Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 12/2005

01.12.2005 | Clinical Investigation

Evaluating reading acuity and speed in children with microstrabismic amblyopia using a standardized reading chart system

verfasst von: E. Stifter, G. Burggasser, E. Hirmann, A. Thaler, W. Radner

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 12/2005

Einloggen, um Zugang zu erhalten

Abstract

Background

To examine if standardized reading charts with highly comparable test items can be used for evaluating impairments in the monocular reading performance of children with microstrabismic amblyopia characterized by a small angle of squint with less than 5 degrees.

Methods

The reading performance of 22 children (mean age: 11.7±1.6 years) with unilateral microstrabismic amblyopia was evaluated monocularly in both eyes, using standardized reading charts for the simultaneous determination of reading acuity and speed. The print sizes of the highly comparable sentence optotypes were logarithmically graded, providing constant geometric proportions for all testing distances in order to control contour interaction. All children were under continuous amblyopia therapy.

Results

In the amblyopic eyes, reading acuity and maximum reading speed were significantly impaired when compared to the sound fellow eyes (P<0.001). In respect of the maximum reading speed, a mean inter-ocular difference of 33±19 words per minute was found, revealing functionally relevant deficits in monocular reading performance. The amblyopic eyes achieved only a significantly reduced reading acuity (mean inter-ocular difference: LogRAD 0.5±0.24; P<0.001). In eight children, the amblyopic eyes achieved a best-corrected visual acuity of LogMAR 0.0 or better: in respect of the visual acuity, there was no significant inter-ocular difference, but reading acuity and maximum reading speed were significantly impaired when compared to the fellow eyes.

Conclusions

Microstrabismic amblyopia was associated with significant impairment of reading acuity and speed in treated amblyopes, even in those with no persistent acuity deficit. To improve treatment addressing these functional deficits, reading performance should be monitored over time using standardized reading tests, which provide essential information about functionally relevant reading impairments.
Literatur
1.
Zurück zum Zitat Bailey IL, Lovie JE (1980) The design and use of a new near-vision chart. Am J Optom Physiol Opt 57:378–387PubMed Bailey IL, Lovie JE (1980) The design and use of a new near-vision chart. Am J Optom Physiol Opt 57:378–387PubMed
2.
Zurück zum Zitat Becker R, Hübsch S, Gräf MH, Kaufmann H (2002) Examination of young children with Lea symbols. Br J Ophthalmol 86:513–516CrossRefPubMed Becker R, Hübsch S, Gräf MH, Kaufmann H (2002) Examination of young children with Lea symbols. Br J Ophthalmol 86:513–516CrossRefPubMed
3.
Zurück zum Zitat Bedell HE, Flom MC, Barbeito R (1985) Spatial aberrations and acuity in strabismus and amblyopia. Invest Ophthalmol Vis Sci 26:909–916PubMed Bedell HE, Flom MC, Barbeito R (1985) Spatial aberrations and acuity in strabismus and amblyopia. Invest Ophthalmol Vis Sci 26:909–916PubMed
4.
Zurück zum Zitat CEN (European Committee of Norms). Europäische Norm Sehschärfenprüfung EN ISO 8596. Beuth-Verlag 1996, Berlin CEN (European Committee of Norms). Europäische Norm Sehschärfenprüfung EN ISO 8596. Beuth-Verlag 1996, Berlin
5.
Zurück zum Zitat Ciuffreda KJ, Kenyon RV, Stark L (1978) Increased saccadic latencies in amblyopic eyes. Invest Ophthalmol Vis Sci 17:697–702PubMed Ciuffreda KJ, Kenyon RV, Stark L (1978) Increased saccadic latencies in amblyopic eyes. Invest Ophthalmol Vis Sci 17:697–702PubMed
6.
Zurück zum Zitat Ciuffreda KJ, Kenyon RV, Stark L (1979) Abnormal saccadic substitution during small-amplitude pursuit tracking in amblyopic eyes. Invest Ophthalmol Vis Sci 18:506–516PubMed Ciuffreda KJ, Kenyon RV, Stark L (1979) Abnormal saccadic substitution during small-amplitude pursuit tracking in amblyopic eyes. Invest Ophthalmol Vis Sci 18:506–516PubMed
7.
Zurück zum Zitat El Mallah MK, Chakravarthy U, Hart PM (2000) Amblyopia: is visual loss permanent? Br J Ophthalmol 84:952–956CrossRefPubMed El Mallah MK, Chakravarthy U, Hart PM (2000) Amblyopia: is visual loss permanent? Br J Ophthalmol 84:952–956CrossRefPubMed
8.
Zurück zum Zitat Ferris F, Kassoff A, Bresnick G, Bailey I (1982) New visual acuity charts for clinical research. Am J Ophthalmol 94:91–96PubMed Ferris F, Kassoff A, Bresnick G, Bailey I (1982) New visual acuity charts for clinical research. Am J Ophthalmol 94:91–96PubMed
9.
Zurück zum Zitat Ferris FL III, Bailey I (1996) Standardizing the measurement of visual acuity for clinical research studies. Guidelines from the eye care technology forum. Ophthalmology 103:181–182PubMed Ferris FL III, Bailey I (1996) Standardizing the measurement of visual acuity for clinical research studies. Guidelines from the eye care technology forum. Ophthalmology 103:181–182PubMed
10.
11.
Zurück zum Zitat Harvey EM, Dobson V, Tung B, Quinn GE, Hardy RJ (1999) Interobserver agreement for grating acuity and letter acuity assessment in 1 to 5.5-year-olds with severe retinopathy of prematurity. Invest Ophthalmol Vis Sci 40:1565–1576PubMed Harvey EM, Dobson V, Tung B, Quinn GE, Hardy RJ (1999) Interobserver agreement for grating acuity and letter acuity assessment in 1 to 5.5-year-olds with severe retinopathy of prematurity. Invest Ophthalmol Vis Sci 40:1565–1576PubMed
12.
Zurück zum Zitat Hess RF, Holliday IE (1992) The spatial localization deficit in amblyopia. Vis Res 32:1319–1339CrossRefPubMed Hess RF, Holliday IE (1992) The spatial localization deficit in amblyopia. Vis Res 32:1319–1339CrossRefPubMed
13.
Zurück zum Zitat Hess RF, Dakin SC, Kapoor N (2000) The foveal “crowding effect”: physics or physiology? Vis Res 40:355–370 Hess RF, Dakin SC, Kapoor N (2000) The foveal “crowding effect”: physics or physiology? Vis Res 40:355–370
14.
Zurück zum Zitat Holm S (1979) A simple sequentially rejective multiple test procedure. Scand J Statist 6:65–70 Holm S (1979) A simple sequentially rejective multiple test procedure. Scand J Statist 6:65–70
17.
Zurück zum Zitat Legge GE, Pelli DG, Rubin GS, Schleske MM (1985) Psychophysics of reading—I. Normal vision. Vis Res 25:239–252CrossRefPubMed Legge GE, Pelli DG, Rubin GS, Schleske MM (1985) Psychophysics of reading—I. Normal vision. Vis Res 25:239–252CrossRefPubMed
18.
Zurück zum Zitat Legge GE, Rubin GS, Pelli DG, Schleske MM (1985) Psychophysics of reading—II. Low vision. Vis Res 25:253–266CrossRefPubMed Legge GE, Rubin GS, Pelli DG, Schleske MM (1985) Psychophysics of reading—II. Low vision. Vis Res 25:253–266CrossRefPubMed
19.
Zurück zum Zitat Mackensen G (1962) Die Untersuchung der Lesefähigkeit als klinische Funktionsprüfung. Fortschr Augenheilk 12:344–379 Mackensen G (1962) Die Untersuchung der Lesefähigkeit als klinische Funktionsprüfung. Fortschr Augenheilk 12:344–379
20.
Zurück zum Zitat Manny RE, Hussein M, Gwiazda J, Marsh-Tootle W, COMET Study Group (2003) Repeatability of ETDRS visual acuity in children. Invest Ophthalmol Vis Sci 44:3294–3300CrossRefPubMed Manny RE, Hussein M, Gwiazda J, Marsh-Tootle W, COMET Study Group (2003) Repeatability of ETDRS visual acuity in children. Invest Ophthalmol Vis Sci 44:3294–3300CrossRefPubMed
21.
Zurück zum Zitat Mansfield J, Ahn S, Legge G, Luebker A (1993) A new reading-acuity chart for normal and low vision. Opt Soc Am Techn Digest 3:232–235 Mansfield J, Ahn S, Legge G, Luebker A (1993) A new reading-acuity chart for normal and low vision. Opt Soc Am Techn Digest 3:232–235
22.
Zurück zum Zitat NAS-NRC Committee on Vision (1980) Recommended standard procedures for the clinical measurement and specification of visual acuity. Adv Ophthalmol 41:103–148 NAS-NRC Committee on Vision (1980) Recommended standard procedures for the clinical measurement and specification of visual acuity. Adv Ophthalmol 41:103–148
23.
Zurück zum Zitat Ohlsson J, Baumann M, Sjörstrand J, Abrahamsson M (2002) Long term visual outcome in amblyopia treatment. Br J Ophthalmol 86:1148–1151CrossRefPubMed Ohlsson J, Baumann M, Sjörstrand J, Abrahamsson M (2002) Long term visual outcome in amblyopia treatment. Br J Ophthalmol 86:1148–1151CrossRefPubMed
24.
Zurück zum Zitat Radner W, Willinger U, Obermayer W, Mudrich C, Velikay-Parel M, Eisenwort B (1998) Eine neue Lesetafel zur gleichzeitigen Bestimmung von Lesevisus und Lesegeschwindigkeit. Klin Monatsbl Augenheilkd 213:174–181PubMed Radner W, Willinger U, Obermayer W, Mudrich C, Velikay-Parel M, Eisenwort B (1998) Eine neue Lesetafel zur gleichzeitigen Bestimmung von Lesevisus und Lesegeschwindigkeit. Klin Monatsbl Augenheilkd 213:174–181PubMed
25.
Zurück zum Zitat Radner W, Obermayer W, Richter-Mueksch S, Willinger U, Velikay-Parel M, Eisenwort B (2002) The validity and reliability of short German sentences for measuring reading speed. Graefe Arch Clin Exp Ophthalmol 240:461–467CrossRef Radner W, Obermayer W, Richter-Mueksch S, Willinger U, Velikay-Parel M, Eisenwort B (2002) The validity and reliability of short German sentences for measuring reading speed. Graefe Arch Clin Exp Ophthalmol 240:461–467CrossRef
26.
Zurück zum Zitat Rassow B, Wang Y (1999) Anschluß von Buchstaben-Optotypen an den Landolt-Ring für verschiedene Bereiche der Sehschärfe. Klin Monatsbl Augenheilkd 215:119–126PubMedCrossRef Rassow B, Wang Y (1999) Anschluß von Buchstaben-Optotypen an den Landolt-Ring für verschiedene Bereiche der Sehschärfe. Klin Monatsbl Augenheilkd 215:119–126PubMedCrossRef
27.
Zurück zum Zitat Rice ML, Leske DA, Holmes JM (2004) Comparison of the Amblyopia Treatment Study HOTV and Electronic-Early Treatment of Diabetic Retinopathy Study Visual Acuity Protocols in children aged 5 to 12 years. Am J Ophthalmol 137:278–282CrossRefPubMed Rice ML, Leske DA, Holmes JM (2004) Comparison of the Amblyopia Treatment Study HOTV and Electronic-Early Treatment of Diabetic Retinopathy Study Visual Acuity Protocols in children aged 5 to 12 years. Am J Ophthalmol 137:278–282CrossRefPubMed
28.
Zurück zum Zitat Schor C, Hallmark W (1978) Slow control of eye position in strabismic amblyopia. Invest Ophthalmol Vis Sci 17:577–581PubMed Schor C, Hallmark W (1978) Slow control of eye position in strabismic amblyopia. Invest Ophthalmol Vis Sci 17:577–581PubMed
29.
Zurück zum Zitat Simmers AJ, Gray LS, McGraw PV, Winn B (1999) Contour interaction for high and low contrast optotypes in normal and amblyopic observers. Ophthal Physiol Opt 19:253–260CrossRef Simmers AJ, Gray LS, McGraw PV, Winn B (1999) Contour interaction for high and low contrast optotypes in normal and amblyopic observers. Ophthal Physiol Opt 19:253–260CrossRef
30.
Zurück zum Zitat Simmers AJ, Gray LS, McGraw PV, Winn B (1999) Functional visual loss in amblyopia and the effect of occlusion treatment. Invest Ophthalmol Vis Sci 40:2859–2871PubMed Simmers AJ, Gray LS, McGraw PV, Winn B (1999) Functional visual loss in amblyopia and the effect of occlusion treatment. Invest Ophthalmol Vis Sci 40:2859–2871PubMed
31.
Zurück zum Zitat Stifter E, König F, Lang T, Bauer P, Richter-Müksch S, Velikay-Parel M, Radner W (2004) Reliability of a standardized reading chart system: variance component analysis, test-retest and inter-chart reliability. Graefe Arch Clin Exp Ophthalmol 242:31–39CrossRef Stifter E, König F, Lang T, Bauer P, Richter-Müksch S, Velikay-Parel M, Radner W (2004) Reliability of a standardized reading chart system: variance component analysis, test-retest and inter-chart reliability. Graefe Arch Clin Exp Ophthalmol 242:31–39CrossRef
32.
Zurück zum Zitat Stifter E, Sacu S, Weghaupt H, König F, Richter-Müksch S, Thaler A, Velikay-Parel M, Radner W (2004) Reading performance in dependency of the type of cataract and its predictability on the visual outcome. J Cataract Refract Surg 30:1259–1267CrossRefPubMed Stifter E, Sacu S, Weghaupt H, König F, Richter-Müksch S, Thaler A, Velikay-Parel M, Radner W (2004) Reading performance in dependency of the type of cataract and its predictability on the visual outcome. J Cataract Refract Surg 30:1259–1267CrossRefPubMed
33.
Zurück zum Zitat Zhang J, Quan H, Ng J, Stepanavage ME (1997) Some statistical methods for multiple endpoints of clinical trials. Control Clin Trials 18:204–221CrossRefPubMed Zhang J, Quan H, Ng J, Stepanavage ME (1997) Some statistical methods for multiple endpoints of clinical trials. Control Clin Trials 18:204–221CrossRefPubMed
34.
Zurück zum Zitat Zurcher B, Lang J (1980) Reading capacity in cases of ‘cured’ strabismic amblyopia. Trans Ophthalmol Soc UK 100:501–503PubMed Zurcher B, Lang J (1980) Reading capacity in cases of ‘cured’ strabismic amblyopia. Trans Ophthalmol Soc UK 100:501–503PubMed
Metadaten
Titel
Evaluating reading acuity and speed in children with microstrabismic amblyopia using a standardized reading chart system
verfasst von
E. Stifter
G. Burggasser
E. Hirmann
A. Thaler
W. Radner
Publikationsdatum
01.12.2005
Verlag
Springer-Verlag
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 12/2005
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-005-1187-9

Weitere Artikel der Ausgabe 12/2005

Graefe's Archive for Clinical and Experimental Ophthalmology 12/2005 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.