Abstract

The implantation of intracoronary stents is currently the standard approach for the treatment of coronary atherosclerotic disease. The widespread adoption of this technology has boosted an intensive research activity in this domain, with continuous improvements in the design of these devices, aiming at reducing problems of restenosis (re-narrowing of the stented segment) and thrombosis (sudden occlusion due to thrombus formation). Recently, a new, light-based intracoronary imaging modality, optical coherence tomography (OCT), was developed and introduced into clinical practice. Due to its very high axial resolution (10–15 μm), it allows for in vivo evaluation of both stent strut apposition and neointima coverage (a marker of healing of the treated segment). As such, it provides valuable information on proper stent deployment, on the behaviour of different stent types in-vivo and on the effect of new types of stents (e.g. drug-eluting stents) on vessel wall healing. However, the major drawback of the current OCT methodology is that analysis of these images requires a tremendous amount of—currently manual—post-processing. In this manuscript, an algorithm is presented that allows for fully automated analysis of stent strut apposition and coverage in coronary arteries. The vessel lumen and stent struts are automatically detected and segmented through analysis of the intensity profiles of the A-lines. From these data, apposition and coverage can then be measured automatically. The algorithm was validated using manual assessments by two experienced operators as a reference. High Pearson’s correlation coefficients were found (R = 0.96–0.97) between the automated and manual measurements while Bland–Altman analysis showed no significant bias with good limits of agreement. As such, it was shown that the presented algorithm provides a robust and fast tool to automatically estimate apposition and coverage of stent struts in in-vivo OCT pullbacks. This will be important for the integration of this technology in clinical routine and for the analysis of datasets of larger clinical trials.
Literatur
1.
Zurück zum Zitat Bezerra HG, Costa MA, Guagliumi G, Rollins AM, Simon D (2009) Intracoronary optical coherence tomography: a comprehensive review. JACC Cardiovasc Interv 2:1035–1046 Bezerra HG, Costa MA, Guagliumi G, Rollins AM, Simon D (2009) Intracoronary optical coherence tomography: a comprehensive review. JACC Cardiovasc Interv 2:1035–1046
2.
Zurück zum Zitat Prati F, Regard E, Mintz GS, Arbustini E, Di Mario C, Jang I, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW J (2009) Expert review document on methodology, terminology, and clinical application of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31:401–415PubMedCrossRef Prati F, Regard E, Mintz GS, Arbustini E, Di Mario C, Jang I, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW J (2009) Expert review document on methodology, terminology, and clinical application of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31:401–415PubMedCrossRef
3.
Zurück zum Zitat Terashima M, Rathore S, Suzuki Y, Nakayama Y, Kaneda H, Nasu H, Habara M, Katoh O, Suzuki T (2009) Accuracy and reproducibility of stent-strut thickness determined by optical coherence tomography. J Invasive Cardiol 21:602–605 Terashima M, Rathore S, Suzuki Y, Nakayama Y, Kaneda H, Nasu H, Habara M, Katoh O, Suzuki T (2009) Accuracy and reproducibility of stent-strut thickness determined by optical coherence tomography. J Invasive Cardiol 21:602–605
4.
Zurück zum Zitat Tearney G J et al (2008) Three dimensional coronary artery microscopy by intra coronary optical coherence tomography. JACC Cardiovasc Imaging 1:752–761 Tearney G J et al (2008) Three dimensional coronary artery microscopy by intra coronary optical coherence tomography. JACC Cardiovasc Imaging 1:752–761
5.
Zurück zum Zitat Kotani J, Awata M, Nanto S, Uematsu M, Oshima F, Minamiguchi H, Mintz G S, Nagata S (2006) Incomplete neointima coverage of Sirolimus-eluting stents angioscopic findings. JACC Cardiovasc Interv 47:2108–2111 Kotani J, Awata M, Nanto S, Uematsu M, Oshima F, Minamiguchi H, Mintz G S, Nagata S (2006) Incomplete neointima coverage of Sirolimus-eluting stents angioscopic findings. JACC Cardiovasc Interv 47:2108–2111
6.
Zurück zum Zitat Hong M et al (2004) Incidence, mechanism, predictors and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation 109:881–886PubMedCrossRef Hong M et al (2004) Incidence, mechanism, predictors and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation 109:881–886PubMedCrossRef
7.
Zurück zum Zitat Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Herman KG, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:435–441CrossRef Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Herman KG, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:435–441CrossRef
8.
Zurück zum Zitat G Guagliumi and V Sirbu (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247 G Guagliumi and V Sirbu (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247
9.
Zurück zum Zitat Murata A et al (2010) Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation. JACC Cardiovasc Imaging 3:76–84 Murata A et al (2010) Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation. JACC Cardiovasc Imaging 3:76–84
10.
Zurück zum Zitat Unal G, Gurmeric S and Carlier S G (2009) Stent implant follow-up in intravascular optical coherence tomography images. Int J Cardiovasc Imaging. 6:1569–1573 Unal G, Gurmeric S and Carlier S G (2009) Stent implant follow-up in intravascular optical coherence tomography images. Int J Cardiovasc Imaging. 6:1569–1573
11.
Zurück zum Zitat Sawada T et al (2009) Factors that influence measurement and accurate evaluation of stent apposition by optical coherence tomography. Cardiovasc interv 73:1841–1847 Sawada T et al (2009) Factors that influence measurement and accurate evaluation of stent apposition by optical coherence tomography. Cardiovasc interv 73:1841–1847
12.
Zurück zum Zitat Paul Dierckx (1993) Curve and surface fitting with splines, monograph on numerical analysis. Oxford Science Publication, Oxford, pp 75–118 Paul Dierckx (1993) Curve and surface fitting with splines, monograph on numerical analysis. Oxford Science Publication, Oxford, pp 75–118
13.
Zurück zum Zitat WK Pratt (2001) Digital image processing: PIKS inside, 3rd edn. Wiley Inc, Hoboken, New Jersey, pp 393–398, 647–672 WK Pratt (2001) Digital image processing: PIKS inside, 3rd edn. Wiley Inc, Hoboken, New Jersey, pp 393–398, 647–672
Metadaten
Titel
Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverage
verfasst von
G. J. Ughi
T. Adriaenssens
K. Onsea
P. Kayaert
C. Dubois
P. Sinnaeve
M. Coosemans
W. Desmet
J. D’hooge
Publikationsdatum
01.02.2012
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 2/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9824-3

Weitere Artikel der Ausgabe 2/2012

The International Journal of Cardiovascular Imaging 2/2012 Zur Ausgabe

Bei Herzinsuffizienz muss „Eisenmangel“ neu definiert werden!

16.05.2024 Herzinsuffizienz Nachrichten

Bei chronischer Herzinsuffizienz macht es einem internationalen Expertenteam zufolge wenig Sinn, die Diagnose „Eisenmangel“ am Serumferritin festzumachen. Das Team schlägt vor, sich lieber an die Transferrinsättigung zu halten.

Herzinfarkt mit 85 – trotzdem noch intensive Lipidsenkung?

16.05.2024 Hypercholesterinämie Nachrichten

Profitieren nach einem akuten Myokardinfarkt auch Betroffene über 80 Jahre noch von einer intensiven Lipidsenkung zur Sekundärprävention? Um diese Frage zu beantworten, wurden jetzt Registerdaten aus Frankreich ausgewertet.

ADHS-Medikation erhöht das kardiovaskuläre Risiko

16.05.2024 Herzinsuffizienz Nachrichten

Erwachsene, die Medikamente gegen das Aufmerksamkeitsdefizit-Hyperaktivitätssyndrom einnehmen, laufen offenbar erhöhte Gefahr, an Herzschwäche zu erkranken oder einen Schlaganfall zu erleiden. Es scheint eine Dosis-Wirkungs-Beziehung zu bestehen.

LDL-Cholesterin kann ApoB als Risikomarker nicht ersetzen

16.05.2024 Hypercholesterinämie Nachrichten

Apolipoprotein B (ApoB) ist ein genauer Risikomarker für atherosklerotisch bedingte Erkrankungen. Aber das LDL-Cholesterin doch auch – lohnt sich also die ApoB-Messung überhaupt?

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.