Objectives

Preoperative estimation of the insertion depth angle of cochlear implant (CI) electrodes is essential for surgical planning. The purpose of this study was to determine the cochlear size using preoperative CT and to investigate the correlation between cochlear size and insertion depth angle in morphologically normal cochlea.

Methods

Thirty-five children who underwent CI were included in this study. Cochlear duct length (CDL) and the diameter of the cochlear basal turn (distance A/B) on preoperative CT and the insertion depth angle of the CI electrode on postoperative radiographs were independently measured by two readers. Correlation between cochlear size and insertion depth angle was evaluated. Interobserver agreement was calculated using the intraclass correlation coefficient (ICC).

Results

The mean CDL, distance A, and distance B of 70 ears were 36.20 ± 1.57 mm, 8.67 ± 0.42 mm, and 5.73 ± 0.32 mm, respectively. The mean insertion depth angle was 431.45 ± 38.42°. Interobserver agreements of CDL, distance A/B, and insertion depth angle were fair to excellent (ICC 0.864, 0.862, 0.529, and 0.958, respectively). Distance A (r = − 0.7643) and distance B (r = − 0.7118) showed a negative correlation with insertion depth angle, respectively (p < 0.0001). However, the correlation between CDL and insertion depth angle was not statistically significant (r = − 0.2333, p > 0.05).

Conclusions

The CDL and cochlear distance can be reliably obtained from preoperative CT. Distance A can be used as a predictive marker for estimating insertion depth angle during CI surgery.
Literatur
1.
Zurück zum Zitat Wanna GB, Noble JH, Gifford RH et al (2015) Impact of intrascalar electrode location, electrode type, and angular insertion depth on residual hearing in cochlear implant patients: preliminary results. Otol Neurotol 36:1343–1348CrossRef Wanna GB, Noble JH, Gifford RH et al (2015) Impact of intrascalar electrode location, electrode type, and angular insertion depth on residual hearing in cochlear implant patients: preliminary results. Otol Neurotol 36:1343–1348CrossRef
2.
Zurück zum Zitat Hochmair I, Arnold W, Nopp P, Jolly C, Müller J, Roland P (2003) Deep electrode insertion in cochlear implants: apical morphology, electrodes and speech perception results. Acta Otolaryngol 123:612–617PubMed Hochmair I, Arnold W, Nopp P, Jolly C, Müller J, Roland P (2003) Deep electrode insertion in cochlear implants: apical morphology, electrodes and speech perception results. Acta Otolaryngol 123:612–617PubMed
3.
Zurück zum Zitat Hochmair I, Hochmair E, Nopp P, Waller M, Jolly C (2015) Deep electrode insertion and sound coding in cochlear implants. Hear Res 322:14–23CrossRef Hochmair I, Hochmair E, Nopp P, Waller M, Jolly C (2015) Deep electrode insertion and sound coding in cochlear implants. Hear Res 322:14–23CrossRef
4.
Zurück zum Zitat Roy AT, Penninger RT, Pearl MS et al (2016) Deeper cochlear implant electrode insertion angle improves detection of musical sound quality deterioration related to bass frequency removal. Otol Neurotol 37:146–151CrossRef Roy AT, Penninger RT, Pearl MS et al (2016) Deeper cochlear implant electrode insertion angle improves detection of musical sound quality deterioration related to bass frequency removal. Otol Neurotol 37:146–151CrossRef
5.
Zurück zum Zitat O’Connell BP, Cakir A, Hunter JB et al (2016) Electrode location and angular insertion depth are predictors of audiologic outcomes in cochlear implantation. Otol Neurotol 37:1016CrossRef O’Connell BP, Cakir A, Hunter JB et al (2016) Electrode location and angular insertion depth are predictors of audiologic outcomes in cochlear implantation. Otol Neurotol 37:1016CrossRef
6.
Zurück zum Zitat Adunka O, Kiefer J (2006) Impact of electrode insertion depth on intracochlear trauma. Otolaryngol Head Neck Surg 135:374–382CrossRef Adunka O, Kiefer J (2006) Impact of electrode insertion depth on intracochlear trauma. Otolaryngol Head Neck Surg 135:374–382CrossRef
7.
Zurück zum Zitat Welling DB, Hinojosa R, Gantz BJ, Lee JT (1993) Insertional trauma of multichannel cochlear implants. Laryngoscope 103:995–1001CrossRef Welling DB, Hinojosa R, Gantz BJ, Lee JT (1993) Insertional trauma of multichannel cochlear implants. Laryngoscope 103:995–1001CrossRef
8.
Zurück zum Zitat Gstoettner W, Pok S, Peters S, Kiefer J, Adunka O (2005) Cochlear implantation with preservation of residual deep frequency hearing. HNO 53:784–790CrossRef Gstoettner W, Pok S, Peters S, Kiefer J, Adunka O (2005) Cochlear implantation with preservation of residual deep frequency hearing. HNO 53:784–790CrossRef
9.
Zurück zum Zitat Erixon E, Rask-Andersen H (2013) How to predict cochlear length before cochlear implantation surgery. Acta Otolaryngol 133:1258–1265CrossRef Erixon E, Rask-Andersen H (2013) How to predict cochlear length before cochlear implantation surgery. Acta Otolaryngol 133:1258–1265CrossRef
10.
Zurück zum Zitat Dimopoulos P, Muren C (1990) Anatomic variations of the cochlea and relations to other temporal bone structures. Acta Radiol 31:439–444CrossRef Dimopoulos P, Muren C (1990) Anatomic variations of the cochlea and relations to other temporal bone structures. Acta Radiol 31:439–444CrossRef
11.
Zurück zum Zitat Avci E, Nauwelaers T, Lenarz T, Hamacher V, Kral A (2014) Variations in microanatomy of the human cochlea. J Comp Neurol 522:3245–3261CrossRef Avci E, Nauwelaers T, Lenarz T, Hamacher V, Kral A (2014) Variations in microanatomy of the human cochlea. J Comp Neurol 522:3245–3261CrossRef
12.
Zurück zum Zitat Hardy M (1938) The length of the organ of Corti in man. Am J Anat 62:291–311CrossRef Hardy M (1938) The length of the organ of Corti in man. Am J Anat 62:291–311CrossRef
13.
Zurück zum Zitat Kawano A, Seldon HL, Clark GM (1996) Computer-aided three-dimensional reconstruction in human cochlear maps: measurement of the lengths of organ of Corti, outer wall, inner wall, and Rosenthal’s canal. Ann Otol Rhinol Laryngol 105:701–709CrossRef Kawano A, Seldon HL, Clark GM (1996) Computer-aided three-dimensional reconstruction in human cochlear maps: measurement of the lengths of organ of Corti, outer wall, inner wall, and Rosenthal’s canal. Ann Otol Rhinol Laryngol 105:701–709CrossRef
14.
Zurück zum Zitat Ketten DR, Skinner MW, Wang G, Vannier MW, Gates GA, Gail Neely J (1998) In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays. Ann Otol Rhinol Laryngol Suppl 175:1–16 Ketten DR, Skinner MW, Wang G, Vannier MW, Gates GA, Gail Neely J (1998) In vivo measures of cochlear length and insertion depth of nucleus cochlear implant electrode arrays. Ann Otol Rhinol Laryngol Suppl 175:1–16
15.
Zurück zum Zitat Meng J, Li S, Zhang F, Li Q, Qin Z (2016) Cochlear size and shape variability and implications in cochlear implantation surgery. Otol Neurotol 37:1307–1313CrossRef Meng J, Li S, Zhang F, Li Q, Qin Z (2016) Cochlear size and shape variability and implications in cochlear implantation surgery. Otol Neurotol 37:1307–1313CrossRef
16.
Zurück zum Zitat Würfel W, Lanfermann H, Lenarz T, Majdani O (2014) Cochlear length determination using cone beam computed tomography in a clinical setting. Hear Res 316:65–72CrossRef Würfel W, Lanfermann H, Lenarz T, Majdani O (2014) Cochlear length determination using cone beam computed tomography in a clinical setting. Hear Res 316:65–72CrossRef
17.
Zurück zum Zitat Escudé B, James C, Deguine O, Cochard N, Eter E, Fraysse B (2006) The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiol Neurootol 11:27–33CrossRef Escudé B, James C, Deguine O, Cochard N, Eter E, Fraysse B (2006) The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiol Neurootol 11:27–33CrossRef
18.
Zurück zum Zitat Koch RW, Ladak HM, Elfarnawany M, Agrawal SK (2017) Measuring cochlear duct length–a historical analysis of methods and results. J Otolaryngol Head Neck Surg 46:19CrossRef Koch RW, Ladak HM, Elfarnawany M, Agrawal SK (2017) Measuring cochlear duct length–a historical analysis of methods and results. J Otolaryngol Head Neck Surg 46:19CrossRef
19.
Zurück zum Zitat Catmull E, Rom R (1974) A class of local interpolating splines. In: Computer aided geometric design. Academic Press, New York, pp 317–326 Catmull E, Rom R (1974) A class of local interpolating splines. In: Computer aided geometric design. Academic Press, New York, pp 317–326
20.
Zurück zum Zitat Yuksel C, Schaefer S, Keyser J (2011) Parameterization and applications of Catmull–Rom curves. Comput Aided Des 43:747–755CrossRef Yuksel C, Schaefer S, Keyser J (2011) Parameterization and applications of Catmull–Rom curves. Comput Aided Des 43:747–755CrossRef
21.
Zurück zum Zitat Alexiades G, Dhanasingh A, Jolly C (2015) Method to estimate the complete and two-turn cochlear duct length. Otol Neurotol 36:904–907CrossRef Alexiades G, Dhanasingh A, Jolly C (2015) Method to estimate the complete and two-turn cochlear duct length. Otol Neurotol 36:904–907CrossRef
22.
Zurück zum Zitat Xu J, Xu S-A, Cohen LT, Clark GM (2000) Cochlear view: postoperative radiography for cochlear implantation. Otol Neurotol 21:49–56 Xu J, Xu S-A, Cohen LT, Clark GM (2000) Cochlear view: postoperative radiography for cochlear implantation. Otol Neurotol 21:49–56
23.
Zurück zum Zitat Svrakic M, Friedmann DR, Berman PM, Davis AJ, Roland JT Jr, Svirsky MA (2015) Measurement of cochlear implant electrode position from intraoperative post-insertion skull radiographs: a validation study. Otol Neurotol 36:1486CrossRef Svrakic M, Friedmann DR, Berman PM, Davis AJ, Roland JT Jr, Svirsky MA (2015) Measurement of cochlear implant electrode position from intraoperative post-insertion skull radiographs: a validation study. Otol Neurotol 36:1486CrossRef
24.
Zurück zum Zitat Rivas A, Cakir A, Hunter JB et al (2017) Automatic cochlear duct length estimation for selection of cochlear implant electrode arrays. Otol Neurotol 38:339–346CrossRef Rivas A, Cakir A, Hunter JB et al (2017) Automatic cochlear duct length estimation for selection of cochlear implant electrode arrays. Otol Neurotol 38:339–346CrossRef
25.
Zurück zum Zitat Iyaniwura JE, Elfarnawany M, Riyahi-Alam S et al (2017) Intra- and interobserver variability of cochlear length measurements in clinical CT. Otol Neurotol 38:828–832CrossRef Iyaniwura JE, Elfarnawany M, Riyahi-Alam S et al (2017) Intra- and interobserver variability of cochlear length measurements in clinical CT. Otol Neurotol 38:828–832CrossRef
26.
Zurück zum Zitat Iyaniwura JE, Elfarnawany M, Ladak HM, Agrawal SK (2018) An automated A-value measurement tool for accurate cochlear duct length estimation. J Otolaryngol Head Neck Surg 47:1–8CrossRef Iyaniwura JE, Elfarnawany M, Ladak HM, Agrawal SK (2018) An automated A-value measurement tool for accurate cochlear duct length estimation. J Otolaryngol Head Neck Surg 47:1–8CrossRef
Metadaten
Titel
Cochlear duct length and cochlear distance on preoperative CT: imaging markers for estimating insertion depth angle of cochlear implant electrode
verfasst von
Jiseon Oh
Jung-Eun Cheon
Junghoan Park
Young Hun Choi
Yeon Jin Cho
Seunghyun Lee
Seung Ha Oh
Su-Mi Shin
Sun-Won Park
Publikationsdatum
20.01.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 3/2021
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-020-07580-4

Weitere Artikel der Ausgabe 3/2021

European Radiology 3/2021 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.