Skip to main content
Erschienen in: Abdominal Radiology 3/2008

01.05.2008

Endoleak detection and classification after endovascular treatment of abdominal aortic aneurysm: value of CEUS over CTA

verfasst von: Gianpaolo Carrafiello, Chiara Recaldini, Domenico Laganà, Gabriele Piffaretti, Carlo Fugazzola

Erschienen in: Abdominal Radiology | Ausgabe 3/2008

Einloggen, um Zugang zu erhalten

Abstract

This paper focuses on the diagnostic value of CEUS in the detection and characterization of endoleaks in comparison with other imaging modalities, primary CDUS and CTA in the follow-up of endovascular abdominal aortic aneurysm repair. CEUS is an interesting alternative technique because of its limited costs and lack of exposure to ionizing radiation. However, CTA cannot currently be substituted because it enables a more precise evaluation of aneurysm morphologic changes, aneurysm sac diameter, graft anchorage and integrity. CEUS could be used along with CTA when the latter reveals the presence of endoleak, to provide a better characterization of it taking advantage of the angiodynamic behavior of the contrast agent that permits an easier visualization of the agent flow into the sac. It could also be indicated when aneurysm diameter increases and CTA did not show sac reperfusion or to monitor type II endoleaks reducing the use of CTA with consequent reduction of costs and exposure to radiation.
Literatur
1.
Zurück zum Zitat May J, White GH, Waugh RC, et al. (2001) Improved survival after endoluminal repair with second-generation prostheses compared with open repair in the treatment of abdominal aortic aneurysms: a 5-year concurrent comparison using life-table method. J Vasc Surg 33:S21–S26PubMedCrossRef May J, White GH, Waugh RC, et al. (2001) Improved survival after endoluminal repair with second-generation prostheses compared with open repair in the treatment of abdominal aortic aneurysms: a 5-year concurrent comparison using life-table method. J Vasc Surg 33:S21–S26PubMedCrossRef
2.
Zurück zum Zitat White GU, Yu W, May J, et al. (1997) Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms. J Endovasc Surg 4:152–155PubMedCrossRef White GU, Yu W, May J, et al. (1997) Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms. J Endovasc Surg 4:152–155PubMedCrossRef
3.
Zurück zum Zitat Veith FJ, Baum RA, Ohki T, et al. (2002) Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. J Vasc Surg 35:1029–1035PubMedCrossRef Veith FJ, Baum RA, Ohki T, et al. (2002) Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. J Vasc Surg 35:1029–1035PubMedCrossRef
4.
Zurück zum Zitat Baum R, Stavropoulos W, Fairman R, et al. (2003) Endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol 14:1111–1117PubMed Baum R, Stavropoulos W, Fairman R, et al. (2003) Endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol 14:1111–1117PubMed
5.
Zurück zum Zitat Pitton MB. (2006) Diagnosis and management of endoleaks after endovascular aneurysm repair: role of MRI. Abdom Imaging 31:339–346PubMedCrossRef Pitton MB. (2006) Diagnosis and management of endoleaks after endovascular aneurysm repair: role of MRI. Abdom Imaging 31:339–346PubMedCrossRef
6.
Zurück zum Zitat Dubenec SR, White GH, Pasenau J, et al. (2003) Endotension. A review of current views on pathophysiology and treatment. J Cardiovasc Surg 44(4):553–557 Dubenec SR, White GH, Pasenau J, et al. (2003) Endotension. A review of current views on pathophysiology and treatment. J Cardiovasc Surg 44(4):553–557
7.
Zurück zum Zitat Golzarian J, Dussaussois L, Abada HT, et al. (1998) Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR 171:329–331PubMed Golzarian J, Dussaussois L, Abada HT, et al. (1998) Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR 171:329–331PubMed
8.
Zurück zum Zitat Gorich J, Rilinger N, Sokiranski R, et al. (1999) Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography. Radiology 213:767–772PubMed Gorich J, Rilinger N, Sokiranski R, et al. (1999) Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography. Radiology 213:767–772PubMed
9.
Zurück zum Zitat Rozenblit A, Patlas M, Rosenbaum A, et al. (2003) Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisitions. Radiology 227: 426–433PubMedCrossRef Rozenblit A, Patlas M, Rosenbaum A, et al. (2003) Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisitions. Radiology 227: 426–433PubMedCrossRef
10.
Zurück zum Zitat Iezzi R, Cotroneo AR, Filippone A, et al. (2006) Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection? Radiology 241:915–921PubMedCrossRef Iezzi R, Cotroneo AR, Filippone A, et al. (2006) Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection? Radiology 241:915–921PubMedCrossRef
11.
Zurück zum Zitat Macari M, Chandarana H, Schmidt B, et al. (2006) Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? Radiology 241:908–914PubMedCrossRef Macari M, Chandarana H, Schmidt B, et al. (2006) Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? Radiology 241:908–914PubMedCrossRef
12.
Zurück zum Zitat Cejna M, Loewe C, Schoder M, et al. (2002) MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms. Eur Radiol 12:2443–2450PubMed Cejna M, Loewe C, Schoder M, et al. (2002) MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms. Eur Radiol 12:2443–2450PubMed
13.
Zurück zum Zitat Pitton MB, Schweitzer H, Herber S, et al. (2005) MRI versus spiral CT for endoleak detection following endovascular aneurysm repair. AJR 185:1275–1281PubMedCrossRef Pitton MB, Schweitzer H, Herber S, et al. (2005) MRI versus spiral CT for endoleak detection following endovascular aneurysm repair. AJR 185:1275–1281PubMedCrossRef
14.
Zurück zum Zitat Haulon S, Lions C, McFadden EP, et al. (2001) Prospective evaluation of magnetic resonance imaging after treatment of infrarenal aortic aneurysms. Eur J Vasc Endovasc Surg 22:62–69PubMedCrossRef Haulon S, Lions C, McFadden EP, et al. (2001) Prospective evaluation of magnetic resonance imaging after treatment of infrarenal aortic aneurysms. Eur J Vasc Endovasc Surg 22:62–69PubMedCrossRef
15.
Zurück zum Zitat Van der Laan MJ, Bakker CJG, Blankensteijn JD, et al. (2006) Dynamic CE-MRA for endoleak classification after endovascular aneurysm repair. Eur J Endovasc Surg 31:130–135CrossRef Van der Laan MJ, Bakker CJG, Blankensteijn JD, et al. (2006) Dynamic CE-MRA for endoleak classification after endovascular aneurysm repair. Eur J Endovasc Surg 31:130–135CrossRef
16.
Zurück zum Zitat McLafferty RB, McCrary BS, Mattos MA, et al. (2002) The use of Colour-flow duplex scan for the detection of endoleaks. J Vasc Surg 36:100–104PubMedCrossRef McLafferty RB, McCrary BS, Mattos MA, et al. (2002) The use of Colour-flow duplex scan for the detection of endoleaks. J Vasc Surg 36:100–104PubMedCrossRef
17.
Zurück zum Zitat Greenfield AL, Halpern EJ, Bonn J, et al. (2002) Application of duplex US for characterization of endoleaks in abdominal aortic stent grafts: report of five cases. Radiology 225:845–851PubMedCrossRef Greenfield AL, Halpern EJ, Bonn J, et al. (2002) Application of duplex US for characterization of endoleaks in abdominal aortic stent grafts: report of five cases. Radiology 225:845–851PubMedCrossRef
18.
Zurück zum Zitat Raman KG, Missing-Carroll N, Richardson T, et al. (2003) Flow–flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 38:645–651PubMedCrossRef Raman KG, Missing-Carroll N, Richardson T, et al. (2003) Flow–flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 38:645–651PubMedCrossRef
19.
Zurück zum Zitat D’Audiffret A, Desgranges P, Kobeiter DH, et al. (2001) Follow-up evaluation of endoluminally treated abdominal aneurysms with duplex ultrasonography: validation with computed tomography. J Vasc Surg 33:42–50PubMedCrossRef D’Audiffret A, Desgranges P, Kobeiter DH, et al. (2001) Follow-up evaluation of endoluminally treated abdominal aneurysms with duplex ultrasonography: validation with computed tomography. J Vasc Surg 33:42–50PubMedCrossRef
20.
Zurück zum Zitat Sato DT, Goff CD, Gregory RT, et al. (1998) Endoleak after aortic stent graft repair: diagnosis by Colour duplex ultrasound scan versus computed tomography scan. J Vasc Surg 28:657–663PubMedCrossRef Sato DT, Goff CD, Gregory RT, et al. (1998) Endoleak after aortic stent graft repair: diagnosis by Colour duplex ultrasound scan versus computed tomography scan. J Vasc Surg 28:657–663PubMedCrossRef
21.
Zurück zum Zitat Zannetti S, De Rango P, Parente B, et al. (2000) Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 19:531–535PubMedCrossRef Zannetti S, De Rango P, Parente B, et al. (2000) Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 19:531–535PubMedCrossRef
22.
Zurück zum Zitat Pages S, Favre JP, Cerisier A, et al. (2001) Comparison of Colour duplex ultrasound and computed tomography scan for surveillance after aortic endografting. Ann Vasc Surg 15:155–162PubMedCrossRef Pages S, Favre JP, Cerisier A, et al. (2001) Comparison of Colour duplex ultrasound and computed tomography scan for surveillance after aortic endografting. Ann Vasc Surg 15:155–162PubMedCrossRef
23.
Zurück zum Zitat Wolf YG, Johnson BL, Hill BR, et al. (2000) Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J Vasc Surg 32:1142–1148PubMedCrossRef Wolf YG, Johnson BL, Hill BR, et al. (2000) Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J Vasc Surg 32:1142–1148PubMedCrossRef
24.
Zurück zum Zitat Heilberger P, Schunn C, Ritter W, et al. (1997) Postoperative Colour flow duplex scanning in aortic endograft. J Endovasc Surg 4:262–271PubMedCrossRef Heilberger P, Schunn C, Ritter W, et al. (1997) Postoperative Colour flow duplex scanning in aortic endograft. J Endovasc Surg 4:262–271PubMedCrossRef
25.
Zurück zum Zitat Sun Z (2006) Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm. J Vasc Interv Radiol 17:759–764PubMedCrossRef Sun Z (2006) Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm. J Vasc Interv Radiol 17:759–764PubMedCrossRef
26.
Zurück zum Zitat McWilliams RG, Martin J, White D, et al. (1999) Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair. J Vasc Interv Radiol 10:1107–1114PubMedCrossRef McWilliams RG, Martin J, White D, et al. (1999) Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair. J Vasc Interv Radiol 10:1107–1114PubMedCrossRef
27.
Zurück zum Zitat McWilliams RG, Martin J, White D, et al. (2002) Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography. J Endovasc Ther 9:170–179PubMedCrossRef McWilliams RG, Martin J, White D, et al. (2002) Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography. J Endovasc Ther 9:170–179PubMedCrossRef
28.
Zurück zum Zitat Giannoni MF, Palombo G, Sbarigia E, et al. (2003) Contrast-enhanced ultrasound imaging for aortic stent-graft surveillance. J Endovasc Ther 10:208–217PubMedCrossRef Giannoni MF, Palombo G, Sbarigia E, et al. (2003) Contrast-enhanced ultrasound imaging for aortic stent-graft surveillance. J Endovasc Ther 10:208–217PubMedCrossRef
29.
Zurück zum Zitat Napoli V, Bargellini I, Sardella S, et al. (2004) Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 233:217–225PubMedCrossRef Napoli V, Bargellini I, Sardella S, et al. (2004) Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 233:217–225PubMedCrossRef
30.
Zurück zum Zitat Carrafiello G, Laganà D, Recaldini C, et al. (2006) Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: preliminary experience. Cardiovasc Intervent Radiol 29:969–974PubMedCrossRef Carrafiello G, Laganà D, Recaldini C, et al. (2006) Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: preliminary experience. Cardiovasc Intervent Radiol 29:969–974PubMedCrossRef
31.
Zurück zum Zitat Bendick PJ, Bove PG, Long GW, et al. (2003) Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts. J Vasc Surg 37:381–385PubMedCrossRef Bendick PJ, Bove PG, Long GW, et al. (2003) Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts. J Vasc Surg 37:381–385PubMedCrossRef
32.
Zurück zum Zitat Henao EA, Hodge MD, Felkai DD, et al. (2006) Contrast-enhanced duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique. J Vasc Surg 43:259–264PubMedCrossRef Henao EA, Hodge MD, Felkai DD, et al. (2006) Contrast-enhanced duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique. J Vasc Surg 43:259–264PubMedCrossRef
33.
Zurück zum Zitat Bargellini I, Napoli V, Petruzzi P, et al. (2005) Type II lumbar endoleaks: hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair. J Vasc Surg 41:10–18PubMedCrossRef Bargellini I, Napoli V, Petruzzi P, et al. (2005) Type II lumbar endoleaks: hemodynamic differentiation by contrast-enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair. J Vasc Surg 41:10–18PubMedCrossRef
34.
Zurück zum Zitat Dill-Macky M (2006) Aortic endografts: detecting endoleaks using contrast-enhanced ultrasound. Ultrasound Q 22:49–52PubMed Dill-Macky M (2006) Aortic endografts: detecting endoleaks using contrast-enhanced ultrasound. Ultrasound Q 22:49–52PubMed
35.
Zurück zum Zitat Lencioni R (2006) Enhancing the role of ultrasound with contrast agents. Springer, Milano pp 119–165 Lencioni R (2006) Enhancing the role of ultrasound with contrast agents. Springer, Milano pp 119–165
36.
Zurück zum Zitat Thurnher S, Cejna M (2002) Imaging of aortic stent-grafts and endoleaks. Radiol Clin N Am 40:799–833PubMedCrossRef Thurnher S, Cejna M (2002) Imaging of aortic stent-grafts and endoleaks. Radiol Clin N Am 40:799–833PubMedCrossRef
37.
Zurück zum Zitat Ellozy SH, Carroccio A, Lookstein RA, et al. (2004) First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. J Vasc Surg 40: 405–412PubMedCrossRef Ellozy SH, Carroccio A, Lookstein RA, et al. (2004) First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. J Vasc Surg 40: 405–412PubMedCrossRef
38.
Zurück zum Zitat Ohki T, Ouriel K, Galvagni Silvera P, et al. (2007) Initial results of wireless pressure sensing for endovascular aneurysm repair: the apex trial—acute pressure measurement to confirm aneurysm sac exclusion. J Vasc Surg 45:236–242PubMedCrossRef Ohki T, Ouriel K, Galvagni Silvera P, et al. (2007) Initial results of wireless pressure sensing for endovascular aneurysm repair: the apex trial—acute pressure measurement to confirm aneurysm sac exclusion. J Vasc Surg 45:236–242PubMedCrossRef
Metadaten
Titel
Endoleak detection and classification after endovascular treatment of abdominal aortic aneurysm: value of CEUS over CTA
verfasst von
Gianpaolo Carrafiello
Chiara Recaldini
Domenico Laganà
Gabriele Piffaretti
Carlo Fugazzola
Publikationsdatum
01.05.2008
Verlag
Springer-Verlag
Erschienen in
Abdominal Radiology / Ausgabe 3/2008
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-007-9268-3

Weitere Artikel der Ausgabe 3/2008

Abdominal Radiology 3/2008 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.