Quantifying and Minimizing Radiation Exposure During Pediatric Cardiac Catheterization

verfasst von: R.M. Campbell, M.J. Strieper, P.A. Frias, G. Jeager, G. Balfour, L. Costello, K.M. Sullivan

Erschienen in: Pediatric Cardiology | Ausgabe 1/2005

Einloggen, um Zugang zu erhalten

Abstract

This study reports findings from evaluations of new technologies to measure radiation exposure during pediatric cardiac catheterization procedures. A strategy of pulsed fluoroscopy and low power settings resulted in significantly lower patient radiation exposure compared to conventional 60 frames/sec, high-power settings during fluoroscopy. During radiofrequency ablation procedures, thyroid and thoracic skin sites outside the direct fluoroscopic field received minimal radiation exposure. Intrathoracic radiation exposure was measured with the use of an esophageal dosimeter. In conclusion, strategies to reduce total radiation exposure should be employed, radiation dose should be measured, and assessment of radiation skin injury should be included in postcatheterization assessment.
Literatur
1.
Zurück zum Zitat Aufrichtig, R, Xue, P 1994Perpetual comparison of pulsed and continuous fluoroscopyMedical Phys21245256CrossRef Aufrichtig, R, Xue, P 1994Perpetual comparison of pulsed and continuous fluoroscopyMedical Phys21245256CrossRef
2.
Zurück zum Zitat Bower, M, Hintenlang, D 1999The characterization of a commercial MOSFET dosimeter system for use on diagnostic x-rayBr J Radiol72562568 Bower, M, Hintenlang, D 1999The characterization of a commercial MOSFET dosimeter system for use on diagnostic x-rayBr J Radiol72562568
3.
Zurück zum Zitat Calkins, H, Niklason, L, Sousa, J 1991Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connectionsCirculation8423762382 Calkins, H, Niklason, L, Sousa, J 1991Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connectionsCirculation8423762382
4.
Zurück zum Zitat Calkins, H, Rosenthal, L, Mahesh, M 2000Radiation exposure during radiofrequency catheter ablation proceduresHuang, SWilber, D eds. Radiofrequency Catheter Ablation of Cardiac Arrhythmias: Basic Concepts and Clinical Applications,2nd ednFuturaNew York793803 Calkins, H, Rosenthal, L, Mahesh, M 2000Radiation exposure during radiofrequency catheter ablation proceduresHuang, SWilber, D eds. Radiofrequency Catheter Ablation of Cardiac Arrhythmias: Basic Concepts and Clinical Applications,2nd ednFuturaNew York793803
5.
Zurück zum Zitat Fish, F, Steinberg, L, Macdonald, D 1997Radiation dosimetry during RFA in young patientsPACE201087 Fish, F, Steinberg, L, Macdonald, D 1997Radiation dosimetry during RFA in young patientsPACE201087
6.
Zurück zum Zitat Geise, R, Peters, N, Dunnigan, A, Milstein, S 1996Radiofrequency doses during pediatric radiofrequency catheter ablation proceduresPACE1916051611PubMed Geise, R, Peters, N, Dunnigan, A, Milstein, S 1996Radiofrequency doses during pediatric radiofrequency catheter ablation proceduresPACE1916051611PubMed
7.
Zurück zum Zitat Limacher, M, Douglas, P, Guido, G, et al. 1998Radiation safety in the practice of cardiologyJ Am Coll Cardiol31892912CrossRefPubMed Limacher, M, Douglas, P, Guido, G,  et al. 1998Radiation safety in the practice of cardiologyJ Am Coll Cardiol31892912CrossRefPubMed
8.
Zurück zum Zitat Lindsay, B, Eichling, J, Ambos, H 1992Radiation exposure to patients and medical personnel during radiofrequency catheter ablation for supraventricular tachycardiaAm J Cardiol72218223 Lindsay, B, Eichling, J, Ambos, H 1992Radiation exposure to patients and medical personnel during radiofrequency catheter ablation for supraventricular tachycardiaAm J Cardiol72218223
9.
Zurück zum Zitat Rosenthal, L, Mahesh, M, Beck, T, et al. 1998Predictors of fluoroscopy time and estimated radiation exposure during radiofrequency catheter ablation proceduresAm J Cardiol8245l458 Rosenthal, L, Mahesh, M, Beck, T,  et al. 1998Predictors of fluoroscopy time and estimated radiation exposure during radiofrequency catheter ablation proceduresAm J Cardiol8245l458
10.
Zurück zum Zitat Shrimpton, P, Wall, B, Jones, D, Fisher, E 1984The measurement of energy imparted to patients during diagnostic x-ray examinations using the diamentor exposure-area product meterPhys Med Biol2911991208CrossRefPubMed Shrimpton, P, Wall, B, Jones, D, Fisher, E 1984The measurement of energy imparted to patients during diagnostic x-ray examinations using the diamentor exposure-area product meterPhys Med Biol2911991208CrossRefPubMed
11.
Zurück zum Zitat U.S. Food, and Drug Administration1994Avoidance of Serious X-Ray Induced Skin Injuries to Patients during Fluoroscopy-Guided ProceduresU.S. Food and Drug AdministrationRockville, MD U.S. Food, and Drug Administration1994Avoidance of Serious X-Ray Induced Skin Injuries to Patients during Fluoroscopy-Guided ProceduresU.S. Food and Drug AdministrationRockville, MD
12.
Zurück zum Zitat Wu, J, Huang, T, Wu, D, Hsu, P, Weng, P 1991Radiation exposure of pediatric patients and physicians during cardiac catheterization and balloon pulmonary valvuloplastyAm J Cardiol68221225 Wu, J, Huang, T, Wu, D, Hsu, P, Weng, P 1991Radiation exposure of pediatric patients and physicians during cardiac catheterization and balloon pulmonary valvuloplastyAm J Cardiol68221225
Metadaten
Titel
Quantifying and Minimizing Radiation Exposure During Pediatric Cardiac Catheterization
verfasst von
R.M. Campbell
M.J. Strieper
P.A. Frias
G. Jeager
G. Balfour
L. Costello
K.M. Sullivan
Publikationsdatum
01.02.2005
Erschienen in
Pediatric Cardiology / Ausgabe 1/2005
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-004-0353-x

Weitere Artikel der Ausgabe 1/2005

Pediatric Cardiology 1/2005 Zur Ausgabe

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Triglyzeridsenker schützt nicht nur Hochrisikopatienten

10.05.2024 Hypercholesterinämie Nachrichten

Patienten mit Arteriosklerose-bedingten kardiovaskulären Erkrankungen, die trotz Statineinnahme zu hohe Triglyzeridspiegel haben, profitieren von einer Behandlung mit Icosapent-Ethyl, und zwar unabhängig vom individuellen Risikoprofil.

Gibt es eine Wende bei den bioresorbierbaren Gefäßstützen?

In den USA ist erstmals eine bioresorbierbare Gefäßstütze – auch Scaffold genannt – zur Rekanalisation infrapoplitealer Arterien bei schwerer PAVK zugelassen worden. Das markiert einen Wendepunkt in der Geschichte dieser speziellen Gefäßstützen.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.