Erschienen in:
01.03.2015 | General Gynecology
Accuracy of magnetic resonance in deeply infiltrating endometriosis: a systematic review and meta-analysis
verfasst von:
Lídia Rossi Medeiros, Maria Inês Rosa, Bruno Rosa Silva, Maria Eduarda Reis, Carla Sasso Simon, Eduardo Ronconi Dondossola, João Sabino da Cunha Filho
Erschienen in:
Archives of Gynecology and Obstetrics
|
Ausgabe 3/2015
Einloggen, um Zugang zu erhalten
Abstract
Objective
To estimate the accuracy of pelvic magnetic resonance imaging (MRI) in the diagnosis of deeply infiltrating endometriosis (DIE).
Methods
A comprehensive search of the Medline, Pubmed, Lilacs, Scopus, Embase, Cochrane Central Register of Controlled Trials (CENTRAL), Biomed Central, and ISI Web of Science databases was conducted from January 1990 to December 2013. The medical subject headings (MeSHs) and text words “deep endometriosis”, “deeply infiltrating endometriosis”, “DIE”, “magnetic resonance”, and “MRI” were searched. Studies that compared the parameters of pelvic MRIs with those of paraffin-embedded sections for the diagnosis of DIE were included.
Results
Twenty studies were analyzed, which included 1,819 women. Pooled sensitivity and specificity were calculated across eight subgroups: for all sites, these were 0.83 and 0.90, respectively; for the bladder, 0.64 and 0.98, respectively; for the intestine, 0.84 and 0.97, respectively; for the pouch of Douglas, 0.89 and 0.94, respectively; for the rectosigmoid, 0.83 and 0.88, respectively; for the rectovaginal, 0.77 and 0.95, respectively; for the uterosacral ligaments, 0.85 and 0.80, respectively; and for the vagina and the posterior vaginal fornix, 0.82 and 0.82, respectively.
Conclusion
In summary, pelvic MRI is a useful preoperative test for predicting the diagnosis of multiple sites of deep infiltrating endometriosis.