Skip to main content
Erschienen in: Magnetic Resonance Materials in Physics, Biology and Medicine 1/2017

08.08.2016 | Research Article

Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities

verfasst von: Sergios Gatidis, Hansjörg Graf, Jakob Weiß, Alto Stemmer, Berthold Kiefer, Konstantin Nikolaou, Mike Notohamiprodjo, Petros Martirosian

Erschienen in: Magnetic Resonance Materials in Physics, Biology and Medicine | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Objective

Our objective was to compare available techniques reducing artifacts in echo planar imaging (EPI)-based diffusion-weighed magnetic resonance imaging MRI (DWI) of the neck at 3 Tesla caused by B0-field inhomogeneities.

Materials and methods

A cylindrical fat–water phantom was equipped with a Maxwell coil allowing for additional linear B0-field variations in z-direction. The effect of increasing strength of this superimposed gradient on image quality was observed using a standard single-shot EPI-based DWI sequence (sEPI), a zoomed single-shot EPI sequence (zEPI), a readout-segmented EPI sequence (rsEPI), and an sEPI sequence with integrated dynamic shimming (intEPI) on a 3-Tesla system. Additionally, ten volunteers were examined over the neck region using these techniques. Image quality was assessed by two radiologists. Scan durations were recorded.

Results

With increasing strength of the external gradient, marked distortions, signal loss, and failure of fat suppression were observed using sEPI, zEPI, and rsEPI. These artifacts were markedly reduced using intEPI. Significantly better in vivo image quality was also observed using intEPI compared with the other techniques. Scan time of intEPI was similar to sEPI and zEPI and shorter than rsEPI.

Conclusion

The use of integrated 2D shim and frequency adjustment for EPI-based DWI results in a significant improvement in image quality of the head/neck region at 3 Tesla. Combining integrated shimming with rsEPI or zEPI can be expected to provide additional improvements.
Literatur
1.
Zurück zum Zitat Padhani AR, Koh DM, Collins DJ (2011) Whole-body diffusion-weighted MR imaging in cancer: current status and research directions. Radiology 261(3):700–718CrossRefPubMed Padhani AR, Koh DM, Collins DJ (2011) Whole-body diffusion-weighted MR imaging in cancer: current status and research directions. Radiology 261(3):700–718CrossRefPubMed
2.
Zurück zum Zitat Fung SH, Roccatagliata L, Gonzalez RG, Schaefer PW (2011) MR diffusion imaging in ischemic stroke. Neuroimaging Clin N Am 21(2):345–377 Fung SH, Roccatagliata L, Gonzalez RG, Schaefer PW (2011) MR diffusion imaging in ischemic stroke. Neuroimaging Clin N Am 21(2):345–377
3.
Zurück zum Zitat Thoeny HC, De Keyzer F, King AD (2012) Diffusion-weighted MR imaging in the head and neck. Radiology 263(1):19–32CrossRefPubMed Thoeny HC, De Keyzer F, King AD (2012) Diffusion-weighted MR imaging in the head and neck. Radiology 263(1):19–32CrossRefPubMed
4.
Zurück zum Zitat Filipe JP, Curvo-Semedo L, Casalta-Lopes J, Marques MC, Caseiro-Alves F (2013) Diffusion-weighted imaging of the liver: usefulness of ADC values in the differential diagnosis of focal lesions and effect of ROI methods on ADC measurements. Magn Reson Mater Phy 26(3):303–312CrossRef Filipe JP, Curvo-Semedo L, Casalta-Lopes J, Marques MC, Caseiro-Alves F (2013) Diffusion-weighted imaging of the liver: usefulness of ADC values in the differential diagnosis of focal lesions and effect of ROI methods on ADC measurements. Magn Reson Mater Phy 26(3):303–312CrossRef
5.
Zurück zum Zitat Skare S, Newbould RD, Clayton DB, Albers GW, Nagle S, Bammer R (2007) Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise. Magn Reson Med 57(5):881–890CrossRefPubMedPubMedCentral Skare S, Newbould RD, Clayton DB, Albers GW, Nagle S, Bammer R (2007) Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise. Magn Reson Med 57(5):881–890CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Ahlhelm F, Hagen T, Schneider G, Dorenbeck U, Nabhan A, Reith W (2004) ADC mapping of normal human brain. Med Sci Monit 10(11):MT121–M125 Ahlhelm F, Hagen T, Schneider G, Dorenbeck U, Nabhan A, Reith W (2004) ADC mapping of normal human brain. Med Sci Monit 10(11):MT121–M125
7.
Zurück zum Zitat Yoshikawa T, Kawamitsu H, Mitchell DG, Ohno Y, Ku Y, Seo Y, Fujii M, Sugimura K (2006) ADC measurement of abdominal organs and lesions using parallel imaging technique. AJR Am J Roentgenol 187(6):1521–1530CrossRefPubMed Yoshikawa T, Kawamitsu H, Mitchell DG, Ohno Y, Ku Y, Seo Y, Fujii M, Sugimura K (2006) ADC measurement of abdominal organs and lesions using parallel imaging technique. AJR Am J Roentgenol 187(6):1521–1530CrossRefPubMed
8.
Zurück zum Zitat Porter DA, Heidemann RM (2009) High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition. Magn Reson Med 62(2):468–475CrossRefPubMed Porter DA, Heidemann RM (2009) High resolution diffusion-weighted imaging using readout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition. Magn Reson Med 62(2):468–475CrossRefPubMed
9.
Zurück zum Zitat Riffel P, Michaely HJ, Morelli JN, Pfeuffer J, Attenberger UI, Schoenberg SO, Haneder S (2014) Zoomed EPI-DWI of the pancreas using two-dimensional spatially-selective radiofrequency excitation pulses. PLoS One 9(3):e89468CrossRefPubMedPubMedCentral Riffel P, Michaely HJ, Morelli JN, Pfeuffer J, Attenberger UI, Schoenberg SO, Haneder S (2014) Zoomed EPI-DWI of the pancreas using two-dimensional spatially-selective radiofrequency excitation pulses. PLoS One 9(3):e89468CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Thierfelder KM, Scherr MK, Notohamiprodjo M, Weiss J, Dietrich O, Mueller-Lisse UG, Pfeuffer J, Nikolaou K, Theisen D (2014) Diffusion-weighted MRI of the prostate: advantages of Zoomed EPI with parallel-transmit-accelerated 2D-selective excitation imaging. Eur Radiol 24(12):3233–3241CrossRefPubMed Thierfelder KM, Scherr MK, Notohamiprodjo M, Weiss J, Dietrich O, Mueller-Lisse UG, Pfeuffer J, Nikolaou K, Theisen D (2014) Diffusion-weighted MRI of the prostate: advantages of Zoomed EPI with parallel-transmit-accelerated 2D-selective excitation imaging. Eur Radiol 24(12):3233–3241CrossRefPubMed
11.
Zurück zum Zitat Holdsworth SJ, Yeom K, Skare S, Gentles AJ, Barnes PD, Bammer R (2011) Clinical application of readout-segmented- echo-planar imaging for diffusion-weighted imaging in pediatric brain. AJNR Am J Neuroradiol 32(7):1274–1279CrossRefPubMedPubMedCentral Holdsworth SJ, Yeom K, Skare S, Gentles AJ, Barnes PD, Bammer R (2011) Clinical application of readout-segmented- echo-planar imaging for diffusion-weighted imaging in pediatric brain. AJNR Am J Neuroradiol 32(7):1274–1279CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Blamire AM, Rothman DL, Nixon T (1996) Dynamic shim updating: a new approach towards optimized whole brain shimming. Magn Reson Med 36(1):159–165CrossRefPubMed Blamire AM, Rothman DL, Nixon T (1996) Dynamic shim updating: a new approach towards optimized whole brain shimming. Magn Reson Med 36(1):159–165CrossRefPubMed
13.
Zurück zum Zitat Lee SK, Tan ET, Govenkar A, Hancu I (2014) Dynamic slice-dependent shim and center frequency update in 3 T breast diffusion weighted imaging. Magn Reson Med 71(5):1813–1818CrossRefPubMed Lee SK, Tan ET, Govenkar A, Hancu I (2014) Dynamic slice-dependent shim and center frequency update in 3 T breast diffusion weighted imaging. Magn Reson Med 71(5):1813–1818CrossRefPubMed
14.
Zurück zum Zitat Zhang H, Xue H, Alto S, Hui L, Kannengiesser S, Berthold K, Jin Z (2015) Integrated shimming improves lesion detection in whole-body diffusion-weighted examinations of patients with plasma disorder at 3 T. Invest Radiol 51(5):297–305 Zhang H, Xue H, Alto S, Hui L, Kannengiesser S, Berthold K, Jin Z (2015) Integrated shimming improves lesion detection in whole-body diffusion-weighted examinations of patients with plasma disorder at 3 T. Invest Radiol 51(5):297–305
15.
Zurück zum Zitat Koyasu S, Iima M, Umeoka S, Morisawa N, Porter DA, Ito J, Le Bihan D, Togashi K (2014) The clinical utility of reduced-distortion readout-segmented echo-planar imaging in the head and neck region: initial experience. Eur Radiol 24(12):3088–3096CrossRefPubMed Koyasu S, Iima M, Umeoka S, Morisawa N, Porter DA, Ito J, Le Bihan D, Togashi K (2014) The clinical utility of reduced-distortion readout-segmented echo-planar imaging in the head and neck region: initial experience. Eur Radiol 24(12):3088–3096CrossRefPubMed
16.
Zurück zum Zitat Schick F, Forster J, Machann J, Huppert P, Claussen CD (1997) Highly selective water and fat imaging applying multislice sequences without sensitivity to B1 field inhomogeneities. Magn Reson Med 38(2):269–274CrossRefPubMed Schick F, Forster J, Machann J, Huppert P, Claussen CD (1997) Highly selective water and fat imaging applying multislice sequences without sensitivity to B1 field inhomogeneities. Magn Reson Med 38(2):269–274CrossRefPubMed
17.
Zurück zum Zitat Barth BK, Cornelius A, Nanz D, Eberli D, Donati OF (2015) Diffusion-weighted imaging of the prostate: image quality and geometric distortion of readout-segmented versus selective-excitation accelerated acquisitions. Invest Radiol 50(11):785–791CrossRefPubMed Barth BK, Cornelius A, Nanz D, Eberli D, Donati OF (2015) Diffusion-weighted imaging of the prostate: image quality and geometric distortion of readout-segmented versus selective-excitation accelerated acquisitions. Invest Radiol 50(11):785–791CrossRefPubMed
18.
Zurück zum Zitat Stemmer A, Kiefer B (2015) Combination of integrated slice-specific dynamic shimming and pixel-wise unwarping of residual epi distortions. Proc Intl Soc Mag Reson, Med Stemmer A, Kiefer B (2015) Combination of integrated slice-specific dynamic shimming and pixel-wise unwarping of residual epi distortions. Proc Intl Soc Mag Reson, Med
Metadaten
Titel
Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities
verfasst von
Sergios Gatidis
Hansjörg Graf
Jakob Weiß
Alto Stemmer
Berthold Kiefer
Konstantin Nikolaou
Mike Notohamiprodjo
Petros Martirosian
Publikationsdatum
08.08.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Magnetic Resonance Materials in Physics, Biology and Medicine / Ausgabe 1/2017
Print ISSN: 0968-5243
Elektronische ISSN: 1352-8661
DOI
https://doi.org/10.1007/s10334-016-0582-z

Weitere Artikel der Ausgabe 1/2017

Magnetic Resonance Materials in Physics, Biology and Medicine 1/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.