Skip to main content
Erschienen in: Journal of Nuclear Cardiology 6/2010

01.12.2010 | Original Article

Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera

verfasst von: W. Lane Duvall, MD, Lori B. Croft, MD, Tapan Godiwala, MD, Eric Ginsberg, MD, Titus George, CNMT, RT(N), Milena J. Henzlova, MD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 6/2010

Einloggen, um Zugang zu erhalten

Abstract

Background

Cardiac SPECT imaging needs to become shorter and use lower radiation doses to compete with other available noninvasive imaging modalities. Recently introduced cadmium zinc telluride (CZT) SPECT cameras have the potential to achieve both goals, but clinical experience is so far limited.

Methods

Images of all patients undergoing a stress MPI over a 4-month period using a CZT camera (Discovery NM 530c) were reviewed. Patients were divided into three groups based on imaging protocols: low-dose stress-only, high-dose stress-only, and standard dose rest-stress. Low-dose stress-only patients were matched by gender, stressor, and BMI to high-dose stress-only and rest-stress subjects. Stress image quality was graded on a four-point scale by readers blinded to the imaging protocol. Demographics, tracer dose, stress imaging time, and total counts were recorded.

Results

Of 717 patients imaged, the mean age was 64.0 years, 50.5% were female, 58.9% underwent exercise stress, and the average BMI was 27.9 kg/m2. A total of 103 low-dose stress-only patients were matched to controls. Imaging for 5 minutes in low-dose stress-only patients and for 3 minutes in high-dose stress-only and rest-stress patients, resulted in a similar number of total counts. This produced similar image quality in the three groups with a 57% isotope dose reduction in the low-dose stress-only compared to the high-dose stress-only group.

Conclusion

New SPECT CZT camera technology allows significantly reduced radiation exposure and acquisition time without loss of image quality.
Literatur
1.
Zurück zum Zitat Einstein AJ, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ. Radiation dose to patients from cardiac diagnostic imaging. Circulation 2007;116:1290-305.CrossRefPubMed Einstein AJ, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ. Radiation dose to patients from cardiac diagnostic imaging. Circulation 2007;116:1290-305.CrossRefPubMed
2.
Zurück zum Zitat Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 2009;361:849-57.CrossRefPubMed Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 2009;361:849-57.CrossRefPubMed
3.
Zurück zum Zitat Slomka PJ, Patton JA, Berman DS, Germano G. Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 2009;16:255-76.CrossRefPubMed Slomka PJ, Patton JA, Berman DS, Germano G. Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 2009;16:255-76.CrossRefPubMed
4.
Zurück zum Zitat Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Berman DS. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 2008;1:156-63.CrossRefPubMed Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Berman DS. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 2008;1:156-63.CrossRefPubMed
5.
Zurück zum Zitat Berman DS, Kang X, Tamarappoo B, Wolak A, Hayes SW, Nakazato R, et al. Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2009;2:273-82.CrossRefPubMed Berman DS, Kang X, Tamarappoo B, Wolak A, Hayes SW, Nakazato R, et al. Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2009;2:273-82.CrossRefPubMed
6.
Zurück zum Zitat Esteves FP, Raggi P, Folks RD, Keidar Z, Askew JW, Rispler S, et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: Multicenter comparison with standard dual detector cameras. J Nucl Cardiol 2009;16:927-34.CrossRefPubMed Esteves FP, Raggi P, Folks RD, Keidar Z, Askew JW, Rispler S, et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: Multicenter comparison with standard dual detector cameras. J Nucl Cardiol 2009;16:927-34.CrossRefPubMed
7.
Zurück zum Zitat Henzlova MJ, Cerqueira MD, Hansen CL, Taillefer R, Yao SS. ASNC announcement. J Nucl Cardiol 2009;16:331.CrossRef Henzlova MJ, Cerqueira MD, Hansen CL, Taillefer R, Yao SS. ASNC announcement. J Nucl Cardiol 2009;16:331.CrossRef
8.
Zurück zum Zitat Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.CrossRefPubMed Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.CrossRefPubMed
9.
Zurück zum Zitat Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, et al. Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: A basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1995;26:639-47.CrossRefPubMed Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, et al. Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: A basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1995;26:639-47.CrossRefPubMed
10.
Zurück zum Zitat Hachamovitch R, Berman DS, Shaw LJ, Kiat H, Cohen I, Cabico JA, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction. Circulation 1998;97:535-43.PubMed Hachamovitch R, Berman DS, Shaw LJ, Kiat H, Cohen I, Cabico JA, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction. Circulation 1998;97:535-43.PubMed
11.
Zurück zum Zitat Duvall WL, Wijetunga M, Klein T, Hingorani R, Henzlova M. The prognosis of normal stress-only SPECT myocardial perfusion imaging studies (abstr). J Am Coll Cardiol 2009;53:287A. Duvall WL, Wijetunga M, Klein T, Hingorani R, Henzlova M. The prognosis of normal stress-only SPECT myocardial perfusion imaging studies (abstr). J Am Coll Cardiol 2009;53:287A.
12.
Zurück zum Zitat Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress-only versus standard stress/rest myocardial perfusion imaging similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55(3):220-9.CrossRef Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress-only versus standard stress/rest myocardial perfusion imaging similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55(3):220-9.CrossRef
13.
Zurück zum Zitat ICRP. ICRP Publication 103: The 2007 recommendations of the International Commission on Radiological Protection. Ann ICRP 2007;37:1-332. ICRP. ICRP Publication 103: The 2007 recommendations of the International Commission on Radiological Protection. Ann ICRP 2007;37:1-332.
14.
Zurück zum Zitat Buechel RR, Herzog BA, Husmann L, Burger IA, Pazhenkottil AP, Treyer V, et al. Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: First clinical validation. Eur J Nucl Med Mol Imaging 2010;37:773-8.CrossRefPubMed Buechel RR, Herzog BA, Husmann L, Burger IA, Pazhenkottil AP, Treyer V, et al. Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: First clinical validation. Eur J Nucl Med Mol Imaging 2010;37:773-8.CrossRefPubMed
15.
Zurück zum Zitat Herzog BA, Buechel RR, Katz R, Brueckner M, Husmann L, Burger IA, et al. Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: Optimized protocol for scan time reduction. J Nucl Med 2010;51:46-51.CrossRefPubMed Herzog BA, Buechel RR, Katz R, Brueckner M, Husmann L, Burger IA, et al. Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: Optimized protocol for scan time reduction. J Nucl Med 2010;51:46-51.CrossRefPubMed
Metadaten
Titel
Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera
verfasst von
W. Lane Duvall, MD
Lori B. Croft, MD
Tapan Godiwala, MD
Eric Ginsberg, MD
Titus George, CNMT, RT(N)
Milena J. Henzlova, MD
Publikationsdatum
01.12.2010
Verlag
Springer-Verlag
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 6/2010
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-010-9215-5

Weitere Artikel der Ausgabe 6/2010

Journal of Nuclear Cardiology 6/2010 Zur Ausgabe

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Komplette Revaskularisation bei Infarkt: Neue Studie setzt ein Fragezeichen

24.04.2024 ACC 2024 Nachrichten

Eine FFR-gesteuerte komplette Revaskularisation war in einer Studie bei Patienten mit akutem Myokardinfarkt und koronarer Mehrgefäßerkrankung klinisch nicht wirksamer als eine alleinige Revaskularisation der Infarktarterie.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.