Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 11/2012

01.11.2012 | Symposium: Papers Presented at the 2011 Meeting of the International Hip Society

Does Impact Sport Activity Influence Total Hip Arthroplasty Durability?

verfasst von: Matthieu Ollivier, MD, Solenne Frey, MD, Sebastien Parratte, MD, PhD, Xavier Flecher, MD, PhD, Jean-Noël Argenson, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 11/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

Return to sport is a key patient demand after hip arthroplasty and some patients are even involved in high-impact sports. Although polyethylene wear is related to the number of cycles and the importance of the load, it is unclear whether high-impact sport per se influences THA durability.

Questions/purposes

Therefore, we compared (1) function between the patients involved in high-impact sports and the patients with lower activities as measured by the Harris hip score (HHS) and the Hip Osteoarthritis Outcome Score (HOOS); (2) linear wear rates; and (3) survivorships considering revision for mechanical failure with radiographic signs of aseptic loosening as the end point.

Methods

We retrospectively identified 70 patients who engaged in high-impact sports and 140 with low activity levels from among 843 THAs from a prospectively collected database performed between September 1, 1995, and December 31, 2000. Patients were evaluated at a minimum followup of 10 years (mean, 11 years; range, 10–15 years) by two independent observers. We obtained a HHS and HOOS at each followup.

Results

The mean HOOS was higher in the high-impact group for three of the five subscales of the HOOS. Mean linear wear was higher in the high-impact group than in the low-activities group. We also found a higher number of revisions in the high-activity group.

Conclusions

Our observations confirm concern about the risk of THA mechanical failures related to high-impact sport, and patient and surgeons alike should be aware of these risks of mechanical failures.

Level of Evidence

Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Bedigrew KM, Ruh EL, Zhang Q, Clohisy JC, Barrack RL, Nunley RM. 2011 Marshall Urist Young Investigator Award: when to release patients to high-impact activities after hip resurfacing. Clin Orthop Relat Res. 2012;470:299–306.PubMedCrossRef Bedigrew KM, Ruh EL, Zhang Q, Clohisy JC, Barrack RL, Nunley RM. 2011 Marshall Urist Young Investigator Award: when to release patients to high-impact activities after hip resurfacing. Clin Orthop Relat Res. 2012;470:299–306.PubMedCrossRef
2.
Zurück zum Zitat Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840.PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840.PubMed
3.
Zurück zum Zitat Calvert GT, Devane PA, Fielden J, Adams K, Horne J. Double-blind, prospective, randomized controlled trial comparing highly cross-linked and conventional polyethylene in primary total hip arthroplasty. J Arthroplasty. 2009;24:505–510.PubMedCrossRef Calvert GT, Devane PA, Fielden J, Adams K, Horne J. Double-blind, prospective, randomized controlled trial comparing highly cross-linked and conventional polyethylene in primary total hip arthroplasty. J Arthroplasty. 2009;24:505–510.PubMedCrossRef
4.
Zurück zum Zitat Charnley J. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br. 1972;54:61–76.PubMed Charnley J. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br. 1972;54:61–76.PubMed
5.
Zurück zum Zitat Charnley J, Cupic Z. The nine and ten year results of the low-friction arthroplasty of the hip. Clin Orthop Relat Res. 1973;95:9–25.PubMed Charnley J, Cupic Z. The nine and ten year results of the low-friction arthroplasty of the hip. Clin Orthop Relat Res. 1973;95:9–25.PubMed
6.
Zurück zum Zitat DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
7.
Zurück zum Zitat Devane PA, Home JG, Martin K, Coldham G, Krause B. Three dimensional polyethylene wear of a press-fit titanium prosthesis: factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12: 256–266.PubMedCrossRef Devane PA, Home JG, Martin K, Coldham G, Krause B. Three dimensional polyethylene wear of a press-fit titanium prosthesis: factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12: 256–266.PubMedCrossRef
8.
Zurück zum Zitat Dumbleton JH, Manley MT, Edidin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty. 2002;17:649–661.PubMedCrossRef Dumbleton JH, Manley MT, Edidin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty. 2002;17:649–661.PubMedCrossRef
9.
Zurück zum Zitat Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed
10.
Zurück zum Zitat Flecher X, Pearce O, Parratte S, Aubaniac JM, Argenson JN. Custom cementless stem improves hip function in young patients at 15-year followup. Clin Orthop Relat Res. 2010;468:747–755.PubMedCrossRef Flecher X, Pearce O, Parratte S, Aubaniac JM, Argenson JN. Custom cementless stem improves hip function in young patients at 15-year followup. Clin Orthop Relat Res. 2010;468:747–755.PubMedCrossRef
11.
Zurück zum Zitat Flugsrud GB, Nordsletten L, Espehaug B, Havelin LI, Meyer HE. The effect of middle-age body weight and physical activity on the risk of early revision hip arthroplasty: a cohort study of 1535 individuals. Acta Orthop Scand. 2007;78:99–107.CrossRef Flugsrud GB, Nordsletten L, Espehaug B, Havelin LI, Meyer HE. The effect of middle-age body weight and physical activity on the risk of early revision hip arthroplasty: a cohort study of 1535 individuals. Acta Orthop Scand. 2007;78:99–107.CrossRef
12.
Zurück zum Zitat Girard J, Touraine D, Soenen M, Massin P, Laffargue P, Migaud H. Measurement of head penetration on digitalized radiographs: reproducibility and accuracy. Rev Chir Orthop. 2005;91:137–142.PubMed Girard J, Touraine D, Soenen M, Massin P, Laffargue P, Migaud H. Measurement of head penetration on digitalized radiographs: reproducibility and accuracy. Rev Chir Orthop. 2005;91:137–142.PubMed
13.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC. ‘Modes of failure’ of cemented stem-type femoral components. Clin Orthop Relat Res. 1979;141:17–27.PubMed Gruen TA, McNeice GM, Amstutz HC. ‘Modes of failure’ of cemented stem-type femoral components. Clin Orthop Relat Res. 1979;141:17–27.PubMed
14.
Zurück zum Zitat Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed
15.
Zurück zum Zitat Healy WL, Iorio R, Lemos MJ. Athletic activity after joint replacement. Am J Sports Med. 2001;29:377–388.PubMed Healy WL, Iorio R, Lemos MJ. Athletic activity after joint replacement. Am J Sports Med. 2001;29:377–388.PubMed
16.
Zurück zum Zitat Huch K, Müller KA, Stürmer T, Brenner H, Puhl W, Günther KP. Sports activities 5 years after total knee or hip arthroplasty: the Ulm Osteoarthritis Study. Ann Rheum Dis. 2005;64:1715–1720.PubMedCrossRef Huch K, Müller KA, Stürmer T, Brenner H, Puhl W, Günther KP. Sports activities 5 years after total knee or hip arthroplasty: the Ulm Osteoarthritis Study. Ann Rheum Dis. 2005;64:1715–1720.PubMedCrossRef
17.
Zurück zum Zitat Huet R, Sakona A, Kurtz SM. Strength and reliability of alumina ceramic femoral heads: review of design, testing, and retrieval analysis. J Mech Behav Biomed Mater. 2011;4:476–483.PubMedCrossRef Huet R, Sakona A, Kurtz SM. Strength and reliability of alumina ceramic femoral heads: review of design, testing, and retrieval analysis. J Mech Behav Biomed Mater. 2011;4:476–483.PubMedCrossRef
18.
Zurück zum Zitat Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91:1344–1349.PubMedCrossRef Jarrett CA, Ranawat AS, Bruzzone M, Blum YC, Rodriguez JA, Ranawat CS. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Joint Surg Am. 2009;91:1344–1349.PubMedCrossRef
19.
Zurück zum Zitat Kilgus DJ, Moreland JR, Finerman GA, Funahashi TT, Tipton JS. Catastrophic wear of tibial polyethylene inserts. Clin Orthop Relat Res. 1991;273:223–231.PubMed Kilgus DJ, Moreland JR, Finerman GA, Funahashi TT, Tipton JS. Catastrophic wear of tibial polyethylene inserts. Clin Orthop Relat Res. 1991;273:223–231.PubMed
20.
Zurück zum Zitat Klein GR, Levine BR, Hozack WJ, Strauss EJ, D’Antonio JA, Macaulay W. Return to athletic activity after total hip arthroplasty : consensus guidelines based on a survey of the Hip Society and American Association of Hip and Knee Surgeons. J Arthroplasty. 2007;22:171–175.PubMedCrossRef Klein GR, Levine BR, Hozack WJ, Strauss EJ, D’Antonio JA, Macaulay W. Return to athletic activity after total hip arthroplasty : consensus guidelines based on a survey of the Hip Society and American Association of Hip and Knee Surgeons. J Arthroplasty. 2007;22:171–175.PubMedCrossRef
21.
Zurück zum Zitat Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement. Lancet. 2007;370:1508–1519.PubMedCrossRef Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement. Lancet. 2007;370:1508–1519.PubMedCrossRef
22.
Zurück zum Zitat Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518–522.PubMed Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518–522.PubMed
23.
Zurück zum Zitat Lübbeke A, Garavaglia G, Barea C, Stern R, Peter R, Hoffmeyer P. Influence of patient activity on femoral osteolysis at five and ten years following hybrid total hip replacement. J Bone Joint Surg Br. 2011;93:456–463.PubMedCrossRef Lübbeke A, Garavaglia G, Barea C, Stern R, Peter R, Hoffmeyer P. Influence of patient activity on femoral osteolysis at five and ten years following hybrid total hip replacement. J Bone Joint Surg Br. 2011;93:456–463.PubMedCrossRef
24.
Zurück zum Zitat Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration. J Arthroplasty. 1989;4:245–251.PubMedCrossRef Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration. J Arthroplasty. 1989;4:245–251.PubMedCrossRef
25.
Zurück zum Zitat McGrory BJ, Stuart MJ, Sim FH. Participation in sports after hip and knee arthroplasty: review of literature and survey of surgeon preferences. Mayo Clin Proc. 1995;70:342–348.PubMedCrossRef McGrory BJ, Stuart MJ, Sim FH. Participation in sports after hip and knee arthroplasty: review of literature and survey of surgeon preferences. Mayo Clin Proc. 1995;70:342–348.PubMedCrossRef
26.
Zurück zum Zitat Migaud H, Putman S, Krantz N, Vasseur L, Girard J. Cementless metal-on-metal versus ceramic-on-polyethylene hip arthroplasty in patients less than fifty years of age: a comparative study with twelve to fourteen-year follow-up. J Bone Joint Surg Am. 2011;93:137–142.PubMedCrossRef Migaud H, Putman S, Krantz N, Vasseur L, Girard J. Cementless metal-on-metal versus ceramic-on-polyethylene hip arthroplasty in patients less than fifty years of age: a comparative study with twelve to fourteen-year follow-up. J Bone Joint Surg Am. 2011;93:137–142.PubMedCrossRef
27.
Zurück zum Zitat Mont MA, Marker DR, Seyler TM, Gordon N, Hungerford DS, Jones LC. Knee arthroplasties have similar results in high- and low-activity patients. Clin Orthop Relat Res. 2007;460:165–173.PubMed Mont MA, Marker DR, Seyler TM, Gordon N, Hungerford DS, Jones LC. Knee arthroplasties have similar results in high- and low-activity patients. Clin Orthop Relat Res. 2007;460:165–173.PubMed
28.
Zurück zum Zitat Nilsdotter AK, Lohmander LS, Klassbo M, Roos EM. Hip disability and Osteoarthritis Outcome Score (HOOS)—validity and responsiveness in total hip replacement. BMC Musculoskelet Disord. 2003;30:4–10. Nilsdotter AK, Lohmander LS, Klassbo M, Roos EM. Hip disability and Osteoarthritis Outcome Score (HOOS)—validity and responsiveness in total hip replacement. BMC Musculoskelet Disord. 2003;30:4–10.
29.
Zurück zum Zitat Ornetti P, Parratte S, Gossec L, Tavernier C, Argenson J-N, Roos EM, Guillemin F, Maillefert JF. Cross-cultural adaptation and validation of the French version of the Hip disability and Osteoarthritis Outcome Score (HOOS) in hip osteoarthritis patients. Osteoarthritis Cartilage. 2010;18:522–529.PubMedCrossRef Ornetti P, Parratte S, Gossec L, Tavernier C, Argenson J-N, Roos EM, Guillemin F, Maillefert JF. Cross-cultural adaptation and validation of the French version of the Hip disability and Osteoarthritis Outcome Score (HOOS) in hip osteoarthritis patients. Osteoarthritis Cartilage. 2010;18:522–529.PubMedCrossRef
30.
Zurück zum Zitat Ritter MA, Meding JB. Total hip arthroplasty. Can the patient play sports again? Orthopedics. 1987;10:1447–1452.PubMed Ritter MA, Meding JB. Total hip arthroplasty. Can the patient play sports again? Orthopedics. 1987;10:1447–1452.PubMed
31.
Zurück zum Zitat Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa’vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. The John Charnley Award. Wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.PubMedCrossRef Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa’vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. The John Charnley Award. Wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.PubMedCrossRef
32.
Zurück zum Zitat Sechriest VF 2nd, Kyle RF, Marek DJ, Spates JD, Saleh KJ, Kuskowski M. Activity level in young patients with primary total hip arthroplasty: a 5-year minimum follow-up. J Arthroplasty. 2007;22:39–47.PubMedCrossRef Sechriest VF 2nd, Kyle RF, Marek DJ, Spates JD, Saleh KJ, Kuskowski M. Activity level in young patients with primary total hip arthroplasty: a 5-year minimum follow-up. J Arthroplasty. 2007;22:39–47.PubMedCrossRef
33.
Zurück zum Zitat Seyler TM, Mont MA, Ragland PS, Kachwala MM, Delanois RE. Sports activity after total hip and knee arthroplasty: specific recommendations concerning tennis. Sports Med. 2006;36:571–583.PubMedCrossRef Seyler TM, Mont MA, Ragland PS, Kachwala MM, Delanois RE. Sports activity after total hip and knee arthroplasty: specific recommendations concerning tennis. Sports Med. 2006;36:571–583.PubMedCrossRef
34.
Zurück zum Zitat Trousdale RT, McGrory BJ, Berry DJ, Becker MW, Harmsen WS. Patients’ concerns prior to undergoing total hip and total knee arthroplasty. Mayo Clin Proc. 1999;74:978–982.PubMed Trousdale RT, McGrory BJ, Berry DJ, Becker MW, Harmsen WS. Patients’ concerns prior to undergoing total hip and total knee arthroplasty. Mayo Clin Proc. 1999;74:978–982.PubMed
35.
Zurück zum Zitat Visuri T, Honkanen R. Total hip replacement: its influence on spontaneous recreation exercise habits. Arch Phys Med Rehabil. 1980;61:325–328.PubMed Visuri T, Honkanen R. Total hip replacement: its influence on spontaneous recreation exercise habits. Arch Phys Med Rehabil. 1980;61:325–328.PubMed
36.
Zurück zum Zitat Weiss JM, Noble PC, Conditt MA, Kohl HW, Roberts S, Cook KF, Gordon MJ, Mathis KB. What functional activities are important to patients with knee replacements? Clin Orthop Relat Res. 2002;404:172–188.PubMedCrossRef Weiss JM, Noble PC, Conditt MA, Kohl HW, Roberts S, Cook KF, Gordon MJ, Mathis KB. What functional activities are important to patients with knee replacements? Clin Orthop Relat Res. 2002;404:172–188.PubMedCrossRef
37.
Zurück zum Zitat Wright JG, Young NL. The patient-specific index: asking patients what they want. J Bone Joint Surg Am. 1997;79:974–983.PubMed Wright JG, Young NL. The patient-specific index: asking patients what they want. J Bone Joint Surg Am. 1997;79:974–983.PubMed
38.
Zurück zum Zitat Wright TM, Bartel DL. The problem of surface damage in polyethylene total knee components. Clin Orthop Relat Res. 1986;205:67–74.PubMed Wright TM, Bartel DL. The problem of surface damage in polyethylene total knee components. Clin Orthop Relat Res. 1986;205:67–74.PubMed
39.
Zurück zum Zitat Xenos JS, Hopkinson WJ, Callaghan JJ, Heekin RD, Savory CG. Osteolysis around an uncemented cobalt chrome total hip arthroplasty. Clin Orthop Relat Res. 1995;317:29–36.PubMed Xenos JS, Hopkinson WJ, Callaghan JJ, Heekin RD, Savory CG. Osteolysis around an uncemented cobalt chrome total hip arthroplasty. Clin Orthop Relat Res. 1995;317:29–36.PubMed
40.
Zurück zum Zitat Zahiri CA, Scmalzried TP, Szuszczewcz ES, Amstutz HC. Assessing activity in joint replacement patients. J Arthroplasty. 1998;13:890–895.PubMedCrossRef Zahiri CA, Scmalzried TP, Szuszczewcz ES, Amstutz HC. Assessing activity in joint replacement patients. J Arthroplasty. 1998;13:890–895.PubMedCrossRef
Metadaten
Titel
Does Impact Sport Activity Influence Total Hip Arthroplasty Durability?
verfasst von
Matthieu Ollivier, MD
Solenne Frey, MD
Sebastien Parratte, MD, PhD
Xavier Flecher, MD, PhD
Jean-Noël Argenson, MD
Publikationsdatum
01.11.2012
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 11/2012
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-012-2362-z

Weitere Artikel der Ausgabe 11/2012

Clinical Orthopaedics and Related Research® 11/2012 Zur Ausgabe

Symposium: Papers Presented at the 2011 Meeting of the International Hip Society

Aggressive Early Débridement for Treatment of Acutely Infected Cemented Total Hip Arthroplasty

Symposium: Papers Presented at the 2011 Meeting of the International Hip Society

Does PFNA II Avoid Lateral Cortex Impingement for Unstable Peritrochanteric Fractures?

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.