Skip to main content
Erschienen in: European Radiology 9/2017

26.01.2017 | Neuro

Intermediate analysis of magnesium alloy covered stent for a lateral aneurysm model in the rabbit common carotid artery

verfasst von: Hong-kai Cui, Fen-Bao Li, Ying-Chang Guo, Yong-Li Zhao, Rui-Fang Yan, Wu Wang, Yong-Dong Li, Yong-Li Wang, Guang-Yin Yuan

Erschienen in: European Radiology | Ausgabe 9/2017

Einloggen, um Zugang zu erhalten

Abstract

Objective

To analyze the outcomes of a magnesium alloy covered stent (MACS) for a lateral aneurysm model in common carotid artery (CCA).

Methods

In 32 rabbits, a MACS (group A, n = 17) or a Willis covered stent (WCS; group B, n = 15) was inserted and the rabbits were sacrificed 1, 3, 6, or 12 months after stenting. Angiography and intravascular ultrasound (IVUS) were performed at 3, 6, and 12 months. Scanning electron microscopy was performed for six stents in each group at 1, 3, and 6 months, and histopathology and histomorphology were conducted at 3 (n = 4), 6 (n = 4), and 12 (n = 12) months.

Results

Final angiography showed complete occlusion of the aneurysms in 12 cases. IVUS at 6 and 12 months revealed a significant increase in mean lumen area of the stented CCA in group A and also showed greater mean lumen area in group A than in group B. The endothelialization process was quicker in group A than in group B.

Conclusion

MACS is effective for occlusion of lateral aneurysms and is superior to WCS in growth of the stented CCA and endothelialization. Further work is needed to make this device available for human use.

Key points

The MACS is an effective approach for occlusion of a lateral aneurysm.
IVUS showed that the CCA could grow following degradation of the MACS.
The lumen area of the stented CCA was excellent in MACS.
HE staining displayed the degradation of the magnesium alloy stent.
Combination of IVUS and DSA were applied in this study.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Li MH, Chen SW, Li YD, Chen YC, Cheng YS, Hu DJ et al (2013) Prevalence of Unruptured Cerebral Aneurysms in Chinese Adults Aged 35 to 75 Years: A Cross-sectional Study. Ann Intern Med 159:514–521CrossRefPubMed Li MH, Chen SW, Li YD, Chen YC, Cheng YS, Hu DJ et al (2013) Prevalence of Unruptured Cerebral Aneurysms in Chinese Adults Aged 35 to 75 Years: A Cross-sectional Study. Ann Intern Med 159:514–521CrossRefPubMed
2.
Zurück zum Zitat Nakagawa T, Hashi K (1994) The incidence and treatment of asymptomatic, unruptured cerebral aneurysms. J Neurosurg 80:217–223CrossRefPubMed Nakagawa T, Hashi K (1994) The incidence and treatment of asymptomatic, unruptured cerebral aneurysms. J Neurosurg 80:217–223CrossRefPubMed
3.
4.
Zurück zum Zitat Vlak MH, Algra A, Brandenburg R, Rinkel GJ (2011) Prevalence of unruptured intracranial aneurysms, with emphasis on sex, age, comorbidity, country, and time period: a systematic review and meta-analysis. Lancet Neurol 10:626–636CrossRefPubMed Vlak MH, Algra A, Brandenburg R, Rinkel GJ (2011) Prevalence of unruptured intracranial aneurysms, with emphasis on sex, age, comorbidity, country, and time period: a systematic review and meta-analysis. Lancet Neurol 10:626–636CrossRefPubMed
5.
Zurück zum Zitat Frösen J, Tulamo R, Paetau A, Laaksamo E, Korja M, Laakso A et al (2012) Saccular intracranial aneurysm: pathology and mechanisms. Acta Neuropathol 123:773–786CrossRefPubMed Frösen J, Tulamo R, Paetau A, Laaksamo E, Korja M, Laakso A et al (2012) Saccular intracranial aneurysm: pathology and mechanisms. Acta Neuropathol 123:773–786CrossRefPubMed
6.
7.
Zurück zum Zitat Bederson JB, Connolly ES Jr, Batjer HH, Dacey RG, Dion JE, Diringer MN et al (2009) American Heart Association. Guidelines for the management of aneurysmal subarachnoid hemorrhage: a statement for healthcare professionals from a special writing group of the Stroke Council, American Heart Association. Stroke 40:994–1025CrossRefPubMed Bederson JB, Connolly ES Jr, Batjer HH, Dacey RG, Dion JE, Diringer MN et al (2009) American Heart Association. Guidelines for the management of aneurysmal subarachnoid hemorrhage: a statement for healthcare professionals from a special writing group of the Stroke Council, American Heart Association. Stroke 40:994–1025CrossRefPubMed
8.
Zurück zum Zitat Wardlaw JM, White PM (2000) The detection and management of unruptured intracranial aneurysms. Brain 123:205–221CrossRefPubMed Wardlaw JM, White PM (2000) The detection and management of unruptured intracranial aneurysms. Brain 123:205–221CrossRefPubMed
9.
Zurück zum Zitat Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J et al (2002) International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1267–1274CrossRefPubMed Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J et al (2002) International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1267–1274CrossRefPubMed
10.
Zurück zum Zitat Mordasini P, Schroth G, Guzman R, Barth A, Seiler RW, Remonda L (2005) Endovascular treatment of posterior circulation cerebral aneurysms by using Guglielmi detachable coils: a 10-year single-center experience with special regard to technical development. AJNR Am J Neuroradiol 26:1732–1738PubMed Mordasini P, Schroth G, Guzman R, Barth A, Seiler RW, Remonda L (2005) Endovascular treatment of posterior circulation cerebral aneurysms by using Guglielmi detachable coils: a 10-year single-center experience with special regard to technical development. AJNR Am J Neuroradiol 26:1732–1738PubMed
11.
Zurück zum Zitat Szikora I, Seifert P, Hanzely Z, Kulcsar Z, Berentei Z, Marosfoi M et al (2006) Histopathologic evaluation of aneurysms treated with Guglielmi detachable coils or matrix detachable microcoils. AJNR Am J Neuroradiol 27:283–288PubMed Szikora I, Seifert P, Hanzely Z, Kulcsar Z, Berentei Z, Marosfoi M et al (2006) Histopathologic evaluation of aneurysms treated with Guglielmi detachable coils or matrix detachable microcoils. AJNR Am J Neuroradiol 27:283–288PubMed
12.
Zurück zum Zitat Bavinzski G, Talazoglu V, Killer M, Richling B, Gruber A, Gross CE et al (1999) Gross and microscopic histopathological findings in aneurysms of the human brain treated with Guglielmi detachable coils. J Neurosurg 91:284–293CrossRefPubMed Bavinzski G, Talazoglu V, Killer M, Richling B, Gruber A, Gross CE et al (1999) Gross and microscopic histopathological findings in aneurysms of the human brain treated with Guglielmi detachable coils. J Neurosurg 91:284–293CrossRefPubMed
13.
Zurück zum Zitat D’Urso PI, Lanzino G, Cloft HJ, Kallmes DF (2011) Flow diversion for intracranial aneurysms: A review. Stroke 42:2363–2368CrossRefPubMed D’Urso PI, Lanzino G, Cloft HJ, Kallmes DF (2011) Flow diversion for intracranial aneurysms: A review. Stroke 42:2363–2368CrossRefPubMed
14.
Zurück zum Zitat Lylyk P, Miranda C, Ceratto R, Ferrario A, Scrivano E, Luna HR et al (2009) Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: The Buenos Aires experience. Neurosurgery 64:632–642CrossRefPubMed Lylyk P, Miranda C, Ceratto R, Ferrario A, Scrivano E, Luna HR et al (2009) Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: The Buenos Aires experience. Neurosurgery 64:632–642CrossRefPubMed
15.
Zurück zum Zitat Li YD, Li MH, Gao BL, Fang C, Cheng YS, Wang W et al (2010) Endovascular treatment of recurrent intracranial aneurysms with re-coiling or covered stents. J Neurol Neurosurg Psychiatry 81:74–79CrossRefPubMed Li YD, Li MH, Gao BL, Fang C, Cheng YS, Wang W et al (2010) Endovascular treatment of recurrent intracranial aneurysms with re-coiling or covered stents. J Neurol Neurosurg Psychiatry 81:74–79CrossRefPubMed
16.
Zurück zum Zitat Li MH, Li YD, Tan HQ, Luo QY, Cheng YS (2009) Treatment of Distal Internal Carotid Artery Aneurysm with the Willis Covered Stent: A Prospective Pilot Study. Radiology 253:470–477CrossRefPubMed Li MH, Li YD, Tan HQ, Luo QY, Cheng YS (2009) Treatment of Distal Internal Carotid Artery Aneurysm with the Willis Covered Stent: A Prospective Pilot Study. Radiology 253:470–477CrossRefPubMed
17.
Zurück zum Zitat John S, Bain MD, Hui FK, Hussain MS, Masaryk TJ, Rasmussen PA et al (2016) Long-term Follow-up of In-stent Stenosis After Pipeline Flow Diversion Treatment of Intracranial Aneurysms. Neurosurgery 78:862–867CrossRefPubMed John S, Bain MD, Hui FK, Hussain MS, Masaryk TJ, Rasmussen PA et al (2016) Long-term Follow-up of In-stent Stenosis After Pipeline Flow Diversion Treatment of Intracranial Aneurysms. Neurosurgery 78:862–867CrossRefPubMed
18.
Zurück zum Zitat Vargas SA, Diaz C, Herrera DA, Dublin AB (2016) Intracranial Aneurysms in Children: The Role of Stenting and Flow-Diversion. J Neuroimaging 26:41–45CrossRefPubMed Vargas SA, Diaz C, Herrera DA, Dublin AB (2016) Intracranial Aneurysms in Children: The Role of Stenting and Flow-Diversion. J Neuroimaging 26:41–45CrossRefPubMed
19.
Zurück zum Zitat Kirkland NT (2012) Magnesium biomaterials: past, present and future. Corros Eng Sci Technol 47:322–328CrossRef Kirkland NT (2012) Magnesium biomaterials: past, present and future. Corros Eng Sci Technol 47:322–328CrossRef
20.
Zurück zum Zitat Erbel R, Di Mario C, Bartunek J, Bonnier J, de Bruyne B, Eberli FR et al (2007) PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial. Lancet 369:1869–1875CrossRefPubMed Erbel R, Di Mario C, Bartunek J, Bonnier J, de Bruyne B, Eberli FR et al (2007) PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial. Lancet 369:1869–1875CrossRefPubMed
21.
Zurück zum Zitat Waksman R, Erbel R, Di Mario C, Bartunek J, de Bruyne B, Eberli FR et al (2009) PROGRESS-AMS (Clinical Performance Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators. Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries. JACC Cardiovasc Interv 2:312–320CrossRefPubMed Waksman R, Erbel R, Di Mario C, Bartunek J, de Bruyne B, Eberli FR et al (2009) PROGRESS-AMS (Clinical Performance Angiographic Results of Coronary Stenting with Absorbable Metal Stents) Investigators. Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries. JACC Cardiovasc Interv 2:312–320CrossRefPubMed
22.
Zurück zum Zitat Yue Y, Wang L, Yang N, Huang J, Lei L, Ye H et al (2015) Effectiveness of Biodegradable Magnesium Alloy Stents in Coronary Artery and Femoral Artery. J Interv Cardiol 28:358–364CrossRefPubMed Yue Y, Wang L, Yang N, Huang J, Lei L, Ye H et al (2015) Effectiveness of Biodegradable Magnesium Alloy Stents in Coronary Artery and Femoral Artery. J Interv Cardiol 28:358–364CrossRefPubMed
23.
Zurück zum Zitat Mao L, Yuan GY, Niu JL, Zong Y, Ding WJ (2013) In vitro degradation behavior and biocompatibility of Mg- Nd-Zn- Zr alloy by hydro fluoric acid treatment. Mater Sci Eng C 33:242–250CrossRef Mao L, Yuan GY, Niu JL, Zong Y, Ding WJ (2013) In vitro degradation behavior and biocompatibility of Mg- Nd-Zn- Zr alloy by hydro fluoric acid treatment. Mater Sci Eng C 33:242–250CrossRef
24.
Zurück zum Zitat Liu F, Chen C, Niu J, Pei J, Zhang H, Huang H et al (2015) The processing of Mg alloy micro-tubes for biodegradable vascular stents. Mater Sci Eng C, Mater Biol Appl 48:400–407CrossRef Liu F, Chen C, Niu J, Pei J, Zhang H, Huang H et al (2015) The processing of Mg alloy micro-tubes for biodegradable vascular stents. Mater Sci Eng C, Mater Biol Appl 48:400–407CrossRef
25.
Zurück zum Zitat Schwartz RS, Huber KC, Murphy JG, Edwards WD, Camrud AR, Vlietstra RE et al (1992) Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. J Am Coll Cardiol 19:267–274CrossRefPubMed Schwartz RS, Huber KC, Murphy JG, Edwards WD, Camrud AR, Vlietstra RE et al (1992) Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. J Am Coll Cardiol 19:267–274CrossRefPubMed
26.
Zurück zum Zitat Chu Z, Zheng Q, Guo M, Yao J, Xu P, Feng W et al (2016) The effect of fluid shear stress on the in vitro degradation of poly(lactide-co-glycolide) acid membranes. J Biomed Mater Res A 104:2315–2324CrossRefPubMed Chu Z, Zheng Q, Guo M, Yao J, Xu P, Feng W et al (2016) The effect of fluid shear stress on the in vitro degradation of poly(lactide-co-glycolide) acid membranes. J Biomed Mater Res A 104:2315–2324CrossRefPubMed
27.
Zurück zum Zitat Reneman RS, Arts T, Hoeks AP (2006) Wall shear stress--an important determinant of endothelial cell function and structure--in the arterial system in vivo. Discrepancies with theory. J Vasc Res 43:251–269CrossRefPubMed Reneman RS, Arts T, Hoeks AP (2006) Wall shear stress--an important determinant of endothelial cell function and structure--in the arterial system in vivo. Discrepancies with theory. J Vasc Res 43:251–269CrossRefPubMed
28.
Zurück zum Zitat Chen HY, Koo BK, Kassab GS (2015) Impact of bifurcation dual stenting on endothelial shear stress. J Appl Physiol (1985) 119:627–632CrossRef Chen HY, Koo BK, Kassab GS (2015) Impact of bifurcation dual stenting on endothelial shear stress. J Appl Physiol (1985) 119:627–632CrossRef
29.
Zurück zum Zitat Haude M, Erbel R, Erne P, Verheye S, Degen H, Böse D et al (2013) Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial. Lancet 381:836–844CrossRefPubMed Haude M, Erbel R, Erne P, Verheye S, Degen H, Böse D et al (2013) Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial. Lancet 381:836–844CrossRefPubMed
30.
Zurück zum Zitat Maeng M, Jensen LO, Falk E, Andersen HR, Thuesen L (2009) Negative vascular remodelling after implantation of bioabsorbable magnesium alloy stents in porcine coronary arteries: a randomised comparison with bare-metal and sirolimus-eluting stents. Heart 95:241–246CrossRefPubMed Maeng M, Jensen LO, Falk E, Andersen HR, Thuesen L (2009) Negative vascular remodelling after implantation of bioabsorbable magnesium alloy stents in porcine coronary arteries: a randomised comparison with bare-metal and sirolimus-eluting stents. Heart 95:241–246CrossRefPubMed
31.
Zurück zum Zitat Ghimire G, Spiro J, Kharbanda R, Roughton M, Barlis P, Mason M et al (2009) Initial evidence for the return of coronary vasoreactivity following the absorption of bioabsorbable magnesium alloy coronary stents. EuroIntervention 4:481–484CrossRefPubMed Ghimire G, Spiro J, Kharbanda R, Roughton M, Barlis P, Mason M et al (2009) Initial evidence for the return of coronary vasoreactivity following the absorption of bioabsorbable magnesium alloy coronary stents. EuroIntervention 4:481–484CrossRefPubMed
32.
Zurück zum Zitat Li H, Zhong H, Xu K, Yang K, Liu J, Zhang B et al (2011) Enhanced efficacy of sirolimus-eluting bioabsorbable magnesium alloy stents in the prevention of restenosis. J Endovasc Ther 18:407–415CrossRefPubMed Li H, Zhong H, Xu K, Yang K, Liu J, Zhang B et al (2011) Enhanced efficacy of sirolimus-eluting bioabsorbable magnesium alloy stents in the prevention of restenosis. J Endovasc Ther 18:407–415CrossRefPubMed
Metadaten
Titel
Intermediate analysis of magnesium alloy covered stent for a lateral aneurysm model in the rabbit common carotid artery
verfasst von
Hong-kai Cui
Fen-Bao Li
Ying-Chang Guo
Yong-Li Zhao
Rui-Fang Yan
Wu Wang
Yong-Dong Li
Yong-Li Wang
Guang-Yin Yuan
Publikationsdatum
26.01.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 9/2017
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-016-4715-6

Weitere Artikel der Ausgabe 9/2017

European Radiology 9/2017 Zur Ausgabe

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.