Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 6/2013

01.06.2013 | Retinal Disorders

Inverse relationship between macular pigment optical density and axial length in Chinese subjects with myopia

verfasst von: Nianting Tong, Wei Zhang, Zhenzhen Zhang, Yuanyuan Gong, Billy Wooten, Xingwei Wu

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 6/2013

Einloggen, um Zugang zu erhalten

Abstract

Background

Macular pigment (MP) has been the focus of much attention in recent years, due to its protective effect against macular degenerations. In this study, we investigated the association between macular pigment optical density (MPOD) and axial length (AL) in Chinese subjects with myopia.

Methods

In total, 173 myopes (mean spherical equivalent [MSE] ≤ -1.00D) were recruited for this prospective observational study. MPOD was measured in both eyes of each subject using a macular metrics densitometer. AL was measured in eyes using an IOL-Master. A raw coefficient of correlation analysis and a partial correlation analysis were used to investigate the relationship between MPOD and AL.

Results

The age of the subjects ranged from 18 to 67 years. The overall mean MPOD for the cohort was 0.412 ± 0.119 (range, 0.105–0.812). The mean AL was 25.18 ± 1.08 mm (range, 23.14–28.19 mm). Using a raw coefficient of correlation, a significant inverse correlation was found between MPOD and AL (r = −0.134, p = 0.012). When using a partial correlation analysis to eliminate the impact of covariant, a significant inverse correlation was also found between MPOD and AL (r = −0.142, p = 0.008). Furthermore, when AL was divided into two groups: AL > 26 mm and AL ≤ 26 mm, a significant inverse correlation was observed between MPOD and AL in the former (r = −0.253, p = 0.029), but no significant relationship was observed between these in the latter (r = 0.104, p = 0.067).

Conclusions

MPOD correlated inversely with AL in this sample of Chinese subjects with myopia.
Literatur
2.
Zurück zum Zitat Loane E, Nolan JM, Beatty S (2010) The respective relationships between lipoprotein profile, macular pigment optical density, and serum concentrations of lutein and zeaxanthin. Invest Ophthalmol Vis Sci 51:5897–5905PubMedCrossRef Loane E, Nolan JM, Beatty S (2010) The respective relationships between lipoprotein profile, macular pigment optical density, and serum concentrations of lutein and zeaxanthin. Invest Ophthalmol Vis Sci 51:5897–5905PubMedCrossRef
3.
Zurück zum Zitat Snodderly DM, Auran JD, Delori FC (1984) The macular pigment. II. Spatial distribution in primate retinas. Invest Ophthalmol Vis Sci 25:674–685PubMed Snodderly DM, Auran JD, Delori FC (1984) The macular pigment. II. Spatial distribution in primate retinas. Invest Ophthalmol Vis Sci 25:674–685PubMed
4.
Zurück zum Zitat Bone RA, Landrum JT, Friedes LM, Gomez CM, Kilburn MD, Menendez E, Vidal I, Wang W (1997) Distribution of lutein and zeaxanthin stereoisomers in the human retina. Exp Eye Res 64:211–218PubMedCrossRef Bone RA, Landrum JT, Friedes LM, Gomez CM, Kilburn MD, Menendez E, Vidal I, Wang W (1997) Distribution of lutein and zeaxanthin stereoisomers in the human retina. Exp Eye Res 64:211–218PubMedCrossRef
5.
Zurück zum Zitat Johnson EJ, Neuringer M, Russell RM, Schalch W, Snodderly DM (2005) Nutritional manipulation of primate retinas, III: Effects of lutein or zeaxanthin supplementation on adipose tissue and retina of xanthophyll-free monkeys. Invest Ophthalmol Vis Sci 46:692–702PubMedCrossRef Johnson EJ, Neuringer M, Russell RM, Schalch W, Snodderly DM (2005) Nutritional manipulation of primate retinas, III: Effects of lutein or zeaxanthin supplementation on adipose tissue and retina of xanthophyll-free monkeys. Invest Ophthalmol Vis Sci 46:692–702PubMedCrossRef
6.
Zurück zum Zitat Khachik F, Bernstein PS, Garland DL (1997) Identification of lutein and zeaxanthin oxidation products in human and monkey retinas. Invest Ophthalmol Vis Sci 38:1802–1811PubMed Khachik F, Bernstein PS, Garland DL (1997) Identification of lutein and zeaxanthin oxidation products in human and monkey retinas. Invest Ophthalmol Vis Sci 38:1802–1811PubMed
7.
Zurück zum Zitat Snodderly DM (1995) Evidence for protection against age-related macular degeneration by carotenoids and antioxidant vitamins. Am J Clin Nutr 62:1448S–1461SPubMed Snodderly DM (1995) Evidence for protection against age-related macular degeneration by carotenoids and antioxidant vitamins. Am J Clin Nutr 62:1448S–1461SPubMed
8.
Zurück zum Zitat Beatty S, Murray IJ, Henson DB, Carden D, Koh H, Boulton ME (2001) Macular pigment and risk for age-related macular degeneration in subjects from a Northern European population. Invest Ophthalmol Vis Sci 42:439–446PubMed Beatty S, Murray IJ, Henson DB, Carden D, Koh H, Boulton ME (2001) Macular pigment and risk for age-related macular degeneration in subjects from a Northern European population. Invest Ophthalmol Vis Sci 42:439–446PubMed
9.
Zurück zum Zitat Kilbride PE, Fishman M, Fishman GA, Hutman LP (1986) Foveal cone pigment density difference and reflectance in retinitis pigmentosa. Arch Ophthalmol 104:220–224PubMedCrossRef Kilbride PE, Fishman M, Fishman GA, Hutman LP (1986) Foveal cone pigment density difference and reflectance in retinitis pigmentosa. Arch Ophthalmol 104:220–224PubMedCrossRef
10.
Zurück zum Zitat Kempen JH, Mitchell P, Lee KE, Tielsch JM, Broman AT, Taylor HR, Ikram MK, Congdon NG, O’Colmain BJ (2004) The prevalence of refractive errors among adults in the United States, Western Europe, and Australia. Arch Ophthalmol 122:495–505PubMedCrossRef Kempen JH, Mitchell P, Lee KE, Tielsch JM, Broman AT, Taylor HR, Ikram MK, Congdon NG, O’Colmain BJ (2004) The prevalence of refractive errors among adults in the United States, Western Europe, and Australia. Arch Ophthalmol 122:495–505PubMedCrossRef
11.
Zurück zum Zitat Sawada A, Tomidokoro A, Araie M, Iwase A, Yamamoto T (2008) Refractive errors in an elderly Japanese population: the Tajimi study. Ophthalmology 115(363–370):e363CrossRef Sawada A, Tomidokoro A, Araie M, Iwase A, Yamamoto T (2008) Refractive errors in an elderly Japanese population: the Tajimi study. Ophthalmology 115(363–370):e363CrossRef
12.
Zurück zum Zitat Lim MC, Hoh ST, Foster PJ, Lim TH, Chew SJ, Seah SK, Aung T (2005) Use of optical coherence tomography to assess variations in macular retinal thickness in myopia. Invest Ophthalmol Vis Sci 46:974–978PubMedCrossRef Lim MC, Hoh ST, Foster PJ, Lim TH, Chew SJ, Seah SK, Aung T (2005) Use of optical coherence tomography to assess variations in macular retinal thickness in myopia. Invest Ophthalmol Vis Sci 46:974–978PubMedCrossRef
13.
Zurück zum Zitat Wakitani Y, Sasoh M, Sugimoto M, Ito Y, Ido M, Uji Y (2003) Macular thickness measurements in healthy subjects with different axial lengths using optical coherence tomography. Retina 23:177–182PubMedCrossRef Wakitani Y, Sasoh M, Sugimoto M, Ito Y, Ido M, Uji Y (2003) Macular thickness measurements in healthy subjects with different axial lengths using optical coherence tomography. Retina 23:177–182PubMedCrossRef
14.
Zurück zum Zitat Zou H, Zhang X, Xu X, Yu S (2006) Quantitative in vivo retinal thickness measurement in chinese healthy subjects with retinal thickness analyzer. Invest Ophthalmol Vis Sci 47:341–347PubMedCrossRef Zou H, Zhang X, Xu X, Yu S (2006) Quantitative in vivo retinal thickness measurement in chinese healthy subjects with retinal thickness analyzer. Invest Ophthalmol Vis Sci 47:341–347PubMedCrossRef
15.
Zurück zum Zitat Liew SH, Gilbert CE, Spector TD, Mellerio J, Van Kuijk FJ, Beatty S, Fitzke F, Marshall J, Hammond CJ (2006) Central retinal thickness is positively correlated with macular pigment optical density. Exp Eye Res 82:915–920PubMedCrossRef Liew SH, Gilbert CE, Spector TD, Mellerio J, Van Kuijk FJ, Beatty S, Fitzke F, Marshall J, Hammond CJ (2006) Central retinal thickness is positively correlated with macular pigment optical density. Exp Eye Res 82:915–920PubMedCrossRef
16.
Zurück zum Zitat Lam DS, Leung KS, Mohamed S, Chan WM, Palanivelu MS, Cheung CY, Li EY, Lai RY, Leung CK (2007) Regional variations in the relationship between macular thickness measurements and myopia. Invest Ophthalmol Vis Sci 48:376–382PubMedCrossRef Lam DS, Leung KS, Mohamed S, Chan WM, Palanivelu MS, Cheung CY, Li EY, Lai RY, Leung CK (2007) Regional variations in the relationship between macular thickness measurements and myopia. Invest Ophthalmol Vis Sci 48:376–382PubMedCrossRef
17.
Zurück zum Zitat Song WK, Lee SC, Lee ES, Kim CY, Kim SS (2010) Macular thickness variations with sex, age, and axial length in healthy subjects: a spectral domain-optical coherence tomography study. Invest Ophthalmol Vis Sci 51:3913–3918PubMedCrossRef Song WK, Lee SC, Lee ES, Kim CY, Kim SS (2010) Macular thickness variations with sex, age, and axial length in healthy subjects: a spectral domain-optical coherence tomography study. Invest Ophthalmol Vis Sci 51:3913–3918PubMedCrossRef
18.
Zurück zum Zitat Duan XR, Liang YB, Friedman DS, Sun LP, Wong TY, Tao QS, Bao L, Wang NL, Wang JJ (2010) Normal macular thickness measurements using optical coherence tomography in healthy eyes of adult Chinese persons: the Handan Eye Study. Ophthalmology 117:1585–1594PubMedCrossRef Duan XR, Liang YB, Friedman DS, Sun LP, Wong TY, Tao QS, Bao L, Wang NL, Wang JJ (2010) Normal macular thickness measurements using optical coherence tomography in healthy eyes of adult Chinese persons: the Handan Eye Study. Ophthalmology 117:1585–1594PubMedCrossRef
19.
Zurück zum Zitat Aleman TS, Duncan JL, Bieber ML, de Castro E, Marks DA, Gardner LM, Steinberg JD, Cideciyan AV, Maguire MG, Jacobson SG (2001) Macular pigment and lutein supplementation in retinitis pigmentosa and Usher syndrome. Invest Ophthalmol Vis Sci 42:1873–1881PubMed Aleman TS, Duncan JL, Bieber ML, de Castro E, Marks DA, Gardner LM, Steinberg JD, Cideciyan AV, Maguire MG, Jacobson SG (2001) Macular pigment and lutein supplementation in retinitis pigmentosa and Usher syndrome. Invest Ophthalmol Vis Sci 42:1873–1881PubMed
20.
Zurück zum Zitat van der Veen RL, Ostendorf S, Hendrikse F, Berendschot TT (2009) Macular pigment optical density relates to foveal thickness. Eur J Ophthalmol 19:836–841PubMed van der Veen RL, Ostendorf S, Hendrikse F, Berendschot TT (2009) Macular pigment optical density relates to foveal thickness. Eur J Ophthalmol 19:836–841PubMed
21.
Zurück zum Zitat Hammond BR Jr, Wooten BR, Smollon B (2005) Assessment of the validity of in vivo methods of measuring human macular pigment optical density. Optom Vis Sci 82:387–404PubMedCrossRef Hammond BR Jr, Wooten BR, Smollon B (2005) Assessment of the validity of in vivo methods of measuring human macular pigment optical density. Optom Vis Sci 82:387–404PubMedCrossRef
22.
Zurück zum Zitat Mellerio J, Ahmadi-Lari S, van Kuijk F, Pauleikhoff D, Bird A, Marshall J (2002) A portable instrument for measuring macular pigment with central fixation. Curr Eye Res 25:37–47PubMedCrossRef Mellerio J, Ahmadi-Lari S, van Kuijk F, Pauleikhoff D, Bird A, Marshall J (2002) A portable instrument for measuring macular pigment with central fixation. Curr Eye Res 25:37–47PubMedCrossRef
23.
Zurück zum Zitat Loane E, Stack J, Beatty S, Nolan JM (2007) Measurement of macular pigment optical density using two different heterochromatic flicker photometers. Curr Eye Res 32:555–564PubMedCrossRef Loane E, Stack J, Beatty S, Nolan JM (2007) Measurement of macular pigment optical density using two different heterochromatic flicker photometers. Curr Eye Res 32:555–564PubMedCrossRef
24.
Zurück zum Zitat Bone RA, Landrum JT, Cains A (1992) Optical density spectra of the macular pigment in vivo and in vitro. Vision Res 32:105–110PubMedCrossRef Bone RA, Landrum JT, Cains A (1992) Optical density spectra of the macular pigment in vivo and in vitro. Vision Res 32:105–110PubMedCrossRef
25.
Zurück zum Zitat Drexler W, Findl O, Menapace R, Rainer G, Vass C, Hitzenberger CK, Fercher AF (1998) Partial coherence interferometry: a novel approach to biometry in cataract surgery. Am J Ophthalmol 126:524–534PubMedCrossRef Drexler W, Findl O, Menapace R, Rainer G, Vass C, Hitzenberger CK, Fercher AF (1998) Partial coherence interferometry: a novel approach to biometry in cataract surgery. Am J Ophthalmol 126:524–534PubMedCrossRef
26.
Zurück zum Zitat Haigis W, Lege B, Miller N, Schneider B (2000) Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 238:765–773PubMedCrossRef Haigis W, Lege B, Miller N, Schneider B (2000) Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol 238:765–773PubMedCrossRef
27.
Zurück zum Zitat Schmitz-Valckenberg S, Holz FG, Bird AC, Spaide RF (2008) Fundus autofluorescence imaging: review and perspectives. Retina 28:385–409PubMedCrossRef Schmitz-Valckenberg S, Holz FG, Bird AC, Spaide RF (2008) Fundus autofluorescence imaging: review and perspectives. Retina 28:385–409PubMedCrossRef
28.
Zurück zum Zitat Berendschot TT, van Norren D (2004) Objective determination of the macular pigment optical density using fundus reflectance spectroscopy. Arch Biochem Biophys 430:149–155PubMedCrossRef Berendschot TT, van Norren D (2004) Objective determination of the macular pigment optical density using fundus reflectance spectroscopy. Arch Biochem Biophys 430:149–155PubMedCrossRef
29.
Zurück zum Zitat Berendschot TT, Goldbohm RA, Klopping WA, van de Kraats J, van Norel J, van Norren D (2000) Influence of lutein supplementation on macular pigment, assessed with two objective techniques. Invest Ophthalmol Vis Sci 41:3322–3326PubMed Berendschot TT, Goldbohm RA, Klopping WA, van de Kraats J, van Norel J, van Norren D (2000) Influence of lutein supplementation on macular pigment, assessed with two objective techniques. Invest Ophthalmol Vis Sci 41:3322–3326PubMed
30.
Zurück zum Zitat Obana A, Tanito M, Gohto Y, Gellermann W, Okazaki S, Ohira A (2011) Macular pigment changes in pseudophakic eyes quantified with resonance Raman spectroscopy. Ophthalmology 118:1852–1858PubMedCrossRef Obana A, Tanito M, Gohto Y, Gellermann W, Okazaki S, Ohira A (2011) Macular pigment changes in pseudophakic eyes quantified with resonance Raman spectroscopy. Ophthalmology 118:1852–1858PubMedCrossRef
31.
Zurück zum Zitat Hogg RE, Anderson RS, Stevenson MR, Zlatkova MB, Chakravarthy U (2007) In vivo macular pigment measurements: a comparison of resonance Raman spectroscopy and heterochromatic flicker photometry. Br J Ophthalmol 91:485–490PubMedCrossRef Hogg RE, Anderson RS, Stevenson MR, Zlatkova MB, Chakravarthy U (2007) In vivo macular pigment measurements: a comparison of resonance Raman spectroscopy and heterochromatic flicker photometry. Br J Ophthalmol 91:485–490PubMedCrossRef
32.
Zurück zum Zitat Moreland JD (2004) Macular pigment assessment by motion photometry. Arch Biochem Biophys 430:143–148PubMedCrossRef Moreland JD (2004) Macular pigment assessment by motion photometry. Arch Biochem Biophys 430:143–148PubMedCrossRef
33.
Zurück zum Zitat Stone RA, Quinn GE, Francis EL, Ying GS, Flitcroft DI, Parekh P, Brown J, Orlow J, Schmid G (2004) Diurnal axial length fluctuations in human eyes. Invest Ophthalmol Vis Sci 45:63–70PubMedCrossRef Stone RA, Quinn GE, Francis EL, Ying GS, Flitcroft DI, Parekh P, Brown J, Orlow J, Schmid G (2004) Diurnal axial length fluctuations in human eyes. Invest Ophthalmol Vis Sci 45:63–70PubMedCrossRef
34.
Zurück zum Zitat Tang CY, Yip HS, Poon MY, Yau WL, Yap MK (2004) Macular pigment optical density in young Chinese adults. Ophthalmic Physiol Opt 24:586–593PubMedCrossRef Tang CY, Yip HS, Poon MY, Yau WL, Yap MK (2004) Macular pigment optical density in young Chinese adults. Ophthalmic Physiol Opt 24:586–593PubMedCrossRef
35.
Zurück zum Zitat Lam RF, Rao SK, Fan DS, Lau FT, Lam DS (2005) Macular pigment optical density in a Chinese sample. Curr Eye Res 30:799–805PubMed Lam RF, Rao SK, Fan DS, Lau FT, Lam DS (2005) Macular pigment optical density in a Chinese sample. Curr Eye Res 30:799–805PubMed
36.
Zurück zum Zitat van der Veen RL, Berendschot TT, Hendrikse F, Carden D, Makridaki M, Murray IJ (2009) A new desktop instrument for measuring macular pigment optical density based on a novel technique for setting flicker thresholds. Ophthalmic Physiol Opt 29:127–137PubMedCrossRef van der Veen RL, Berendschot TT, Hendrikse F, Carden D, Makridaki M, Murray IJ (2009) A new desktop instrument for measuring macular pigment optical density based on a novel technique for setting flicker thresholds. Ophthalmic Physiol Opt 29:127–137PubMedCrossRef
37.
Zurück zum Zitat Canovas R, Lima VC, Garcia P, Morini C, Prata TS, Rosen RB (2010) Comparison between macular pigment optical density measurements using two-wavelength autofluorescence and heterochromatic flicker photometry techniques. Invest Ophthalmol Vis Sci 51:3152–3156PubMedCrossRef Canovas R, Lima VC, Garcia P, Morini C, Prata TS, Rosen RB (2010) Comparison between macular pigment optical density measurements using two-wavelength autofluorescence and heterochromatic flicker photometry techniques. Invest Ophthalmol Vis Sci 51:3152–3156PubMedCrossRef
38.
Zurück zum Zitat Raman R, Rajan R, Biswas S, Vaitheeswaran K, Sharma T (2011) Macular pigment optical density in a South Indian population. Invest Ophthalmol Vis Sci 52:7910–7916PubMedCrossRef Raman R, Rajan R, Biswas S, Vaitheeswaran K, Sharma T (2011) Macular pigment optical density in a South Indian population. Invest Ophthalmol Vis Sci 52:7910–7916PubMedCrossRef
39.
Zurück zum Zitat Wolf-Schnurrbusch UE, Roosli N, Weyermann E, Heldner MR, Hohne K, Wolf S (2007) Ethnic differences in macular pigment density and distribution. Invest Ophthalmol Vis Sci 48:3783–3787PubMedCrossRef Wolf-Schnurrbusch UE, Roosli N, Weyermann E, Heldner MR, Hohne K, Wolf S (2007) Ethnic differences in macular pigment density and distribution. Invest Ophthalmol Vis Sci 48:3783–3787PubMedCrossRef
40.
Zurück zum Zitat Nolan JM, Kenny R, O’Regan C, Cronin H, Loughman J, Connolly EE, Kearney P, Loane E, Beatty S (2010) Macular pigment optical density in an ageing Irish population: The Irish Longitudinal Study on Ageing. Ophthalmic Res 44:131–139PubMedCrossRef Nolan JM, Kenny R, O’Regan C, Cronin H, Loughman J, Connolly EE, Kearney P, Loane E, Beatty S (2010) Macular pigment optical density in an ageing Irish population: The Irish Longitudinal Study on Ageing. Ophthalmic Res 44:131–139PubMedCrossRef
41.
Zurück zum Zitat Kirby ML, Beatty S, Loane E, Akkali MC, Connolly EE, Stack J, Nolan JM (2010) A central dip in the macular pigment spatial profile is associated with age and smoking. Invest Ophthalmol Vis Sci 51:6722–6728PubMedCrossRef Kirby ML, Beatty S, Loane E, Akkali MC, Connolly EE, Stack J, Nolan JM (2010) A central dip in the macular pigment spatial profile is associated with age and smoking. Invest Ophthalmol Vis Sci 51:6722–6728PubMedCrossRef
42.
Zurück zum Zitat Ciulla TA, Curran-Celantano J, Cooper DA, Hammond BR Jr, Danis RP, Pratt LM, Riccardi KA, Filloon TG (2001) Macular pigment optical density in a midwestern sample. Ophthalmology 108:730–737PubMedCrossRef Ciulla TA, Curran-Celantano J, Cooper DA, Hammond BR Jr, Danis RP, Pratt LM, Riccardi KA, Filloon TG (2001) Macular pigment optical density in a midwestern sample. Ophthalmology 108:730–737PubMedCrossRef
43.
Zurück zum Zitat Ciulla TA, Hammond BR Jr (2004) Macular pigment density and aging, assessed in the normal elderly and those with cataracts and age-related macular degeneration. Am J Ophthalmol 138:582–587PubMedCrossRef Ciulla TA, Hammond BR Jr (2004) Macular pigment density and aging, assessed in the normal elderly and those with cataracts and age-related macular degeneration. Am J Ophthalmol 138:582–587PubMedCrossRef
44.
Zurück zum Zitat Sasamoto Y, Gomi F, Sawa M, Tsujikawa M, Nishida K (2011) Effect of 1-year lutein supplementation on macular pigment optical density and visual function. Graefes Arch Clin Exp Ophthalmol 249:1847–54PubMedCrossRef Sasamoto Y, Gomi F, Sawa M, Tsujikawa M, Nishida K (2011) Effect of 1-year lutein supplementation on macular pigment optical density and visual function. Graefes Arch Clin Exp Ophthalmol 249:1847–54PubMedCrossRef
45.
Zurück zum Zitat Hammond BR Jr, Ciulla TA, Snodderly DM (2002) Macular pigment density is reduced in obese subjects. Invest Ophthalmol Vis Sci 43:47–50PubMed Hammond BR Jr, Ciulla TA, Snodderly DM (2002) Macular pigment density is reduced in obese subjects. Invest Ophthalmol Vis Sci 43:47–50PubMed
46.
Zurück zum Zitat Sasamoto Y, Gomi F, Sawa M, Tsujikawa M, Hamasaki T (2010) Macular pigment optical density in central serous chorioretinopathy. Invest Ophthalmol Vis Sci 51:5219–5225PubMedCrossRef Sasamoto Y, Gomi F, Sawa M, Tsujikawa M, Hamasaki T (2010) Macular pigment optical density in central serous chorioretinopathy. Invest Ophthalmol Vis Sci 51:5219–5225PubMedCrossRef
47.
Zurück zum Zitat Tsika C, Tsilimbaris MK, Makridaki M, Kontadakis G, Plainis S, Moschandreas J (2011) Assessment of macular pigment optical density (MPOD) in patients with unilateral wet age-related macular degeneration (AMD). Acta Ophthalmol 89:e573–e578PubMedCrossRef Tsika C, Tsilimbaris MK, Makridaki M, Kontadakis G, Plainis S, Moschandreas J (2011) Assessment of macular pigment optical density (MPOD) in patients with unilateral wet age-related macular degeneration (AMD). Acta Ophthalmol 89:e573–e578PubMedCrossRef
48.
Zurück zum Zitat LaRowe TL, Mares JA, Snodderly DM, Klein ML, Wooten BR, Chappell R (2008) Macular pigment density and age-related maculopathy in the Carotenoids in Age-Related Eye Disease Study. An ancillary study of the women's health initiative. Ophthalmology 115(876–883):e871 LaRowe TL, Mares JA, Snodderly DM, Klein ML, Wooten BR, Chappell R (2008) Macular pigment density and age-related maculopathy in the Carotenoids in Age-Related Eye Disease Study. An ancillary study of the women's health initiative. Ophthalmology 115(876–883):e871
49.
Zurück zum Zitat Stringham JM, Hammond BR, Nolan JM, Wooten BR, Mammen A, Smollon W, Snodderly DM (2008) The utility of using customized heterochromatic flicker photometry (cHFP) to measure macular pigment in patients with age-related macular degeneration. Exp Eye Res 87:445–453PubMedCrossRef Stringham JM, Hammond BR, Nolan JM, Wooten BR, Mammen A, Smollon W, Snodderly DM (2008) The utility of using customized heterochromatic flicker photometry (cHFP) to measure macular pigment in patients with age-related macular degeneration. Exp Eye Res 87:445–453PubMedCrossRef
Metadaten
Titel
Inverse relationship between macular pigment optical density and axial length in Chinese subjects with myopia
verfasst von
Nianting Tong
Wei Zhang
Zhenzhen Zhang
Yuanyuan Gong
Billy Wooten
Xingwei Wu
Publikationsdatum
01.06.2013
Verlag
Springer-Verlag
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 6/2013
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-012-2225-z

Weitere Artikel der Ausgabe 6/2013

Graefe's Archive for Clinical and Experimental Ophthalmology 6/2013 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Metastase in der periokulären Region

Metastasen Leitthema

Orbitale und periokuläre metastatische Tumoren galten früher als sehr selten. Aber mit der ständigen Aktualisierung von Medikamenten und Nachweismethoden für die Krebsbehandlung werden neue Chemotherapien und Strahlenbehandlungen eingesetzt. Die …

Staging und Systemtherapie bei okulären und periokulären Metastasen

Metastasen Leitthema

Metastasen bösartiger Erkrankungen sind die häufigsten Tumoren, die im Auge diagnostiziert werden. Sie treten bei ungefähr 5–10 % der Patienten mit soliden Tumoren im Verlauf der Erkrankung auf. Besonders häufig sind diese beim Mammakarzinom und …

Wundheilung nach Trabekulektomie

Trabekulektomie CME-Artikel

Die überschießende Wundheilung in der filtrierenden Glaukomchirurgie ist ein zentraler Faktor für ein operatives Versagen. Nach der Einführung der Trabekulektomie in den 1960er-Jahren wurden viele Faktoren erkannt, die mit einer vermehrten …

„standard operating procedures“ (SOP) – Vorschlag zum therapeutischen Management bei periokulären sowie intraokulären Metastasen

Metastasen Leitthema

Peri- sowie intraokuläre Metastasen sind insgesamt gesehen selten und meist Zeichen einer fortgeschrittenen primären Tumorerkrankung. Die Therapie ist daher zumeist palliativ und selten kurativ. Zudem ist die Therapiefindung sehr individuell. Die …

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.