Skip to main content
Erschienen in: Clinical Oral Investigations 4/2017

09.06.2016 | Original Article

Randomized trial investigating zirconia electroplated telescopic retainers: quality of life outcomes

verfasst von: Franz Sebastian Schwindling, Ulrich Karl Deisenhofer, Anne-Christiane Séché, Franziska Lehmann, Peter Rammelsberg, Thomas Stober

Erschienen in: Clinical Oral Investigations | Ausgabe 4/2017

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The study aims to evaluate the effect of electroplated telescopic removable dental prostheses (E-RDPs) with zirconia primary crowns on oral-health-related quality of life (OHRQoL).

Materials and methods

For E-RDPs, electroplating is used to produce precisely fitting gold copings on telescopic primary crowns. These copings are bonded intra-orally to the denture framework. Fifty-six participants in need of 60 removable restorations were randomly allocated one of two materials for the primary crowns: cobalt–chromium alloy or zirconia. OHRQoL was assessed by use of the 49-item Oral Health Impact Profile (OHIP-49) and by additional patient self-rating at baseline before treatment, and after 6 and 12 months. Statistical analysis was performed by use of one- and two-sample t-tests and analysis of covariance.

Results

Mean OHIP sum score at baseline was 53.4 (SD 37.4, 95 % CI 41.3–62). At follow-ups, it decreased significantly (after 6 months: mean 20, SD 26, 95 % CI 13–27.1; after 12 months: mean 16.4, SD 17.9, 95 % CI 11.6–21.2). The mean reduction in OHIP sum score after 12 months was 25 (SD 31.2, 95 % CI 13.1–36.9) for cobalt–chromium alloy and 44.4 (SD 32.3, 95 % CI 31.1–57.8) for zirconia. However, no statistically significant difference of the two materials on OHIP change or patient self-rating was detected.

Conclusions

Although OHRQoL was improved by using both cobalt–chromium alloy and zirconia primary crowns for E-RDPs, post-treatment differences between the groups were not statistically significant.

Clinical relevance

Zirconia E-RDPs enhance OHRQoL. However, zirconia primary crowns do not outperform cobalt–chromium alloy crowns regarding patient satisfaction—despite their tooth-like color.
Literatur
2.
Zurück zum Zitat Isaacson GO (1969) Telescope crown retainers for removable partial dentures. J Prosthet Dent 22:436–448CrossRefPubMed Isaacson GO (1969) Telescope crown retainers for removable partial dentures. J Prosthet Dent 22:436–448CrossRefPubMed
3.
6.
Zurück zum Zitat Sahin S, Cehreli MC (2001) The significance of passive framework fit in implant prosthodontics: current status. Implant Dent 10:85–92CrossRefPubMed Sahin S, Cehreli MC (2001) The significance of passive framework fit in implant prosthodontics: current status. Implant Dent 10:85–92CrossRefPubMed
7.
Zurück zum Zitat Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:320–336CrossRefPubMed Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:320–336CrossRefPubMed
9.
Zurück zum Zitat Stober T, Bermejo JL, Beck-Mussoter J, Seche AC, Lehmann F, Koob J, Rammelsberg P (2012) Clinical performance of conical and electroplated telescopic double crown-retained partial dentures: a randomized clinical study. Int J Prosthodont 25:209–216PubMed Stober T, Bermejo JL, Beck-Mussoter J, Seche AC, Lehmann F, Koob J, Rammelsberg P (2012) Clinical performance of conical and electroplated telescopic double crown-retained partial dentures: a randomized clinical study. Int J Prosthodont 25:209–216PubMed
10.
Zurück zum Zitat Zafiropoulos GG, Rebbe J, Thielen U, Deli G, Beaumont C, Hoffmann O (2010) Zirconia removable telescopic dentures retained on teeth or implants for maxilla rehabilitation. Three-year observation of three cases. J Oral Implantol 36:455–465. doi:10.1563/AAID-JOI-D-09-00065 CrossRefPubMed Zafiropoulos GG, Rebbe J, Thielen U, Deli G, Beaumont C, Hoffmann O (2010) Zirconia removable telescopic dentures retained on teeth or implants for maxilla rehabilitation. Three-year observation of three cases. J Oral Implantol 36:455–465. doi:10.​1563/​AAID-JOI-D-09-00065 CrossRefPubMed
12.
Zurück zum Zitat John MT, Patrick DL, Slade GD (2002) The German version of the Oral Health Impact Profile—translation and psychometric properties. Eur J Oral Sci 110:425–433CrossRefPubMed John MT, Patrick DL, Slade GD (2002) The German version of the Oral Health Impact Profile—translation and psychometric properties. Eur J Oral Sci 110:425–433CrossRefPubMed
15.
Zurück zum Zitat Manicone PF, Rossi Iommetti P, Raffaelli L, Paolantonio M, Rossi G, Berardi D, Perfetti G (2007) Biological considerations on the use of zirconia for dental devices. Int J Immunopathol Pharmacol 20:9–12PubMed Manicone PF, Rossi Iommetti P, Raffaelli L, Paolantonio M, Rossi G, Berardi D, Perfetti G (2007) Biological considerations on the use of zirconia for dental devices. Int J Immunopathol Pharmacol 20:9–12PubMed
16.
Zurück zum Zitat Bremer F, Grade S, Kohorst P, Stiesch M (2011) In vivo biofilm formation on different dental ceramics. Quintessence Int 42:565–574PubMed Bremer F, Grade S, Kohorst P, Stiesch M (2011) In vivo biofilm formation on different dental ceramics. Quintessence Int 42:565–574PubMed
17.
Zurück zum Zitat Minagi S, Natsuaki N, Nishigawa G, Sato T (1999) New telescopic crown design for removable partial dentures. J Prosthet Dent 81:684–688CrossRefPubMed Minagi S, Natsuaki N, Nishigawa G, Sato T (1999) New telescopic crown design for removable partial dentures. J Prosthet Dent 81:684–688CrossRefPubMed
19.
Zurück zum Zitat Bayer S, Kraus D, Keilig L, Gölz L, Stark H, Enkling N (2012) Changes in retention force with electroplated copings on conical crowns: a comparison of gold and zirconia primary crowns. Int J Oral Maxillofac Implants 27:577–585PubMed Bayer S, Kraus D, Keilig L, Gölz L, Stark H, Enkling N (2012) Changes in retention force with electroplated copings on conical crowns: a comparison of gold and zirconia primary crowns. Int J Oral Maxillofac Implants 27:577–585PubMed
20.
Zurück zum Zitat Turp I, Bozdag E, Sunbuloglu E, Kahruman C, Yusufoglu I, Bayraktar G (2014) Retention and surface changes of zirconia primary crowns with secondary crowns of different materials. Clin Oral Investig. doi:10.1007/s00784-013-1183-0 PubMed Turp I, Bozdag E, Sunbuloglu E, Kahruman C, Yusufoglu I, Bayraktar G (2014) Retention and surface changes of zirconia primary crowns with secondary crowns of different materials. Clin Oral Investig. doi:10.​1007/​s00784-013-1183-0 PubMed
22.
Zurück zum Zitat Montero J, Castillo-Oyague R, Lynch CD, Albaladejo A, Castano A (2013) Self-perceived changes in oral health-related quality of life after receiving different types of conventional prosthetic treatments: a cohort follow-up study. J Dent 41:493–503. doi:10.1016/j.jdent.2013.01.006 CrossRefPubMed Montero J, Castillo-Oyague R, Lynch CD, Albaladejo A, Castano A (2013) Self-perceived changes in oral health-related quality of life after receiving different types of conventional prosthetic treatments: a cohort follow-up study. J Dent 41:493–503. doi:10.​1016/​j.​jdent.​2013.​01.​006 CrossRefPubMed
23.
Zurück zum Zitat Wolfart S, Moll D, Hilgers RD, Wolfart M, Kern M (2013) Implant placement under existing removable dental prostheses and its effect on oral health-related quality of life. Clin Oral Implants Res 24:1354–1359. doi:10.1111/clr.12030 CrossRefPubMed Wolfart S, Moll D, Hilgers RD, Wolfart M, Kern M (2013) Implant placement under existing removable dental prostheses and its effect on oral health-related quality of life. Clin Oral Implants Res 24:1354–1359. doi:10.​1111/​clr.​12030 CrossRefPubMed
26.
Zurück zum Zitat Hassel AJ, Rolko C, Grossmann AC, Ohlmann B, Rammelsberg P (2007) Correlations between self-ratings of denture function and oral health-related quality of life in different age groups. Int J Prosthodont 20:242–244PubMed Hassel AJ, Rolko C, Grossmann AC, Ohlmann B, Rammelsberg P (2007) Correlations between self-ratings of denture function and oral health-related quality of life in different age groups. Int J Prosthodont 20:242–244PubMed
29.
Zurück zum Zitat Swelem AA, Gurevich KG, Fabrikant EG, Hassan MH, Aqou S (2014) Oral health-related quality of life in partially edentulous patients treated with removable, fixed, fixed-removable, and implant-supported prostheses. Int J Prosthodont 27:338–347. doi:10.11607/ijp.3692 CrossRefPubMed Swelem AA, Gurevich KG, Fabrikant EG, Hassan MH, Aqou S (2014) Oral health-related quality of life in partially edentulous patients treated with removable, fixed, fixed-removable, and implant-supported prostheses. Int J Prosthodont 27:338–347. doi:10.​11607/​ijp.​3692 CrossRefPubMed
30.
Zurück zum Zitat Grossmann AC, Hassel AJ, Schilling O, Lehmann F, Koob A, Rammelsberg P (2007) Treatment with double crown-retained removable partial dentures and oral health-related quality of life in middle- and high-aged patients. Int J Prosthodont 20:576–578PubMed Grossmann AC, Hassel AJ, Schilling O, Lehmann F, Koob A, Rammelsberg P (2007) Treatment with double crown-retained removable partial dentures and oral health-related quality of life in middle- and high-aged patients. Int J Prosthodont 20:576–578PubMed
31.
Zurück zum Zitat Inukai M, Baba K, John MT, Igarashi Y (2008) Does removable partial denture quality affect individuals’ oral health? J Dent Res 87:736–739CrossRefPubMed Inukai M, Baba K, John MT, Igarashi Y (2008) Does removable partial denture quality affect individuals’ oral health? J Dent Res 87:736–739CrossRefPubMed
Metadaten
Titel
Randomized trial investigating zirconia electroplated telescopic retainers: quality of life outcomes
verfasst von
Franz Sebastian Schwindling
Ulrich Karl Deisenhofer
Anne-Christiane Séché
Franziska Lehmann
Peter Rammelsberg
Thomas Stober
Publikationsdatum
09.06.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 4/2017
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-016-1869-1

Weitere Artikel der Ausgabe 4/2017

Clinical Oral Investigations 4/2017 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.