Skip to main content
Erschienen in: Journal of Digital Imaging 4/2012

01.08.2012

Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software

verfasst von: Gihyeon Kim, Ho-Joong Jung, Han-Jun Lee, Jae-Sung Lee, Seungbum Koo, Seung-Hwan Chang

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 4/2012

Einloggen, um Zugang zu erhalten

Abstract

There is a growing interest in three-dimensional computed tomography (3D-CT) as a research tool for the study of bone, joint anatomy, and kinematics. However, when CT data are processed and handled manually using image processing programs to yield 3D image and coordinate value, systematic and random errors should be validated. We evaluated the accuracy and reliability of length measurement on CT with OsiriX software. 3D-CT scans were made of 14 frozen pig knees with five transosseous holes in the metaphyseal portion of femur. The lengths between tunnel orifices were measured using Mitutoyo Digimatic digital calipers to establish the gold standard, and with the OsiriX program in 3D multi-planar reformatting mode for comparison. All measurements were recorded by a principal (replicate 1, trial 1) and a secondary observer (replicate 2, trial 1) and were repeated once by each observer (trial 2). The mean differences between OsiriX and real measurements were less than 0.1 mm in both replicates, and maximum differences were less than 0.3 mm. There were no significant differences between the replicates and real measurements (p = 0.544 and 0.622 for replicates 1 and 2, respectively). The intraclass correlation coefficients (ICC) were very high between trials and between replicates (ICC = 0.998 and 0.999, respectively). For kinematic analysis of the knees, length measurements on 3D-CT using OsiriX program can be used as alternatives to real measurements with less than 0.3-mm accuracy and very high reliability.
Literatur
1.
Zurück zum Zitat Forsythe B, Kopf S, Wong AK, et al: The location of femoral and tibial tunnels in anatomic double-bundle anterior cruciate ligament reconstruction analyzed by three-dimensional computed tomography models. J Bone Joint Surg Am 92(6):1418–1426, 2010PubMedCrossRef Forsythe B, Kopf S, Wong AK, et al: The location of femoral and tibial tunnels in anatomic double-bundle anterior cruciate ligament reconstruction analyzed by three-dimensional computed tomography models. J Bone Joint Surg Am 92(6):1418–1426, 2010PubMedCrossRef
2.
Zurück zum Zitat Jeong WS, Yoo YS, Kim DY, et al: An analysis of the posterior cruciate ligament isometric position using an in vivo 3-dimensional computed tomography-based knee joint model. Arthroscopy 26(10):1333–1339, 2010PubMedCrossRef Jeong WS, Yoo YS, Kim DY, et al: An analysis of the posterior cruciate ligament isometric position using an in vivo 3-dimensional computed tomography-based knee joint model. Arthroscopy 26(10):1333–1339, 2010PubMedCrossRef
3.
Zurück zum Zitat Karlo CA, Steurer-Dober I, Leonardi M, Pfirrmann CW, Zanetti M, Hodler J: MR/CT image fusion of the spine after spondylodesis: a feasibility study. Eur Spine J 19(10):1771–1775, 2010PubMedCrossRef Karlo CA, Steurer-Dober I, Leonardi M, Pfirrmann CW, Zanetti M, Hodler J: MR/CT image fusion of the spine after spondylodesis: a feasibility study. Eur Spine J 19(10):1771–1775, 2010PubMedCrossRef
4.
Zurück zum Zitat Kopf S, Forsythe B, Wong AK, et al: Nonanatomic tunnel position in traditional transtibial single-bundle anterior cruciate ligament reconstruction evaluated by three-dimensional computed tomography. J Bone Joint Surg Am 92(6):1427–1431, 2010PubMedCrossRef Kopf S, Forsythe B, Wong AK, et al: Nonanatomic tunnel position in traditional transtibial single-bundle anterior cruciate ligament reconstruction evaluated by three-dimensional computed tomography. J Bone Joint Surg Am 92(6):1427–1431, 2010PubMedCrossRef
5.
Zurück zum Zitat Nakahara I, Takao M, Sakai T, Nishii T, Yoshikawa H, Sugano N: Gender differences in 3D morphology and bony impingement of human hips. J Orthop Res 29(3):333–339, 2011PubMedCrossRef Nakahara I, Takao M, Sakai T, Nishii T, Yoshikawa H, Sugano N: Gender differences in 3D morphology and bony impingement of human hips. J Orthop Res 29(3):333–339, 2011PubMedCrossRef
6.
Zurück zum Zitat Maloul A, Fialkov J, Whyne C: The Impact of Voxel Size-Based Inaccuracies on the Mechanical Behavior of Thin Bone Structures. Ann Biomed Eng, 2010 Maloul A, Fialkov J, Whyne C: The Impact of Voxel Size-Based Inaccuracies on the Mechanical Behavior of Thin Bone Structures. Ann Biomed Eng, 2010
7.
Zurück zum Zitat Newman DL, Dougherty G, al Obaid A, al Hajrasy H: Limitations of clinical CT in assessing cortical thickness and density. Phys Med Biol 43(3):619–626, 1998PubMedCrossRef Newman DL, Dougherty G, al Obaid A, al Hajrasy H: Limitations of clinical CT in assessing cortical thickness and density. Phys Med Biol 43(3):619–626, 1998PubMedCrossRef
8.
Zurück zum Zitat Rosset A, Spadola L, Ratib O: OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17(3):205–216, 2004PubMedCrossRef Rosset A, Spadola L, Ratib O: OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging 17(3):205–216, 2004PubMedCrossRef
9.
Zurück zum Zitat Rosset C, Rosset A, Ratib O: General consumer communication tools for improved image management and communication in medicine. J Digit Imaging 18(4):270–279, 2005PubMedCrossRef Rosset C, Rosset A, Ratib O: General consumer communication tools for improved image management and communication in medicine. J Digit Imaging 18(4):270–279, 2005PubMedCrossRef
10.
Zurück zum Zitat Woo SL, Orlando CA, Camp JF, Akeson WH: Effects of postmortem storage by freezing on ligament tensile behavior. J Biomech 19(5):399–404, 1986PubMedCrossRef Woo SL, Orlando CA, Camp JF, Akeson WH: Effects of postmortem storage by freezing on ligament tensile behavior. J Biomech 19(5):399–404, 1986PubMedCrossRef
11.
Zurück zum Zitat Faul F, Erdfelder E, Lang AG, Buchner A: G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39(2):175–191, 2007PubMedCrossRef Faul F, Erdfelder E, Lang AG, Buchner A: G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39(2):175–191, 2007PubMedCrossRef
12.
Zurück zum Zitat Iriuchishima T, Horaguchi T, Kubomura T, Morimoto Y, Fu FH: Evaluation of the intercondylar roof impingement after anatomical double-bundle anterior cruciate ligament reconstruction using 3D-CT. Knee Surg Sports Traumatol Arthrosc 19(4):674–679, 2011PubMedCrossRef Iriuchishima T, Horaguchi T, Kubomura T, Morimoto Y, Fu FH: Evaluation of the intercondylar roof impingement after anatomical double-bundle anterior cruciate ligament reconstruction using 3D-CT. Knee Surg Sports Traumatol Arthrosc 19(4):674–679, 2011PubMedCrossRef
13.
Zurück zum Zitat Lertwanich P, Martins CA, Asai S, Ingham SJ, Smolinski P, Fu FH: Anterior cruciate ligament tunnel position measurement reliability on 3-dimensional reconstructed computed tomography. Arthroscopy 27(3):391–398, 2011PubMedCrossRef Lertwanich P, Martins CA, Asai S, Ingham SJ, Smolinski P, Fu FH: Anterior cruciate ligament tunnel position measurement reliability on 3-dimensional reconstructed computed tomography. Arthroscopy 27(3):391–398, 2011PubMedCrossRef
14.
Zurück zum Zitat Van Eck CF, Martins CA, Kopf S, Lertwanich P, Fu FH, Tashman S: Correlation between the 2-dimensional notch width and the 3-dimensional notch volume: a cadaveric study. Arthroscopy 27(2):207–212, 2011PubMedCrossRef Van Eck CF, Martins CA, Kopf S, Lertwanich P, Fu FH, Tashman S: Correlation between the 2-dimensional notch width and the 3-dimensional notch volume: a cadaveric study. Arthroscopy 27(2):207–212, 2011PubMedCrossRef
15.
Zurück zum Zitat van Eck CF, Martins CA, Lorenz SG, Fu FH, Smolinski P: Assessment of correlation between knee notch width index and the three-dimensional notch volume. Knee Surg Sports Traumatol Arthrosc 18(9):1239–1244, 2010PubMedCrossRef van Eck CF, Martins CA, Lorenz SG, Fu FH, Smolinski P: Assessment of correlation between knee notch width index and the three-dimensional notch volume. Knee Surg Sports Traumatol Arthrosc 18(9):1239–1244, 2010PubMedCrossRef
16.
Zurück zum Zitat van Eck CF, Schreiber VM, Liu TT, Fu FH: The anatomic approach to primary, revision and augmentation anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 18(9):1154–1163, 2010PubMedCrossRef van Eck CF, Schreiber VM, Liu TT, Fu FH: The anatomic approach to primary, revision and augmentation anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 18(9):1154–1163, 2010PubMedCrossRef
17.
Zurück zum Zitat Camarda L, DA M, Patera GP, Filosto L, Laprade RF: Avoiding tunnel collisions between fibular collateral ligament and ACL posterolateral bundle reconstruction. Knee Surg Sports Traumatol Arthrosc 19(4):598–603, 2011PubMedCrossRef Camarda L, DA M, Patera GP, Filosto L, Laprade RF: Avoiding tunnel collisions between fibular collateral ligament and ACL posterolateral bundle reconstruction. Knee Surg Sports Traumatol Arthrosc 19(4):598–603, 2011PubMedCrossRef
18.
Zurück zum Zitat Greiner P, Magnussen RA, Lustig S, Demey G, Neyret P, Servien E: Computed tomography evaluation of the femoral and tibial attachments of the posterior cruciate ligament in vitro. Knee Surg Sports Traumatol Arthrosc, 2011 Greiner P, Magnussen RA, Lustig S, Demey G, Neyret P, Servien E: Computed tomography evaluation of the femoral and tibial attachments of the posterior cruciate ligament in vitro. Knee Surg Sports Traumatol Arthrosc, 2011
19.
Zurück zum Zitat Jenny JY, Ciobanu E, Clavert P, Jaeger JH, Kahn JL, Kempf JF: Anatomic attachment of the ACL. Comparison between radiological and CT analysis. Knee Surg Sports Traumatol Arthrosc 19(5):806–810, 2011PubMedCrossRef Jenny JY, Ciobanu E, Clavert P, Jaeger JH, Kahn JL, Kempf JF: Anatomic attachment of the ACL. Comparison between radiological and CT analysis. Knee Surg Sports Traumatol Arthrosc 19(5):806–810, 2011PubMedCrossRef
20.
Zurück zum Zitat Taketomi S, Nakagawa T, Takeda H, et al: Anatomical placement of double femoral tunnels in anterior cruciate ligament reconstruction: anteromedial tunnel first or posterolateral tunnel first? Knee Surg Sports Traumatol Arthrosc 19(3):424–431, 2011PubMedCrossRef Taketomi S, Nakagawa T, Takeda H, et al: Anatomical placement of double femoral tunnels in anterior cruciate ligament reconstruction: anteromedial tunnel first or posterolateral tunnel first? Knee Surg Sports Traumatol Arthrosc 19(3):424–431, 2011PubMedCrossRef
21.
Zurück zum Zitat Sugimoto M, Yasuda H, Koda K, et al: Virtual CO2 MDCT pancreatography: a new feasible technique for minimally invasive pancreatectomy in intraductal papillary mucinous neoplasms. Hepatogastroenterology 55(81):270–274, 2008PubMed Sugimoto M, Yasuda H, Koda K, et al: Virtual CO2 MDCT pancreatography: a new feasible technique for minimally invasive pancreatectomy in intraductal papillary mucinous neoplasms. Hepatogastroenterology 55(81):270–274, 2008PubMed
22.
Zurück zum Zitat Melissano G, Bertoglio L, Civelli V, et al: Demonstration of the Adamkiewicz artery by multidetector computed tomography angiography analysed with the open-source software OsiriX. Eur J Vasc Endovasc Surg 37(4):395–400, 2009PubMedCrossRef Melissano G, Bertoglio L, Civelli V, et al: Demonstration of the Adamkiewicz artery by multidetector computed tomography angiography analysed with the open-source software OsiriX. Eur J Vasc Endovasc Surg 37(4):395–400, 2009PubMedCrossRef
Metadaten
Titel
Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software
verfasst von
Gihyeon Kim
Ho-Joong Jung
Han-Jun Lee
Jae-Sung Lee
Seungbum Koo
Seung-Hwan Chang
Publikationsdatum
01.08.2012
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 4/2012
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-012-9458-6

Weitere Artikel der Ausgabe 4/2012

Journal of Digital Imaging 4/2012 Zur Ausgabe

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.