Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 10/2006

01.10.2006 | Clinical Investigation

K-Train–a computer-based, interactive training program with an incorporated certification system for practicing kinetic perimetry: evaluation of acceptance and success rate

verfasst von: U. Schiefer, K. Nowomiejska, E. Krapp, J. Pätzold, C. A. Johnson

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 10/2006

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate, in an experimental study, an interactive, computer-based teaching procedure for kinetic perimetry that incorporates an evaluation system for scoring examination technique.

Methods and subjects

K-Train was developed and based on the original user interface of the new semi-automated kinetic perimetry (SKP) feature of the OCTOPUS 101 perimeter (HAAG-STREIT, Koeniz, Switzerland). The trainer creates a 3D individual “hill of vision” for a specific pathology and the trainee can individually select target characteristics and independently define origin, end and direction of each kinetic stimulus with the help of vectors. Quality of the perimetric examination can be quantitatively assessed by the ratio of intersection area and union area of the trainee’s result and the related trainer-defined original isopter. This ratio and other parameters are used to define a score of “perimetric quality”. The general acceptance of K-Train was assessed in 30 participants in two perimetric courses. The success rate was examined by comparing the scores before and after a perimetric training session.

Results

The K-Train course was graded by the participants with an average score of 1.35 (range 1–3) in a scoring system ranging from 1=excellent to 6=unsatisfactory. The average perimetric quality score increased from 48 before to 59 (max. 100) after the training (27 trainees) indicating that K-Train was able to achieve and also verify a considerable success rate.

Conclusion

The acceptance of K-Train, a computer-based, interactive tool that allows for certification, education and quality control of kinetic perimetry, is high. K-Train is capable of improving a trainee’s individual performance in kinetic perimetry and of verifying this by an appropriate scoring system.
Literatur
1.
Zurück zum Zitat Anderson DR (1982) Testing the field of vision. Mosby, St. Louis Anderson DR (1982) Testing the field of vision. Mosby, St. Louis
2.
Zurück zum Zitat Canadian Medical Association (1992) Physicians’ guide to driver examination. Canadian Medical Association, Ottawa Canadian Medical Association (1992) Physicians’ guide to driver examination. Canadian Medical Association, Ottawa
3.
Zurück zum Zitat Egge K (1984) The visual field in normal subjects. Acta Ophthalmol Suppl 169:1–64PubMed Egge K (1984) The visual field in normal subjects. Acta Ophthalmol Suppl 169:1–64PubMed
4.
Zurück zum Zitat Ferree CE, Rand G, Monroe MM (1931) Diagnostic scales for the 1 degree and 0.17 degree form field stimuli for the eight principal meridional quadrants taken separately. Arch Ophthalmol 6:518–534 Ferree CE, Rand G, Monroe MM (1931) Diagnostic scales for the 1 degree and 0.17 degree form field stimuli for the eight principal meridional quadrants taken separately. Arch Ophthalmol 6:518–534
5.
Zurück zum Zitat Goldmann H (1945) Grundlagen exakter Perimetrie. Ophthal 109:57–70 Goldmann H (1945) Grundlagen exakter Perimetrie. Ophthal 109:57–70
6.
Zurück zum Zitat Goldmann H (1946) Demonstration unseres neuen Projektionskugelperimeters samt theoretischen und klinischen Bemerkungen über Perimetrie. Opthalmologica 11:187–192CrossRef Goldmann H (1946) Demonstration unseres neuen Projektionskugelperimeters samt theoretischen und klinischen Bemerkungen über Perimetrie. Opthalmologica 11:187–192CrossRef
7.
Zurück zum Zitat Hulbert MFG (1992) Passing the DVLC field regulations following bilateral pan-retinal photocoagulation in diabetics. Eye 6:456–460PubMed Hulbert MFG (1992) Passing the DVLC field regulations following bilateral pan-retinal photocoagulation in diabetics. Eye 6:456–460PubMed
8.
Zurück zum Zitat Johnson CA, Keltner JL (1987) Optimal rates of movement for kinetic perimetry. Arch Ophthalmol 105:73–75PubMed Johnson CA, Keltner JL (1987) Optimal rates of movement for kinetic perimetry. Arch Ophthalmol 105:73–75PubMed
9.
Zurück zum Zitat Keltner JL, Johnson CA, Spurr JO, Beck RW (1999) Comparison of central and peripheral visual field properties in the Optic Neuritis Treatment Trial (ONTT). Am J Ophthalmol 128:543–553PubMedCrossRef Keltner JL, Johnson CA, Spurr JO, Beck RW (1999) Comparison of central and peripheral visual field properties in the Optic Neuritis Treatment Trial (ONTT). Am J Ophthalmol 128:543–553PubMedCrossRef
10.
Zurück zum Zitat Nowomiejska KE, Vonthein R, Krapp E, Rauscher S, Hermann A, Paetzold J, Schiefer U (2003) High resolution assessment of kinetic isopters on the stimulus size and luminance response surface. Invest Ophthalmol Vis Sci 44 (Suppl):E 1955 Nowomiejska KE, Vonthein R, Krapp E, Rauscher S, Hermann A, Paetzold J, Schiefer U (2003) High resolution assessment of kinetic isopters on the stimulus size and luminance response surface. Invest Ophthalmol Vis Sci 44 (Suppl):E 1955
11.
Zurück zum Zitat Paetzold J, Schiller J, Rauscher S, Schiefer U (2003) A computer application for training kinetic perimetry. In: Wall M, Mills RP (eds) Perimetry update 2002/2003. Kugler, The Hague, pp 69–73 Paetzold J, Schiller J, Rauscher S, Schiefer U (2003) A computer application for training kinetic perimetry. In: Wall M, Mills RP (eds) Perimetry update 2002/2003. Kugler, The Hague, pp 69–73
12.
Zurück zum Zitat Parisi JL, Bell RA, Yassein H (1991) Homonymous hemianoptic field defects and driving in Canada. Can J Optom 26:252–256 Parisi JL, Bell RA, Yassein H (1991) Homonymous hemianoptic field defects and driving in Canada. Can J Optom 26:252–256
13.
Zurück zum Zitat Parrish RK, Schiffman J, Anderson DR (1984) Static and kinetic visual field testing-reproducibility in normal volunteers. Arch Ophthalmol 102:1497–1502PubMed Parrish RK, Schiffman J, Anderson DR (1984) Static and kinetic visual field testing-reproducibility in normal volunteers. Arch Ophthalmol 102:1497–1502PubMed
14.
Zurück zum Zitat Rauscher S, Vonthein R, Sadowski B, Erdmann B, Krapp E, Schiefer U (2002) Computer-assisted kinetic perimetry (CAKP) Using the Octopus 101 perimeter: age related normal values of local thresholds using various stimulus conditions and considering individual reaction times. Invest Ophthalmol Vis Sci 43 (12) (Suppl):3810 Rauscher S, Vonthein R, Sadowski B, Erdmann B, Krapp E, Schiefer U (2002) Computer-assisted kinetic perimetry (CAKP) Using the Octopus 101 perimeter: age related normal values of local thresholds using various stimulus conditions and considering individual reaction times. Invest Ophthalmol Vis Sci 43 (12) (Suppl):3810
15.
Zurück zum Zitat Schiefer U, Rauscher S, Hermann A, Nowomiejska KE, Sadowski B, Vonthein R, Paetzold J, Schiller J (2003) Age dependence of normative values in semi-automated kinetic perimetry (SKP) reviewing. Invest Ophthalmol Vis Sci 44 (Suppl):E-1957 Schiefer U, Rauscher S, Hermann A, Nowomiejska KE, Sadowski B, Vonthein R, Paetzold J, Schiller J (2003) Age dependence of normative values in semi-automated kinetic perimetry (SKP) reviewing. Invest Ophthalmol Vis Sci 44 (Suppl):E-1957
16.
Zurück zum Zitat Schiefer U, Rauscher S, Paetzold J, Schiller J (2003) Realization of semi-automated kinetic perimetry (SKP) with the Interzeag 101 instrument. In: Wall M, Mills RP (eds) Perimetry update 2002/2003. Kugler, The Hague, pp 233–238 Schiefer U, Rauscher S, Paetzold J, Schiller J (2003) Realization of semi-automated kinetic perimetry (SKP) with the Interzeag 101 instrument. In: Wall M, Mills RP (eds) Perimetry update 2002/2003. Kugler, The Hague, pp 233–238
17.
Zurück zum Zitat Schiefer U, Schiller J, Dietrich TJ, Besch D, Paetzold J, Vonthein R (2001) Evaluation of advanced visual field loss with computer-assisted kinetic perimetry. In: Wall M, Mills RP (eds) Perimetry update 2000/2001. Kugler, The Hague, pp 131–136 Schiefer U, Schiller J, Dietrich TJ, Besch D, Paetzold J, Vonthein R (2001) Evaluation of advanced visual field loss with computer-assisted kinetic perimetry. In: Wall M, Mills RP (eds) Perimetry update 2000/2001. Kugler, The Hague, pp 131–136
18.
Zurück zum Zitat Schiefer U, Schiller J, Paetzold J, Dietrich TJ, Vonthein R, Besch D (2001) Evaluation ausgedehnter Gesichtsfelddefekte mittels computerassistierter kinetischer Perimetrie. Klin Monatsbl Augenheilkd 218:13–20PubMedCrossRef Schiefer U, Schiller J, Paetzold J, Dietrich TJ, Vonthein R, Besch D (2001) Evaluation ausgedehnter Gesichtsfelddefekte mittels computerassistierter kinetischer Perimetrie. Klin Monatsbl Augenheilkd 218:13–20PubMedCrossRef
19.
Zurück zum Zitat Shapiro LR, Johnson CA (1990) Quantitative evaluation of manual kinetic perimetry using computer simulation. Applied Optics 29:1445–1450CrossRef Shapiro LR, Johnson CA (1990) Quantitative evaluation of manual kinetic perimetry using computer simulation. Applied Optics 29:1445–1450CrossRef
20.
Zurück zum Zitat Shapiro LR, Johnson CA (1991) Evaluation of the diagnosis of visual fields. Perimetry Update 281–285 Shapiro LR, Johnson CA (1991) Evaluation of the diagnosis of visual fields. Perimetry Update 281–285
21.
Zurück zum Zitat Shapiro LR, Johnson CA, Kennedy RL (1989) KRAKEN. A computer simulation procedure for static, kinetic, suprathreshold static and heuristic perimetry. In: Heijl A (ed) Perimetry update 1988/89. Proceedings of the VIIIth International Perimetric Society Meeting. Kugler & Ghedini, Amsterdam Shapiro LR, Johnson CA, Kennedy RL (1989) KRAKEN. A computer simulation procedure for static, kinetic, suprathreshold static and heuristic perimetry. In: Heijl A (ed) Perimetry update 1988/89. Proceedings of the VIIIth International Perimetric Society Meeting. Kugler & Ghedini, Amsterdam
22.
Zurück zum Zitat Verkehrskommission der DOG (2003) Empfehlung der Deutschen Ophthalmologischen Gesellschaft und des Berufsverbandes der Augenärzte Deutschlands zur Fahreignungsbegutachtung für den Straβenverkehr. BVA Verkehrskommission der DOG (2003) Empfehlung der Deutschen Ophthalmologischen Gesellschaft und des Berufsverbandes der Augenärzte Deutschlands zur Fahreignungsbegutachtung für den Straβenverkehr. BVA
23.
Zurück zum Zitat Wabbels BK, Kolling G (1999) Automatische kinetische Perimetrie mit dem Twinfield-Perimeter. Z Prakt Augenheilkd 20:401–406 Wabbels BK, Kolling G (1999) Automatische kinetische Perimetrie mit dem Twinfield-Perimeter. Z Prakt Augenheilkd 20:401–406
24.
Zurück zum Zitat Wabbels BK, Kolling G (2001) Automatische kinetische Perimetrie mit unterschiedlichen Prüfgeschwindigkeiten. Ophthalmologe 98:168–173PubMedCrossRef Wabbels BK, Kolling G (2001) Automatische kinetische Perimetrie mit unterschiedlichen Prüfgeschwindigkeiten. Ophthalmologe 98:168–173PubMedCrossRef
25.
Zurück zum Zitat Williams TD (1983) Computer-based analysis of visual fields: age-related norms for the central visual field. Can J Optom 45:166–170 Williams TD (1983) Computer-based analysis of visual fields: age-related norms for the central visual field. Can J Optom 45:166–170
26.
Zurück zum Zitat Williams TD (1985) Age-related norms for the periphal visual field. Can J Optom 47:140–141CrossRef Williams TD (1985) Age-related norms for the periphal visual field. Can J Optom 47:140–141CrossRef
27.
Zurück zum Zitat Williams TD (1997) Goldmann visual field norms for age groups 25 to 75 years: I-1, III-3 and III-4 targets. Can J Optom 58:170–175 Williams TD (1997) Goldmann visual field norms for age groups 25 to 75 years: I-1, III-3 and III-4 targets. Can J Optom 58:170–175
28.
Zurück zum Zitat Zehnder-Albrecht S (1950) Zur Standardisierung der Perimetrie. Ophthal 120:255–270 Zehnder-Albrecht S (1950) Zur Standardisierung der Perimetrie. Ophthal 120:255–270
Metadaten
Titel
K-Train–a computer-based, interactive training program with an incorporated certification system for practicing kinetic perimetry: evaluation of acceptance and success rate
verfasst von
U. Schiefer
K. Nowomiejska
E. Krapp
J. Pätzold
C. A. Johnson
Publikationsdatum
01.10.2006
Verlag
Springer-Verlag
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 10/2006
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-006-0291-9

Weitere Artikel der Ausgabe 10/2006

Graefe's Archive for Clinical and Experimental Ophthalmology 10/2006 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.