Skip to main content
Erschienen in: Odontology 1/2017

15.04.2016 | Original Article

Fracture resistance of three-unit zirconia fixed partial denture with modified framework

verfasst von: Arthur Partiyan, Essam Osman, Mohammad M. Rayyan, Moustafa Aboushelib, Ahmed Ibrahim, Ryo Jimbo

Erschienen in: Odontology | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Obtaining ideal prosthetic framework design is at times hindered by anatomical limitations in the posterior region that might increase the risk for zirconia restoration fracture. Modification such as increasing the bulk thickness especially in the connector region could result in strengthening the zirconia framework. Three-unit zirconia fixed partial dentures replacing mandibular molars were fabricated using the following two techniques: CAD/CAM technology and manual copy milling. Modified framework with unveneered full thickness connectors were designed and fabricated with the aforementioned methods. Conventional frameworks (0.5 mm thick with rounded 3 mm connectors) served as control (N = 20). After cementation on epoxy dies, the frameworks were loaded to fracture in a universal testing machine. Fractured surfaces were prepared for examination using scanning electron microscopy. Statistical analysis revealed significant differences in fracture resistance between conventional and modified framework design for both fabrication techniques tested. SEM examination indicated that critical crack originated at the tensile surface of the connectors for conventional frameworks. The critical crack for modified frameworks occurred on the axial wall of the abutments. The modification of the zirconia framework design presented significant improvement of the fracture resistance compared to the conventional design.
Literatur
1.
Zurück zum Zitat Zembic A, Sailer I, Jung RE, Hämmerle CHF. Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results. Clin Oral Implants Res. 2009;20:802–8.CrossRefPubMed Zembic A, Sailer I, Jung RE, Hämmerle CHF. Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results. Clin Oral Implants Res. 2009;20:802–8.CrossRefPubMed
2.
Zurück zum Zitat Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont. 2007;20:383–8.PubMed Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont. 2007;20:383–8.PubMed
3.
Zurück zum Zitat Moldovan O, Luthardt RG, Corcodel N, Rudolph H. Three-dimensional fit of CAD/CAM-made zirconia copings. Dent Mater. 2011;27:1273–8.CrossRefPubMed Moldovan O, Luthardt RG, Corcodel N, Rudolph H. Three-dimensional fit of CAD/CAM-made zirconia copings. Dent Mater. 2011;27:1273–8.CrossRefPubMed
4.
Zurück zum Zitat Beuer F, Naumann M, Gernet W, Sorensen JA. Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Invest. 2009;13:343–9.CrossRef Beuer F, Naumann M, Gernet W, Sorensen JA. Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Invest. 2009;13:343–9.CrossRef
5.
Zurück zum Zitat Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: a systematic review. J Oral Rehabil. 2010;37:641–52.PubMed Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: a systematic review. J Oral Rehabil. 2010;37:641–52.PubMed
6.
Zurück zum Zitat Manicone PF, Iommetti PR, Raffaelli L. An overview of zirconia ceramics: basic properties and clinical applications. J Dent. 2007;35:819–26.CrossRefPubMed Manicone PF, Iommetti PR, Raffaelli L. An overview of zirconia ceramics: basic properties and clinical applications. J Dent. 2007;35:819–26.CrossRefPubMed
7.
Zurück zum Zitat Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont. 2008;21:217–22.PubMed Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont. 2008;21:217–22.PubMed
8.
Zurück zum Zitat Lohbauer U, Amberger G, Quinn GD, Scherrer SS. Fractographic analysis of a dental zirconia framework: a case study on design issues. J Mech Behav Biomed Mater. 2010;3:623–9.CrossRefPubMedPubMedCentral Lohbauer U, Amberger G, Quinn GD, Scherrer SS. Fractographic analysis of a dental zirconia framework: a case study on design issues. J Mech Behav Biomed Mater. 2010;3:623–9.CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Motta AB, Pereira LC, Cunha ARCCd. All-ceramic and porcelain-fused-to-metal fixed partial dentures: a comparative study by 2D finite element analyses. J Appl Oral Sci. 2007;15:399–405.CrossRefPubMedPubMedCentral Motta AB, Pereira LC, Cunha ARCCd. All-ceramic and porcelain-fused-to-metal fixed partial dentures: a comparative study by 2D finite element analyses. J Appl Oral Sci. 2007;15:399–405.CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Mahmood DJ, Linderoth EH, Von Steyern PV, Wennerberg A. Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history. Swed Dent J. 2013;37:179–87.PubMed Mahmood DJ, Linderoth EH, Von Steyern PV, Wennerberg A. Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history. Swed Dent J. 2013;37:179–87.PubMed
11.
Zurück zum Zitat Oh WS, Anusavice KJ. Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures. J Prosthet Dent. 2002;87:536–42.CrossRefPubMed Oh WS, Anusavice KJ. Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures. J Prosthet Dent. 2002;87:536–42.CrossRefPubMed
12.
13.
Zurück zum Zitat Mainjot AK, Schajer GS, Vanheusden AJ, Sadoun MJ. Influence of zirconia framework thickness on residual stress profile in veneering ceramic: measurement by hole-drilling. Dent Mater. 2012;28:378–84.CrossRefPubMed Mainjot AK, Schajer GS, Vanheusden AJ, Sadoun MJ. Influence of zirconia framework thickness on residual stress profile in veneering ceramic: measurement by hole-drilling. Dent Mater. 2012;28:378–84.CrossRefPubMed
14.
Zurück zum Zitat Wang H, Aboushelib MN, Feilzer AJ. Strength influencing variables on CAD/CAM zirconia frameworks. Dent Mater. 2008;24:633–8.CrossRefPubMed Wang H, Aboushelib MN, Feilzer AJ. Strength influencing variables on CAD/CAM zirconia frameworks. Dent Mater. 2008;24:633–8.CrossRefPubMed
15.
Zurück zum Zitat Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci. 2007;115:161–6.CrossRefPubMed Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci. 2007;115:161–6.CrossRefPubMed
16.
Zurück zum Zitat Comlekoglu M, Dundar M, Özcan M, Gungor M, Gokce B, Artunc C. Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns. Oper Dent. 2009;34:586–92.CrossRefPubMed Comlekoglu M, Dundar M, Özcan M, Gungor M, Gokce B, Artunc C. Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns. Oper Dent. 2009;34:586–92.CrossRefPubMed
17.
Zurück zum Zitat Aboushelib MN. Fatigue and fracture resistance of zirconia crowns prepared with different finish line designs. J Prosthodont. 2012;21:22–7.CrossRefPubMed Aboushelib MN. Fatigue and fracture resistance of zirconia crowns prepared with different finish line designs. J Prosthodont. 2012;21:22–7.CrossRefPubMed
18.
Zurück zum Zitat Kou W, Li D, Qiao J, Chen L, Ding Y, Sjogren G. A 3D numerical simulation of stress distribution and fracture process in a zirconia-based FPD framework. J Biomed Mater Res B Appl Biomater. 2011;96:376–85.CrossRefPubMed Kou W, Li D, Qiao J, Chen L, Ding Y, Sjogren G. A 3D numerical simulation of stress distribution and fracture process in a zirconia-based FPD framework. J Biomed Mater Res B Appl Biomater. 2011;96:376–85.CrossRefPubMed
19.
Zurück zum Zitat Sundh A, Molin M, Sjogren G. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. Dent Mater. 2005;21:476–82.CrossRefPubMed Sundh A, Molin M, Sjogren G. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. Dent Mater. 2005;21:476–82.CrossRefPubMed
20.
Zurück zum Zitat Sundh A, Sjogren G. Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering. Dent Mater. 2006;22:778–84.CrossRefPubMed Sundh A, Sjogren G. Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering. Dent Mater. 2006;22:778–84.CrossRefPubMed
21.
Zurück zum Zitat Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont. 2001;14:231–8.PubMed Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont. 2001;14:231–8.PubMed
22.
Zurück zum Zitat Taskonak B, Griggs JA, Mecholsky JJ Jr, Yan JH. Analysis of subcritical crack growth in dental ceramics using fracture mechanics and fractography. Dent Mater. 2008;24:700–7.CrossRefPubMed Taskonak B, Griggs JA, Mecholsky JJ Jr, Yan JH. Analysis of subcritical crack growth in dental ceramics using fracture mechanics and fractography. Dent Mater. 2008;24:700–7.CrossRefPubMed
23.
Zurück zum Zitat Sundh A, Sjogren G. A comparison of fracture strength of yttrium-oxide- partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics. J Oral Rehabil. 2004;31:682–8.CrossRefPubMed Sundh A, Sjogren G. A comparison of fracture strength of yttrium-oxide- partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics. J Oral Rehabil. 2004;31:682–8.CrossRefPubMed
Metadaten
Titel
Fracture resistance of three-unit zirconia fixed partial denture with modified framework
verfasst von
Arthur Partiyan
Essam Osman
Mohammad M. Rayyan
Moustafa Aboushelib
Ahmed Ibrahim
Ryo Jimbo
Publikationsdatum
15.04.2016
Verlag
Springer Japan
Erschienen in
Odontology / Ausgabe 1/2017
Print ISSN: 1618-1247
Elektronische ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-016-0242-9

Weitere Artikel der Ausgabe 1/2017

Odontology 1/2017 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.