Skip to main content
Erschienen in: Rheumatology International 6/2015

01.06.2015 | Short Communication - Imaging

Green light may improve diagnostic accuracy of nailfold capillaroscopy with a simple digital videomicroscope

verfasst von: Harm H. A. Weekenstroo, Bart M. W. Cornelissen, Hein J. Bernelot Moens

Erschienen in: Rheumatology International | Ausgabe 6/2015

Einloggen, um Zugang zu erhalten

Abstract

Nailfold capillaroscopy is a non-invasive and safe technique for the analysis of microangiopathologies. Imaging quality of widely used simple videomicroscopes is poor. The use of green illumination instead of the commonly used white light may improve contrast. The aim of the study was to compare the effect of green illumination with white illumination, regarding capillary density, the number of microangiopathologies, and sensitivity and specificity for systemic sclerosis. Five rheumatologists have evaluated 80 images; 40 images acquired with green light, and 40 images acquired with white light. A larger number of microangiopathologies were found in images acquired with green light than in images acquired with white light. This results in slightly higher sensitivity with green light in comparison with white light, without reducing the specificity. These findings suggest that green instead of white illumination may facilitate evaluation of capillaroscopic images obtained with a low-cost digital videomicroscope.
Literatur
1.
Zurück zum Zitat Cutolo M, Sulli A, Smith V (2013) How to perform and interpret capillaroscopy. Best Pract Res Clin Rheumatol 27:237–248CrossRefPubMed Cutolo M, Sulli A, Smith V (2013) How to perform and interpret capillaroscopy. Best Pract Res Clin Rheumatol 27:237–248CrossRefPubMed
3.
Zurück zum Zitat Anderson ME, Allen PD, Moore T et al (2005) Computerized nailfold video capillaroscopy—a new tool for assessment of Raynaud’s phenomenon. J Rheumatol 32:841–848PubMed Anderson ME, Allen PD, Moore T et al (2005) Computerized nailfold video capillaroscopy—a new tool for assessment of Raynaud’s phenomenon. J Rheumatol 32:841–848PubMed
4.
Zurück zum Zitat Slaaf DW, Tangelder GJ, Reneman RS, Jäger K, Bollinger A (1987) A versatile incident illuminator for intravital microscopy. Int J Microcirc Clin Exp 6:391–397PubMed Slaaf DW, Tangelder GJ, Reneman RS, Jäger K, Bollinger A (1987) A versatile incident illuminator for intravital microscopy. Int J Microcirc Clin Exp 6:391–397PubMed
5.
Zurück zum Zitat Goedhart PT, Khalilzada M, Bezemer R, Merza J, Ince C (2007) Sidestream dark field (SDF) imaging: a novel stroboscopic LED ring-based imaging modality for clinical assessment of the microcirculation. Opt Express 15:15101–15114CrossRefPubMed Goedhart PT, Khalilzada M, Bezemer R, Merza J, Ince C (2007) Sidestream dark field (SDF) imaging: a novel stroboscopic LED ring-based imaging modality for clinical assessment of the microcirculation. Opt Express 15:15101–15114CrossRefPubMed
6.
Zurück zum Zitat Groner W, Winkelman JW, Harris AG, Ince C, Bouma GJ, Messmer K, Nadeau RG (1999) Orthogonal polarization spectral imaging: a new method for study of the microcirculation. Nat Med 5:1209–1212CrossRefPubMed Groner W, Winkelman JW, Harris AG, Ince C, Bouma GJ, Messmer K, Nadeau RG (1999) Orthogonal polarization spectral imaging: a new method for study of the microcirculation. Nat Med 5:1209–1212CrossRefPubMed
7.
Zurück zum Zitat Treu CM, Lupi O, Bottino DA, Bouskela E (2011) Sidestream dark field imaging: the evolution of real-time visualization of cutaneous microcirculation and its potential application in dermatology. Arch Dermatol Res 303:69–78CrossRefPubMed Treu CM, Lupi O, Bottino DA, Bouskela E (2011) Sidestream dark field imaging: the evolution of real-time visualization of cutaneous microcirculation and its potential application in dermatology. Arch Dermatol Res 303:69–78CrossRefPubMed
8.
Zurück zum Zitat Bauersachs RM, Lössner F (1997) The poor man’s capillary microscope. A novel technique for the assessment of capillary morphology. Ann Rheum Dis 56(7):435–437CrossRefPubMedCentralPubMed Bauersachs RM, Lössner F (1997) The poor man’s capillary microscope. A novel technique for the assessment of capillary morphology. Ann Rheum Dis 56(7):435–437CrossRefPubMedCentralPubMed
Metadaten
Titel
Green light may improve diagnostic accuracy of nailfold capillaroscopy with a simple digital videomicroscope
verfasst von
Harm H. A. Weekenstroo
Bart M. W. Cornelissen
Hein J. Bernelot Moens
Publikationsdatum
01.06.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Rheumatology International / Ausgabe 6/2015
Print ISSN: 0172-8172
Elektronische ISSN: 1437-160X
DOI
https://doi.org/10.1007/s00296-014-3193-x

Weitere Artikel der Ausgabe 6/2015

Rheumatology International 6/2015 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Alphablocker schützt vor Miktionsproblemen nach der Biopsie

16.05.2024 alpha-1-Rezeptorantagonisten Nachrichten

Nach einer Prostatabiopsie treten häufig Probleme beim Wasserlassen auf. Ob sich das durch den periinterventionellen Einsatz von Alphablockern verhindern lässt, haben australische Mediziner im Zuge einer Metaanalyse untersucht.

Eingreifen von Umstehenden rettet vor Erstickungstod!

15.05.2024 Fremdkörperaspiration Nachrichten

Wer sich an einem Essensrest verschluckt und um Luft ringt, benötigt vor allem rasche Hilfe. Dass Umstehende nur in jedem zweiten Erstickungsnotfall bereit waren, diese zu leisten, ist das ernüchternde Ergebnis einer Beobachtungsstudie aus Japan. Doch es gibt auch eine gute Nachricht.

Neue S3-Leitlinie zur unkomplizierten Zystitis: Auf Antibiotika verzichten?

15.05.2024 Harnwegsinfektionen Nachrichten

Welche Antibiotika darf man bei unkomplizierter Zystitis verwenden und wovon sollte man die Finger lassen? Welche pflanzlichen Präparate können helfen? Was taugt der zugelassene Impfstoff? Antworten vom Koordinator der frisch überarbeiteten S3-Leitlinie, Prof. Florian Wagenlehner.

Schadet Ärger den Gefäßen?

14.05.2024 Arteriosklerose Nachrichten

In einer Studie aus New York wirkte sich Ärger kurzfristig deutlich negativ auf die Endothelfunktion gesunder Probanden aus. Möglicherweise hat dies Einfluss auf die kardiovaskuläre Gesundheit.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.