Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?

verfasst von: Jean Yves Lazennec, Quentin Chometon, Dominique Folinais, Christopher B. Robbins, Aidin Eslam Pour

Erschienen in: International Orthopaedics | Ausgabe 5/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

Coronal malalignment of the lower extremity is closely related to the onset and progression of osteoarthritis. Restoring satisfactory alignment after tibial osteotomy improves the long-term success of this conservative surgery. The purpose of our study was to determine (1) if there is a difference between two-dimensional (2D) and 3D measurements of the hip-knee-ankle (HKA) angle between the mechanical axes of the femur and the tibia, (2) which parameter most affects 2D–3D HKA measurement, and (3) the percentage of patients who are at risk of error in HKA measurement.

Methods

We reviewed imaging studies of the consecutive patients referred to us for hip or knee pain between June and October 2013. Patients with previous pelvis or lower extremity surgery were excluded.

Results

In 51 % (95/186) of lower extremities examined, the 3D method showed more valgus than the 2D method, and in 49 % (91/186), the 3D method showed more varus. In 12 % of extremities (23/186), the knee varus or valgus alignment was completely opposite in 3D images compared to 2D images. Having more than 7° of flexum/recurvatum alignment increased error in 2D HKA measurement by 5.7°. This was calculated to be 0.15° per 1° increase in femoral torsion and 0.05° per 1° increase in tibial torsion. Approximately 20 % of patients might be at risk of error in HKA angle measurement in 2D imaging studies.

Conclusions

Orthopaedic surgeons should assess lower extremity alignment in standing position, with enough exposure of the extremity to find severe alignment or rotational deformities, and consider advanced 3D images of those patients who have them. Otherwise, HKA angle can be measured with good accuracy with 2D techniques.

Level of Evidence

Level-III diagnostic.
Literatur
1.
Zurück zum Zitat Brouwer GM, van Tol AW, Bergink AP, Belo JN, Bernsen RM, Reijman M, Pols HA, Bierma-Zeinstra SM (2007) Association between valgus and varus alignment and the development and progression of radiographic osteoarthritis of the knee. Arthritis Rheum 56:1204–1211. doi:10.1002/art.22515 CrossRefPubMed Brouwer GM, van Tol AW, Bergink AP, Belo JN, Bernsen RM, Reijman M, Pols HA, Bierma-Zeinstra SM (2007) Association between valgus and varus alignment and the development and progression of radiographic osteoarthritis of the knee. Arthritis Rheum 56:1204–1211. doi:10.​1002/​art.​22515 CrossRefPubMed
2.
Zurück zum Zitat Cerejo R, Dunlop DD, Cahue S, Channin D, Song J, Sharma L (2002) The influence of alignment on risk of knee osteoarthritis progression according to baseline stage of disease. Arthritis Rheum 46:2632–2636. doi:10.1002/art.10530 CrossRefPubMed Cerejo R, Dunlop DD, Cahue S, Channin D, Song J, Sharma L (2002) The influence of alignment on risk of knee osteoarthritis progression according to baseline stage of disease. Arthritis Rheum 46:2632–2636. doi:10.​1002/​art.​10530 CrossRefPubMed
3.
Zurück zum Zitat Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286:188–195CrossRefPubMed Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286:188–195CrossRefPubMed
5.
Zurück zum Zitat Suero EM, Sabbagh Y, Westphal R, Hawi N, Citak M, Wahl FM, Krettek C, Liodakis E (2015) Effect of medial opening wedge high tibial osteotomy on intraarticular knee and ankle contact pressures. J Orthop Res 33:598–604. doi:10.1002/jor.22793 CrossRefPubMed Suero EM, Sabbagh Y, Westphal R, Hawi N, Citak M, Wahl FM, Krettek C, Liodakis E (2015) Effect of medial opening wedge high tibial osteotomy on intraarticular knee and ankle contact pressures. J Orthop Res 33:598–604. doi:10.​1002/​jor.​22793 CrossRefPubMed
7.
Zurück zum Zitat Gaillard R, Cerciello S, Lustig S, Servien E, Neyret P (2016) Risk factors for tibial implant malpositioning in total knee arthrosplasty-consecutive series of one thousand, four hundred and seventeen cases. Int Orthop. doi:10.1007/s00264-016-3307-z Gaillard R, Cerciello S, Lustig S, Servien E, Neyret P (2016) Risk factors for tibial implant malpositioning in total knee arthrosplasty-consecutive series of one thousand, four hundred and seventeen cases. Int Orthop. doi:10.​1007/​s00264-016-3307-z
8.
Zurück zum Zitat Jenny JY, Tavan A, Jenny G, Kehr P (1998) Long-term survival rate of tibial osteotomies for valgus gonarthrosis. Rev Chir Orthop Reparatrice Appar Mot 84:350–357PubMed Jenny JY, Tavan A, Jenny G, Kehr P (1998) Long-term survival rate of tibial osteotomies for valgus gonarthrosis. Rev Chir Orthop Reparatrice Appar Mot 84:350–357PubMed
12.
16.
Zurück zum Zitat Kim YH, Park JW, Kim JS, Park SD (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop 38:379–385. doi:10.1007/s00264-013-2097-9 CrossRefPubMed Kim YH, Park JW, Kim JS, Park SD (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop 38:379–385. doi:10.​1007/​s00264-013-2097-9 CrossRefPubMed
18.
Zurück zum Zitat Sailer J, Scharitzer M, Peloschek P, Giurea A, Imhof H, Grampp S (2005) Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs. Eur Radiol 15:170–173. doi:10.1007/s00330-004-2436-8 CrossRefPubMed Sailer J, Scharitzer M, Peloschek P, Giurea A, Imhof H, Grampp S (2005) Quantification of axial alignment of the lower extremity on conventional and digital total leg radiographs. Eur Radiol 15:170–173. doi:10.​1007/​s00330-004-2436-8 CrossRefPubMed
20.
Zurück zum Zitat Thelen P, Delin C, Folinais D, Radier C (2012) Evaluation of a new low-dose biplanar system to assess lower-limb alignment in 3D: a phantom study. Skelet Radiol 41:1287–1293. doi:10.1007/s00256-012-1438-x CrossRef Thelen P, Delin C, Folinais D, Radier C (2012) Evaluation of a new low-dose biplanar system to assess lower-limb alignment in 3D: a phantom study. Skelet Radiol 41:1287–1293. doi:10.​1007/​s00256-012-1438-x CrossRef
22.
Zurück zum Zitat Chaibi Y, Cresson T, Aubert B, Hausselle J, Neyret P, Hauger O, de Guise JA, Skalli W (2012) Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Engin 15:457–466. doi:10.1080/10255842.2010.540758 CrossRefPubMed Chaibi Y, Cresson T, Aubert B, Hausselle J, Neyret P, Hauger O, de Guise JA, Skalli W (2012) Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Engin 15:457–466. doi:10.​1080/​10255842.​2010.​540758 CrossRefPubMed
24.
Zurück zum Zitat Cooke TD, Sled EA, Scudamore RA (2007) Frontal plane knee alignment: a call for standardized measurement. J Rheumatol 34:1796–1801PubMed Cooke TD, Sled EA, Scudamore RA (2007) Frontal plane knee alignment: a call for standardized measurement. J Rheumatol 34:1796–1801PubMed
25.
27.
Zurück zum Zitat Kanungo T, Mount DM, Netanyahu NS, Piako CD, Silverman R, Wu A (2000) The analysis of a simple k-means clustering algorithm. In: ACM Symposium on Computational Geometry, 2000. ACM Press, pp 100–109 Kanungo T, Mount DM, Netanyahu NS, Piako CD, Silverman R, Wu A (2000) The analysis of a simple k-means clustering algorithm. In: ACM Symposium on Computational Geometry, 2000. ACM Press, pp 100–109
28.
Zurück zum Zitat Swanson KE, Stocks GW, Warren PD, Hazel MR, Janssen HF (2000) Does axial limb rotation affect the alignment measurements in deformed limbs? Clin Orthop Relat Res 246–252 Swanson KE, Stocks GW, Warren PD, Hazel MR, Janssen HF (2000) Does axial limb rotation affect the alignment measurements in deformed limbs? Clin Orthop Relat Res 246–252
29.
Zurück zum Zitat Zampogna B, Vasta S, Amendola A, Uribe-Echevarria Marbach B, Gao Y, Papalia R, Denaro V (2015) Assessing lower limb alignment: comparison of standard knee xray vs long leg view. Iowa Orthop J 35:49–54PubMedPubMedCentral Zampogna B, Vasta S, Amendola A, Uribe-Echevarria Marbach B, Gao Y, Papalia R, Denaro V (2015) Assessing lower limb alignment: comparison of standard knee xray vs long leg view. Iowa Orthop J 35:49–54PubMedPubMedCentral
31.
Zurück zum Zitat Sugama R, Minoda Y, Kobayashi A, Iwaki H, Ikebuchi M, Hashimoto Y, Takaoka K, Nakamura H (2011) Sagittal alignment of the lower extremity while standing in female. Knee Surg Sports Traumatol Arthrosc 19:74–79. doi:10.1007/s00167-010-1137-x CrossRefPubMed Sugama R, Minoda Y, Kobayashi A, Iwaki H, Ikebuchi M, Hashimoto Y, Takaoka K, Nakamura H (2011) Sagittal alignment of the lower extremity while standing in female. Knee Surg Sports Traumatol Arthrosc 19:74–79. doi:10.​1007/​s00167-010-1137-x CrossRefPubMed
32.
Zurück zum Zitat Brouwer RW, Jakma TS, Brouwer KH, Verhaar JA (2007) Pitfalls in determining knee alignment: a radiographic cadaver study. J Knee Surg 20:210–215PubMed Brouwer RW, Jakma TS, Brouwer KH, Verhaar JA (2007) Pitfalls in determining knee alignment: a radiographic cadaver study. J Knee Surg 20:210–215PubMed
Metadaten
Titel
Are advanced three-dimensional imaging studies always needed to measure the coronal knee alignment of the lower extremity?
verfasst von
Jean Yves Lazennec
Quentin Chometon
Dominique Folinais
Christopher B. Robbins
Aidin Eslam Pour
Publikationsdatum
14.11.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 5/2017
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3340-y

Weitere Artikel der Ausgabe 5/2017

International Orthopaedics 5/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.