Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 7/2016

19.02.2016 | Trauma

Long-term results after artificial iris implantation in patients with aniridia

verfasst von: Annekatrin Rickmann, Peter Szurman, Kai Januschowski, Maria Waizel, Martin S. Spitzer, Karl T. Boden, Gesine B. Szurman

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 7/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

The custom-made, flexible artificial iris developed by HumanOptics and Koch can reconstruct the anterior segment of patients with aniridia. The aim of this study was to evaluate the long-term clinical outcome and complication spectrum after artificial iris implantation and the role of the embedded fiber mesh in view of specific complications.

Methods

In this retrospective interventional case series, patients received an artificial iris between 2004 and 2013. Only eyes with a minimum follow-up period of 2 years were included. Indications were congenital, traumatic, or iatrogenic aniridia. The artificial iris was used either with or without embedded fiber mesh for partial or full prostheses.

Results

We included 34 patients (mean age 48.8 years; SD ±17.2) with a mean follow-up of 50.0 months (SD ±18.9 months). No repositioning of prostheses was necessary. In cases of keratopathy (17.6 %) visual function increased from baseline mean 1.6 logMAR (SD ±0.7) to 1.2 logMAR (SD ±0.7) after artificial iris implantation. The remaining iris tissue darkened during the follow-up in 23.5 % (83.3 % with and 10.7 % without mesh), 8.8 % developed glaucoma (50 % with and 0 % without mesh) and 14.7 % needed consecutive surgery after prostheses implantation (50 % with and 7.1 % without mesh). In three out of seven trauma cases (42.9 %) silicone oil was spilled into the anterior chamber after 2.5 years on average.

Conclusion

The artificial iris prosthesis revealed a good clinical outcome in terms of long-term stability, cosmetic appearance, visual function, and represents a good functional iris diaphragm for compartmentalisation. Complications such as glaucoma, darkening of iris tissue, and need for consecutive anterior segment surgery are clearly associated with implants with integrated fiber mesh, but not to those without. Hence, the use of full iris prostheses without embedded fiber mesh, even in cases with remnant iris, and the use of slightly smaller implants than officially recommended may be beneficial.
Literatur
2.
Zurück zum Zitat Mavrikakis I, Mavrikakis E, Syam PP, Bell J, Casey JH, Casswell AG, Brittain GP, Liu C (2005) Surgical management of iris defects with prosthetic iris devices. Eye 19:205–209CrossRefPubMed Mavrikakis I, Mavrikakis E, Syam PP, Bell J, Casey JH, Casswell AG, Brittain GP, Liu C (2005) Surgical management of iris defects with prosthetic iris devices. Eye 19:205–209CrossRefPubMed
3.
Zurück zum Zitat Srinivasan S, Ting DS, Snyder ME, Prasad S, Koch HR (2014) Prosthetic iris devises. Can J Ophthalmol 49(1):6–17CrossRefPubMed Srinivasan S, Ting DS, Snyder ME, Prasad S, Koch HR (2014) Prosthetic iris devises. Can J Ophthalmol 49(1):6–17CrossRefPubMed
5.
Zurück zum Zitat Koch HR (2008) A new foldable artificial iris Indications, surgical techniques and first results. Clin Exp Ophthalmol 36(s1):A1–A61 Koch HR (2008) A new foldable artificial iris Indications, surgical techniques and first results. Clin Exp Ophthalmol 36(s1):A1–A61
6.
Zurück zum Zitat Jonsson NJ, Sahlmüller MC, Ruokonen PC, Torun N, Rieck P (2011) Complications after cosmetic iris implantation. Ophthalmologe 108:455–458CrossRefPubMed Jonsson NJ, Sahlmüller MC, Ruokonen PC, Torun N, Rieck P (2011) Complications after cosmetic iris implantation. Ophthalmologe 108:455–458CrossRefPubMed
7.
Zurück zum Zitat Forlini C, Forlini M, Cavallini GM (2013) Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation. Graefes Arch Clin Exp Ophthalmol 251(10):2493–2494CrossRefPubMed Forlini C, Forlini M, Cavallini GM (2013) Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation. Graefes Arch Clin Exp Ophthalmol 251(10):2493–2494CrossRefPubMed
8.
Zurück zum Zitat Burk SE, Da Mata AP, Snyder ME, Cionni RJ, Cohen JS, Osher RH (2001) Prosthetic iris implantation for congenital, traumatic, or functional iris deficiencies. J Cataract Refract Surg 27:1732–1740CrossRefPubMed Burk SE, Da Mata AP, Snyder ME, Cionni RJ, Cohen JS, Osher RH (2001) Prosthetic iris implantation for congenital, traumatic, or functional iris deficiencies. J Cataract Refract Surg 27:1732–1740CrossRefPubMed
9.
Zurück zum Zitat Thomas BC, Rabsilber TM, Auffarth GU (2013) Aniridia-IOL and artificial iris reconstruction. Klin Monatsbl Augenheilkd 230(8):786–790CrossRefPubMed Thomas BC, Rabsilber TM, Auffarth GU (2013) Aniridia-IOL and artificial iris reconstruction. Klin Monatsbl Augenheilkd 230(8):786–790CrossRefPubMed
11.
Zurück zum Zitat Smiddy WE, Sawusch MR, O’Brian TP, Scott DR, Huang SS (1990) Implantation of scleral-fixated posterior chamber intraocular lenses. J Cataract Refract Surg 16:691–696CrossRefPubMed Smiddy WE, Sawusch MR, O’Brian TP, Scott DR, Huang SS (1990) Implantation of scleral-fixated posterior chamber intraocular lenses. J Cataract Refract Surg 16:691–696CrossRefPubMed
12.
Zurück zum Zitat Engels T (1998) Irisnähte in der geschlossenen Vorderkammer. Ophthalmol Chirurgie 10:21–28 Engels T (1998) Irisnähte in der geschlossenen Vorderkammer. Ophthalmol Chirurgie 10:21–28
13.
Zurück zum Zitat Szurman P, Petermeier K, Aisenbrey S, Spitzer MS, Jaissle G (2010) Z-suture - a new knotless technique for transscleral suture fixation of intraocular implants. Br J Ophthalmol 94:167–169CrossRefPubMed Szurman P, Petermeier K, Aisenbrey S, Spitzer MS, Jaissle G (2010) Z-suture - a new knotless technique for transscleral suture fixation of intraocular implants. Br J Ophthalmol 94:167–169CrossRefPubMed
14.
Zurück zum Zitat Szurman P, Petermeier K, Grisanti S, Jaissle GB, Bartz-Schmidt KU (2007) A new small-incision technique for injector implantation of transsclerally sutured foldable lenses. Ophthalmic Surg Lasers Imaging 38:76–80PubMed Szurman P, Petermeier K, Grisanti S, Jaissle GB, Bartz-Schmidt KU (2007) A new small-incision technique for injector implantation of transsclerally sutured foldable lenses. Ophthalmic Surg Lasers Imaging 38:76–80PubMed
15.
Zurück zum Zitat Koch KR, Heindl LM, Cursiefen C, Koch HR (2014) Artificial iris devices: benefits, limitations, and management of complications. J Cataract Refract Surg 40(3):376–382CrossRefPubMed Koch KR, Heindl LM, Cursiefen C, Koch HR (2014) Artificial iris devices: benefits, limitations, and management of complications. J Cataract Refract Surg 40(3):376–382CrossRefPubMed
16.
Zurück zum Zitat Mayer CS, Hoffmann AE (2015) Surgical treatment with an artificial iris. Ophthalmologe 112(10):865–868CrossRefPubMed Mayer CS, Hoffmann AE (2015) Surgical treatment with an artificial iris. Ophthalmologe 112(10):865–868CrossRefPubMed
17.
Zurück zum Zitat Spitzer MS, Nessmann A, Wagner J, Yoeruek E, Bartz-Schmitz KU, Szurman P, Szurman G (2016) Customized humanoptics silicone iris prosthesis in eyes with posttraumatic iris loss: outcomes and complications. Acta Ophthalmol (Copenh). doi:10.1111/aos12946 Spitzer MS, Nessmann A, Wagner J, Yoeruek E, Bartz-Schmitz KU, Szurman P, Szurman G (2016) Customized humanoptics silicone iris prosthesis in eyes with posttraumatic iris loss: outcomes and complications. Acta Ophthalmol (Copenh). doi:10.​1111/​aos12946
18.
Zurück zum Zitat Hermann MM, Muether PS, Kuhn L, Kirchhof B, Fauser S (2012) Clinical outcome of the artificial iris diaphragm in silicone oil surgery. Br J Ophthalmol 96(7):1008–1011CrossRefPubMed Hermann MM, Muether PS, Kuhn L, Kirchhof B, Fauser S (2012) Clinical outcome of the artificial iris diaphragm in silicone oil surgery. Br J Ophthalmol 96(7):1008–1011CrossRefPubMed
Metadaten
Titel
Long-term results after artificial iris implantation in patients with aniridia
verfasst von
Annekatrin Rickmann
Peter Szurman
Kai Januschowski
Maria Waizel
Martin S. Spitzer
Karl T. Boden
Gesine B. Szurman
Publikationsdatum
19.02.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 7/2016
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-016-3292-3

Weitere Artikel der Ausgabe 7/2016

Graefe's Archive for Clinical and Experimental Ophthalmology 7/2016 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.