Skip to main content
Erschienen in: Aesthetic Plastic Surgery 1/2008

01.01.2008 | Original Article

Aesthetic Treatment of Pectus Excavatum: A New Endoscopic Technique Using a Porous Polyethylene Implant

verfasst von: Simone Grappolini, Paolo M. Fanzio, Pierluca G. C. D’Addetta, Alberto Todde, Maurizio Infante

Erschienen in: Aesthetic Plastic Surgery | Ausgabe 1/2008

Einloggen, um Zugang zu erhalten

Abstract

Background

Pectus excavatum is the most frequent malformation of the rib cage. Functional aspects associated with this malformation often are absent even in adults not involved in competitive sports activities. Overall, these patients often live with extreme psychological discomfort when the malformations are minor. Traditionally, the correction of these malformations has been geared toward interventions that modify the architecture of the rib cage. However, all these interventions, even the most recent, involve considerably invasive major surgery. In fact, optimal results are not always achieved with corrective surgery using the insertion of silicone prosthesis, and patients often experience complications.

Methods

To correct intermediate and modest pectus excavatum in a stable manner and with the least amount of invasiveness, the authors developed a camouflage technique that uses porous prostheses made from high-density linear polyethylene. This material is generally used for reconstruction of the brain case. Between February 2001 and March 2006, in the I Unit of Plastic Surgery of the authors’ Institute, 11 adult pectus excavatum patients with no previous cardiorespiratory symptoms underwent the authors’ surgical technique. The average patient age was 29 years.

Results

Surgical repair was successful in all cases, and the average hospital stay was short. There were no complications during the follow-up period. The described approach repairs nonfunctional pectus excavatum in the adult with satisfying aesthetic and stable results, short hospital stay, and high patient popularity ratings.

Conclusions

The best therapeutic option for pectus excavatum, especially with intermediate or moderate severity, is still controversial: thoracic surgery or camouflage surgery with implant? Trying to address those issues we propose a new technique by a multidisciplinary, not aggressive approach using a high density linear polyethylene implant and Omentus flap and the early analysis of our data.
Literatur
1.
Zurück zum Zitat Barauskas V (2003) Indications for the surgical treatment of the funnel chest. Medicina (Kaunas) 39:555–561 Barauskas V (2003) Indications for the surgical treatment of the funnel chest. Medicina (Kaunas) 39:555–561
2.
Zurück zum Zitat Chavoin JP, Dahan M, Grolleau JL, Soubirac L, Wagner A, Foucras L, Darbas D, Pomar P (2003) Funnel chest: Filling technique with deep custom made implant. Ann Chir Plast Esthet 48(2):67–76PubMedCrossRef Chavoin JP, Dahan M, Grolleau JL, Soubirac L, Wagner A, Foucras L, Darbas D, Pomar P (2003) Funnel chest: Filling technique with deep custom made implant. Ann Chir Plast Esthet 48(2):67–76PubMedCrossRef
3.
Zurück zum Zitat Choi JC, Iwamoto MA, Bstandig S, Rubin PAD, Shore JW (1999) MEDPOR Motility Coupling Post: A rabbit model. Ophthal Plast Reconstr Surg 15:190–200PubMedCrossRef Choi JC, Iwamoto MA, Bstandig S, Rubin PAD, Shore JW (1999) MEDPOR Motility Coupling Post: A rabbit model. Ophthal Plast Reconstr Surg 15:190–200PubMedCrossRef
4.
Zurück zum Zitat Coln D, Gunning T, Ramsay M, Swygert T, Vera R (2002) Early experience with the Nuss minimally invasive correction of pectus excavatum in adults. World J Surg 26:1217–1221, Epub 2002 September 6PubMedCrossRef Coln D, Gunning T, Ramsay M, Swygert T, Vera R (2002) Early experience with the Nuss minimally invasive correction of pectus excavatum in adults. World J Surg 26:1217–1221, Epub 2002 September 6PubMedCrossRef
5.
Zurück zum Zitat Einsiedel E, Clausner A (1999) Funnel chest: Psychological and psychosomatic aspects in children, youngsters, and young adults. J Cardiovasc Surg (Torino) 40:733–736 Einsiedel E, Clausner A (1999) Funnel chest: Psychological and psychosomatic aspects in children, youngsters, and young adults. J Cardiovasc Surg (Torino) 40:733–736
6.
Zurück zum Zitat Erbella J Jr, Behmand R, Cederna PS (2001) Endoscopically assisted pectus excavatum repair. Surg Laparosc Endosc Percutan Tech 11:213–216PubMedCrossRef Erbella J Jr, Behmand R, Cederna PS (2001) Endoscopically assisted pectus excavatum repair. Surg Laparosc Endosc Percutan Tech 11:213–216PubMedCrossRef
7.
Zurück zum Zitat Fonkalsrud EW, Beanes S, Hebra A, Adamson W, Tagge E (2002) Comparison of minimally invasive and modified Ravitch pectus excavatum repair. J Pediatr Surg 37:413–417PubMedCrossRef Fonkalsrud EW, Beanes S, Hebra A, Adamson W, Tagge E (2002) Comparison of minimally invasive and modified Ravitch pectus excavatum repair. J Pediatr Surg 37:413–417PubMedCrossRef
8.
Zurück zum Zitat Freeman BS (1976) Proplast, a porous implant for contour restoration (no abstract available). Br J Plast Surg 29:158–164PubMedCrossRef Freeman BS (1976) Proplast, a porous implant for contour restoration (no abstract available). Br J Plast Surg 29:158–164PubMedCrossRef
9.
Zurück zum Zitat Haller JA Jr, Scherer LR, Turner CS, Colombani PM (1989) Evolving management of pectus excavatum based on a single institutional experience of 664 patients. Ann Surg 209:578–582, discussion 582–583PubMedCrossRef Haller JA Jr, Scherer LR, Turner CS, Colombani PM (1989) Evolving management of pectus excavatum based on a single institutional experience of 664 patients. Ann Surg 209:578–582, discussion 582–583PubMedCrossRef
10.
Zurück zum Zitat Hodgkinson DJ (1997) Chest wall implants: Their use for pectus excavatum, pectoralis muscle tears, Poland’s syndrome, and muscular insufficiency. Aesth Plast Surg 21:7–15CrossRef Hodgkinson DJ (1997) Chest wall implants: Their use for pectus excavatum, pectoralis muscle tears, Poland’s syndrome, and muscular insufficiency. Aesth Plast Surg 21:7–15CrossRef
11.
Zurück zum Zitat Horch RE, Stoelben E, Carbon R, Sultan AA, Bach AD, Kneser U (2006) Pectus excavatum breast and chest deformity: Indications for aesthetic plastic surgery versus thoracic surgery in a multicenter experience. Aesth Plast Surg 30:403–411CrossRef Horch RE, Stoelben E, Carbon R, Sultan AA, Bach AD, Kneser U (2006) Pectus excavatum breast and chest deformity: Indications for aesthetic plastic surgery versus thoracic surgery in a multicenter experience. Aesth Plast Surg 30:403–411CrossRef
12.
Zurück zum Zitat Hougaard G, Svensson H, Holmqvist KG (1995) Casting the implant for reconstruction of pectus excavatum. Scand J Plast Reconstr Surg Hand Surg 29:227–231PubMedCrossRef Hougaard G, Svensson H, Holmqvist KG (1995) Casting the implant for reconstruction of pectus excavatum. Scand J Plast Reconstr Surg Hand Surg 29:227–231PubMedCrossRef
13.
Zurück zum Zitat Johnson PE (1996) Refining silicone implant correction of pectus excavatum through computed tomography. Plast Reconstr Surg 97:445–449PubMedCrossRef Johnson PE (1996) Refining silicone implant correction of pectus excavatum through computed tomography. Plast Reconstr Surg 97:445–449PubMedCrossRef
14.
Zurück zum Zitat Lemperle G, Exner K (1983) Treatment of funnel chest with RTV-silicone implants (in German). Handchir Mikrochir Plast Chir 15:154–157PubMed Lemperle G, Exner K (1983) Treatment of funnel chest with RTV-silicone implants (in German). Handchir Mikrochir Plast Chir 15:154–157PubMed
15.
Zurück zum Zitat Leonhardt J, Kubler JF, Feiter J, Ure BM, Petersen C (2005) Complications of the minimally invasive repair of pectus excavatum. J Pediatr Surg 40:e7–e9PubMedCrossRef Leonhardt J, Kubler JF, Feiter J, Ure BM, Petersen C (2005) Complications of the minimally invasive repair of pectus excavatum. J Pediatr Surg 40:e7–e9PubMedCrossRef
16.
Zurück zum Zitat Luzzi L, Voltolini L, Zacharias J, Campione A, Ghiribelli C, Di Bisceglie M, Gotti G (2004) Ten-year experience of bioabsorbable mesh support in pectus excavatum repair. Br J Plast Surg 57:733–740PubMedCrossRef Luzzi L, Voltolini L, Zacharias J, Campione A, Ghiribelli C, Di Bisceglie M, Gotti G (2004) Ten-year experience of bioabsorbable mesh support in pectus excavatum repair. Br J Plast Surg 57:733–740PubMedCrossRef
17.
Zurück zum Zitat Marks MW, Argenta LC, Lee DC (1984) Silicone implant correction of pectus excavatum: Indications and refinement in technique. Plast Reconstr Surg 74:52–58PubMedCrossRef Marks MW, Argenta LC, Lee DC (1984) Silicone implant correction of pectus excavatum: Indications and refinement in technique. Plast Reconstr Surg 74:52–58PubMedCrossRef
18.
Zurück zum Zitat Miller KA, Woods RK, Sharp RJ, Gittes GK, Wade K, Ashcraft KW, Snyder CL, Andrews WM, Murphy JP, Holcomb GW III (2001) Minimally invasive repair of pectus excavatum: A single institution’s experience. Surgery 130:652–657, discussion 657–659PubMedCrossRef Miller KA, Woods RK, Sharp RJ, Gittes GK, Wade K, Ashcraft KW, Snyder CL, Andrews WM, Murphy JP, Holcomb GW III (2001) Minimally invasive repair of pectus excavatum: A single institution’s experience. Surgery 130:652–657, discussion 657–659PubMedCrossRef
19.
Zurück zum Zitat Moss RL, Albanese CT, Reynolds M (2001) Major complications after minimally invasive repair of pectus excavatum: Case reports. J Pediatr Surg 36:155–158PubMedCrossRef Moss RL, Albanese CT, Reynolds M (2001) Major complications after minimally invasive repair of pectus excavatum: Case reports. J Pediatr Surg 36:155–158PubMedCrossRef
20.
Zurück zum Zitat Murray JF (1965) Correction of pectus excavatum by synthetic subcutaneous implant. Presented at the American Society of Plastic and Reconstructive Surgery, Philadelphia, October Murray JF (1965) Correction of pectus excavatum by synthetic subcutaneous implant. Presented at the American Society of Plastic and Reconstructive Surgery, Philadelphia, October
21.
Zurück zum Zitat Nakuhara, et al. (1987) Operative outcomes in patients with funnel chest. J Thoracic Cardiovasc Surg 93:577 Nakuhara, et al. (1987) Operative outcomes in patients with funnel chest. J Thoracic Cardiovasc Surg 93:577
22.
Zurück zum Zitat Özgür F, Aksoy HM, Kayikçioglu A, Ariyürek M (1999) The effect of onlay MEDPOR implants on mandibular growth in young rabbits: An experimental study. Ann Plast Surg 42:No. 2 Özgür F, Aksoy HM, Kayikçioglu A, Ariyürek M (1999) The effect of onlay MEDPOR implants on mandibular growth in young rabbits: An experimental study. Ann Plast Surg 42:No. 2
23.
Zurück zum Zitat Paolini A, Ruggieri M, Leone Sossi FL, Paolini G, Dal Pra G, Scuderi N (1996) Pectus excavatum in adults: Destructive surgery or simple correction of an aesthetic defect? Riv Eur Sci Med Farmacol 18:11–17PubMed Paolini A, Ruggieri M, Leone Sossi FL, Paolini G, Dal Pra G, Scuderi N (1996) Pectus excavatum in adults: Destructive surgery or simple correction of an aesthetic defect? Riv Eur Sci Med Farmacol 18:11–17PubMed
24.
Zurück zum Zitat Park HJ, Lee SY, Lee CS (2004) Complications associated with the Nuss procedure: Analysis of risk factors and suggested measures for prevention of complications. J Pediatr Surg 39:391–395, discussion 391–395PubMedCrossRef Park HJ, Lee SY, Lee CS (2004) Complications associated with the Nuss procedure: Analysis of risk factors and suggested measures for prevention of complications. J Pediatr Surg 39:391–395, discussion 391–395PubMedCrossRef
25.
Zurück zum Zitat Rebeis EB, Samano MN, Santos Dias CT, Fernandez Â, Campos JRM, Jatene FB, Oliveira SA (2004) Anthropometric index for quantitative assessment of pectus excavatum. J Bras Pneumol 30:501–507CrossRef Rebeis EB, Samano MN, Santos Dias CT, Fernandez Â, Campos JRM, Jatene FB, Oliveira SA (2004) Anthropometric index for quantitative assessment of pectus excavatum. J Bras Pneumol 30:501–507CrossRef
26.
Zurück zum Zitat Rubin PAD, Popham JK, Bilyk JR, Shore JW (1994) Comparison of fibrovascular ingrowth into hydroxyapatite and porous polyethylene orbital implants. Ophthal Plast Reconstr Surg 10:96–103PubMedCrossRef Rubin PAD, Popham JK, Bilyk JR, Shore JW (1994) Comparison of fibrovascular ingrowth into hydroxyapatite and porous polyethylene orbital implants. Ophthal Plast Reconstr Surg 10:96–103PubMedCrossRef
27.
Zurück zum Zitat Shamberger RC, Welch KJ (1988) Surgical repair of pectus excavatum. J Pediatr Surg 23:615–622PubMedCrossRef Shamberger RC, Welch KJ (1988) Surgical repair of pectus excavatum. J Pediatr Surg 23:615–622PubMedCrossRef
28.
Zurück zum Zitat Sorensen JL (1988) Subcutaneous silicone implants in pectus excavatum. Scand J Plast Reconstr Surg Hand Surg 22:173–176PubMedCrossRef Sorensen JL (1988) Subcutaneous silicone implants in pectus excavatum. Scand J Plast Reconstr Surg Hand Surg 22:173–176PubMedCrossRef
29.
Zurück zum Zitat Watanabe A, Watanabe T, Obama T, Ohsawa H, Mawatari T, Ichimiya Y, Abe T (2004) The use of a lateral stabilizer increases the incidence of wound trouble following the Nuss procedure. Ann Thorac Surg 77:296–300PubMedCrossRef Watanabe A, Watanabe T, Obama T, Ohsawa H, Mawatari T, Ichimiya Y, Abe T (2004) The use of a lateral stabilizer increases the incidence of wound trouble following the Nuss procedure. Ann Thorac Surg 77:296–300PubMedCrossRef
30.
Zurück zum Zitat Wechselberger G, Ohlbauer M, Haslinger J, Schoeller T, Bauer T, Piza-Katzer H (2001) Silicone implant correction of pectus excavatum. Ann Plast Surg 47:489–493, Erratum in Ann Plast Surg 47:611, 2001PubMedCrossRef Wechselberger G, Ohlbauer M, Haslinger J, Schoeller T, Bauer T, Piza-Katzer H (2001) Silicone implant correction of pectus excavatum. Ann Plast Surg 47:489–493, Erratum in Ann Plast Surg 47:611, 2001PubMedCrossRef
31.
Zurück zum Zitat Wellisz T, Wallace RD (2000) Porous polyethylene and its biocompatibility. In: Terino EO, Flowers RS (eds) The art of alloplastic facial contouring. Mosby, St. Louis, pp. 261–272 Wellisz T, Wallace RD (2000) Porous polyethylene and its biocompatibility. In: Terino EO, Flowers RS (eds) The art of alloplastic facial contouring. Mosby, St. Louis, pp. 261–272
Metadaten
Titel
Aesthetic Treatment of Pectus Excavatum: A New Endoscopic Technique Using a Porous Polyethylene Implant
verfasst von
Simone Grappolini
Paolo M. Fanzio
Pierluca G. C. D’Addetta
Alberto Todde
Maurizio Infante
Publikationsdatum
01.01.2008
Verlag
Springer-Verlag
Erschienen in
Aesthetic Plastic Surgery / Ausgabe 1/2008
Print ISSN: 0364-216X
Elektronische ISSN: 1432-5241
DOI
https://doi.org/10.1007/s00266-007-9025-6

Weitere Artikel der Ausgabe 1/2008

Aesthetic Plastic Surgery 1/2008 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.