Abstract

Purpose

The purpose of this study was to verify a recently developed picture-archiving and communications system-photoshop method by comparing reliabilities between real-size paper template and the PACS-photoshop methods in preoperative planning of open-wedge high tibial osteotomy.

Methods

A prospective case series was conducted, including patients with medial osteoarthritis undergoing open-wedge high tibial osteotomy. In the preoperative planning, the picture-archiving and communications system-photoshop method and real-size paper template method were used simultaneously in all patients. Preoperative hip–knee–ankle angle, height, and angle of the osteotomy were evaluated. The reliability of this newly devised method was evaluated, and the consistency between the two methods was also evaluated using intra-class correlation coefficient.

Results

Using the picture-archiving and communications system-photoshop method, the mean correction angle and height of osteotomy gap of rater-1 were 11.7° ± 3.6° and 10.7 ± 3.6 mm, respectively. The mean correction angle and height of osteotomy gap of rater-2 were 12.0 ± 2.6 and 10.8 ± 3.6, respectively. The inter- and intra-rater reliabilities of the correction angle were 0.956 ~ 0.979 and 0.980 ~ 0.992, respectively. The inter- and intra-rater reliabilities of the height of the osteotomy gap were 0.968 ~ 0.985 and 0.971 ~ 0.994, respectively (p < 0.001). Using the real-size paper template method, the correction angle and height of the osteotomy gap were 11.5° ± 3.4° and 10.9 ± 3.8 mm, respectively. Using the picture-archiving and communications system-photoshop method, mean values of the correction angle and height of the osteotomy gap were 11.9° ± 3.6° and 10.8 ± 3.6 mm, respectively. Consistency between the two methods by comparing the means of the correction angle and the height of the osteotomy gap were 0.985 and 0.985, respectively (p < 0.001).

Conclusions

Use of the picture-archiving and communications system-photoshop method enables direct measurement of the height of the osteotomy gap with high reliability.

Level of evidence

III.
Literatur
1.
Zurück zum Zitat Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2011) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20:586–593CrossRefPubMed Akamatsu Y, Mitsugi N, Mochida Y, Taki N, Kobayashi H, Takeuchi R, Saito T (2011) Navigated opening wedge high tibial osteotomy improves intraoperative correction angle compared with conventional method. Knee Surg Sports Traumatol Arthrosc 20:586–593CrossRefPubMed
2.
Zurück zum Zitat Amis AA (2012) Biomechanics of high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 21:197–205CrossRefPubMed Amis AA (2012) Biomechanics of high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 21:197–205CrossRefPubMed
3.
Zurück zum Zitat Asada S, Akagi M, Mori S, Matsushita T, Hashimoto K, Hamanishi C (2012) Increase in posterior tibial slope would result in correction loss in frontal plane after medial open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 20:571–578CrossRefPubMed Asada S, Akagi M, Mori S, Matsushita T, Hashimoto K, Hamanishi C (2012) Increase in posterior tibial slope would result in correction loss in frontal plane after medial open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 20:571–578CrossRefPubMed
4.
Zurück zum Zitat Bae DK, Yoon KH, Song SJ, Shin MC, Noh JH (2008) Navigation versus Radiographic Measurements in the Open-Wedge High Tibial Osteotomy using Computer Assisted Surgery (CAS). J Korean Orthop Assoc 43:301–307CrossRef Bae DK, Yoon KH, Song SJ, Shin MC, Noh JH (2008) Navigation versus Radiographic Measurements in the Open-Wedge High Tibial Osteotomy using Computer Assisted Surgery (CAS). J Korean Orthop Assoc 43:301–307CrossRef
5.
Zurück zum Zitat Brouwer RW, Bierma-Zeinstra SM, van Koeveringe AJ, Verhaar JA (2005) Patellar height and the inclination of the tibial plateau after high tibial osteotomy. The open versus the closed-wedge technique. J Bone Joint Surg Br 87:1227–1232CrossRefPubMed Brouwer RW, Bierma-Zeinstra SM, van Koeveringe AJ, Verhaar JA (2005) Patellar height and the inclination of the tibial plateau after high tibial osteotomy. The open versus the closed-wedge technique. J Bone Joint Surg Br 87:1227–1232CrossRefPubMed
6.
Zurück zum Zitat Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 248–264 Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 248–264
7.
Zurück zum Zitat El-Azab H, Halawa A, Anetzberger H, Imhoff AB, Hinterwimmer S (2008) The effect of closed- and open-wedge high tibial osteotomy on tibial slope: a retrospective radiological review of 120 cases. J Bone Joint Surg Br 90:1193–1197CrossRefPubMed El-Azab H, Halawa A, Anetzberger H, Imhoff AB, Hinterwimmer S (2008) The effect of closed- and open-wedge high tibial osteotomy on tibial slope: a retrospective radiological review of 120 cases. J Bone Joint Surg Br 90:1193–1197CrossRefPubMed
8.
Zurück zum Zitat Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed
9.
Zurück zum Zitat Gebhard F, Krettek C, Hufner T, Grutzner PA, Stockle U, Imhoff AB, Lorenz S, Ljungqvist J, Keppler P (2010) Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy. Arch Orthop Trauma Surg 131:297–302CrossRefPubMedCentralPubMed Gebhard F, Krettek C, Hufner T, Grutzner PA, Stockle U, Imhoff AB, Lorenz S, Ljungqvist J, Keppler P (2010) Reliability of computer-assisted surgery as an intraoperative ruler in navigated high tibial osteotomy. Arch Orthop Trauma Surg 131:297–302CrossRefPubMedCentralPubMed
10.
Zurück zum Zitat Hankemeier S, Hufner T, Wang G, Kendoff D, Zeichen J, Zheng G, Krettek C (2006) Navigated open-wedge high tibial osteotomy: advantages and disadvantages compared to the conventional technique in a cadaver study. Knee Surg Sports Traumatol Arthrosc 14:917–921CrossRefPubMed Hankemeier S, Hufner T, Wang G, Kendoff D, Zeichen J, Zheng G, Krettek C (2006) Navigated open-wedge high tibial osteotomy: advantages and disadvantages compared to the conventional technique in a cadaver study. Knee Surg Sports Traumatol Arthrosc 14:917–921CrossRefPubMed
11.
Zurück zum Zitat Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69:332–354PubMed Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69:332–354PubMed
12.
Zurück zum Zitat Lee DH, Han SB, Oh KJ, Lee JS, Kwon JH, Kim JI, Patnaik S, Shetty GM, Nha KW (2012) The weight-bearing scanogram technique provides better coronal limb alignment than the navigation technique in open high tibial osteotomy. Knee. doi:10.1016/j.knee.2012.09.003 Lee DH, Han SB, Oh KJ, Lee JS, Kwon JH, Kim JI, Patnaik S, Shetty GM, Nha KW (2012) The weight-bearing scanogram technique provides better coronal limb alignment than the navigation technique in open high tibial osteotomy. Knee. doi:10.​1016/​j.​knee.​2012.​09.​003
13.
Zurück zum Zitat Lee DH, Nha KW, Park SJ, Han SB (2012) Preoperative and postoperative comparisons of navigation and radiologic limb alignment measurements after high tibial osteotomy. Arthroscopy 28:1842–1850CrossRefPubMed Lee DH, Nha KW, Park SJ, Han SB (2012) Preoperative and postoperative comparisons of navigation and radiologic limb alignment measurements after high tibial osteotomy. Arthroscopy 28:1842–1850CrossRefPubMed
14.
Zurück zum Zitat Lee YS, Lee BK, Lee SH, Park HG, Jun DS, Moon DH (2013) Effect of foot rotation on the mechanical axis and correlation between knee and whole leg radiographs. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-013-2419-x PubMedCentral Lee YS, Lee BK, Lee SH, Park HG, Jun DS, Moon DH (2013) Effect of foot rotation on the mechanical axis and correlation between knee and whole leg radiographs. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-013-2419-x PubMedCentral
15.
Zurück zum Zitat Marx RG, Grimm P, Lillemoe KA, Robertson CM, Ayeni OR, Lyman S, Bogner EA, Pavlov H (2011) Reliability of lower extremity alignment measurement using radiographs and PACS. Knee Surg Sports Traumatol Arthrosc 19:1693–1698CrossRefPubMed Marx RG, Grimm P, Lillemoe KA, Robertson CM, Ayeni OR, Lyman S, Bogner EA, Pavlov H (2011) Reliability of lower extremity alignment measurement using radiographs and PACS. Knee Surg Sports Traumatol Arthrosc 19:1693–1698CrossRefPubMed
16.
Zurück zum Zitat Miniaci A, Ballmer FT, Ballmer PM, Jakob RP (1989) Proximal tibial osteotomy. A new fixation device. Clin Orthop Relat Res 246:250–259PubMed Miniaci A, Ballmer FT, Ballmer PM, Jakob RP (1989) Proximal tibial osteotomy. A new fixation device. Clin Orthop Relat Res 246:250–259PubMed
17.
Zurück zum Zitat Pape D, Rupp S (2007) Preoperative Planning for High Tibial Osteotomies. Oper Tech Orthop 17:2–11CrossRef Pape D, Rupp S (2007) Preoperative Planning for High Tibial Osteotomies. Oper Tech Orthop 17:2–11CrossRef
18.
Zurück zum Zitat Schroter S, Gonser CE, Konstantinidis L, Helwig P, Albrecht D (2011) High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (position HTO plate) without bone substitute. Arthroscopy 27:644–652CrossRefPubMed Schroter S, Gonser CE, Konstantinidis L, Helwig P, Albrecht D (2011) High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (position HTO plate) without bone substitute. Arthroscopy 27:644–652CrossRefPubMed
19.
Zurück zum Zitat Schroter S, Gunzel J, Freude T, Ateschrang A, Stockle U, Albrecht D (2012) Precision in the planning of open wedge HTO. Z Orthop Unfall 150:368–373PubMed Schroter S, Gunzel J, Freude T, Ateschrang A, Stockle U, Albrecht D (2012) Precision in the planning of open wedge HTO. Z Orthop Unfall 150:368–373PubMed
20.
Zurück zum Zitat Schroter S, Ihle C, Mueller J, Lobenhoffer P, Stockle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy. Interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21:189–196CrossRefPubMed Schroter S, Ihle C, Mueller J, Lobenhoffer P, Stockle U, van Heerwaarden R (2013) Digital planning of high tibial osteotomy. Interrater reliability by using two different software. Knee Surg Sports Traumatol Arthrosc 21:189–196CrossRefPubMed
21.
Zurück zum Zitat Sled EA, Sheehy LM, Felson DT, Costigan PA, Lam M, Cooke TD (2011) Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program. Rheumatol Int 31:71–77CrossRefPubMedCentralPubMed Sled EA, Sheehy LM, Felson DT, Costigan PA, Lam M, Cooke TD (2011) Reliability of lower limb alignment measures using an established landmark-based method with a customized computer software program. Rheumatol Int 31:71–77CrossRefPubMedCentralPubMed
22.
Zurück zum Zitat Specogna AV, Birmingham TB, DaSilva JJ, Milner JS, Kerr J, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2004) Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg 17:203–210PubMed Specogna AV, Birmingham TB, DaSilva JJ, Milner JS, Kerr J, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR (2004) Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg 17:203–210PubMed
23.
Zurück zum Zitat Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia–early results in 92 cases. Injury 34(Suppl 2):B55–B62CrossRefPubMed Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia–early results in 92 cases. Injury 34(Suppl 2):B55–B62CrossRefPubMed
Metadaten
Titel
Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy
verfasst von
Yong Seuk Lee
Min Gyu Kim
Hae Won Byun
Sang Bum Kim
Jin Goo Kim
Publikationsdatum
01.03.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 3/2015
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-013-2700-z

Weitere Artikel der Ausgabe 3/2015

Knee Surgery, Sports Traumatology, Arthroscopy 3/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.