01.03.2007 | Brief Report

Vascular erosion by central venous catheters used for total parenteral nutrition

verfasst von: Criona Walshe, Dermot Phelan, Jane Bourke, Donal Buggy

Erschienen in: Intensive Care Medicine | Ausgabe 3/2007

Einloggen, um Zugang zu erhalten

Abstract

Objective

To establish the incidence of central venous catheter erosion in a patient cohort receiving total parenteral nutrition and to examine risk factors and complications of vascular erosion.

Design and setting

Review of prospectively collected intravenous nutrition service audit records in a tertiary university hospital.

Results

Records of 1,499 patients (2,992 catheters) were studied over the 14 year period 1991–2005. Fisher's exact test was used to determine statistical significance. Five erosions occurred, representing an incidence of 0.17% per catheter or 0.28 per 1,000 catheter days. One of the five patients died from ensuing complications. Mean time to onset of symptoms was 3.6 days following catheter insertion. Symptoms/signs included dyspnoea (n = 5), chest pain (n = 2) and pleural effusion (n = 5). Diagnosis was delayed by a mean of 1.6 days. Three erosions occurred in left subclavian catheters (n = 583); two in left internal jugular catheters (n = 453). None occurred in right-sided catheters (n = 1956). The relative risk of erosion occurring in left-sided catheters compared to right was 2.9 (95% CI 2.76–3.00; p = 0.009). There was no statistically significantly greater risk of vascular erosion in subclavian than internal jugular catheters (relative risk 0.9; p = 1.0). Older age was a statistically significant risk factor (p = 0.009); female sex was not (p = 0.18).

Conclusion

In patients receiving total parenteral nutrition via central venous catheters, erosion has an incidence per catheter of 0.17% and is more likely to occur in left-sided catheters and elderly patients.
Literatur
1.
Zurück zum Zitat Duntley P, Siever J, Korwes M, Harpel K, Heffner J (1992) Vascular erosion by central venous catheters. clinical features and outcome. Chest 101:1633–1638PubMed Duntley P, Siever J, Korwes M, Harpel K, Heffner J (1992) Vascular erosion by central venous catheters. clinical features and outcome. Chest 101:1633–1638PubMed
2.
Zurück zum Zitat Mukau L, Talamini M, Sitzmann J (1991) Risk factors for central venous catheter-related vascular erosions. J Parenter Enter Nutr 15:513–516 Mukau L, Talamini M, Sitzmann J (1991) Risk factors for central venous catheter-related vascular erosions. J Parenter Enter Nutr 15:513–516
3.
Zurück zum Zitat Vesely T (2003) Central venous catheter tip position: a continuing controversy. J Vasc Interv Radiol 24:527–534 Vesely T (2003) Central venous catheter tip position: a continuing controversy. J Vasc Interv Radiol 24:527–534
4.
Zurück zum Zitat Stonelake PA, Bodenham AR (2006) The carina as a radiological landmark for central venous catheter tip position. Br J Anaesth 96:335–340PubMedCrossRef Stonelake PA, Bodenham AR (2006) The carina as a radiological landmark for central venous catheter tip position. Br J Anaesth 96:335–340PubMedCrossRef
5.
Zurück zum Zitat Aslamy Z, Dewald CL, Heffner JE (1998) MRI of central venous anatomy: implications for central venous catheter insertion. Chest 114:820–826PubMed Aslamy Z, Dewald CL, Heffner JE (1998) MRI of central venous anatomy: implications for central venous catheter insertion. Chest 114:820–826PubMed
6.
Zurück zum Zitat Kowalshi CM, Kaufman JA, Rivitz SM, Geller SC, Waltman AC (1997) Migration of central venous catheters: implications for initial catheter tip positioning. J Vasc Interv Radiol 8:443–447CrossRef Kowalshi CM, Kaufman JA, Rivitz SM, Geller SC, Waltman AC (1997) Migration of central venous catheters: implications for initial catheter tip positioning. J Vasc Interv Radiol 8:443–447CrossRef
7.
Zurück zum Zitat Tocino I, Watanabe A (1986) Impending catheter perforation of superior vena cava: radiographic recognition. Am J Roentgenol 146:487–490 Tocino I, Watanabe A (1986) Impending catheter perforation of superior vena cava: radiographic recognition. Am J Roentgenol 146:487–490
8.
Zurück zum Zitat Polderman KH, Girbes ARJ (2002) Central venous catheter use. 1. Mechanical complications. Intensive Care Med 28:1–17PubMedCrossRef Polderman KH, Girbes ARJ (2002) Central venous catheter use. 1. Mechanical complications. Intensive Care Med 28:1–17PubMedCrossRef
9.
Zurück zum Zitat Bersten A, Williams R, Phillips G (1988) Central venous catheter stiffness and its relation to vascular perforation. Anaesth Intensive Care 16:342–351PubMed Bersten A, Williams R, Phillips G (1988) Central venous catheter stiffness and its relation to vascular perforation. Anaesth Intensive Care 16:342–351PubMed
10.
Zurück zum Zitat Diaz M, Lorda I, Sanchez C, Gutierrez I, Monton JM, Vidal A (2005) Milky-white pleural effusion complicating peripherally inserted central venous catheter for total parenteral nutrition. Eur J Clin Nutr 59:302–303PubMedCrossRef Diaz M, Lorda I, Sanchez C, Gutierrez I, Monton JM, Vidal A (2005) Milky-white pleural effusion complicating peripherally inserted central venous catheter for total parenteral nutrition. Eur J Clin Nutr 59:302–303PubMedCrossRef
11.
Zurück zum Zitat Mohammed AH, Tonkin L, Jerwood C (2005) Tension hydrothorax: a near-fatal complication of central venous catheterisation. J Cardiothorac Anesth 19:512–515CrossRef Mohammed AH, Tonkin L, Jerwood C (2005) Tension hydrothorax: a near-fatal complication of central venous catheterisation. J Cardiothorac Anesth 19:512–515CrossRef
12.
Zurück zum Zitat Paw HGW (2002) Bilateral pleural effusions: unexpected complication after left internal jugular venous catheterisation for total parenteral nutrition. BJA 89:647–650PubMedCrossRef Paw HGW (2002) Bilateral pleural effusions: unexpected complication after left internal jugular venous catheterisation for total parenteral nutrition. BJA 89:647–650PubMedCrossRef
13.
Zurück zum Zitat Ellis L, Vogel S, Copeland E (1989) Central venous catheter vascular erosions: diagnosis and clinical course. Ann Surg 209:475–478PubMedCrossRef Ellis L, Vogel S, Copeland E (1989) Central venous catheter vascular erosions: diagnosis and clinical course. Ann Surg 209:475–478PubMedCrossRef
Metadaten
Titel
Vascular erosion by central venous catheters used for total parenteral nutrition
verfasst von
Criona Walshe
Dermot Phelan
Jane Bourke
Donal Buggy
Publikationsdatum
01.03.2007
Verlag
Springer-Verlag
Erschienen in
Intensive Care Medicine / Ausgabe 3/2007
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-006-0507-9

Weitere Artikel der Ausgabe 3/2007

Intensive Care Medicine 3/2007 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.