Skip to main content
Erschienen in: Hernia 6/2018

25.08.2018 | Original Article

Use of polypropylene mesh in contaminated and dirty strangulated hernias: short-term results

verfasst von: H. Pandey, D. S. Thakur, U. Somashekar, R. Kothari, P. Agarwal, D. Sharma

Erschienen in: Hernia | Ausgabe 6/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Synthetic non-absorbable meshes are routinely used in hernia surgery for clean cases but are avoided in the case of clean-contaminated or contaminated hernia or dirty cases to minimize the risk of infection. The present study was conducted to evaluate the outcome of polypropylene mesh in the settings of bowel resection performed for strangulated hernias of the abdominal wall.

Methods

This prospective observational study was conducted in the Department of Surgery of a teaching hospital in central India between 1st March 2015 and 31st Aug 2017. Adult patients > 18 years age, with abdominal wall hernias, presenting with strangulation, and requiring resection and anastomosis for gangrenous bowel were included in the study. Outcomes noted were wound infection, morbidity and mortality, need for the removal of the mesh, and recurrence of the hernia.

Results

30 (22 men and 8 women) patients with strangulated hernias underwent emergency surgery with resection of gangrenous bowel and anastomosis. The 30 cases included 21 inguinal, seven incisional, one femoral and one umbilical hernia. 12 of the 30 cases having gross contamination of the operative wound due to perforated gangrenous bowel were classified as ‘dirty’; while the remaining 18 cases with non-perforated gangrenous herniating bowel were classified as ‘contaminated’. Wound infection occurred in 8/30 patients (26.67%); but these healed with antibiotics and dressing. Mesh removal was not required in any patient during entire study period. Two recurrences (6.7%; one inguinal and one incisional hernia) were observed. There was no mortality.

Conclusion

The use of polypropylene mesh for contaminated and dirty strangulated hernias is effective and safe, with acceptable morbidity and good short-term results.
Literatur
1.
Zurück zum Zitat Sanders DL, Kingsnorth AN (2012) Prosthetic mesh materials used in hernia surgery. Expert Rev Med Devices 9(2):159–179PubMedCrossRef Sanders DL, Kingsnorth AN (2012) Prosthetic mesh materials used in hernia surgery. Expert Rev Med Devices 9(2):159–179PubMedCrossRef
2.
Zurück zum Zitat Mazaki T, Mado K, Masuda H et al (2014) A randomized trial of antibiotic prophylaxis for the prevention of surgical site infection after open mesh-plug hernia repair. Am J Surg 207(4):476–484PubMedCrossRef Mazaki T, Mado K, Masuda H et al (2014) A randomized trial of antibiotic prophylaxis for the prevention of surgical site infection after open mesh-plug hernia repair. Am J Surg 207(4):476–484PubMedCrossRef
3.
Zurück zum Zitat Platt R, Zalenznik DF, Hopkins CC et al (1990) Perioperative antibiotic prophylaxis for herniorrhaphy and breast surgery. N Engl J Med 322(3):153–160PubMedCrossRef Platt R, Zalenznik DF, Hopkins CC et al (1990) Perioperative antibiotic prophylaxis for herniorrhaphy and breast surgery. N Engl J Med 322(3):153–160PubMedCrossRef
4.
Zurück zum Zitat Stephenson BM (2003) Complications of open groin hernia repair. Surg Clin North Am 83(5):1255–1278PubMedCrossRef Stephenson BM (2003) Complications of open groin hernia repair. Surg Clin North Am 83(5):1255–1278PubMedCrossRef
5.
Zurück zum Zitat Lazorthes F, Chiotasso P, Massip P et al (1992) Local antibiotic prophylaxis in inguinal hernia repair. Surg Gynecol Obstet 175(6):569–570PubMed Lazorthes F, Chiotasso P, Massip P et al (1992) Local antibiotic prophylaxis in inguinal hernia repair. Surg Gynecol Obstet 175(6):569–570PubMed
7.
Zurück zum Zitat Alvarez JA, Baldonedo RF, Bear IG, Solis JA, Alvarez P, Jorge JI (2004) Incarcerated groin hernias in adults: presentation and outcome. Hernia 8(2):121–126PubMedCrossRef Alvarez JA, Baldonedo RF, Bear IG, Solis JA, Alvarez P, Jorge JI (2004) Incarcerated groin hernias in adults: presentation and outcome. Hernia 8(2):121–126PubMedCrossRef
8.
Zurück zum Zitat Nieuwenhuizen J, van Ramshorst GH, ten Brinke JG et al (2011) The use of mesh in acute hernia: frequency and outcome in 99 cases. Hernia 15(3):297–300PubMedPubMedCentralCrossRef Nieuwenhuizen J, van Ramshorst GH, ten Brinke JG et al (2011) The use of mesh in acute hernia: frequency and outcome in 99 cases. Hernia 15(3):297–300PubMedPubMedCentralCrossRef
9.
Zurück zum Zitat Zafar H, Zaidi M, Qadir I, Memon AA (2012) Emergency incisional hernia repair: a difficult problem waiting for a solution. Ann Surg Innov Res 6(1):1PubMedPubMedCentralCrossRef Zafar H, Zaidi M, Qadir I, Memon AA (2012) Emergency incisional hernia repair: a difficult problem waiting for a solution. Ann Surg Innov Res 6(1):1PubMedPubMedCentralCrossRef
10.
Zurück zum Zitat Bessa SS, Abdel-Razek AH (2013) Results of prosthetic mesh repair in the emergency management of the acutely incarcerated and/or strangulated ventral hernias: a 7 years study. Hernia 17(1):59–65PubMedCrossRef Bessa SS, Abdel-Razek AH (2013) Results of prosthetic mesh repair in the emergency management of the acutely incarcerated and/or strangulated ventral hernias: a 7 years study. Hernia 17(1):59–65PubMedCrossRef
11.
Zurück zum Zitat Olsen MA, Nickel KB, Wallace AE, Mines D, Fraser VJ, Warren DK (2015) Stratification of surgical site infection by operative factors and comparison of infection rates after hernia repair. Infect Control Hosp Epidemiol 36(3):329–335PubMedPubMedCentralCrossRef Olsen MA, Nickel KB, Wallace AE, Mines D, Fraser VJ, Warren DK (2015) Stratification of surgical site infection by operative factors and comparison of infection rates after hernia repair. Infect Control Hosp Epidemiol 36(3):329–335PubMedPubMedCentralCrossRef
12.
Zurück zum Zitat Choi JJ, Palaniappa NC, Dallas KB, Rudich TB, Colon MJ, Divino CM (2012) Use of mesh during ventral hernia repair in clean-contaminated and contaminated cases: outcomes of 33,832 cases. Ann Surg 255(1):176–180PubMedCrossRef Choi JJ, Palaniappa NC, Dallas KB, Rudich TB, Colon MJ, Divino CM (2012) Use of mesh during ventral hernia repair in clean-contaminated and contaminated cases: outcomes of 33,832 cases. Ann Surg 255(1):176–180PubMedCrossRef
13.
Zurück zum Zitat Sartelli M, Coccolini F, Ramshorst G et al (2013) WSES guidelines for emergency repair of complicated abdominal wall hernias. World J Emerg Surg 8(1):50PubMedPubMedCentralCrossRef Sartelli M, Coccolini F, Ramshorst G et al (2013) WSES guidelines for emergency repair of complicated abdominal wall hernias. World J Emerg Surg 8(1):50PubMedPubMedCentralCrossRef
14.
Zurück zum Zitat Yang L, Wang H, Liang X et al (2015) Bacteria in hernia sac: an important risk fact for surgical site infection after incarcerated hernia repair. Hernia 19(2):279–283PubMedCrossRef Yang L, Wang H, Liang X et al (2015) Bacteria in hernia sac: an important risk fact for surgical site infection after incarcerated hernia repair. Hernia 19(2):279–283PubMedCrossRef
16.
Zurück zum Zitat Ferzoco SJ (2013) A systematic review of outcomes following repair of complex ventral incisional hernias with biologic mesh. Int Surg 98(4):399–408PubMedPubMedCentralCrossRef Ferzoco SJ (2013) A systematic review of outcomes following repair of complex ventral incisional hernias with biologic mesh. Int Surg 98(4):399–408PubMedPubMedCentralCrossRef
17.
Zurück zum Zitat Rosen MJ, Bauer JJ, Harmaty M et al (2017) Multicenter, prospective, longitudinal study of the recurrence, surgical site infection, and quality of life after contaminated ventral hernia repair using biosynthetic absorbable mesh: the COBRA study. Ann Surg 265(1):205–211PubMedCrossRef Rosen MJ, Bauer JJ, Harmaty M et al (2017) Multicenter, prospective, longitudinal study of the recurrence, surgical site infection, and quality of life after contaminated ventral hernia repair using biosynthetic absorbable mesh: the COBRA study. Ann Surg 265(1):205–211PubMedCrossRef
18.
Zurück zum Zitat Novitsky YW (2013) Biology of biological meshes used in hernia repair. Surg Clin North Am 93(5):1211–1215PubMedCrossRef Novitsky YW (2013) Biology of biological meshes used in hernia repair. Surg Clin North Am 93(5):1211–1215PubMedCrossRef
19.
Zurück zum Zitat Cross W, Kumar A, Chandru Kowdley G (2014) Biological mesh in contaminated fields—overuse without data: a systematic review of their use in abdominal wall reconstruction. Am Surg 80(1):3–8PubMed Cross W, Kumar A, Chandru Kowdley G (2014) Biological mesh in contaminated fields—overuse without data: a systematic review of their use in abdominal wall reconstruction. Am Surg 80(1):3–8PubMed
20.
Zurück zum Zitat López-Cano M, Quiles MT, Pereira JA, Armengol-Carrasco M, Arbós Vía MA (2017) Complex abdominal wall hernia repair in contaminated surgical fields: factors affecting the choice of prosthesis. Am Surg 83(6):583–590PubMed López-Cano M, Quiles MT, Pereira JA, Armengol-Carrasco M, Arbós Vía MA (2017) Complex abdominal wall hernia repair in contaminated surgical fields: factors affecting the choice of prosthesis. Am Surg 83(6):583–590PubMed
21.
Zurück zum Zitat Mariette C, Wind P, Micelli Lupinacci R et al (2014) Practice patterns in complex ventral hernia repair and place of biological grafts: a national survey among French digestive academic surgeons. J Visc Surg 151(1):9–16PubMedCrossRef Mariette C, Wind P, Micelli Lupinacci R et al (2014) Practice patterns in complex ventral hernia repair and place of biological grafts: a national survey among French digestive academic surgeons. J Visc Surg 151(1):9–16PubMedCrossRef
22.
Zurück zum Zitat Birindelli A, Sartelli M, Di Saverio S et al (2017) 2017 update of the WSES guidelines for emergency repair of complicated abdominal wall hernias. World J Emerg Surg 12:37PubMedPubMedCentralCrossRef Birindelli A, Sartelli M, Di Saverio S et al (2017) 2017 update of the WSES guidelines for emergency repair of complicated abdominal wall hernias. World J Emerg Surg 12:37PubMedPubMedCentralCrossRef
23.
Zurück zum Zitat Pans A, Desaive C, Jacquet N (1997) Use of a preperitoneal prosthesis for strangulated groin hernia. Br J Surg 84(3):310–312PubMedCrossRef Pans A, Desaive C, Jacquet N (1997) Use of a preperitoneal prosthesis for strangulated groin hernia. Br J Surg 84(3):310–312PubMedCrossRef
24.
Zurück zum Zitat Wysocki A, Pozniczek M, Krzywon J, Bolt L (2001) Use of polypropylene prostheses for strangulated inguinal and incisional hernias. Hernia 5(2):105–106PubMedCrossRef Wysocki A, Pozniczek M, Krzywon J, Bolt L (2001) Use of polypropylene prostheses for strangulated inguinal and incisional hernias. Hernia 5(2):105–106PubMedCrossRef
25.
Zurück zum Zitat D’Ambrosio R, Capasso L, Sgueglia S et al (2004) The meshes of polypropylene in emergency surgery for strangulated hernias and incisional hernias. Ann Ital Chir 75(5):569–573 (article in Italian) PubMed D’Ambrosio R, Capasso L, Sgueglia S et al (2004) The meshes of polypropylene in emergency surgery for strangulated hernias and incisional hernias. Ann Ital Chir 75(5):569–573 (article in Italian) PubMed
26.
Zurück zum Zitat Topcu O, Kurt A, Soylu S, Akgol G, Atabey M, Karakus BC, Aydin C (2013) Polypropylene mesh repair of incarcerated and strangulated hernias: a prospective clinical study. Surg Today 43(10):1140–1144PubMedCrossRef Topcu O, Kurt A, Soylu S, Akgol G, Atabey M, Karakus BC, Aydin C (2013) Polypropylene mesh repair of incarcerated and strangulated hernias: a prospective clinical study. Surg Today 43(10):1140–1144PubMedCrossRef
27.
Zurück zum Zitat Carbonell AM, Cobb WS (2013) Safety of prosthetic mesh hernia repair in contaminated fields. Surg Clin North Am 93(5):1227–1239PubMedCrossRef Carbonell AM, Cobb WS (2013) Safety of prosthetic mesh hernia repair in contaminated fields. Surg Clin North Am 93(5):1227–1239PubMedCrossRef
28.
Zurück zum Zitat Bessa SS, Abdel-fattah MR, Al-Sayes IA, Korayem IT (2015) Results of prosthetic mesh repair in the emergency management of the acutely incarcerated and/or strangulated groin hernia: a 10-year study. Hernia 19(6):909–914PubMedCrossRef Bessa SS, Abdel-fattah MR, Al-Sayes IA, Korayem IT (2015) Results of prosthetic mesh repair in the emergency management of the acutely incarcerated and/or strangulated groin hernia: a 10-year study. Hernia 19(6):909–914PubMedCrossRef
29.
Zurück zum Zitat Slater NJ, Knaapen L, Bökkerink WJ et al (2015) Large contaminated ventral hernia repair using component separation technique with synthetic mesh. Plast Reconstr Surg 136(6):796e–805ePubMedCrossRef Slater NJ, Knaapen L, Bökkerink WJ et al (2015) Large contaminated ventral hernia repair using component separation technique with synthetic mesh. Plast Reconstr Surg 136(6):796e–805ePubMedCrossRef
30.
Zurück zum Zitat Barbuto RC, Duval-Araujo I, Barral SM, Rocha RG, Bechara Cde S, Barbosa AJ (2014) Use of alloplastic meshes in abdominal wounds of rats with induced peritonitis. Arq Bras Cir Dig 27(1):26–29PubMedPubMedCentralCrossRef Barbuto RC, Duval-Araujo I, Barral SM, Rocha RG, Bechara Cde S, Barbosa AJ (2014) Use of alloplastic meshes in abdominal wounds of rats with induced peritonitis. Arq Bras Cir Dig 27(1):26–29PubMedPubMedCentralCrossRef
31.
Zurück zum Zitat Bury K, Smietański M, Justyna B et al (2014) Effects of macroporous monofilament mesh on infection in a contaminated field. Langenbecks Arch Surg 399(7):873–877PubMedPubMedCentralCrossRef Bury K, Smietański M, Justyna B et al (2014) Effects of macroporous monofilament mesh on infection in a contaminated field. Langenbecks Arch Surg 399(7):873–877PubMedPubMedCentralCrossRef
32.
Zurück zum Zitat Klosterhalfen B, Klinge U (2013) Retrieval study at 623 human mesh explants made of polypropylene—impact of mesh class and indication for mesh removal on tissue reaction. J Biomed Mater Res B Appl Biomater 101(8):1393–1399PubMedCrossRef Klosterhalfen B, Klinge U (2013) Retrieval study at 623 human mesh explants made of polypropylene—impact of mesh class and indication for mesh removal on tissue reaction. J Biomed Mater Res B Appl Biomater 101(8):1393–1399PubMedCrossRef
33.
Zurück zum Zitat Sanders DL, Kingsnorth AN, Moate R, Steer JA (2013) An in vitro study assessing the infection risk of low-cost polyethylene mosquito net compared with commercial hernia prosthetics. J Surg Res 183(2):e31–e37PubMedCrossRef Sanders DL, Kingsnorth AN, Moate R, Steer JA (2013) An in vitro study assessing the infection risk of low-cost polyethylene mosquito net compared with commercial hernia prosthetics. J Surg Res 183(2):e31–e37PubMedCrossRef
34.
Zurück zum Zitat Belyansky I, Tsirline VB, Montero PN et al (2011) Lysostaphin-coated mesh prevents staphylococcal infection and significantly improves survival in a contaminated surgical field. Am Surg 77(8):1025–1031PubMed Belyansky I, Tsirline VB, Montero PN et al (2011) Lysostaphin-coated mesh prevents staphylococcal infection and significantly improves survival in a contaminated surgical field. Am Surg 77(8):1025–1031PubMed
35.
Zurück zum Zitat Majumder A, Neupane R, Novitsky YW (2015) Antibiotic coating of hernia meshes: the next step toward preventing mesh infection. Surg Technol Int 27:147–153PubMed Majumder A, Neupane R, Novitsky YW (2015) Antibiotic coating of hernia meshes: the next step toward preventing mesh infection. Surg Technol Int 27:147–153PubMed
36.
Zurück zum Zitat Kahramanca Ş, Kaya O, Azılı C, Celep B, Gökce E, Küçükpınar T (2013) Does topical rifampicin reduce the risk of surgical field infection in hernia repair? Ulus Cerrahi Derg 29(2):54–58PubMedPubMedCentral Kahramanca Ş, Kaya O, Azılı C, Celep B, Gökce E, Küçükpınar T (2013) Does topical rifampicin reduce the risk of surgical field infection in hernia repair? Ulus Cerrahi Derg 29(2):54–58PubMedPubMedCentral
37.
Zurück zum Zitat Nobaek S. Rogmark P. Petersson U (2017) Negative pressure wound therapy for treatment of mesh infection after abdominal surgery: long-term results and patient-reported outcome. Scand J Surg 106(4):285–293PubMedCrossRef Nobaek S. Rogmark P. Petersson U (2017) Negative pressure wound therapy for treatment of mesh infection after abdominal surgery: long-term results and patient-reported outcome. Scand J Surg 106(4):285–293PubMedCrossRef
38.
Zurück zum Zitat Venturi ML. Attinger CE. Mesbahi AN. Hess CL, Graw KS (2005) Mechanisms and clinical applications of the vacuum-assisted closure (VAC) device: a review. Am J Clin Dermatol 6(3):185–194PubMedCrossRef Venturi ML. Attinger CE. Mesbahi AN. Hess CL, Graw KS (2005) Mechanisms and clinical applications of the vacuum-assisted closure (VAC) device: a review. Am J Clin Dermatol 6(3):185–194PubMedCrossRef
39.
Zurück zum Zitat Bonds AM. Novick TK. Dietert JN. Araghizadeh FY. Olson CH (2013) Incisional negative pressure wound therapy significantly reduces surgical site infection in open colorectal surgery. Dis Colon Rectum 56(6):1403–1408PubMedCrossRef Bonds AM. Novick TK. Dietert JN. Araghizadeh FY. Olson CH (2013) Incisional negative pressure wound therapy significantly reduces surgical site infection in open colorectal surgery. Dis Colon Rectum 56(6):1403–1408PubMedCrossRef
40.
Zurück zum Zitat Olona C. Duque E. Caro A et al (2014) Negative-pressure therapy in the postoperative treatment of incisional hernioplasty wounds: a pilot study. Adv Skin Wound Care 27(2):77–80PubMedCrossRef Olona C. Duque E. Caro A et al (2014) Negative-pressure therapy in the postoperative treatment of incisional hernioplasty wounds: a pilot study. Adv Skin Wound Care 27(2):77–80PubMedCrossRef
41.
Zurück zum Zitat Albino FP, Patel KM, Nahabedian MY, Sosin M, Attinger CE, Bhanot P (2013) Does mesh location matter in abdominal wall reconstruction? A systematic review of the literature and a summary of recommendations. Plast Reconstr Surg 132(5):1295–1304CrossRefPubMed Albino FP, Patel KM, Nahabedian MY, Sosin M, Attinger CE, Bhanot P (2013) Does mesh location matter in abdominal wall reconstruction? A systematic review of the literature and a summary of recommendations. Plast Reconstr Surg 132(5):1295–1304CrossRefPubMed
42.
Zurück zum Zitat Kirby JP, Mazuski JE (2009) Prevention of surgical site infection. Surg Clin North Am 89(2):365–389PubMedCrossRef Kirby JP, Mazuski JE (2009) Prevention of surgical site infection. Surg Clin North Am 89(2):365–389PubMedCrossRef
Metadaten
Titel
Use of polypropylene mesh in contaminated and dirty strangulated hernias: short-term results
verfasst von
H. Pandey
D. S. Thakur
U. Somashekar
R. Kothari
P. Agarwal
D. Sharma
Publikationsdatum
25.08.2018
Verlag
Springer Paris
Erschienen in
Hernia / Ausgabe 6/2018
Print ISSN: 1265-4906
Elektronische ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-018-1811-3

Weitere Artikel der Ausgabe 6/2018

Hernia 6/2018 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.