Abstract

Background

The use of mesh for laparoscopic repair of large hiatal hernias may reduce recurrence rates in comparison with primary suture repair. However, there is a potential risk of mesh-related oesophageal complications due to prosthesis erosion. The aim of this study was to evaluate a lightweight polypropylene mesh (TiMesh) repair of hiatal hernias with particular reference to intraluminal erosion.

Methods

Data were collected prospectively on 18 consecutive patients undergoing elective laparoscopic repair of a large hiatal hernia with the use of TiMesh between November 2004 and December 2005. Quality of life and symptom analysis was performed using QOLRAD questionnaires preoperatively and postoperatively after 6 weeks, 6 months, 1 year and 2 years. Barium studies were performed preoperatively and 2 years postoperatively to assess hernia recurrence. After 2 years, oesophagogastric endoscopy was performed to assess signs of mesh-related complications.

Results

All operations were completed laparoscopically. There was no 30-day mortality and median hospital stay was 2.8 days (range 2–13 days). Complications occurred in two patients (11%), both of whom were treated without residual disability. Two years after hiatal hernia repair, there was significant improvement in quality-of-life scores (QOLRAD 5.79, p < 0.001). There was no difference between pre- and postoperative dysphagia scores. No signs of stricture formation or prosthetic erosion were identified during endoscopic follow-up. One patient had a small (2 cm) sliding hiatal hernia demonstrated by barium studies, which was asymptomatic.

Conclusions

Laparoscopic reinforcement of primary hiatal closure with TiMesh leads to a durable repair in patients with large hiatal hernias. Endoscopic follow-up did not show any signs of mesh-related complications after prosthetic reinforcement of the crural repair. Our preliminary results suggest that it is safe to proceed with this lightweight polypropylene mesh for reinforcement of the hiatal repair.
Literatur
1.
Zurück zum Zitat Aly A, Munt J, Jamieson GG, Ludemann R, Devitt PG, Watson DI (2005) Laparoscopic repair of large hiatal hernias. Br J Surg 92(5):648–653PubMedCrossRef Aly A, Munt J, Jamieson GG, Ludemann R, Devitt PG, Watson DI (2005) Laparoscopic repair of large hiatal hernias. Br J Surg 92(5):648–653PubMedCrossRef
2.
Zurück zum Zitat Smith G, Isaacson J, Draganic B, Baladas H, Falk G (2004) Symptomatic and radiological follow up after para-oesophageal hernia repair. Dis Esophagus 17(4):279–284PubMedCrossRef Smith G, Isaacson J, Draganic B, Baladas H, Falk G (2004) Symptomatic and radiological follow up after para-oesophageal hernia repair. Dis Esophagus 17(4):279–284PubMedCrossRef
3.
Zurück zum Zitat Basso N, Rosato P, De Leo A, Genco A, Rea S, Neri T (1999) “Tension-free” hiatoplasty, gastrophrenic anchorage, and 360 degrees fundoplication in the laparoscopic treatment of paraesophageal hernia. Surg Laparosc Endosc Percutan Tech 9(4):257–262PubMedCrossRef Basso N, Rosato P, De Leo A, Genco A, Rea S, Neri T (1999) “Tension-free” hiatoplasty, gastrophrenic anchorage, and 360 degrees fundoplication in the laparoscopic treatment of paraesophageal hernia. Surg Laparosc Endosc Percutan Tech 9(4):257–262PubMedCrossRef
4.
Zurück zum Zitat Behrns KE, Schlinkert RT (1996) Laparoscopic management of paraesophageal hernia: early results. J Laparoendosc Surg 6(5):311–317PubMed Behrns KE, Schlinkert RT (1996) Laparoscopic management of paraesophageal hernia: early results. J Laparoendosc Surg 6(5):311–317PubMed
5.
Zurück zum Zitat Carlson MA, Condon RE, Ludwig KA, Schulte WJ (1998) Management of intrathoracic stomach with polypropylene mesh prosthesis reinforced transabdominal hiatus hernia repair. J Am Coll Surg 187(3):227–230PubMedCrossRef Carlson MA, Condon RE, Ludwig KA, Schulte WJ (1998) Management of intrathoracic stomach with polypropylene mesh prosthesis reinforced transabdominal hiatus hernia repair. J Am Coll Surg 187(3):227–230PubMedCrossRef
6.
Zurück zum Zitat Frantzides C, Madan A, Carlson M, Stavropoulos G (2002) A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg 137(6):649–652PubMedCrossRef Frantzides C, Madan A, Carlson M, Stavropoulos G (2002) A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg 137(6):649–652PubMedCrossRef
7.
Zurück zum Zitat Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J et al (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244(4):481–490PubMed Oelschlager BK, Pellegrini CA, Hunter J, Soper N, Brunt M, Sheppard B, Jobe B, Polissar N, Mitsumori L, Nelson J et al (2006) Biologic prosthesis reduces recurrence after laparoscopic paraesophageal hernia repair: a multicenter, prospective, randomized trial. Ann Surg 244(4):481–490PubMed
8.
Zurück zum Zitat Klosterhalfen B, Junge K, Klinge U (2005) The lightweight and large porous mesh concept for hernia repair. Expert Rev Med Dev 2(1):103–117CrossRef Klosterhalfen B, Junge K, Klinge U (2005) The lightweight and large porous mesh concept for hernia repair. Expert Rev Med Dev 2(1):103–117CrossRef
9.
Zurück zum Zitat Scheidbach H, Tamme C, Tannapfel A, Lippert H, Kockerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigs. Surg Endosc 18(2):211–220PubMedCrossRef Scheidbach H, Tamme C, Tannapfel A, Lippert H, Kockerling F (2004) In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigs. Surg Endosc 18(2):211–220PubMedCrossRef
10.
Zurück zum Zitat Schug-Pass C, Tamme C, Tannapfel A, Kockerling F (2006) A lightweight polypropylene mesh (TiMesh) for laparoscopic intraperitoneal repair of abdominal wall hernias: comparison of biocompatibility with the DualMesh in an experimental study using the porcine model. Surg Endosc 20(3):402–409PubMedCrossRef Schug-Pass C, Tamme C, Tannapfel A, Kockerling F (2006) A lightweight polypropylene mesh (TiMesh) for laparoscopic intraperitoneal repair of abdominal wall hernias: comparison of biocompatibility with the DualMesh in an experimental study using the porcine model. Surg Endosc 20(3):402–409PubMedCrossRef
11.
Zurück zum Zitat Dakkak M, Bennett JR (1992) A new dysphagia score with objective validation. J Clin Gastroenterol 14(2):99–100PubMedCrossRef Dakkak M, Bennett JR (1992) A new dysphagia score with objective validation. J Clin Gastroenterol 14(2):99–100PubMedCrossRef
12.
Zurück zum Zitat Wiklund I, Junghard O, Grace E, Talley N, Kamm M, Veldhuyzen van Zanten S, Pare P, Chiba N, Leddin D, Bigard M et al (1998) Quality of life in reflux and dyspepsia patients. Psychometric documentation of a new disease-specific questionnaire (QOLRAD). Eur J Surg 164(Suppl 583):41–49 Wiklund I, Junghard O, Grace E, Talley N, Kamm M, Veldhuyzen van Zanten S, Pare P, Chiba N, Leddin D, Bigard M et al (1998) Quality of life in reflux and dyspepsia patients. Psychometric documentation of a new disease-specific questionnaire (QOLRAD). Eur J Surg 164(Suppl 583):41–49
13.
Zurück zum Zitat Casaccia M, Torelli P, Panaro F, Cavaliere D, Saltalamacchia L, Troilo BM, Savelli A, Valente U (2005) Laparoscopic tension-free repair of large paraesophageal hiatal hernias with a composite A-shaped mesh: two-year follow-up. J Laparoendosc Adv Surg Tech A 15(3):279–284PubMedCrossRef Casaccia M, Torelli P, Panaro F, Cavaliere D, Saltalamacchia L, Troilo BM, Savelli A, Valente U (2005) Laparoscopic tension-free repair of large paraesophageal hiatal hernias with a composite A-shaped mesh: two-year follow-up. J Laparoendosc Adv Surg Tech A 15(3):279–284PubMedCrossRef
14.
Zurück zum Zitat Keidar A, Szold A (2003) Laparoscopic repair of paraesophageal hernia with selective use of mesh. Surg Laparosc Endosc Percutan Tech 13(3):149–154PubMedCrossRef Keidar A, Szold A (2003) Laparoscopic repair of paraesophageal hernia with selective use of mesh. Surg Laparosc Endosc Percutan Tech 13(3):149–154PubMedCrossRef
15.
Zurück zum Zitat Targarona EM, Novell J, Vela S, Cerdan G, Bendahan G, Torrubia S, Kobus C, Rebasa P, Balague C, Garriga J et al (2004) Mid term analysis of safety and quality of life after the laparoscopic repair of paraesophageal hiatal hernia. Surg Endosc 18(7):1045–1050PubMedCrossRef Targarona EM, Novell J, Vela S, Cerdan G, Bendahan G, Torrubia S, Kobus C, Rebasa P, Balague C, Garriga J et al (2004) Mid term analysis of safety and quality of life after the laparoscopic repair of paraesophageal hiatal hernia. Surg Endosc 18(7):1045–1050PubMedCrossRef
16.
Zurück zum Zitat Johnson JM, Carbonell AM, Carmody BJ, Jamal MK, Maher JW, Kellum JM, DeMaria EJ (2006) Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplications: a critical analysis of the available literature. Surg Endosc 20(3):362–366PubMedCrossRef Johnson JM, Carbonell AM, Carmody BJ, Jamal MK, Maher JW, Kellum JM, DeMaria EJ (2006) Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplications: a critical analysis of the available literature. Surg Endosc 20(3):362–366PubMedCrossRef
17.
Zurück zum Zitat Coluccio G, Ponzio S, Ambu V, Tramontano R, Cuomo G (2000) Dislocation into the cardial lumen of a PTFE prosthesis used in the treatment of voluminous hiatal sliding hernia. A case report. Minerva Chir 55(5):341–345PubMed Coluccio G, Ponzio S, Ambu V, Tramontano R, Cuomo G (2000) Dislocation into the cardial lumen of a PTFE prosthesis used in the treatment of voluminous hiatal sliding hernia. A case report. Minerva Chir 55(5):341–345PubMed
18.
Zurück zum Zitat Dutta S (2007) Prosthetic esophageal erosion after mesh hiatoplasty in a child, removed by transabdominal endogastric surgery. J Pediatr Surg 42(1):252–256PubMedCrossRef Dutta S (2007) Prosthetic esophageal erosion after mesh hiatoplasty in a child, removed by transabdominal endogastric surgery. J Pediatr Surg 42(1):252–256PubMedCrossRef
19.
Zurück zum Zitat Tatum RP, Shalhub S, Oelschlager BK, Pellegrini CA (2007) Complications of PTFE Mesh at the Diaphragmatic Hiatus. J Gastrointest Surg. 2008 12(5):953–957. Epub 2007 Sep 18 Tatum RP, Shalhub S, Oelschlager BK, Pellegrini CA (2007) Complications of PTFE Mesh at the Diaphragmatic Hiatus. J Gastrointest Surg. 2008 12(5):953–957. Epub 2007 Sep 18
20.
Zurück zum Zitat Granderath F, Carlson M, Champion JK, Szold A, Basso N, Pointner R, Frantzides C (2006) Prosthetic closure of the esophageal hiatus in large hiatal hernia repair and laparoscopic antireflux surgery. Surg Endosc 20(3):367–379PubMedCrossRef Granderath F, Carlson M, Champion JK, Szold A, Basso N, Pointner R, Frantzides C (2006) Prosthetic closure of the esophageal hiatus in large hiatal hernia repair and laparoscopic antireflux surgery. Surg Endosc 20(3):367–379PubMedCrossRef
21.
Zurück zum Zitat Hazebroek EJ, Koak Y, Berry H, Leibman S, Smith GS (2008) Critical evaluation of a novel DualMesh repair for large hiatal hernias. Surg Endosc. Mar 5 [Epub ahead of print] Hazebroek EJ, Koak Y, Berry H, Leibman S, Smith GS (2008) Critical evaluation of a novel DualMesh repair for large hiatal hernias. Surg Endosc. Mar 5 [Epub ahead of print]
22.
Zurück zum Zitat Eriksen JR, Gogenur I, Rosenberg J (2007) Choice of mesh for laparoscopic ventral hernia repair. Hernia 11(6):481–492PubMedCrossRef Eriksen JR, Gogenur I, Rosenberg J (2007) Choice of mesh for laparoscopic ventral hernia repair. Hernia 11(6):481–492PubMedCrossRef
23.
Zurück zum Zitat Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103(2):208–214PubMedCrossRef Klinge U, Klosterhalfen B, Birkenhauer V, Junge K, Conze J, Schumpelick V (2002) Impact of polymer pore size on the interface scar formation in a rat model. J Surg Res 103(2):208–214PubMedCrossRef
24.
Zurück zum Zitat Conze J, Rosch R, Klinge U, Weiss C, Anurov M, Titkowa S, Oettinger A, Schumpelick V (2004) Polypropylene in the intra-abdominal position: influence of pore size and surface area. Hernia 8(4):365–372PubMedCrossRef Conze J, Rosch R, Klinge U, Weiss C, Anurov M, Titkowa S, Oettinger A, Schumpelick V (2004) Polypropylene in the intra-abdominal position: influence of pore size and surface area. Hernia 8(4):365–372PubMedCrossRef
25.
Zurück zum Zitat Shulman AG, Amid PK, Lichtenstein IL (1992) The safety of mesh repair for primary inguinal hernias: results of 3, 019 operations from five diverse surgical sources. Am Surg 58(4):255–257PubMed Shulman AG, Amid PK, Lichtenstein IL (1992) The safety of mesh repair for primary inguinal hernias: results of 3, 019 operations from five diverse surgical sources. Am Surg 58(4):255–257PubMed
26.
Zurück zum Zitat Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, IJzermans JN, Boelhouwer RU, de Vries BC, Salu MK, Wereldsma JC et al (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 343(6):392–398PubMedCrossRef Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, IJzermans JN, Boelhouwer RU, de Vries BC, Salu MK, Wereldsma JC et al (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 343(6):392–398PubMedCrossRef
Metadaten
Titel
Evaluation of lightweight titanium-coated polypropylene mesh (TiMesh) for laparoscopic repair of large hiatal hernias
verfasst von
Eric J. Hazebroek
Ada Ng
David H. K. Yong
Hayley Berry
Steven Leibman
Garett S. Smith
Publikationsdatum
01.11.2008
Verlag
Springer-Verlag
Erschienen in
Surgical Endoscopy / Ausgabe 11/2008
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-008-0070-2

Weitere Artikel der Ausgabe 11/2008

Surgical Endoscopy 11/2008 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.