Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 6/2016

01.06.2016 | Original Article

Three-dimensional quantitative assessment of ablation margins based on registration of pre- and post-procedural MRI and distance map

verfasst von: Soichiro Tani, Servet Tatli, Nobuhiko Hata, Xavier Garcia-Rojas, Olutayo I. Olubiyi, Stuart G. Silverman, Junichi Tokuda

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Contrast-enhanced MR images are widely used to confirm the adequacy of ablation margin after liver ablation for early prediction of local recurrence. However, quantitative assessment of the ablation margin by comparing pre- and post-procedural images remains challenging. We developed and tested a novel method for three-dimensional quantitative assessment of ablation margin based on non-rigid image registration and 3D distance map.

Methods

Our method was tested with pre- and post-procedural MR images acquired in 21 patients who underwent image-guided percutaneous liver ablation. The two images were co-registered using non-rigid intensity-based registration. After the tumor and ablation volumes were segmented, target volume coverage, percent of tumor coverage, and Dice similarity coefficient were calculated as metrics representing overall adequacy of ablation. In addition, 3D distance map around the tumor was computed and superimposed on the ablation volume to identify the area with insufficient margins. For patients with local recurrences, the follow-up images were registered to the post-procedural image. Three-dimensional minimum distance between the recurrence and the areas with insufficient margins was quantified.

Results

The percent tumor coverage for all nonrecurrent cases was 100 %. Five cases had tumor recurrences, and the 3D distance map revealed insufficient tumor coverage or a 0-mm margin. It also showed that two recurrences were remote to the insufficient margin.

Conclusions

Non-rigid registration and 3D distance map allow us to quantitatively evaluate the adequacy of the ablation margin after percutaneous liver ablation. The method may be useful to predict local recurrences immediately following ablation procedure.
Literatur
1.
Zurück zum Zitat Bowles BJ, Machi J, Limm WM, Severino R, Oishi AJ, Furumoto NL, Wong LL, Oishi RH (2001) Safety and efficacy of radiofrequency thermal ablation in advanced liver tumors. Archiv Surg (Chicago, Ill. : 1960) 136(8):864–869CrossRef Bowles BJ, Machi J, Limm WM, Severino R, Oishi AJ, Furumoto NL, Wong LL, Oishi RH (2001) Safety and efficacy of radiofrequency thermal ablation in advanced liver tumors. Archiv Surg (Chicago, Ill. : 1960) 136(8):864–869CrossRef
2.
Zurück zum Zitat Carrillo A, Duerk JL, Lewin JS, Wilson DL (2000) Semiautomatic 3-D image registration as applied to interventional MRI liver cancer treatment. IEEE Trans Med Imaging 19(3):175–185. doi:10.1109/42.845176 CrossRefPubMed Carrillo A, Duerk JL, Lewin JS, Wilson DL (2000) Semiautomatic 3-D image registration as applied to interventional MRI liver cancer treatment. IEEE Trans Med Imaging 19(3):175–185. doi:10.​1109/​42.​845176 CrossRefPubMed
4.
Zurück zum Zitat Chopra S, Dodd GD, Chintapalli KN, Leyendecker JR, Karahan OI, Rhim H (2001) Tumor recurrence after radiofrequency thermal ablation of hepatic tumors spectrum of findings on dual-phase contrast-enhanced CT. Am J Roentgenol 177(2):381–387CrossRef Chopra S, Dodd GD, Chintapalli KN, Leyendecker JR, Karahan OI, Rhim H (2001) Tumor recurrence after radiofrequency thermal ablation of hepatic tumors spectrum of findings on dual-phase contrast-enhanced CT. Am J Roentgenol 177(2):381–387CrossRef
6.
Zurück zum Zitat Claudon M, Dietrich CF, Choi BI, Cosgrove DO, Kudo M, Nolsøe CP, Piscaglia F, Wilson SR, Barr RG, Chammas MC, Chaubal NG, Chen MH, Clevert DA, Correas JM, Ding H, Forsberg F, Fowlkes JB, Gibson RN, Goldberg BB, Lassau N, Leen ELS, Mattrey RF, Moriyasu F, Solbiati L, Weskott HP, Xu HX (2013) Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) in the liver-update 2012. A WFUMB-EFSUMB initiative in cooperation with representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS. Ultrasound Med Biol 39(2):187–210. doi:10.1016/j.ultrasmedbio.2012.09.002 CrossRefPubMed Claudon M, Dietrich CF, Choi BI, Cosgrove DO, Kudo M, Nolsøe CP, Piscaglia F, Wilson SR, Barr RG, Chammas MC, Chaubal NG, Chen MH, Clevert DA, Correas JM, Ding H, Forsberg F, Fowlkes JB, Gibson RN, Goldberg BB, Lassau N, Leen ELS, Mattrey RF, Moriyasu F, Solbiati L, Weskott HP, Xu HX (2013) Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS) in the liver-update 2012. A WFUMB-EFSUMB initiative in cooperation with representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS. Ultrasound Med Biol 39(2):187–210. doi:10.​1016/​j.​ultrasmedbio.​2012.​09.​002 CrossRefPubMed
12.
Zurück zum Zitat Fujioka C, Horiguchi J, Ishifuro M, Kakizawa H, Kiguchi M, Matsuura N, Hieda M, Tachikake T, Alam F, Furukawa T, Ito K (2006) A feasibility study: evaluation of radiofrequency ablation therapy to hepatocellular carcinoma using image registration of preoperative and postoperative CT. Acad Radiol 13(8):986–994. doi:10.1016/j.acra.2006.05.011 CrossRefPubMed Fujioka C, Horiguchi J, Ishifuro M, Kakizawa H, Kiguchi M, Matsuura N, Hieda M, Tachikake T, Alam F, Furukawa T, Ito K (2006) A feasibility study: evaluation of radiofrequency ablation therapy to hepatocellular carcinoma using image registration of preoperative and postoperative CT. Acad Radiol 13(8):986–994. doi:10.​1016/​j.​acra.​2006.​05.​011 CrossRefPubMed
13.
Zurück zum Zitat Goldberg SN, Charboneau JW, Dodd GD, Dupuy DE, Gervais DA, Gillams AR, Kane RA, Lee FT, Livraghi T, McGahan JP, Rhim H, Silverman SG, Solbiati L, Vogl TJ, Wood BJ (2003) Image-guided tumor ablation: proposal for standardization of terms and reporting criteria1. Radiology 228(2):335–345. doi:10.1148/radiol.2282021787 CrossRefPubMed Goldberg SN, Charboneau JW, Dodd GD, Dupuy DE, Gervais DA, Gillams AR, Kane RA, Lee FT, Livraghi T, McGahan JP, Rhim H, Silverman SG, Solbiati L, Vogl TJ, Wood BJ (2003) Image-guided tumor ablation: proposal for standardization of terms and reporting criteria1. Radiology 228(2):335–345. doi:10.​1148/​radiol.​2282021787 CrossRefPubMed
15.
Zurück zum Zitat Hori T, Nagata K, Hasuike S, Onaga M, Motoda M, Moriuchi A, Iwakiri H, Uto H, Kato J, Ido A, Hayashi K, Tsubouchi H (2003) Risk factors for the local recurrence of hepatocellular carcinoma after a single session of percutaneous radiofrequency ablation. J Gastroenterol 38(10):977–981. doi:10.1007/s00535-003-1181-0 CrossRefPubMed Hori T, Nagata K, Hasuike S, Onaga M, Motoda M, Moriuchi A, Iwakiri H, Uto H, Kato J, Ido A, Hayashi K, Tsubouchi H (2003) Risk factors for the local recurrence of hepatocellular carcinoma after a single session of percutaneous radiofrequency ablation. J Gastroenterol 38(10):977–981. doi:10.​1007/​s00535-003-1181-0 CrossRefPubMed
16.
Zurück zum Zitat Kettenbach J, Köstler W, Rücklinger E, Gustorff B, Hüpfl M, Wolf F, Peer K, Weigner M, Lammer J, Müller W, Goldberg SN (2003) Percutaneous saline-enhanced radiofrequency ablation of unresectable hepatic tumors: Initial experience in 26 patients. Am J Roentgenol 180(June):1537–1545. doi:10.2214/ajr.180.6.1801537 CrossRef Kettenbach J, Köstler W, Rücklinger E, Gustorff B, Hüpfl M, Wolf F, Peer K, Weigner M, Lammer J, Müller W, Goldberg SN (2003) Percutaneous saline-enhanced radiofrequency ablation of unresectable hepatic tumors: Initial experience in 26 patients. Am J Roentgenol 180(June):1537–1545. doi:10.​2214/​ajr.​180.​6.​1801537 CrossRef
17.
Zurück zum Zitat Kim KW, Lee JM, Klotz E, Kim SJ, Kim SH, Kim JY, Han JK, Choi BI (2011) Safety margin assessment after radiofrequency ablation of the liver using registration of preprocedure and postprocedure CT images. Am J Roentgenol 196(5):565–572. doi:10.2214/AJR.10.5122 CrossRef Kim KW, Lee JM, Klotz E, Kim SJ, Kim SH, Kim JY, Han JK, Choi BI (2011) Safety margin assessment after radiofrequency ablation of the liver using registration of preprocedure and postprocedure CT images. Am J Roentgenol 196(5):565–572. doi:10.​2214/​AJR.​10.​5122 CrossRef
18.
Zurück zum Zitat Kim YS, Lee WJ, Rhim H, Lim HK, Choi D, Lee JY (2010) he minimal ablative margin of radiofrequency ablation of hepatocellular carcinoma greater than 2 and less than 5 cm needed to prevent local tumor progression: 3D quantitative assessment using CT image fusion. Am J Roentgenol 195:758–765. doi:10.2214/AJR.09.2954 Kim YS, Lee WJ, Rhim H, Lim HK, Choi D, Lee JY (2010) he minimal ablative margin of radiofrequency ablation of hepatocellular carcinoma greater than 2 and less than 5 cm needed to prevent local tumor progression: 3D quantitative assessment using CT image fusion. Am J Roentgenol 195:758–765. doi:10.​2214/​AJR.​09.​2954
19.
Zurück zum Zitat Ys Kim, Rhim H, Cho OK, Koh BH, Kim Y (2006) Intrahepatic recurrence after percutaneous radiofrequency ablation of hepatocellular carcinoma: analysis of the pattern and risk factors. Eur J Radiol 59(3):432–441. doi:10.1016/j.ejrad.2006.03.007 CrossRef Ys Kim, Rhim H, Cho OK, Koh BH, Kim Y (2006) Intrahepatic recurrence after percutaneous radiofrequency ablation of hepatocellular carcinoma: analysis of the pattern and risk factors. Eur J Radiol 59(3):432–441. doi:10.​1016/​j.​ejrad.​2006.​03.​007 CrossRef
20.
Zurück zum Zitat Koda M, Tokunaga S, Miyoshi K, Kishina M, Fujise Y, Kato J, Matono T, Okamoto K, Murawaki Y, Kakite S (2012) Assessment of ablative margin by unenhanced magnetic resonance imaging after radiofrequency ablation for hepatocellular carcinoma. Eur J Radiol 81(10):2730–2736. doi:10.1016/j.ejrad.2011.11.013 CrossRefPubMed Koda M, Tokunaga S, Miyoshi K, Kishina M, Fujise Y, Kato J, Matono T, Okamoto K, Murawaki Y, Kakite S (2012) Assessment of ablative margin by unenhanced magnetic resonance imaging after radiofrequency ablation for hepatocellular carcinoma. Eur J Radiol 81(10):2730–2736. doi:10.​1016/​j.​ejrad.​2011.​11.​013 CrossRefPubMed
21.
Zurück zum Zitat Komorizono Y, Oketani M, Sako K, Yamasaki N, Shibatou T, Maeda M, Kohara K, Shigenobu S, Ishibashi K, Arima T (2003) Risk factors for local recurrence of small hepatocellular carcinoma tumors after a single session, single application of percutaneous radiofrequency ablation. Cancer 97(5):1253–1262. doi:10.1002/cncr.11168 CrossRefPubMed Komorizono Y, Oketani M, Sako K, Yamasaki N, Shibatou T, Maeda M, Kohara K, Shigenobu S, Ishibashi K, Arima T (2003) Risk factors for local recurrence of small hepatocellular carcinoma tumors after a single session, single application of percutaneous radiofrequency ablation. Cancer 97(5):1253–1262. doi:10.​1002/​cncr.​11168 CrossRefPubMed
23.
Zurück zum Zitat Liu CH, Arellano RS, Uppot RN, Samir AE, Da Gervais, Mueller PR (2010) Radiofrequency ablation of hepatic tumours: effect of post-ablation margin on local tumour progression. Eur Radiol 20(4):877–885. doi:10.1007/s00330-009-1610-4 CrossRefPubMed Liu CH, Arellano RS, Uppot RN, Samir AE, Da Gervais, Mueller PR (2010) Radiofrequency ablation of hepatic tumours: effect of post-ablation margin on local tumour progression. Eur Radiol 20(4):877–885. doi:10.​1007/​s00330-009-1610-4 CrossRefPubMed
26.
Zurück zum Zitat Machi J, Uchida S, Sumida K, Limm WM, Hundahl SA, Oishi AJ, Furumoto NL, Oishi RH (2001) Ultrasound-guided radiofrequency thermal ablation of liver tumors: percutaneous, laparoscopic, and open surgical approaches. J Gastrointest Surg 5(5):477–489CrossRefPubMed Machi J, Uchida S, Sumida K, Limm WM, Hundahl SA, Oishi AJ, Furumoto NL, Oishi RH (2001) Ultrasound-guided radiofrequency thermal ablation of liver tumors: percutaneous, laparoscopic, and open surgical approaches. J Gastrointest Surg 5(5):477–489CrossRefPubMed
28.
Zurück zum Zitat Maurer C, Raghavan V (2003) A linear time algorithm for computing exact Euclidean distance transforms of binary images in arbitrary dimensions. IEEE Trans Pattern Anal Mach Intell 25(2):265–270. doi:10.1109/TPAMI.2003.1177156 CrossRef Maurer C, Raghavan V (2003) A linear time algorithm for computing exact Euclidean distance transforms of binary images in arbitrary dimensions. IEEE Trans Pattern Anal Mach Intell 25(2):265–270. doi:10.​1109/​TPAMI.​2003.​1177156 CrossRef
29.
Zurück zum Zitat Mori K, Fukuda K, Asaoka H, Ueda T, Kunimatsu A, Okamoto Y, Nasu K, Fukunaga K, Morishita Y, Minami M (2009) Radiofrequency ablation of the liver: determination of ablative margin at MR imaging with impaired clearance of ferucarbotran-feasibility study. Radiology 251(2):557–565. doi:10.1148/radiol.2512081161 CrossRefPubMed Mori K, Fukuda K, Asaoka H, Ueda T, Kunimatsu A, Okamoto Y, Nasu K, Fukunaga K, Morishita Y, Minami M (2009) Radiofrequency ablation of the liver: determination of ablative margin at MR imaging with impaired clearance of ferucarbotran-feasibility study. Radiology 251(2):557–565. doi:10.​1148/​radiol.​2512081161 CrossRefPubMed
30.
Zurück zum Zitat Morikawa S, Inubushi T, Kurumi Y, Naka S, Sato K, Demura K, Tani T, Haque HA, Tokuda J, Hata N (2003) Advanced computer assistance for magnetic resonance-guided microwave thermocoagulation of liver tumors. Acad Radiol 10(12):1442–1449. doi:10.1016/S1076-6332(03)00508-7 CrossRefPubMed Morikawa S, Inubushi T, Kurumi Y, Naka S, Sato K, Demura K, Tani T, Haque HA, Tokuda J, Hata N (2003) Advanced computer assistance for magnetic resonance-guided microwave thermocoagulation of liver tumors. Acad Radiol 10(12):1442–1449. doi:10.​1016/​S1076-6332(03)00508-7 CrossRefPubMed
32.
Zurück zum Zitat Nakazawa T, Kokubu S, Shibuya A, Ono K, Watanabe M, Hidaka H, Tsuchihashi T, Saigenji K (2007) Radiofrequency ablation of hepatocellular carcinoma: correlation between local tumor progression after ablation and ablative margin. Am J Roentgenol 188(2):480–488. doi:10.2214/AJR.05.2079 CrossRef Nakazawa T, Kokubu S, Shibuya A, Ono K, Watanabe M, Hidaka H, Tsuchihashi T, Saigenji K (2007) Radiofrequency ablation of hepatocellular carcinoma: correlation between local tumor progression after ablation and ablative margin. Am J Roentgenol 188(2):480–488. doi:10.​2214/​AJR.​05.​2079 CrossRef
33.
Zurück zum Zitat Ng KK, Poon RT, Lo CM, Yuen J, Tso WK, Fan ST (2008) Analysis of recurrence pattern and its influence on survival outcome after radiofrequency ablation of hepatocellular carcinoma. J Gastrointest Surg 12(1):183–191. doi:10.1007/s11605-007-0276-y CrossRefPubMed Ng KK, Poon RT, Lo CM, Yuen J, Tso WK, Fan ST (2008) Analysis of recurrence pattern and its influence on survival outcome after radiofrequency ablation of hepatocellular carcinoma. J Gastrointest Surg 12(1):183–191. doi:10.​1007/​s11605-007-0276-y CrossRefPubMed
34.
35.
Zurück zum Zitat Niculescu G, Foran DJ, Nosher J (2007) Non-rigid registration of the liver in consecutive CT studies for assessment of tumor response to radiofrequency ablation. In: 29th annual international conference of the IEEE engineering in medicine and biology society, EMBS 2007, vol 2007, pp 856–859. doi:10.1109/IEMBS.2007.4352425 Niculescu G, Foran DJ, Nosher J (2007) Non-rigid registration of the liver in consecutive CT studies for assessment of tumor response to radiofrequency ablation. In: 29th annual international conference of the IEEE engineering in medicine and biology society, EMBS 2007, vol 2007, pp 856–859. doi:10.​1109/​IEMBS.​2007.​4352425
36.
Zurück zum Zitat Oguro S, Tokuda J, Elhawary H, Haker S, Kikinis R, Tempany CMC, Hata N (2009) MRI signal intensity based B-spline nonrigid registration for pre- and intraoperative imaging during prostate brachytherapy. J Magn Reson Imaging 30(5):1052–1058. doi:10.1002/jmri.21955 CrossRefPubMedPubMedCentral Oguro S, Tokuda J, Elhawary H, Haker S, Kikinis R, Tempany CMC, Hata N (2009) MRI signal intensity based B-spline nonrigid registration for pre- and intraoperative imaging during prostate brachytherapy. J Magn Reson Imaging 30(5):1052–1058. doi:10.​1002/​jmri.​21955 CrossRefPubMedPubMedCentral
37.
Zurück zum Zitat Oguro S, Tuncali K, Elhawary H, Morrison PR, Hata N, Silverman SG (2011) Image registration of pre-procedural MRI and intra-procedural CT images to aid CT-guided percutaneous cryoablation of renal tumors. Int J Comput Assist Radiol Surg 6(1):111–117. doi:10.1007/s11548-010-0485-9 CrossRefPubMedPubMedCentral Oguro S, Tuncali K, Elhawary H, Morrison PR, Hata N, Silverman SG (2011) Image registration of pre-procedural MRI and intra-procedural CT images to aid CT-guided percutaneous cryoablation of renal tumors. Int J Comput Assist Radiol Surg 6(1):111–117. doi:10.​1007/​s11548-010-0485-9 CrossRefPubMedPubMedCentral
38.
40.
Zurück zum Zitat Rossi S, Di Stasi M, Buscarini E, Quaretti P, Garbagnati F, Squassante L, Paties CT, Silverman DE, Buscarini L (1996) Percutaneous RF interstitial thermal ablation in the treatment of hepatic cancer. Am J Roentgenol 167(3):759–768. doi:10.2214/ajr.167.3.8751696 CrossRef Rossi S, Di Stasi M, Buscarini E, Quaretti P, Garbagnati F, Squassante L, Paties CT, Silverman DE, Buscarini L (1996) Percutaneous RF interstitial thermal ablation in the treatment of hepatic cancer. Am J Roentgenol 167(3):759–768. doi:10.​2214/​ajr.​167.​3.​8751696 CrossRef
42.
Zurück zum Zitat Rozenblum N, Zeira E, Bulvik B, Gourevitch S, Yotvat H, Galun E, Goldberg SN (2015) Radiofrequency ablation: inflammatory changes in the periablative zone can induce global organ effects, including liver regeneration. Radiology 276(2):416–425. doi:10.1148/radiol.15141918 Rozenblum N, Zeira E, Bulvik B, Gourevitch S, Yotvat H, Galun E, Goldberg SN (2015) Radiofrequency ablation: inflammatory changes in the periablative zone can induce global organ effects, including liver regeneration. Radiology 276(2):416–425. doi:10.​1148/​radiol.​15141918
43.
Zurück zum Zitat Shibata T, Iimuro Y, Yamamoto Y, Maetani Y, Ametani F, Itoh K, Konishi J (2002) Small hepatocellular carcinoma: comparison of radio-frequency ablation and percutaneous microwave coagulation therapy. Radiology 223(2):331–337. doi:10.1148/radiol.2232010775 CrossRefPubMed Shibata T, Iimuro Y, Yamamoto Y, Maetani Y, Ametani F, Itoh K, Konishi J (2002) Small hepatocellular carcinoma: comparison of radio-frequency ablation and percutaneous microwave coagulation therapy. Radiology 223(2):331–337. doi:10.​1148/​radiol.​2232010775 CrossRefPubMed
44.
Zurück zum Zitat Shyn PB, Mauri G, Alencar RO, Tatli S, Shah SH, Morrison PR, Catalano PJ, Silverman SG (2014) Percutaneous imaging-guided cryoablation of liver tumors: predicting local progression on 24-hour MRI. Am J Roentgenol 203(2):W181–W191. doi:10.2214/AJR.13.10747 CrossRef Shyn PB, Mauri G, Alencar RO, Tatli S, Shah SH, Morrison PR, Catalano PJ, Silverman SG (2014) Percutaneous imaging-guided cryoablation of liver tumors: predicting local progression on 24-hour MRI. Am J Roentgenol 203(2):W181–W191. doi:10.​2214/​AJR.​13.​10747 CrossRef
45.
Zurück zum Zitat Silverman SG, Sun MRM, Tuncali K, Morrison PR, VanSonnenberg E, Shankar S, Zou KH, Warfield SK (2004) Three-dimensional assessment of MRI-guided percutaneous cryotherapy of liver metastases. Am J Roentgenol 183(3):707–712. doi:10.2214/ajr.183.3.1830707 CrossRef Silverman SG, Sun MRM, Tuncali K, Morrison PR, VanSonnenberg E, Shankar S, Zou KH, Warfield SK (2004) Three-dimensional assessment of MRI-guided percutaneous cryotherapy of liver metastases. Am J Roentgenol 183(3):707–712. doi:10.​2214/​ajr.​183.​3.​1830707 CrossRef
47.
Zurück zum Zitat Stewart BW, Wild CP (2014) World Cancer Report 2014. International Agency for Research on Cancer, WHO, Geneva Stewart BW, Wild CP (2014) World Cancer Report 2014. International Agency for Research on Cancer, WHO, Geneva
48.
Zurück zum Zitat Tateishi R, Shiina S, Teratani T, Obi S, Sato S, Koike Y, Fujishima T, Yoshida H, Kawabe T, Omata M (2005) Percutaneous radiofrequency ablation for hepatocellular carcinoma: an analysis of 1000 cases. Cancer 103(6):1201–1209. doi:10.1002/cncr.20892 CrossRefPubMed Tateishi R, Shiina S, Teratani T, Obi S, Sato S, Koike Y, Fujishima T, Yoshida H, Kawabe T, Omata M (2005) Percutaneous radiofrequency ablation for hepatocellular carcinoma: an analysis of 1000 cases. Cancer 103(6):1201–1209. doi:10.​1002/​cncr.​20892 CrossRefPubMed
50.
Zurück zum Zitat Wilson DL, Carrillo A, Zheng L, Genc A, Duerk JL, Lewin JS (1998) Evaluation of 3D image registration as applied to MR-guided thermal treatment of liver cancer. J Magn Reson Imaging 8(1):77–84CrossRefPubMed Wilson DL, Carrillo A, Zheng L, Genc A, Duerk JL, Lewin JS (1998) Evaluation of 3D image registration as applied to MR-guided thermal treatment of liver cancer. J Magn Reson Imaging 8(1):77–84CrossRefPubMed
51.
Zurück zum Zitat Wood TF, Rose DM, Chung M, Allegra DP, Foshag LJ, Bilchik aJ (2000) Radiofrequency ablation of 231 unresectable hepatic tumors: indications, limitations, and complications. Ann Surg Oncol 7(8):593–600CrossRefPubMed Wood TF, Rose DM, Chung M, Allegra DP, Foshag LJ, Bilchik aJ (2000) Radiofrequency ablation of 231 unresectable hepatic tumors: indications, limitations, and complications. Ann Surg Oncol 7(8):593–600CrossRefPubMed
Metadaten
Titel
Three-dimensional quantitative assessment of ablation margins based on registration of pre- and post-procedural MRI and distance map
verfasst von
Soichiro Tani
Servet Tatli
Nobuhiko Hata
Xavier Garcia-Rojas
Olutayo I. Olubiyi
Stuart G. Silverman
Junichi Tokuda
Publikationsdatum
01.06.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 6/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-016-1398-z

Weitere Artikel der Ausgabe 6/2016

International Journal of Computer Assisted Radiology and Surgery 6/2016 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.