Skip to main content
Erschienen in: European Radiology 4/2004

01.04.2004 | Pediatric

Dose and image quality in the comparison of analogue and digital techniques in paediatric urology examinations

verfasst von: Jan Persliden, Ebba Helmrot, Per Hjort, Margareta Resjö

Erschienen in: European Radiology | Ausgabe 4/2004

Einloggen, um Zugang zu erhalten

Abstract

In paediatric radiology it has been recognised that children have a higher risk of developing cancer from the irradiation than adults (two to three times); therefore, increased attention has been directed towards the dose to the patient. In this study the effect on patient dose and image quality in replacing the exposure in micturating cystourethrography (MCUG) examinations with the stored fluoroscopy image has been investigated. In the intravenous urography (IVU) examination we compared analogue and digital image quality, but the dose measurements were performed on a phantom. Standard clinical X-ray equipment was used. Sixty-eight patients in each of two centres were studied for the MCUG. Doses were measured with a dose-area product (DAP) meter and the image quality was scored. A non-parametric statistical analysis was performed. For the IVU, a phantom was used in the dose measurements but clinical images were scored in the comparison between analogue and digital images. For the MCUG, replacing the exposure with stored fluoroscopy images lowered the DAP value from 0.77 to 0.50 Gy cm2. The image quality did not show any difference between the techniques; however, if reflux was to be graded, exposure was needed. For the IVU, the doses could be lowered by a factor of 3 using digital techniques. The image quality showed no statistical difference between the two techniques. There is a potential for a substantial dose reduction in both MUCG and IVU examinations using digital techniques.
Literatur
1.
Zurück zum Zitat Fendel H, Schneider K, Kohn MM, Bakowski C (1989) Specific principles for optimization in image quality and patient exposure in paediatric diagnostic imaging. BIR Rep 20:91–101 Fendel H, Schneider K, Kohn MM, Bakowski C (1989) Specific principles for optimization in image quality and patient exposure in paediatric diagnostic imaging. BIR Rep 20:91–101
2.
Zurück zum Zitat European Guidelines on Quality Criteria for Diagnostic Radiograpic Images in Paediatrics (1996) EUR 16261 EN, Luxembourg, ISBN 92-827-7843-6 European Guidelines on Quality Criteria for Diagnostic Radiograpic Images in Paediatrics (1996) EUR 16261 EN, Luxembourg, ISBN 92-827-7843-6
3.
Zurück zum Zitat ICRP 60 (1991) Recommendations of the International Commission of Radiological Protection. Pergamon Press, Oxford ICRP 60 (1991) Recommendations of the International Commission of Radiological Protection. Pergamon Press, Oxford
4.
Zurück zum Zitat Hallén S, Martling K, Mattsson S (1992) Dosimetry at X-ray examinations of scoliosis. Radiat Prot Dosim 43:49–54 Hallén S, Martling K, Mattsson S (1992) Dosimetry at X-ray examinations of scoliosis. Radiat Prot Dosim 43:49–54
5.
Zurück zum Zitat Gallini RE, Belletti S, Berna V, Guigni U (1992) Adult and child doses in standardised X-ray examinations. Radiat Prot Dosim 43:41–49 Gallini RE, Belletti S, Berna V, Guigni U (1992) Adult and child doses in standardised X-ray examinations. Radiat Prot Dosim 43:41–49
6.
Zurück zum Zitat Schneider K, Fendel H, Bakowski C, Stein E, Kohn M, Kellner M, Schweighofer K, Cartagena G, Padovani R, Panzer W, Scheurer C, Wall B (1992) Results of a dosimetric study in the European community on frequent X-ray examinations in infants. Radiat Prot Dosim 43:31–36 Schneider K, Fendel H, Bakowski C, Stein E, Kohn M, Kellner M, Schweighofer K, Cartagena G, Padovani R, Panzer W, Scheurer C, Wall B (1992) Results of a dosimetric study in the European community on frequent X-ray examinations in infants. Radiat Prot Dosim 43:31–36
7.
Zurück zum Zitat Almén A (1995) Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies. Doctoral Dissertation, Department of Radiation Physics, Malmö University Hospital, Malmö, Sweden Almén A (1995) Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies. Doctoral Dissertation, Department of Radiation Physics, Malmö University Hospital, Malmö, Sweden
8.
Zurück zum Zitat Reuter FG, Conway BJ, McCrohan JL, Slayton RJ, Suleiman OH (1992) Assessment of skin entrance kerma in the United States: the nationwide evaluation of X ray trends (NEXT). Radiat Prot Dosim 43:71–73 Reuter FG, Conway BJ, McCrohan JL, Slayton RJ, Suleiman OH (1992) Assessment of skin entrance kerma in the United States: the nationwide evaluation of X ray trends (NEXT). Radiat Prot Dosim 43:71–73
9.
Zurück zum Zitat Supe SJ, Iyer PS, Sasane JB, Sawant SG, Shirva VK (1992) Estimation and significance of patient doses from diagnostic X ray practises in India. Radiat Prot Dosim 43:209–211 Supe SJ, Iyer PS, Sasane JB, Sawant SG, Shirva VK (1992) Estimation and significance of patient doses from diagnostic X ray practises in India. Radiat Prot Dosim 43:209–211
10.
Zurück zum Zitat Maruyama T, Kumamoto Y, Noda Y, Iwai K, Mase N, Nishizawa K, Furuya Y (1992) Determinations of organ or tissue doses and collective effective dose equivalent from diagnostic X-ray examinations in Japan. Radiat Prot Dosim 43:213–216 Maruyama T, Kumamoto Y, Noda Y, Iwai K, Mase N, Nishizawa K, Furuya Y (1992) Determinations of organ or tissue doses and collective effective dose equivalent from diagnostic X-ray examinations in Japan. Radiat Prot Dosim 43:213–216
11.
Zurück zum Zitat Nicholson RA, Thornton A, Akpan M (1995) Radiation dose reduction in paediatric fluoroscopy using added filtration. Br J Radiol 68:296–300PubMed Nicholson RA, Thornton A, Akpan M (1995) Radiation dose reduction in paediatric fluoroscopy using added filtration. Br J Radiol 68:296–300PubMed
12.
Zurück zum Zitat Gonzalez L, Vano E, Ruiz MJ (1995) Radiation doses to paediatric patients undergoing micturating cystourethrography examinations and potential reduction by radiation protection optimization. Br J Radiol 68:291–295PubMed Gonzalez L, Vano E, Ruiz MJ (1995) Radiation doses to paediatric patients undergoing micturating cystourethrography examinations and potential reduction by radiation protection optimization. Br J Radiol 68:291–295PubMed
13.
Zurück zum Zitat Hansson B, Finnbogason T, Schuwert P, Persliden J (1997) Added copper filtration in pediatric double-contrast colon examinations: effects on radiation dose and image. Eur Radiol 7:1117–1122CrossRefPubMed Hansson B, Finnbogason T, Schuwert P, Persliden J (1997) Added copper filtration in pediatric double-contrast colon examinations: effects on radiation dose and image. Eur Radiol 7:1117–1122CrossRefPubMed
14.
Zurück zum Zitat Persliden J, Petterson HBL, Fälth-Magnusson K (1996) Radiation dose at small intestinal biopsies in children: results of a national study. Acta Paediatr 85:1042–1046PubMed Persliden J, Petterson HBL, Fälth-Magnusson K (1996) Radiation dose at small intestinal biopsies in children: results of a national study. Acta Paediatr 85:1042–1046PubMed
15.
Zurück zum Zitat Geijer H, Verdonck B, Beckman KW, Andersson T, Persliden J (2003) Digital radiography of scoliosis with a scanning method: radiation dose optimisation. Eur Radiol 13:543–551PubMed Geijer H, Verdonck B, Beckman KW, Andersson T, Persliden J (2003) Digital radiography of scoliosis with a scanning method: radiation dose optimisation. Eur Radiol 13:543–551PubMed
16.
Zurück zum Zitat Persliden J, Beckman KW, Geijer H, Andersson T (2002) Dose-image optimisation in digital radiology with a direct digital detector: an example applied to pelvic examinations. Eur Radiol 12:1584–1588CrossRefPubMed Persliden J, Beckman KW, Geijer H, Andersson T (2002) Dose-image optimisation in digital radiology with a direct digital detector: an example applied to pelvic examinations. Eur Radiol 12:1584–1588CrossRefPubMed
17.
Zurück zum Zitat Almen A, Mattsson S (1995) The radiation dose to children from X-ray examinations of the pelvis and the urinary tract. Br J Radiol 68:604–613PubMed Almen A, Mattsson S (1995) The radiation dose to children from X-ray examinations of the pelvis and the urinary tract. Br J Radiol 68:604–613PubMed
18.
Zurück zum Zitat Smith T, Gordon I, Kelly JP (1998) Comparison of radiation dose from intravenous urography and99Tcm-DMSA scintigraphy in children. Br J Radiol 71:314–319PubMed Smith T, Gordon I, Kelly JP (1998) Comparison of radiation dose from intravenous urography and99Tcm-DMSA scintigraphy in children. Br J Radiol 71:314–319PubMed
19.
Zurück zum Zitat Vestergren E (1998) Administered radiopharmaceutical activity and radiation dosimetry in paediatric nuclear medicine. Thesis, Department of Radiation Physics, Gothenburg University, Gothenburg, Sweden, ISBN 91-628-2951-3 Vestergren E (1998) Administered radiopharmaceutical activity and radiation dosimetry in paediatric nuclear medicine. Thesis, Department of Radiation Physics, Gothenburg University, Gothenburg, Sweden, ISBN 91-628-2951-3
Metadaten
Titel
Dose and image quality in the comparison of analogue and digital techniques in paediatric urology examinations
verfasst von
Jan Persliden
Ebba Helmrot
Per Hjort
Margareta Resjö
Publikationsdatum
01.04.2004
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 4/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2144-9

Weitere Artikel der Ausgabe 4/2004

European Radiology 4/2004 Zur Ausgabe

Calendar of Events

April 2004

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.