysm repair: what is the risk of cancer, and can we justify treating younger patients? Acta Radiol 58:323–330. doi:10.1177/0284185116651002 CrossRefPubMed Nyheim T, Staxrud LE, Jorgensen JJ, Jensen K, Olerud HM, Sandbaek G (2017) Radiation exposure in patients treated with endovascular aneurysm repair: what is the risk of cancer, and can we justify treating younger patients? Acta Radiol 58:323–330. doi:10.​1177/​0284185116651002​ CrossRefPubMed
20.
Zurück zum Zitat Allam Y, Silbermann J, Riese F, Greiner-Perth R (2013) Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques. Eur Spine J 22:648–653. doi:10.1007/s00586-012-2505-7 CrossRefPubMed Allam Y, Silbermann J, Riese F, Greiner-Perth R (2013) Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques. Eur Spine J 22:648–653. doi:10.​1007/​s00586-012-2505-7 CrossRefPubMed
21.
25.
Zurück zum Zitat Farshad M, Betz M, Farshad-Amacker NA, Moser M (2017) Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study. Eur Spine J 26:738–749. doi:10.1007/s00586-016-4728-5 CrossRefPubMed Farshad M, Betz M, Farshad-Amacker NA, Moser M (2017) Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study. Eur Spine J 26:738–749. doi:10.​1007/​s00586-016-4728-5 CrossRefPubMed
26.
Zurück zum Zitat Lu S, Xu YQ, Zhang YZ, Li YB, Xie L, Shi JH, Guo H, Chen GP, Chen YB (2009) A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study. Int J Med Robot 5:184–191. doi:10.1002/rcs.249 CrossRefPubMed Lu S, Xu YQ, Zhang YZ, Li YB, Xie L, Shi JH, Guo H, Chen GP, Chen YB (2009) A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study. Int J Med Robot 5:184–191. doi:10.​1002/​rcs.​249 CrossRefPubMed
27.
Zurück zum Zitat Ma T, Xu YQ, Cheng YB, Jiang MY, Xu XM, Xie L, Lu S (2012) A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study. Arch Orthop Trauma Surg 132:65–72. doi:10.1007/s00402-011-1383-5 CrossRefPubMed Ma T, Xu YQ, Cheng YB, Jiang MY, Xu XM, Xie L, Lu S (2012) A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study. Arch Orthop Trauma Surg 132:65–72. doi:10.​1007/​s00402-011-1383-5 CrossRefPubMed
29.
Zurück zum Zitat Putzier M, Strube P, Cecchinato R, Lamartina C, Hoff EK (2017) A new navigational tool for pedicle screw placement in patients with severe scoliosis a pilot study to prove feasibility, accuracy, and identify operative challenges. Clin Spine Surg 30:E430–E439. doi:10.1097/BSD.0000000000000220 PubMed Putzier M, Strube P, Cecchinato R, Lamartina C, Hoff EK (2017) A new navigational tool for pedicle screw placement in patients with severe scoliosis a pilot study to prove feasibility, accuracy, and identify operative challenges. Clin Spine Surg 30:E430–E439. doi:10.​1097/​BSD.​0000000000000220​ PubMed
30.
Zurück zum Zitat Takemoto M, Fujibayashi S, Ota E, Otsuki B, Kimura H, Sakamoto T, Kawai T, Futami T, Sasaki K, Matsushita T, Nakamura T, Neo M, Matsuda S (2015) Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area. Eur Spine J. doi:10.1007/s00586-015-3908-z Takemoto M, Fujibayashi S, Ota E, Otsuki B, Kimura H, Sakamoto T, Kawai T, Futami T, Sasaki K, Matsushita T, Nakamura T, Neo M, Matsuda S (2015) Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area. Eur Spine J. doi:10.​1007/​s00586-015-3908-z
31.
33.
Zurück zum Zitat Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine (Phila Pa 1976) 25:606–614CrossRef Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine (Phila Pa 1976) 25:606–614CrossRef
34.
Zurück zum Zitat Samdani AF, Ranade A, Sciubba DM, Cahill PJ, Antonacci MD, Clements DH, Betz RR (2010) Accuracy of free-hand placement of thoracic pedicle screws in adolescent idiopathic scoliosis: how much of a difference does surgeon experience make? Eur Spine J 19:91–95. doi:10.1007/s00586-009-1183-6 CrossRefPubMed Samdani AF, Ranade A, Sciubba DM, Cahill PJ, Antonacci MD, Clements DH, Betz RR (2010) Accuracy of free-hand placement of thoracic pedicle screws in adolescent idiopathic scoliosis: how much of a difference does surgeon experience make? Eur Spine J 19:91–95. doi:10.​1007/​s00586-009-1183-6 CrossRefPubMed
35.
36.
Zurück zum Zitat Wu ZX, Huang LY, Sang HX, Ma ZS, Wan SY, Cui G, Lei W (2011) Accuracy and safety assessment of pedicle screw placement using the rapid prototyping technique in severe congenital scoliosis. J Spinal Disord Tech 24:444–450. doi:10.1097/BSD.0b013e318201be2a CrossRefPubMed Wu ZX, Huang LY, Sang HX, Ma ZS, Wan SY, Cui G, Lei W (2011) Accuracy and safety assessment of pedicle screw placement using the rapid prototyping technique in severe congenital scoliosis. J Spinal Disord Tech 24:444–450. doi:10.​1097/​BSD.​0b013e318201be2a​ CrossRefPubMed
37.
Zurück zum Zitat Merc M, Drstvensek I, Vogrin M, Brajlih T, Recnik G (2013) A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine. Arch Orthop Trauma Surg. doi:10.1007/s00402-013-1755-0 PubMed Merc M, Drstvensek I, Vogrin M, Brajlih T, Recnik G (2013) A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine. Arch Orthop Trauma Surg. doi:10.​1007/​s00402-013-1755-0 PubMed
38.
Metadaten
Titel
Are computer numerical control (CNC)-manufactured patient-specific metal templates available for posterior thoracic pedicle screw insertion? Feasibility and accuracy evaluation
verfasst von
Xiangxue Kong
Lei Tang
Qiang Ye
Wenhua Huang
Jianyi Li
Publikationsdatum
17.07.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 11/2017
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-017-5215-3

Weitere Artikel der Ausgabe 11/2017

European Spine Journal 11/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.