Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 11/2015

Open Access 01.11.2015 | Knee

Flat midsubstance of the anterior cruciate ligament with tibial “C”-shaped insertion site

verfasst von: Rainer Siebold, Peter Schuhmacher, Francis Fernandez, Robert Śmigielski, Christian Fink, Axel Brehmer, Joachim Kirsch

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 11/2015

Abstract

Purpose

This anatomical cadaver study was performed to investigate the flat appearance of the midsubstance shape of the anterior cruciate ligament (ACL) and its tibial “C”-shaped insertion site.

Methods

The ACL midsubstance and the tibial ACL insertion were dissected in 20 cadaveric knees (n = 6 fresh frozen and n = 14 paraffined). Magnifying spectacles were used for all dissections. Morphometric measurements were performed using callipers and on digital photographs.

Results

In all specimens, the midsubstance of the ACL was flat with a mean width of 9.9 mm, thickness of 3.9 mm and cross-sectional area of 38.7 mm2. The “direct” “C”-shaped tibial insertion runs from along the medial tibial spine to the anterior aspect of the lateral meniscus. The mean width (length) of the “C” was 12.6 mm, its thickness 3.3 mm and area 31.4 mm2. The centre of the “C” was the bony insertion of the anterior root of the lateral meniscus overlayed by fat and crossed by the ACL. No posterolateral (PL) inserting ACL fibres were found. Together with the larger “indirect” part (area 79.6 mm2), the “direct” one formed a “duck-foot”-shaped footprint.

Conclusion

The tibial ACL midsubstance and tibial “C”-shaped insertion are flat and are resembling a “ribbon”. The centre of the “C” is the bony insertion of the anterior root of the lateral meniscus. There are no central or PL inserting ACL fibres. Anatomical ACL reconstruction may therefore require a flat graft and a “C”-shaped tibial footprint reconstruction with an anteromedial bone tunnel for single bundle and an additional posteromedial bone tunnel for double bundle.
Hinweise
An erratum to this article can be found at http://​dx.​doi.​org/​10.​1007/​s00167-014-3230-z.

Introduction

A detailed understanding of the anterior cruciate ligament (ACL) is the basis for anatomical ACL reconstruction. Many cadaver studies have been performed to evaluate its midsubstance size and shape and its tibial insertion in the fossa of the area intercondylaris anterior.
Most authors described the tibial ACL insertion to be oval, with the insertion of the anteromedial (AM) bundle in the AM aspect with direct relation to the medial tibial spine. The insertion of the posterolateral (PL) bundle was reported to be in the PL aspect of the ACL footprint close to the lateral tibial spine in front of the posterior root of the lateral meniscus [7, 11, 17, 28, 30, 32, 33]. Most anatomical studies were performed using paraffined specimen. The tibial attachment was reported to be an average of 10–11 mm wide and 17–18 mm long [4, 11, 14, 15] with an average area of 136 ± 33 mm2 [17]. Arnoczky et al. [4] found that the ACL fans out anteriorly beneath the transverse meniscus ligament and that a few fascicles of the anterior aspect of the ACL may blend with the anterior attachment of the lateral meniscus as may do some posterior fibres of the ACL with the posterior attachment of the lateral meniscus.
Based on above descriptions, the tibial ACL insertion seemed to be well described. However, recent exciting studies reported the femoral “direct” insertion of the ACL to be long and flat [20, 23, 31] and the midsubstance to be of similar flat shape [23, 24]. In concordance, R. Smigielski (“The Ribbon Concept of the Anterior Cruciate Ligament”. Presentation at the ACL Study Group Meeting 2012, Jackson Hole, Wyoming, USA) recently reconfirmed the above findings and described the ACL to be a “ribbon” and the tibial ACL insertion to be “C”-shaped. A limitation of this study was that all dissections have been performed without magnification which might allow for a systematic error during dissections. On the other hand—when reconfirmed—a flat ACL morphology and “C”-shaped insertion would have a very important impact on graft shape and bone tunnel positioning in anatomical ACL reconstruction.
The purpose of this anatomical cadaver study was to investigate the macroscopic appearance of the midsubstance shape of the ACL and its bony tibial “C”-shaped insertion site in fresh frozen and paraffined knee specimen using magnifying lenses.

Materials and methods

Twenty human cadaveric knees (n = 6 fresh frozen and n = 14 paraffined) were used for this anatomical study. After a standard medial arthrotomy and removal of the patella, the ACL and PCL were exposed. The collateral ligaments and posterior soft tissue structures were kept for stability. An important key to the dissections was to first remove the synovial layer of the anterior horn of the lateral meniscus and to follow its shiny fibres down to its bony insertion in the central aspect of the area intercondylaris anterior. The overlaying fat pat between the insertion of the lateral meniscus and the crossing ACL was carefully removed. The midsubstance of the ACL was cleaned from surrounding synovial and fat tissue distally to its tibial insertion. In the paraffined specimen, the soft tissue structures had a yellow-like colour and were relatively stiff and hard to be discriminated by eyes. In contrast, the fresh frozen specimen was soft, and the ACL, fat pat and synovia kept their natural colours which made the dissections much easier. To ensure correct dissections, magnifying lenses were used for all steps of the dissections and all specimens (Carl Zeiss Jena, Germany).
The medial femoral condyle was removed to have better access to the ACL. Flexion of the knee was avoided for not to twist the ACL pretending an “oval” cross-sectional area and bundles (Fig. 1a–c). Instead, the knee was brought to full extension, which straightened the ACL fibres. Then, the ACL was temporary frozen with a standard ice spray for sports injuries and was carefully cut with a sharp blade at midsubstance. By freezing the ACL, it kept its shape. The frozen midsubstance was then “sliced” step by step and perpendicular to the longitudinal axis towards its tibial insertion. All dissections were performed by the first author, and all observations were reconfirmed by the co-authors, who watched and assisted the dissections. Morphometric measurements were performed directly at the specimen using callipers and on digital photographs.
Knees with severe osteoarthritic changes (Grades III and IV according to the Outerbridge classification [29] or damage to the ACL were excluded. Demographic data of the donors are presented in Table 1. The study was performed according to the ethical standards of the World Medical Association Declaration of Helsinki, Ethical Principles for Medical Research Involving Human Subjects.
Table 1
Demographic data of the donors displayed as median and range (min–max)
Gender
Side
Age (years)
Height (cm)
BMI (units)
Weight (kg)
10 female
13 right
78
166
22.8
63
7 male
7 left
(62–108)
(155–175)
(16.3–28.2)
(50–75)
3 N.A.
     

Statistical analysis

Median and range (min–max) were calculated for all donor characteristics. As the information on the smallest and largest anatomical measurements is very important for individual planning of anatomical ACL reconstructions, morphometric measurements were analysed descriptively. Therefore, all data of the morphometric measurements were tested for deviation from the normal distribution using Kolmogorov–Smirnov tests and Box-and-Whisker plots. For the Kolmogorov–Smirnov tests, a p value ≤0.05 was considered significant. Due to the normal distribution of all morphometric variables (p > 0.05) in this study, median, standard deviation (SD) and range (min–max) were calculated for all outcomes. As no group comparisons were conducted, a sample size calculation was not necessary. All analyses were conducted with SPSS 21 Statistics (IBM Corporation, Armonk, USA).

Results

The midsubstance of the ACL was flat and thin regardless of the conservation method of the specimen (paraffined or fresh frozen). When cut perpendicular to the long axis at midsubstance, it resembles a “ribbon”-like ligament with a mean width of 9.9 mm, thickness of 3.9 mm and cross-sectional area of 38.7 mm2 (Fig. 2a–c). Five millimetre close to the tibial ACL insertion, the mean width was 11.9 mm and thickness 3.5 mm.
The tibial ACL insertion is “C”-shaped from along the medial tibial spine to the anterior aspect of the anterior root of the lateral meniscus around a central and PL area (Fig. 3a–c). It has a mean width (length of the “C”) of 12.6 mm and thickness of 3.3 mm. The most anterior part of the “C” is a mean of 9.3 mm in the mediolateral direction, and the medial part of the “C” along the medial tibial spine is a mean of 11.4 mm in the anteroposterior direction. This corresponded to the mean anteroposterior (ap) width of 11.8 mm of the anterior horn of the lateral meniscus. The most posteromedial fibres of the “C”-shaped insertion site are a mean of 2.7 mm anterior to the tuberculum intercondylare mediale.
There are no central inserting ACL fibres, and there is no PL tibial ACL insertion. The posterior ACL fibres of the “C” are inserting medially along the medial tibial spine and were therefore named “posteromedial (PM) fibres” by the authors (Fig. 2a–c).
Details of the morphometric measurements, in particular the range with the minimal and the maximal values is displayed in Table 2.
Table 2
Morphometric measurements (mm) and cross-sectional area (mm2) of midsubstance and tibia ACL insertion displayed as mean ± standard deviation (SD), range (min–max) and median
Measurements of ACL
mean ± SD (range)
median
Width at midsubstance
9.9 ± 1.5 (7.0–12.7)
10.3
Thickness at midsubstance
3.9 ± 0.7 (2.8–4.9)
3.9
Cross-sectional area of midsubstance
38.7 ± 7.7 (20.3–51.5)
39.1
Width 5 mm proximal to tibial insertion
11.9 ± 1.1 (10.3–14.0)
11.7
Thickness 5 mm proximal to tibial insertion
3.5 ± 0.9 (2.3–5.9)
3.2
Width (length) of tibial “C”-shaped insertion
12.6 ± 2.3 (7.7–16.3)
12.7
Thickness of tibial “C”-shaped insertion
3.3 ± 0.4 (2.5–3.9)
3.3
Area of complete tibial insertion
110.9 ± 14.7 (80.1–133.1)
112.4
Area of direct “C”-shaped insertion
31.4 ± 7.2 (18.5-45.0)
30.4
Area of indirect insertion
79.6 ± 12.7 (53.7-107.7)
78.5
AP length of anterior horn lateral meniscus
11.8 ± 1.8 (8.4-15.5)
11.7
AP length of “C” along medial tibial spine
11.4 ± 2.0 (7.6-15.6)
11.3
Anterior (medial–lateral) of “C” (medial–lateral)
9.3 ± 1.6 (7.9-13.5)
8.6
Distance most posteromedial ACL insertion to tuberculum intercondylare mediale
2.7 ± 0.8 (0.8-3.8)
2.9

Lateral meniscus

The outer fibres of the anterior and posterior horn of the lateral meniscus blend with the “C”-shaped ACL insertion like a belt, and together, they form a complete “raindrop-like” ring structure (Figs. 2a–c, 3b, c). The centre of the “C” is the place of the wide bony insertion of the anterior root of the lateral meniscus (Fig. 3a–c). It is covered by fat tissue and overpassed by the flat ACL ligament from anterior (Figs. 1a–c, 2b).

Direct and indirect tibial ACL insertion

Macroscopically, the tibial insertion can be divided into a “direct” and “indirect” part. The “direct” insertion is the narrow but long “C”-shaped attachment of the midsubstance fibres with an area of 31.4 mm2, and the “indirect” part is the anteriorly and broader attachment of the “fan-like extension” fibres with an area of 79.6 mm2 (Figs. 3c, 4).
The “indirect” fibres extended from the direct insertion site anteriorly and broadly spread (“fan out”) towards the anterior rim of the tibial plateau. Both insertions together form a “duck-foot-like” bony ACL footprint with a combined area of 110.9 mm2. An overview on morphometry of the femoral, midsubstance and tibial ACL is given in Table 3.
Table 3
Overview on morphometry of the femoral, midsubstance and tibial ACL from the recent literature
 
Author
Width (mean)
Length (mean)
Insertion area
Femoral
Smigielski et al. (2012)
16.0 mm
3.5 mm
Direct female 52 mm2; male 55 mm2
Mochizuki et al. [24]
15.2 mm
4.7 mm
Direct 65 mm2
Iriuchishima et al. [19]
  
Direct 60.1 mm2
Mochizuki et al. [23]
  
Direct 50.8 mm2; indirect 91.4 mm2; complete 142.2 mm2
Sasaki et al. [31]
17.7 mm
5.0 mm
Direct 88 mm2
Midsubstance
Results of this study
11.9 mm
3.5 mm
37.0 mm2
Smigielski et al. (2012)
11.4 mm
3.4 mm
Female 33 mm2; male 38 mm2
Harner et al. [17]
  
40 mm2
Hashemi et al. [18]
  
46.8 mm2
Iriuchishima et al. [19]
  
46.9 mm2
Anderson et al. [3]
  
Female 36.1 mm2; male 44 mm2
Tibial
Results of this study
12.6 mm
3.3 mm
Direct 31.4 mm2; indirect 79.6 mm2; complete 110.9 mm2
Iriuchishima et al. [19]
  
Complete 123.5 mm2
Measurements document the flat appearance of the ACL including direct insertions on femur and tibia

ACL fibre bundles

The distal flat part of the ACL midsubstance consists of several small fibre bundles (Fig. 5a, b). It is impossible to clearly separate them macroscopically into an AM and PM bundle. From our observations, the appearance of macroscopic “bundles” may be created artificially by the twisted, flat ribbon-like structure of the ACL from femoral to tibial as well as the different direction of the tibial and femoral insertion site during flexion (Fig. 6a, b).

Discussion

The most important finding of this study is that the ACL midsubstance is a flat and ribbon-shaped ligament with a “C”-shaped tibial ACL insertion. The ACL fibres insert along the medial tibial spine to the anterior aspect of the root of the lateral meniscus in the area intercondylaris anterior. Only AM and PM inserting fibres are present, no PL ones. There are also no ACL fibres in the centre of the “C”, which is the place of the bony attachment of the anterior root of the lateral meniscus.
As seen by several authors and described by R. Smigielski (ACL Study Group Meeting 2012, USA), we observed a flat and thin appearance of the ACL midsubstance [3, 1719, 23, 24, 31]. In our specimen, the midsubstance had a mean width of 9.9 mm and thickness of only 3.9 mm which was similar to the dimensions of the “C”-shaped direct insertion site (12.6 mm versus 3.3 mm, respectively). Latter runs from along the medial tibial spine towards the anterior aspect of the anterior root of the lateral meniscus. The anteroposterior width of the lateral meniscus is very similar to the anteroposterior dimension of the tibial insertion site. The centre of the “C” is the bony insertion of the lateral meniscus, covered by fat and overpassed by the most distal fibres of the ACL from anteriorly. In contrast to previous investigators [9, 17, 22, 32, 34], we could not observe any central or PL inserting ACL fibres and no PL bundle. The posterior fibres were aligned along the medial tibial spine and were therefore named “posteromedial” (PM) fibres by the authors.
Like described for the femoral ACL insertion microscopically [20], the tibial insertion could macroscopically be divided into a “direct” and “indirect” part. The “direct” insertion was the 12.6-mm-long and 3.3-mm-thick “C”-shaped insertion of the midsubstance fibres, and the “indirect” part was the anteriorly and broader insertion of the “fan-like extension” fibres. These fibres extended from the midsubstance and broadly spread towards the anterior rim of the tibial plateau. Together, both parts formed a “duck-foot-like” bony footprint, which was described before [4]. A microscopic investigation is ongoing to support the macroscopic findings on the direct and indirect insertion.
The macroscopic separation of the ACL into bundles remains controversial. Many authors described the ACL midsubstance as a collection of individual fascicles that fan out over a broad flattened area with no histological evidence for two separate bundles [4, 8, 9, 21, 27, 35]. Our dissections reconfirm above findings, and even with magnification lenses, no separate AM and PL bundles could be distinguished. In contrast, many other authors differentiated between two [1, 5, 6, 1014, 16, 17, 22, 25, 30, 32, 33, 36] or even three separate ACL bundles [2, 26, 28]. Amis and Dawkins [2] reported that it was “sometimes difficult to separate the ACL into three discrete bundles ‘but’ in older specimens, the separate bundles were often obvious”. From our observations and as reported before [2, 14], the appearance of macroscopic “bundles” may be artificially created by the twisted, flat ribbon-like structure of the ACL from femoral to tibial and by the different alignment of the tibial and femoral bony attachment during flexion. When dissecting cadaver knees, preparation is usually done in flexion increasing the amount of twisting of the ACL and the impression of bundles.
Above findings would support a flat ligament and footprint reconstruction. The patella tendon and quadriceps tendon have a “natural” flat shape and can be used as is in a single-bundle technique. When using hamstrings, the tendon(s) have to be “aligned” in a flat shape. For that purpose, the double-bundle technique (flat alignment of hamstring reconstruction) is theoretically superior over the single-bundle technique (round alignment of hamstring reconstruction).
Anatomical footprint reconstruction is crucial. Mochizuki et al. [23] concluded for the femur that it is very difficult to reconstruct the fan-like indirect extension fibres by a bone tunnel; however, the midsubstance fibres (=“direct” insertion) of the ACL can be reconstructed. The same applies for the tibial side; however, the “C” shape of the tibial insertion makes anatomical footprint reconstruction very difficult. In SB ACL reconstruction, an AM bone tunnel may be favoured, and in DB, an AM and PM one.
A central or PL tibial bone tunnel placement should be avoided, as both are non-anatomical, may compromise biomechanics and can damage the insertion of the anterior root of the lateral meniscus. However, the most efficient technique for ACL reconstruction has yet to be found in prospectively designed clinical long-term studies.
A limitation of this study is that all dissections were performed by the first author. However, dissections were observed by the co-authors at any time, and magnifying lenses were used for all dissection steps. Morphometric measurements were performed using callipers and on digital photography.
Remains the question why our findings were different from previous ones? An important key is the conservation method of the specimen. In paraffined specimen, all soft tissue around the ACL has a yellow-like colour and is relatively stiff. In contrast, fresh frozen specimen is softer keeping the natural colours of the ACL, fat pat and synovia, which makes the discrimination and dissections of the structures much easier. The magnifying lenses have been extremely helpful, especially when dissecting the paraffined specimen. Another very important step was to freeze the ACL before cutting which preserved the shape of the ligament.

Conclusion

The tibial ACL midsubstance and the tibial “C”-shaped insertion are flat and are resembling a “ribbon”. The centre of the “C” is the bony attachment of the anterior root of the lateral meniscus. There are no central or PL inserting ACL fibres. Anatomical ACL reconstruction may therefore require a flat graft and a “C”-shaped tibial footprint reconstruction with an AM bone tunnel for single bundle and an additional PM bone tunnel for double bundle.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Adachi N, Ochi M, Uchio Y, Iwasa J, Kuriwaka M, Ito Y (2004) Reconstruction of the anterior cruciate ligament. Single- versus double-bundle multistranded hamstring tendons. J Bone Joint Surg Br 86(4):515–520PubMed Adachi N, Ochi M, Uchio Y, Iwasa J, Kuriwaka M, Ito Y (2004) Reconstruction of the anterior cruciate ligament. Single- versus double-bundle multistranded hamstring tendons. J Bone Joint Surg Br 86(4):515–520PubMed
2.
Zurück zum Zitat Amis AA, Dawkins GP (1991) Functional anatomy of the anterior cruciate ligament. Fibre bundle actions related to ligament replacements and injuries. J Bone Joint Surg Br 73(2):260–267PubMed Amis AA, Dawkins GP (1991) Functional anatomy of the anterior cruciate ligament. Fibre bundle actions related to ligament replacements and injuries. J Bone Joint Surg Br 73(2):260–267PubMed
3.
Zurück zum Zitat Anderson AF, Dome DC, Gautam S, Awh MH, Rennirt GW (2001) Correlation of anthropometric measurements, strength, anterior cruciate ligament size, and intercondylar notch characteristics to sex differences in anterior cruciate ligament tear rates. Am J Sports Med 29(1):58–66PubMed Anderson AF, Dome DC, Gautam S, Awh MH, Rennirt GW (2001) Correlation of anthropometric measurements, strength, anterior cruciate ligament size, and intercondylar notch characteristics to sex differences in anterior cruciate ligament tear rates. Am J Sports Med 29(1):58–66PubMed
4.
Zurück zum Zitat Arnoczky SP (1983) Anatomy of the anterior cruciate ligament. Clin Orthop Relat Res 172:19–25PubMed Arnoczky SP (1983) Anatomy of the anterior cruciate ligament. Clin Orthop Relat Res 172:19–25PubMed
5.
Zurück zum Zitat Baer GS, Ferretti M, Fu FH (2008) Anatomy of the ACL. In: Fu FH, Cohen SB (eds) Current concepts in ACL reconstruction. SLACK, Thorofare, pp 21–32 Baer GS, Ferretti M, Fu FH (2008) Anatomy of the ACL. In: Fu FH, Cohen SB (eds) Current concepts in ACL reconstruction. SLACK, Thorofare, pp 21–32
6.
Zurück zum Zitat Buoncristiani AM, Tjoumakaris FP, Starman JS, Ferretti M, Fu FH (2006) Anatomic double-bundle anterior cruciate ligament reconstruction. Arthroscopy 22(9):1000–1006CrossRefPubMed Buoncristiani AM, Tjoumakaris FP, Starman JS, Ferretti M, Fu FH (2006) Anatomic double-bundle anterior cruciate ligament reconstruction. Arthroscopy 22(9):1000–1006CrossRefPubMed
7.
Zurück zum Zitat Colombet P, Robinson J, Christel P, Franceschi JP, Djian P, Bellier G, Sbihi A (2006) Morphology of anterior cruciate ligament attachments for anatomic reconstruction: a cadaveric dissection and radiographic study. Arthroscopy 22(9):984–992CrossRefPubMed Colombet P, Robinson J, Christel P, Franceschi JP, Djian P, Bellier G, Sbihi A (2006) Morphology of anterior cruciate ligament attachments for anatomic reconstruction: a cadaveric dissection and radiographic study. Arthroscopy 22(9):984–992CrossRefPubMed
8.
Zurück zum Zitat Dargel J, Pohl P, Tzikaras P, Koebke J (2006) Morphometric side-to-side differences in human cruciate ligament insertions. Surg Radiol Anat 28(4):398–402CrossRefPubMed Dargel J, Pohl P, Tzikaras P, Koebke J (2006) Morphometric side-to-side differences in human cruciate ligament insertions. Surg Radiol Anat 28(4):398–402CrossRefPubMed
9.
Zurück zum Zitat Duthon VB, Barea C, Abrassart S, Fasel JH, Fritschy D, Menetrey J (2006) Anatomy of the anterior cruciate ligament. Knee Surg Sports Traumatol Arthrosc 14(3):204–213CrossRefPubMed Duthon VB, Barea C, Abrassart S, Fasel JH, Fritschy D, Menetrey J (2006) Anatomy of the anterior cruciate ligament. Knee Surg Sports Traumatol Arthrosc 14(3):204–213CrossRefPubMed
10.
Zurück zum Zitat Edwards A, Bull AM, Amis AA (2007) The attachments of the anteromedial and posterolateral fibre bundles of the anterior cruciate ligament: part 1: tibial attachment. Knee Surg Sports Traumatol Arthrosc 15(12):1414–1421CrossRefPubMed Edwards A, Bull AM, Amis AA (2007) The attachments of the anteromedial and posterolateral fibre bundles of the anterior cruciate ligament: part 1: tibial attachment. Knee Surg Sports Traumatol Arthrosc 15(12):1414–1421CrossRefPubMed
11.
Zurück zum Zitat Ferretti M, Doca D, Ingham SM, Cohen M, Fu FH (2012) Bony and soft tissue landmarks of the ACL tibial insertion site: an anatomical study. Knee Surg Sports Traumatol Arthrosc 20(1):62–68CrossRefPubMed Ferretti M, Doca D, Ingham SM, Cohen M, Fu FH (2012) Bony and soft tissue landmarks of the ACL tibial insertion site: an anatomical study. Knee Surg Sports Traumatol Arthrosc 20(1):62–68CrossRefPubMed
12.
Zurück zum Zitat Ferretti M, Levicoff EA, Macpherson TA, Moreland MS, Cohen M, Fu FH (2007) The fetal anterior cruciate ligament: an anatomic and histologic study. Arthroscopy 23(3):278–283CrossRefPubMed Ferretti M, Levicoff EA, Macpherson TA, Moreland MS, Cohen M, Fu FH (2007) The fetal anterior cruciate ligament: an anatomic and histologic study. Arthroscopy 23(3):278–283CrossRefPubMed
13.
Zurück zum Zitat Fu FH, Karlsson J (2010) A long journey to be anatomic. Knee Surg Sports Traumatol Arthrosc 18(9):1151–1153CrossRefPubMed Fu FH, Karlsson J (2010) A long journey to be anatomic. Knee Surg Sports Traumatol Arthrosc 18(9):1151–1153CrossRefPubMed
14.
Zurück zum Zitat Girgis FG, Marshall JL, Monajem A (1975) The cruciate ligaments of the knee joint. Anatomical, functional and experimental analysis. Clin Orthop Relat Res 106:216–231CrossRefPubMed Girgis FG, Marshall JL, Monajem A (1975) The cruciate ligaments of the knee joint. Anatomical, functional and experimental analysis. Clin Orthop Relat Res 106:216–231CrossRefPubMed
15.
Zurück zum Zitat Gray H, Gross CM (1973) Anatomy of the human body, 29th edn. Lea & Febiger, Philadelphia Gray H, Gross CM (1973) Anatomy of the human body, 29th edn. Lea & Febiger, Philadelphia
16.
Zurück zum Zitat Hamada M, Shino K, Horibe S, Mitsuoka T, Miyama T, Shiozaki Y, Mae T (2001) Single- versus bi-socket anterior cruciate ligament reconstruction using autogenous multiple-stranded hamstring tendons with EndoButton femoral fixation: a prospective study. Arthroscopy 17(8):801–807CrossRefPubMed Hamada M, Shino K, Horibe S, Mitsuoka T, Miyama T, Shiozaki Y, Mae T (2001) Single- versus bi-socket anterior cruciate ligament reconstruction using autogenous multiple-stranded hamstring tendons with EndoButton femoral fixation: a prospective study. Arthroscopy 17(8):801–807CrossRefPubMed
17.
Zurück zum Zitat Harner CD, Baek GH, Vogrin TM, Carlin GJ, Kashiwaguchi S, Woo SL (1999) Quantitative analysis of human cruciate ligament insertions. Arthroscopy 15(7):741–749CrossRefPubMed Harner CD, Baek GH, Vogrin TM, Carlin GJ, Kashiwaguchi S, Woo SL (1999) Quantitative analysis of human cruciate ligament insertions. Arthroscopy 15(7):741–749CrossRefPubMed
18.
Zurück zum Zitat Hashemi J, Mansouri H, Chandrashekar N, Slauterbeck JR, Hardy DM, Beynnon BD (2011) Age, sex, body anthropometry, and ACL size predict the structural properties of the human anterior cruciate ligament. J Orthop Res 29(7):993–1001CrossRefPubMed Hashemi J, Mansouri H, Chandrashekar N, Slauterbeck JR, Hardy DM, Beynnon BD (2011) Age, sex, body anthropometry, and ACL size predict the structural properties of the human anterior cruciate ligament. J Orthop Res 29(7):993–1001CrossRefPubMed
19.
Zurück zum Zitat Iriuchishima T, Yorifuji H, Aizawa S, Tajika Y, Murakami T, Fu FH (2012) Evaluation of ACL mid-substance cross-sectional area for reconstructed autograft selection. Knee Surg Sports Traumatol Arthrosc 22(1):207–213CrossRefPubMed Iriuchishima T, Yorifuji H, Aizawa S, Tajika Y, Murakami T, Fu FH (2012) Evaluation of ACL mid-substance cross-sectional area for reconstructed autograft selection. Knee Surg Sports Traumatol Arthrosc 22(1):207–213CrossRefPubMed
20.
Zurück zum Zitat Iwahashi T, Shino K, Nakata K, Otsubo H, Suzuki T, Amano H, Nakamura N (2010) Direct anterior cruciate ligament insertion to the femur assessed by histology and 3-dimensional volume-rendered computed tomography. Arthroscopy 26(9 Suppl):S13–S20CrossRefPubMed Iwahashi T, Shino K, Nakata K, Otsubo H, Suzuki T, Amano H, Nakamura N (2010) Direct anterior cruciate ligament insertion to the femur assessed by histology and 3-dimensional volume-rendered computed tomography. Arthroscopy 26(9 Suppl):S13–S20CrossRefPubMed
21.
Zurück zum Zitat Jacobsen K (1977) Osteoarthrosis following insufficiency of the cruciate ligaments in man: a clinical study. Acta Orthop Scand 48(5):520–526CrossRefPubMed Jacobsen K (1977) Osteoarthrosis following insufficiency of the cruciate ligaments in man: a clinical study. Acta Orthop Scand 48(5):520–526CrossRefPubMed
22.
Zurück zum Zitat Luites JW, Wymenga AB, Blankevoort L, Kooloos JG (2007) Description of the attachment geometry of the anteromedial and posterolateral bundles of the ACL from arthroscopic perspective for anatomical tunnel placement. Knee Surg Sports Traumatol Arthrosc 15(12):1422–1431PubMedCentralCrossRefPubMed Luites JW, Wymenga AB, Blankevoort L, Kooloos JG (2007) Description of the attachment geometry of the anteromedial and posterolateral bundles of the ACL from arthroscopic perspective for anatomical tunnel placement. Knee Surg Sports Traumatol Arthrosc 15(12):1422–1431PubMedCentralCrossRefPubMed
23.
Zurück zum Zitat Mochizuki T, Fujishiro H, Nimura A, Mahakkanukrauh P, Yasuda K, Muneta T, Akita K (2014) Anatomic and histologic analysis of the mid-substance and fan-like extension fibres of the anterior cruciate ligament during knee motion, with special reference to the femoral attachment. Knee Surg Sports Traumatol Arthrosc 22(2):336–344CrossRefPubMed Mochizuki T, Fujishiro H, Nimura A, Mahakkanukrauh P, Yasuda K, Muneta T, Akita K (2014) Anatomic and histologic analysis of the mid-substance and fan-like extension fibres of the anterior cruciate ligament during knee motion, with special reference to the femoral attachment. Knee Surg Sports Traumatol Arthrosc 22(2):336–344CrossRefPubMed
24.
Zurück zum Zitat Mochizuki T, Muneta T, Nagase T, Shirasawa S, Akita KI, Sekiya I (2006) Cadaveric knee observation study for describing anatomic femoral tunnel placement for two-bundle anterior cruciate ligament reconstruction. Arthroscopy 22(4):356–361CrossRefPubMed Mochizuki T, Muneta T, Nagase T, Shirasawa S, Akita KI, Sekiya I (2006) Cadaveric knee observation study for describing anatomic femoral tunnel placement for two-bundle anterior cruciate ligament reconstruction. Arthroscopy 22(4):356–361CrossRefPubMed
25.
Zurück zum Zitat Muneta T, Sekiya I, Yagishita K, Ogiuchi T, Yamamoto H, Shinomiya K (1999) Two-bundle reconstruction of the anterior cruciate ligament using semitendinosus tendon with endobuttons: operative technique and preliminary results. Arthroscopy 15(6):618–624CrossRefPubMed Muneta T, Sekiya I, Yagishita K, Ogiuchi T, Yamamoto H, Shinomiya K (1999) Two-bundle reconstruction of the anterior cruciate ligament using semitendinosus tendon with endobuttons: operative technique and preliminary results. Arthroscopy 15(6):618–624CrossRefPubMed
26.
Zurück zum Zitat Norwood LA, Cross MJ (1979) Anterior cruciate ligament: functional anatomy of its bundles in rotatory instabilities. Am J Sports Med 7(1):23–26CrossRefPubMed Norwood LA, Cross MJ (1979) Anterior cruciate ligament: functional anatomy of its bundles in rotatory instabilities. Am J Sports Med 7(1):23–26CrossRefPubMed
27.
Zurück zum Zitat Odensten M, Gillquist J (1985) Functional anatomy of the anterior cruciate ligament and a rationale for reconstruction. J Bone Joint Surg Am 67(2):257–262PubMed Odensten M, Gillquist J (1985) Functional anatomy of the anterior cruciate ligament and a rationale for reconstruction. J Bone Joint Surg Am 67(2):257–262PubMed
28.
Zurück zum Zitat Otsubo H, Shino K, Suzuki D, Kamiya T, Suzuki T, Watanabe K, Fujimiya M, Iwahashi T, Yamashita T (2012) The arrangement and the attachment areas of three ACL bundles. Knee Surg Sports Traumatol Arthrosc 20(1):127–134CrossRefPubMed Otsubo H, Shino K, Suzuki D, Kamiya T, Suzuki T, Watanabe K, Fujimiya M, Iwahashi T, Yamashita T (2012) The arrangement and the attachment areas of three ACL bundles. Knee Surg Sports Traumatol Arthrosc 20(1):127–134CrossRefPubMed
29.
Zurück zum Zitat Outerbridge RE (1961) The etiology of chondromalacia patellae. J Bone Joint Surg Br 43-B:752–757PubMed Outerbridge RE (1961) The etiology of chondromalacia patellae. J Bone Joint Surg Br 43-B:752–757PubMed
30.
Zurück zum Zitat Sadoghi P, Borbas P, Friesenbichler J, Scheipl S, Kastner N, Eberl R, Leithner A, Gruber G (2012) Evaluating the tibial and femoral insertion site of the anterior cruciate ligament using an objective coordinate system: a cadaver study. Injury 43(10):1771–1775CrossRefPubMed Sadoghi P, Borbas P, Friesenbichler J, Scheipl S, Kastner N, Eberl R, Leithner A, Gruber G (2012) Evaluating the tibial and femoral insertion site of the anterior cruciate ligament using an objective coordinate system: a cadaver study. Injury 43(10):1771–1775CrossRefPubMed
31.
Zurück zum Zitat Sasaki N, Ishibashi Y, Tsuda E, Yamamoto Y, Maeda S, Mizukami H, Toh S, Yagihashi S, Tonosaki Y (2012) The femoral insertion of the anterior cruciate ligament: discrepancy between macroscopic and histological observations. Arthroscopy 28(8):1135–1146CrossRefPubMed Sasaki N, Ishibashi Y, Tsuda E, Yamamoto Y, Maeda S, Mizukami H, Toh S, Yagihashi S, Tonosaki Y (2012) The femoral insertion of the anterior cruciate ligament: discrepancy between macroscopic and histological observations. Arthroscopy 28(8):1135–1146CrossRefPubMed
32.
Zurück zum Zitat Siebold R, Ellert T, Metz S, Metz J (2008) Tibial insertions of the anteromedial and posterolateral bundles of the anterior cruciate ligament: morphometry, arthroscopic landmarks, and orientation model for bone tunnel placement. Arthroscopy 24(2):154–161CrossRefPubMed Siebold R, Ellert T, Metz S, Metz J (2008) Tibial insertions of the anteromedial and posterolateral bundles of the anterior cruciate ligament: morphometry, arthroscopic landmarks, and orientation model for bone tunnel placement. Arthroscopy 24(2):154–161CrossRefPubMed
33.
Zurück zum Zitat Siebold R, Schuhmacher P (2012) Restoration of the tibial ACL footprint area and geometry using the modified insertion site table. Knee Surg Sports Traumatol Arthrosc 20(9):1845–1849CrossRefPubMed Siebold R, Schuhmacher P (2012) Restoration of the tibial ACL footprint area and geometry using the modified insertion site table. Knee Surg Sports Traumatol Arthrosc 20(9):1845–1849CrossRefPubMed
34.
Zurück zum Zitat Starman JS, Vanbeek C, Armfield DR, Sahasrabudhe A, Baker CL 3rd, Irrgang JJ, Fu FH (2007) Assessment of normal ACL double bundle anatomy in standard viewing planes by magnetic resonance imaging. Knee Surg Sports Traumatol Arthrosc 15(5):493–499CrossRefPubMed Starman JS, Vanbeek C, Armfield DR, Sahasrabudhe A, Baker CL 3rd, Irrgang JJ, Fu FH (2007) Assessment of normal ACL double bundle anatomy in standard viewing planes by magnetic resonance imaging. Knee Surg Sports Traumatol Arthrosc 15(5):493–499CrossRefPubMed
35.
Zurück zum Zitat Welsh RP (1980) Knee joint structure and function. Clin Orthop Relat Res 147:7–14PubMed Welsh RP (1980) Knee joint structure and function. Clin Orthop Relat Res 147:7–14PubMed
36.
Zurück zum Zitat Yasuda K, Kondo E, Ichiyama H, Kitamura N, Tanabe Y, Tohyama H, Minami A (2004) Anatomic reconstruction of the anteromedial and posterolateral bundles of the anterior cruciate ligament using hamstring tendon grafts. Arthroscopy 20(10):1015–1025CrossRefPubMed Yasuda K, Kondo E, Ichiyama H, Kitamura N, Tanabe Y, Tohyama H, Minami A (2004) Anatomic reconstruction of the anteromedial and posterolateral bundles of the anterior cruciate ligament using hamstring tendon grafts. Arthroscopy 20(10):1015–1025CrossRefPubMed
Metadaten
Titel
Flat midsubstance of the anterior cruciate ligament with tibial “C”-shaped insertion site
verfasst von
Rainer Siebold
Peter Schuhmacher
Francis Fernandez
Robert Śmigielski
Christian Fink
Axel Brehmer
Joachim Kirsch
Publikationsdatum
01.11.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 11/2015
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-014-3058-6

Weitere Artikel der Ausgabe 11/2015

Knee Surgery, Sports Traumatology, Arthroscopy 11/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.