Skip to main content
Erschienen in: Journal of Inherited Metabolic Disease 3/2011

01.06.2011 | SSIEM Symposium 2010

The use of continuous glucose monitoring in the practical management of glycogen storage disorders

verfasst von: Fiona J. White, Simon A. Jones

Erschienen in: Journal of Inherited Metabolic Disease | Ausgabe 3/2011

Einloggen, um Zugang zu erhalten

Abstract

Continuous glucose monitoring systems (CGMS) are now in widespread use in diabetes management with an increasing evidence base. There are few reports of their use in GSD. Liver glycogen storage disorders (GSDs) are most often managed by intensive dietary regimens. Risks of over and under-treatment remain. We describe our use of CGMS in a cohort of GSD patients, the results obtained and the frequency of complications. Our experience is that CGM is a reliable, well accepted and valid tool in the monitoring of GSD patients and allows for assessment of blood sugar control in the ‘real-life’ setting, unlike hospital admissions. Combining CGM with urine ketone and / or blood lactate measurements, again at home, improves the investigation yet further. It is possible to perform CGM for periods including both schooldays and weekends, and also to change the dietary regimen during the period of monitoring to reduce the frequency of assessments. Risks of decreased reliability in the low range of blood sugars may be outweighed by the increased validity of the patient being in the home environment, with a normal diet and activity schedule.
Literatur
Zurück zum Zitat Bergenstal RM, Tamborlane WV, Ahmann A et al. (2010) Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med 363(4):311–320PubMedCrossRef Bergenstal RM, Tamborlane WV, Ahmann A et al. (2010) Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med 363(4):311–320PubMedCrossRef
Zurück zum Zitat De Block C, Manuel-y-Keenoy B, Van Gaal L (2008) A review of current evidence with continuous glucose monitoring in patients with diabetes. J Diabetes Sci Technol 2(4):718–727 De Block C, Manuel-y-Keenoy B, Van Gaal L (2008) A review of current evidence with continuous glucose monitoring in patients with diabetes. J Diabetes Sci Technol 2(4):718–727
Zurück zum Zitat Hershkovitz E, Rachmel A, Ben-Zaken H, Phillip M (2001) Continuous glucose monitoring in children with glycogen storage disease type I. J Inherit Metab Dis 24(8):863–869PubMedCrossRef Hershkovitz E, Rachmel A, Ben-Zaken H, Phillip M (2001) Continuous glucose monitoring in children with glycogen storage disease type I. J Inherit Metab Dis 24(8):863–869PubMedCrossRef
Zurück zum Zitat Maran A, Crepaldi C, Avogaro A et al. (2004) Continuous glucose monitoring in conditions other than diabetes. Diabetes Metab Res Rev 20(S2):S50–S55PubMedCrossRef Maran A, Crepaldi C, Avogaro A et al. (2004) Continuous glucose monitoring in conditions other than diabetes. Diabetes Metab Res Rev 20(S2):S50–S55PubMedCrossRef
Zurück zum Zitat Medtronic (2009) Six day sensor trial, data on file. *MMT-7002/7003 Medtronic (2009) Six day sensor trial, data on file. *MMT-7002/7003
Zurück zum Zitat Rake JP, Visser G, Labrune P, Leonard JV, Ullrich K, Smit GP (2002) Guidelines for management of glycogen storage disease type I – European study on glycogen storage disease type I (ESGSD I). Eur J Pediatr 161(Suppl 1):S112–S119PubMedCrossRef Rake JP, Visser G, Labrune P, Leonard JV, Ullrich K, Smit GP (2002) Guidelines for management of glycogen storage disease type I – European study on glycogen storage disease type I (ESGSD I). Eur J Pediatr 161(Suppl 1):S112–S119PubMedCrossRef
Zurück zum Zitat Saunders AC, Feldman HA, Correia CE, Weinstein DA (2005) Clinical evaluation of a portable lactate meter in type I glycogen storage disease. J Inherit Metab Dis 28:695–701PubMedCrossRef Saunders AC, Feldman HA, Correia CE, Weinstein DA (2005) Clinical evaluation of a portable lactate meter in type I glycogen storage disease. J Inherit Metab Dis 28:695–701PubMedCrossRef
Zurück zum Zitat Visser G, Rake JP, Labrune P, Leonard JV, Moses S, Ullrich K et al. (2002) Consensus guidelines for management of glycogen storage disease type 1b – European Study on Glycogen Storage Disease Type 1. Eur J Pediatr 161(Suppl 1):S120–S123PubMed Visser G, Rake JP, Labrune P, Leonard JV, Moses S, Ullrich K et al. (2002) Consensus guidelines for management of glycogen storage disease type 1b – European Study on Glycogen Storage Disease Type 1. Eur J Pediatr 161(Suppl 1):S120–S123PubMed
Metadaten
Titel
The use of continuous glucose monitoring in the practical management of glycogen storage disorders
verfasst von
Fiona J. White
Simon A. Jones
Publikationsdatum
01.06.2011
Verlag
Springer Netherlands
Erschienen in
Journal of Inherited Metabolic Disease / Ausgabe 3/2011
Print ISSN: 0141-8955
Elektronische ISSN: 1573-2665
DOI
https://doi.org/10.1007/s10545-011-9335-3

Weitere Artikel der Ausgabe 3/2011

Journal of Inherited Metabolic Disease 3/2011 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Reizdarmsyndrom: Diäten wirksamer als Medikamente

29.04.2024 Reizdarmsyndrom Nachrichten

Bei Reizdarmsyndrom scheinen Diäten, wie etwa die FODMAP-arme oder die kohlenhydratreduzierte Ernährung, effektiver als eine medikamentöse Therapie zu sein. Das hat eine Studie aus Schweden ergeben, die die drei Therapieoptionen im direkten Vergleich analysierte.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.