01.08.2010 | TECHNICAL NOTE

Essentials of photometry for clinical electrophysiology of vision

verfasst von: Daphne L. McCulloch, Ruth Hamilton

Erschienen in: Documenta Ophthalmologica | Ausgabe 1/2010

Einloggen, um Zugang zu erhalten

Abstract

Electrophysiological testing of the visual system requires familiarity with photometry. This technical note outlines the concepts of photometry with a focus on information relevant to clinical ERG and VEP testing. Topics include photometric quantities, consideration of pupil size, specification of brief extended flash stimuli, and the influence of the spectral composition of visual stimuli. Standard units and terms are explained in the context of the ISCEV standards and guidelines for clinical electrophysiology of vision.
Fußnoten
1
The full quote in context: “Boswell. ‘Then, Sir, what is poetry?’ Johnson. ‘Why, Sir, it is much easier to say what it is not. We all know what light is; but it is not easy to tell what it is.’” 12 April 1776, James Boswell, Life of Johnson (1791).
 
Literatur
1.
Zurück zum Zitat Bouguer P (1760) Traité d’Optique sur la Gradation de la Lumière. Académie des Sciences, Paris Bouguer P (1760) Traité d’Optique sur la Gradation de la Lumière. Académie des Sciences, Paris
2.
Zurück zum Zitat Lambert JH (1760) Photometria sive de mensura et gradibus luminis, colorum et umbrae. Eberhard Klett, Augsburg Lambert JH (1760) Photometria sive de mensura et gradibus luminis, colorum et umbrae. Eberhard Klett, Augsburg
3.
Zurück zum Zitat Saidman J (1933) Sur la visibilité de l’ultraviolet jusqu’à la longuer de l’onde 3130 A [313 nm]. C R Hebd Séances Acad Sci 196:1537–1539 Saidman J (1933) Sur la visibilité de l’ultraviolet jusqu’à la longuer de l’onde 3130 A [313 nm]. C R Hebd Séances Acad Sci 196:1537–1539
4.
Zurück zum Zitat Gaydon AG (1938) Colour sensations produced by ultraviolet light. J Phys Soc (London) 50:714–720CrossRef Gaydon AG (1938) Colour sensations produced by ultraviolet light. J Phys Soc (London) 50:714–720CrossRef
5.
Zurück zum Zitat Calibration Standard Committee of ISCEV: Brigell M (chair), Bach M, Barber C, Moskowitz A, Robson JG (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193 Calibration Standard Committee of ISCEV: Brigell M (chair), Bach M, Barber C, Moskowitz A, Robson JG (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193
6.
Zurück zum Zitat Wyszecki G, Stiles WS (2000) Color science, 2nd edn. Wiley, New York Wyszecki G, Stiles WS (2000) Color science, 2nd edn. Wiley, New York
7.
Zurück zum Zitat Ohno Y (2006) Handbook of optoelectronics. Taylor and Francis, New York Ohno Y (2006) Handbook of optoelectronics. Taylor and Francis, New York
8.
Zurück zum Zitat Ohta N, Robertson AR (2005) Colorimetry: fundamentals and applications. Wiley, New YorkCrossRef Ohta N, Robertson AR (2005) Colorimetry: fundamentals and applications. Wiley, New YorkCrossRef
9.
Zurück zum Zitat Commission Internationale de l’Eclairage (1990) CIE 1988 2° Spectral luminous efficiency function for photopic vision, No. 86. CIE, Vienna Commission Internationale de l’Eclairage (1990) CIE 1988 2° Spectral luminous efficiency function for photopic vision, No. 86. CIE, Vienna
10.
Zurück zum Zitat Commission Internationale d’Eclairage (2005) CIE 10 degree photopic photometric observer, No. 165. CIE, Vienna Commission Internationale d’Eclairage (2005) CIE 10 degree photopic photometric observer, No. 165. CIE, Vienna
11.
Zurück zum Zitat Commission Internationale d’Eclairage (1951) CIE Proceedings 1951. Bureau Central de la CIE, New York Commission Internationale d’Eclairage (1951) CIE Proceedings 1951. Bureau Central de la CIE, New York
12.
Zurück zum Zitat Kawasaki K, Tanabe J, Wakabayashi K, Shirao Y (2006). In: Heckenlively JR, Arden GB (eds) Principles and practice of clinical electrophysiology of vision, 2nd edn. MIT Press, Cambridge, pp 585–591 Kawasaki K, Tanabe J, Wakabayashi K, Shirao Y (2006). In: Heckenlively JR, Arden GB (eds) Principles and practice of clinical electrophysiology of vision, 2nd edn. MIT Press, Cambridge, pp 585–591
13.
Zurück zum Zitat Bureau Internationale des Poids et Mesures (1979) Comptes Rendus des Séances de la 16e Conférence Générale des Poids et Mesures. Résolution 3. Pavilion de Breteuil, F-92310 Sèvres, France Bureau Internationale des Poids et Mesures (1979) Comptes Rendus des Séances de la 16e Conférence Générale des Poids et Mesures. Résolution 3. Pavilion de Breteuil, F-92310 Sèvres, France
14.
Zurück zum Zitat Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP, Vaegan (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 120:111–119 Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP, Vaegan (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 120:111–119
15.
Zurück zum Zitat Brown M, Marmor MF, Vaegan, Zrenner E, Brigell MG, Bach M (2004) ISCEV standard for clinical electro-oculography (EOG). Doc Ophthalmol 113:205–212 Brown M, Marmor MF, Vaegan, Zrenner E, Brigell MG, Bach M (2004) ISCEV standard for clinical electro-oculography (EOG). Doc Ophthalmol 113:205–212
16.
Zurück zum Zitat Holder GE, Brigell MG, Hawlina M, Meigen T, Bach M (2007) ISCEV Standard for clinical pattern electroretinography (2007 update). Doc Ophthalmol 114:111–116CrossRefPubMed Holder GE, Brigell MG, Hawlina M, Meigen T, Bach M (2007) ISCEV Standard for clinical pattern electroretinography (2007 update). Doc Ophthalmol 114:111–116CrossRefPubMed
17.
Zurück zum Zitat Hood DC, Bach M, Brigell MG, Keating D, Kondo M, Lyons JS et al. (2007) ISCEV Guidelines for clinical multifocal electroretinography (2007 edition). Doc Ophthalmol 2007 Hood DC, Bach M, Brigell MG, Keating D, Kondo M, Lyons JS et al. (2007) ISCEV Guidelines for clinical multifocal electroretinography (2007 edition). Doc Ophthalmol 2007
18.
Zurück zum Zitat Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell MG, Bach M (2009) Standard for clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell MG, Bach M (2009) Standard for clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed
19.
Zurück zum Zitat Pugh EN (1988) Perception and motivation. In: Atkinson RC, Herrnstein RJ, Lindzey G, Luce RD (eds) Stevens’ handbook of experimental psychology, vol 1, 2nd edn. Wiley, New York, pp 75–163 Pugh EN (1988) Perception and motivation. In: Atkinson RC, Herrnstein RJ, Lindzey G, Luce RD (eds) Stevens’ handbook of experimental psychology, vol 1, 2nd edn. Wiley, New York, pp 75–163
20.
Zurück zum Zitat Gullstrand A (1909). In: von Helmholtz H (ed) Physiological optics. Voss, Hamburg, pp 350–358 Gullstrand A (1909). In: von Helmholtz H (ed) Physiological optics. Voss, Hamburg, pp 350–358
21.
Zurück zum Zitat Mactier H, Maroo S, Bradnam MS, Hamilton R (2008) Ocular biometry in preterm infants: implications for estimation of retinal illuminance. Invest Ophthalmol Vis Sci 49:453–457CrossRefPubMed Mactier H, Maroo S, Bradnam MS, Hamilton R (2008) Ocular biometry in preterm infants: implications for estimation of retinal illuminance. Invest Ophthalmol Vis Sci 49:453–457CrossRefPubMed
22.
Zurück zum Zitat Hansen RM, Fulton AB (1989) Psychophysical estimates of ocular media density of human infants. Vis Res 29:687–690CrossRefPubMed Hansen RM, Fulton AB (1989) Psychophysical estimates of ocular media density of human infants. Vis Res 29:687–690CrossRefPubMed
23.
Zurück zum Zitat van de Kraats J, van Norren D (2007) Optical density of the aging human ocular media in the visible and the UV. J Opt Soc America A 24:1842–1857CrossRef van de Kraats J, van Norren D (2007) Optical density of the aging human ocular media in the visible and the UV. J Opt Soc America A 24:1842–1857CrossRef
24.
Zurück zum Zitat Troland LT (1917) On the measurement of visual stimulation intensities. J Exp Psych 2:1–33CrossRef Troland LT (1917) On the measurement of visual stimulation intensities. J Exp Psych 2:1–33CrossRef
25.
Zurück zum Zitat Makous W (1999). In: Carpenter RHS, Robson JG (eds) Vision research: a practical guide to laboratory methods. Oxford University Press, Oxford, pp 1–49 Makous W (1999). In: Carpenter RHS, Robson JG (eds) Vision research: a practical guide to laboratory methods. Oxford University Press, Oxford, pp 1–49
26.
Zurück zum Zitat Robson JG (1999). In: Carpenter RHS, Robson JG (eds) Vision research: a practical guide to laboratory methods. Oxford University Press, Oxford, pp 50-80 Robson JG (1999). In: Carpenter RHS, Robson JG (eds) Vision research: a practical guide to laboratory methods. Oxford University Press, Oxford, pp 50-80
27.
Zurück zum Zitat Castelletto S, Rastello ML (1998) Luminous and photon standards by trap detectors. IEEE Trans Instrum Meas 47:900–906CrossRef Castelletto S, Rastello ML (1998) Luminous and photon standards by trap detectors. IEEE Trans Instrum Meas 47:900–906CrossRef
28.
Zurück zum Zitat Stiles WS, Crawford BH (1933) The luminous efficiency of rays entering the eye pupil at different points. Proc R Soc Lond B 112:428–450CrossRef Stiles WS, Crawford BH (1933) The luminous efficiency of rays entering the eye pupil at different points. Proc R Soc Lond B 112:428–450CrossRef
29.
Zurück zum Zitat Metcalf H (1965) Stiles-Crawford apodization. J Opt Soc Am 55:72–74CrossRef Metcalf H (1965) Stiles-Crawford apodization. J Opt Soc Am 55:72–74CrossRef
30.
Zurück zum Zitat Gonzalez P, Parks S, Dolan F, Keating D (2004) The effects of pupil size on the multifocal electroretinogram. Doc Ophthalmol 109:67–72CrossRefPubMed Gonzalez P, Parks S, Dolan F, Keating D (2004) The effects of pupil size on the multifocal electroretinogram. Doc Ophthalmol 109:67–72CrossRefPubMed
31.
Zurück zum Zitat Poloschek CM, Bach M (2009) Can we do without mydriasis in multifocal ERG recordings? Doc Ophthalmol 118:121–128CrossRefPubMed Poloschek CM, Bach M (2009) Can we do without mydriasis in multifocal ERG recordings? Doc Ophthalmol 118:121–128CrossRefPubMed
32.
Zurück zum Zitat Alpern M, Ching CC, Kitahara K (1983) Directional sensitivity of the retinal rods. J Physiol 343:577–592PubMed Alpern M, Ching CC, Kitahara K (1983) Directional sensitivity of the retinal rods. J Physiol 343:577–592PubMed
33.
Metadaten
Titel
Essentials of photometry for clinical electrophysiology of vision
verfasst von
Daphne L. McCulloch
Ruth Hamilton
Publikationsdatum
01.08.2010
Verlag
Springer-Verlag
Erschienen in
Documenta Ophthalmologica / Ausgabe 1/2010
Print ISSN: 0012-4486
Elektronische ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-010-9233-2

Weitere Artikel der Ausgabe 1/2010

Documenta Ophthalmologica 1/2010 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.