Erschienen in: Journal of Nuclear Cardiology 5/2010

01.10.2010 | ASNC Imaging Guidelines for Nuclear Cardiology Procedures

Single photon-emission computed tomography

verfasst von: Thomas A. Holly, MD, Brian G. Abbott, MD, Mouaz Al-Mallah, MD, Dennis A. Calnon, MD, Mylan C. Cohen, MD, MPH, Frank P. DiFilippo, PhD, Edward P. Ficaro, PhD, Michael R. Freeman, MD, Robert C. Hendel, MD, Diwakar Jain, MD, Scott M. Leonard, MS, CNMT, RT(N), Kenneth J. Nichols, PhD, Donna M. Polk, MD, MPH, Prem Soman, MD, PhD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 5/2010

Einloggen, um Zugang zu erhalten

Excerpt

The current document is an update of an earlier version of single photon emission tomography (SPECT) guidelines that was developed by the American Society of Nuclear Cardiology. Although that document was only published a few years ago, there have been significant advances in camera technology, imaging protocols, and reconstruction algorithms that prompted the need for a revised document. This publication is designed to provide imaging guidelines for physicians and technologists who are qualified to practice nuclear cardiology. While the information supplied in this document has been carefully reviewed by experts in the field, the document should not be considered medical advice or a professional service. We are cognizant that SPECT technology is evolving rapidly and that these recommendations may need further revision in the near future. Hence, the imaging guidelines described in this publication should not be used in clinical studies until they have been reviewed and approved by qualified physicians and technologists from their own particular institutions. …
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Kennedy JA, Yosilevsky G, Przewloka K, Israel O, Frenkel A. 3D spatial resolution map and sensitivity characterization of a dedicated cardiac CZT SPECT camera [abstract]. J Nucl Med 2009;50:107.CrossRef Kennedy JA, Yosilevsky G, Przewloka K, Israel O, Frenkel A. 3D spatial resolution map and sensitivity characterization of a dedicated cardiac CZT SPECT camera [abstract]. J Nucl Med 2009;50:107.CrossRef
2.
Zurück zum Zitat Garcia EV, Tsukerman L, Keidar Z. A new solid state, ultra fast cardiac multi-detector SPECT system [abstract]. J Nucl Cardiol 2008;15:S3.CrossRef Garcia EV, Tsukerman L, Keidar Z. A new solid state, ultra fast cardiac multi-detector SPECT system [abstract]. J Nucl Cardiol 2008;15:S3.CrossRef
3.
Zurück zum Zitat Gambhir SS, Berman DS, Ziffer JA, et al. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J Nucl Med 2009;50:635-43.CrossRefPubMed Gambhir SS, Berman DS, Ziffer JA, et al. A novel high-sensitivity rapid-acquisition single-photon cardiac imaging camera. J Nucl Med 2009;50:635-43.CrossRefPubMed
4.
Zurück zum Zitat Bushberg JT, Seibert JA, Leidholt EM, Boone JM. The essential physics of medical imaging. Baltimore, MD: Williams & Wilkins; 1994. Bushberg JT, Seibert JA, Leidholt EM, Boone JM. The essential physics of medical imaging. Baltimore, MD: Williams & Wilkins; 1994.
5.
Zurück zum Zitat Cherry SR, Sorenson JA, Phelps ME. Physics in nuclear medicine. 3rd ed. Philadelphia, PA: Elsevier Science; 2003. Cherry SR, Sorenson JA, Phelps ME. Physics in nuclear medicine. 3rd ed. Philadelphia, PA: Elsevier Science; 2003.
6.
Zurück zum Zitat Cullom SJ. Principles of cardiac SPECT imaging. In: DePuey EG, Berman DS, Garcia EV, editors. Cardiac SPECT. 2nd ed. Philadelphia, PA: Lippincott, Williams & Wilkins; 2001. p. 3-16. Cullom SJ. Principles of cardiac SPECT imaging. In: DePuey EG, Berman DS, Garcia EV, editors. Cardiac SPECT. 2nd ed. Philadelphia, PA: Lippincott, Williams & Wilkins; 2001. p. 3-16.
7.
Zurück zum Zitat Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1982;1:113-22.CrossRefPubMed Shepp LA, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1982;1:113-22.CrossRefPubMed
8.
Zurück zum Zitat Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994;13:601-9.CrossRefPubMed Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994;13:601-9.CrossRefPubMed
9.
Zurück zum Zitat Bowsher JE, Floyd CE. Treatment of Compton scattering in maximum likelihood, expectation-maximization reconstructions of SPECT images. J Nucl Med 1991;32:1285-91.PubMed Bowsher JE, Floyd CE. Treatment of Compton scattering in maximum likelihood, expectation-maximization reconstructions of SPECT images. J Nucl Med 1991;32:1285-91.PubMed
10.
Zurück zum Zitat Xaio J, de Wit TC, Staelen SG, Beekman FJ. Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT. J Nucl Med 2006;47:1662-9. Xaio J, de Wit TC, Staelen SG, Beekman FJ. Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT. J Nucl Med 2006;47:1662-9.
11.
Zurück zum Zitat Daou D, Pointurier I, Coaguila C, et al. Performance of OSEM and depth-dependent resolution recovery algorithms for the evaluation of global left ventricular function in 201Tl gated myocardial perfusion SPECT. J Nucl Med 2003;44:155-62.PubMed Daou D, Pointurier I, Coaguila C, et al. Performance of OSEM and depth-dependent resolution recovery algorithms for the evaluation of global left ventricular function in 201Tl gated myocardial perfusion SPECT. J Nucl Med 2003;44:155-62.PubMed
12.
13.
Zurück zum Zitat O’Connor MK. Instrument- and computer-related problems and artifacts in nuclear medicine. Semin Nucl Med 1996;26:256-77.CrossRefPubMed O’Connor MK. Instrument- and computer-related problems and artifacts in nuclear medicine. Semin Nucl Med 1996;26:256-77.CrossRefPubMed
14.
Zurück zum Zitat Lau YH, Hutton BF, Beekman FJ. Choice of collimator for cardiac SPECT when resolution compensation is included in iterative reconstruction. Eur J Nucl Med 2001;28:39-47.CrossRefPubMed Lau YH, Hutton BF, Beekman FJ. Choice of collimator for cardiac SPECT when resolution compensation is included in iterative reconstruction. Eur J Nucl Med 2001;28:39-47.CrossRefPubMed
15.
Zurück zum Zitat Devito RP, Haines EJ, Domnanovitch JR, inventors. Mosaic Imaging Technology, Inc. Non-orbiting tomographic imaging system. US Patent 6242743, June 5, 2001. Devito RP, Haines EJ, Domnanovitch JR, inventors. Mosaic Imaging Technology, Inc. Non-orbiting tomographic imaging system. US Patent 6242743, June 5, 2001.
16.
Zurück zum Zitat Sharir T, Ben-Haim S, Merzon K, et al. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. J Am Coll Cardiol Imaging 2008;1:156-63. Sharir T, Ben-Haim S, Merzon K, et al. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. J Am Coll Cardiol Imaging 2008;1:156-63.
17.
Zurück zum Zitat Hawman PC, Haines EJ. The cardiofocal collimator: A variable-focus collimator for cardiac SPECT. Phys Med Biol 1994;39:439-50.CrossRefPubMed Hawman PC, Haines EJ. The cardiofocal collimator: A variable-focus collimator for cardiac SPECT. Phys Med Biol 1994;39:439-50.CrossRefPubMed
18.
Zurück zum Zitat Hasegawa B, Kirch D, Stern D, et al. Single-photon emission tomography with a 12-pinhole collimator. J Nucl Med 1982;23:606-12.PubMed Hasegawa B, Kirch D, Stern D, et al. Single-photon emission tomography with a 12-pinhole collimator. J Nucl Med 1982;23:606-12.PubMed
19.
Zurück zum Zitat Steele PP, Kirch DL, Koss JE. Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease. J Nucl Med 2008;49:1080-9.CrossRefPubMed Steele PP, Kirch DL, Koss JE. Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease. J Nucl Med 2008;49:1080-9.CrossRefPubMed
20.
Zurück zum Zitat Herzog BA, Beuchel RR, Katz R, et al. Nuclear myocardial perfusion imaging with cadmium-zinc-telluride detector technique: Optimized protocol for scan time reduction. J Nucl Med 2010;51:46-51.CrossRefPubMed Herzog BA, Beuchel RR, Katz R, et al. Nuclear myocardial perfusion imaging with cadmium-zinc-telluride detector technique: Optimized protocol for scan time reduction. J Nucl Med 2010;51:46-51.CrossRefPubMed
21.
Zurück zum Zitat Shin JH, Pokharna HK, Williams KA, Mehta R, Ward RP. SPECT myocardial perfusion imaging with prone-only acquisitions: Correlation with coronary angiography. J Nucl Cardiol 2009;16:590-6.CrossRefPubMed Shin JH, Pokharna HK, Williams KA, Mehta R, Ward RP. SPECT myocardial perfusion imaging with prone-only acquisitions: Correlation with coronary angiography. J Nucl Cardiol 2009;16:590-6.CrossRefPubMed
22.
Zurück zum Zitat Erlandsson K, Kacperski K, van Gramberg D, Hutton BF. Performance evaluation of D-SPECT: A novel SPECT system for nuclear cardiology. Phys Med Biol 2009;54:2635-49.CrossRefPubMed Erlandsson K, Kacperski K, van Gramberg D, Hutton BF. Performance evaluation of D-SPECT: A novel SPECT system for nuclear cardiology. Phys Med Biol 2009;54:2635-49.CrossRefPubMed
23.
Zurück zum Zitat Nichols KG, Galt JR. Quality control for SPECT imaging. In: DePuey EG, Berman DS, Garcia EV, editors. Cardiac SPECT imaging. 2nd ed. Philadelphia, PA: Lippincott Williams & Wilkins; 2001. p. 17-40. Nichols KG, Galt JR. Quality control for SPECT imaging. In: DePuey EG, Berman DS, Garcia EV, editors. Cardiac SPECT imaging. 2nd ed. Philadelphia, PA: Lippincott Williams & Wilkins; 2001. p. 17-40.
24.
Zurück zum Zitat National Electrical Manufacturers Association. NEMA Standards Publication NU 1-2007: Performance measurements of scintillation cameras. Washington, DC: National Electrical Manufacturers Association; 2007. National Electrical Manufacturers Association. NEMA Standards Publication NU 1-2007: Performance measurements of scintillation cameras. Washington, DC: National Electrical Manufacturers Association; 2007.
25.
Zurück zum Zitat Esser PD, Graham LS. A quality control program for nuclear medicine cameras. In: Henkin RE, editor. Nuclear medicine. 2nd ed. Philadelphia, PA: Mosby; 2006. p. 246-56. Esser PD, Graham LS. A quality control program for nuclear medicine cameras. In: Henkin RE, editor. Nuclear medicine. 2nd ed. Philadelphia, PA: Mosby; 2006. p. 246-56.
26.
Zurück zum Zitat DePuey EG. How to detect and avoid myocardial perfusion SPECT artifacts. J Nucl Med 1994;35:699-702.PubMed DePuey EG. How to detect and avoid myocardial perfusion SPECT artifacts. J Nucl Med 1994;35:699-702.PubMed
27.
Zurück zum Zitat Galt JR, Faber T. Principles of single photon emission computed tomography (SPECT) imaging. In: Christian PE, Bernier DR, Langan JK, editors. Nuclear medicine and PET: Technology and techniques. St. Louis: Mosby; 2003. p. 242-84. Galt JR, Faber T. Principles of single photon emission computed tomography (SPECT) imaging. In: Christian PE, Bernier DR, Langan JK, editors. Nuclear medicine and PET: Technology and techniques. St. Louis: Mosby; 2003. p. 242-84.
28.
Zurück zum Zitat Cerqueira MD, Matsuoka D, Ritchie JL, Harp GD. The influence of collimators on SPECT center of rotation measurements: Artifact generation and acceptance testing. J Nucl Med 1988;29:1393-7.PubMed Cerqueira MD, Matsuoka D, Ritchie JL, Harp GD. The influence of collimators on SPECT center of rotation measurements: Artifact generation and acceptance testing. J Nucl Med 1988;29:1393-7.PubMed
29.
Zurück zum Zitat Hines H, Kayayan R, Colsher J, et al. National Electrical Manufacturers Association recommendation for implementing SPECT instrumentation quality control. J Nucl Med 2000;41:383-9.PubMed Hines H, Kayayan R, Colsher J, et al. National Electrical Manufacturers Association recommendation for implementing SPECT instrumentation quality control. J Nucl Med 2000;41:383-9.PubMed
30.
Zurück zum Zitat Greer KL, Jaszczak RJ, Coleman RE. An overview of a camera-based SPECT system. Med Phys 1982;9:455-63.CrossRefPubMed Greer KL, Jaszczak RJ, Coleman RE. An overview of a camera-based SPECT system. Med Phys 1982;9:455-63.CrossRefPubMed
33.
Zurück zum Zitat American Society of Nuclear Cardiology. ASNC imaging guidelines for nuclear cardiology procedures: Introduction of new technology for clinical use. J Nucl Cardiol 2009;16:166. American Society of Nuclear Cardiology. ASNC imaging guidelines for nuclear cardiology procedures: Introduction of new technology for clinical use. J Nucl Cardiol 2009;16:166.
34.
Zurück zum Zitat Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress-only versus standard stress/rest myocardial perfusion imaging: Similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55:221-30.CrossRefPubMed Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress-only versus standard stress/rest myocardial perfusion imaging: Similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55:221-30.CrossRefPubMed
35.
Zurück zum Zitat Segall GM, Davis MJ. Prone versus supine thallium myocardial SPECT: A method to decrease artifactual inferior wall defects. J Nucl Med 1989;30:548-55.PubMed Segall GM, Davis MJ. Prone versus supine thallium myocardial SPECT: A method to decrease artifactual inferior wall defects. J Nucl Med 1989;30:548-55.PubMed
36.
Zurück zum Zitat Kiat H, Van Train KF, Friedman JD, Germano G, Silagan G, Wang FP, et al. Quantitative stress-redistribution thallium-201 SPECT using prone imaging: Methodologic development and validation. J Nucl Med 1992;33:1509-15.PubMed Kiat H, Van Train KF, Friedman JD, Germano G, Silagan G, Wang FP, et al. Quantitative stress-redistribution thallium-201 SPECT using prone imaging: Methodologic development and validation. J Nucl Med 1992;33:1509-15.PubMed
37.
Zurück zum Zitat Esquerre JP, Coca FJ, Martinez SJ, Guiraud RF. Prone decubitus: A solution to inferior wall attenuation in thallium-201 myocardial tomography. J Nucl Med 1989;30:398-401.PubMed Esquerre JP, Coca FJ, Martinez SJ, Guiraud RF. Prone decubitus: A solution to inferior wall attenuation in thallium-201 myocardial tomography. J Nucl Med 1989;30:398-401.PubMed
38.
Zurück zum Zitat Nishina H, Slomka PJ, Abidov A, et al. Combined supine and prone quantitative myocardial perfusion SPECT: Method development and clinical validation in patients with no known coronary artery disease. J Nucl Med 2006;47:51-8.PubMed Nishina H, Slomka PJ, Abidov A, et al. Combined supine and prone quantitative myocardial perfusion SPECT: Method development and clinical validation in patients with no known coronary artery disease. J Nucl Med 2006;47:51-8.PubMed
39.
Zurück zum Zitat Slomka PJ, Nishina H, Abidov A, et al. Combined quantitative supine-prone myocardial perfusion SPECT improves detection of coronary artery disease and normalcy rates in women. J Nucl Cardiol 2007;14:44-52.CrossRefPubMed Slomka PJ, Nishina H, Abidov A, et al. Combined quantitative supine-prone myocardial perfusion SPECT improves detection of coronary artery disease and normalcy rates in women. J Nucl Cardiol 2007;14:44-52.CrossRefPubMed
40.
Zurück zum Zitat Friedman J, Van Train K, Maddahi J, Rozanski A, Prigent F, Bietendorf J, et al. “Upward creep” of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT. J Nucl Med 1989;30:1718-22.PubMed Friedman J, Van Train K, Maddahi J, Rozanski A, Prigent F, Bietendorf J, et al. “Upward creep” of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT. J Nucl Med 1989;30:1718-22.PubMed
41.
Zurück zum Zitat Bateman TM, Berman DS, Heller GV, Brown KA, Cerqueira MD, Verani MS, et al. American Society of Nuclear Cardiology position statement on electrocardiographic gating of myocardial perfusion SPECT scintigrams. J Nucl Cardiol 1999;6:470-1.CrossRefPubMed Bateman TM, Berman DS, Heller GV, Brown KA, Cerqueira MD, Verani MS, et al. American Society of Nuclear Cardiology position statement on electrocardiographic gating of myocardial perfusion SPECT scintigrams. J Nucl Cardiol 1999;6:470-1.CrossRefPubMed
42.
Zurück zum Zitat Cullom SJ, Case JA, Bateman TM. Electrocardiographically gated myocardial perfusion SPECT: Technical principles and quality control considerations. J Nucl Cardiol 1998;5:418-25.CrossRefPubMed Cullom SJ, Case JA, Bateman TM. Electrocardiographically gated myocardial perfusion SPECT: Technical principles and quality control considerations. J Nucl Cardiol 1998;5:418-25.CrossRefPubMed
43.
Zurück zum Zitat DePuey EG, Nichols K, Dobrinsky C. Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT. J Nucl Med 1993;34:1871-6.PubMed DePuey EG, Nichols K, Dobrinsky C. Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT. J Nucl Med 1993;34:1871-6.PubMed
44.
Zurück zum Zitat Smanio PE, Watson DD, Segalla DL, Vinson EL, Smith WH, Beller GA. Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging. J Am Coll Cardiol 1997;30:1687-92.CrossRefPubMed Smanio PE, Watson DD, Segalla DL, Vinson EL, Smith WH, Beller GA. Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging. J Am Coll Cardiol 1997;30:1687-92.CrossRefPubMed
45.
Zurück zum Zitat He ZX, Cwajg E, Preslar JS, Mahmarian JJ, Verani MS. Ejection fraction determined by gated myocardial perfusion SPECT with Tl-201 and Tc-99m sestamibi: Comparison with first-pass radionuclide angiography. J Nucl Cardiol 1999;4:412-7. He ZX, Cwajg E, Preslar JS, Mahmarian JJ, Verani MS. Ejection fraction determined by gated myocardial perfusion SPECT with Tl-201 and Tc-99m sestamibi: Comparison with first-pass radionuclide angiography. J Nucl Cardiol 1999;4:412-7.
46.
Zurück zum Zitat Hansen C. Digital image processing for clinicians, part II: Filtering. J Nucl Cardiol 2002;9:429-37.CrossRefPubMed Hansen C. Digital image processing for clinicians, part II: Filtering. J Nucl Cardiol 2002;9:429-37.CrossRefPubMed
47.
Zurück zum Zitat Hansen CL, Kramer M, Rastogi A. Lower accuracy of Tl-201 SPECT in women is not improved by size-based normal databases or Wiener filtering. J Nucl Cardiol 1999;6:177-82.CrossRefPubMed Hansen CL, Kramer M, Rastogi A. Lower accuracy of Tl-201 SPECT in women is not improved by size-based normal databases or Wiener filtering. J Nucl Cardiol 1999;6:177-82.CrossRefPubMed
48.
Zurück zum Zitat King MA, Glick SJ, Penney BC, Schwinger RB, Doherty PW. Interactive visual optimization of SPECT prereconstruction filtering. J Nucl Med 1987;28:1192-8.PubMed King MA, Glick SJ, Penney BC, Schwinger RB, Doherty PW. Interactive visual optimization of SPECT prereconstruction filtering. J Nucl Med 1987;28:1192-8.PubMed
49.
Zurück zum Zitat Hansen C. Digital image processing for clinicians, part III: SPECT reconstruction. J Nucl Cardiol 2002;9:542-9.CrossRefPubMed Hansen C. Digital image processing for clinicians, part III: SPECT reconstruction. J Nucl Cardiol 2002;9:542-9.CrossRefPubMed
50.
Zurück zum Zitat Yester MV. SPECT image reconstruction. In: Henkin RE, editor. Nuclear medicine. 2nd ed. Philadelphia, PA: Mosby; 2006. p. 185-95. Yester MV. SPECT image reconstruction. In: Henkin RE, editor. Nuclear medicine. 2nd ed. Philadelphia, PA: Mosby; 2006. p. 185-95.
51.
Zurück zum Zitat Borges-Neto S, Pagnanelli RA, Shaw LJ, et al. Clinical results of a novel wide beam reconstruction methods for shortening scan time of Tc-99m cardiac SPECT perfusion studies. J Nucl Cardiol 2007;14:555-65.CrossRefPubMed Borges-Neto S, Pagnanelli RA, Shaw LJ, et al. Clinical results of a novel wide beam reconstruction methods for shortening scan time of Tc-99m cardiac SPECT perfusion studies. J Nucl Cardiol 2007;14:555-65.CrossRefPubMed
52.
Zurück zum Zitat DePuey EG, Gadiraju R, Clark J, et al. Ordered subset expectation maximization and wide beam reconstruction “half-time” gated myocardial perfusion SPECT functional imaging: A comparison to “full-time” filtered backprojection. J Nucl Cardiol 2008;14:547-63.CrossRef DePuey EG, Gadiraju R, Clark J, et al. Ordered subset expectation maximization and wide beam reconstruction “half-time” gated myocardial perfusion SPECT functional imaging: A comparison to “full-time” filtered backprojection. J Nucl Cardiol 2008;14:547-63.CrossRef
53.
Zurück zum Zitat DePuey EG, Bommireddipalli S, Clark J, Thompson L, Srour Y. Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: A comparison to “full-time” ordered subset expectation maximum. J Nucl Cardiol 2009;16:736-52.CrossRefPubMed DePuey EG, Bommireddipalli S, Clark J, Thompson L, Srour Y. Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: A comparison to “full-time” ordered subset expectation maximum. J Nucl Cardiol 2009;16:736-52.CrossRefPubMed
54.
Zurück zum Zitat Hansen CL. The role of the translation table in cardiac image display. J Nucl Cardiol 2006;13:571-5.CrossRefPubMed Hansen CL. The role of the translation table in cardiac image display. J Nucl Cardiol 2006;13:571-5.CrossRefPubMed
55.
Zurück zum Zitat Hansen C. Digital image processing for clinicians, Part I: Basics of image formation. J Nucl Cardiol 2002;9:343-9.CrossRefPubMed Hansen C. Digital image processing for clinicians, Part I: Basics of image formation. J Nucl Cardiol 2002;9:343-9.CrossRefPubMed
56.
Zurück zum Zitat Friedman J, Berman DS, Van Train K, Garcia EV, Bietendorf J, Prigent F, et al. Patient motion in thallium-201 myocardial SPECT imaging. An easily identified frequent source of artifactual defect. Clin Nucl Med 1988;13:321-4.CrossRefPubMed Friedman J, Berman DS, Van Train K, Garcia EV, Bietendorf J, Prigent F, et al. Patient motion in thallium-201 myocardial SPECT imaging. An easily identified frequent source of artifactual defect. Clin Nucl Med 1988;13:321-4.CrossRefPubMed
57.
Zurück zum Zitat Cooper JA, Neumann PH, McCandless BK. Effect of patient motion on tomographic myocardial perfusion imaging. J Nucl Med 1992;33:1566-71.PubMed Cooper JA, Neumann PH, McCandless BK. Effect of patient motion on tomographic myocardial perfusion imaging. J Nucl Med 1992;33:1566-71.PubMed
58.
Zurück zum Zitat Choi JY, Lee KH, Kim SJ, Kim SE, Kim BT, Lee SH, et al. Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT. J Nucl Cardiol 1998;5:395-401.CrossRefPubMed Choi JY, Lee KH, Kim SJ, Kim SE, Kim BT, Lee SH, et al. Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT. J Nucl Cardiol 1998;5:395-401.CrossRefPubMed
59.
Zurück zum Zitat Ficaro EP, Fessler JA, Shreve PD. et al. Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography. Circulation 1996;93:463-73.PubMed Ficaro EP, Fessler JA, Shreve PD. et al. Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography. Circulation 1996;93:463-73.PubMed
60.
Zurück zum Zitat Fricke H, Fricke E, Weise R, et al. A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT. Introduced by misalignment between emission scan and CT-derived attenuation maps. J Nucl Med 2004;45:1619-25.PubMed Fricke H, Fricke E, Weise R, et al. A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT. Introduced by misalignment between emission scan and CT-derived attenuation maps. J Nucl Med 2004;45:1619-25.PubMed
61.
Zurück zum Zitat Grossman GB, Garcia EV, Bateman T, et al. Quantitative Tc-99m sestamibi attenuation-corrected SPECT: Development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in obese population. J Nucl Cardiol 2004;11:263-772.CrossRefPubMed Grossman GB, Garcia EV, Bateman T, et al. Quantitative Tc-99m sestamibi attenuation-corrected SPECT: Development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in obese population. J Nucl Cardiol 2004;11:263-772.CrossRefPubMed
62.
Zurück zum Zitat Weiss AT, Berman DS, Lew AS, et al. Transient ischemic dilation of the left ventricle on stress thallium-201 scintigraphy: A marker of severe and extensive coronary artery disease. J Am Coll Cardiol 1987;9:752-9.CrossRefPubMed Weiss AT, Berman DS, Lew AS, et al. Transient ischemic dilation of the left ventricle on stress thallium-201 scintigraphy: A marker of severe and extensive coronary artery disease. J Am Coll Cardiol 1987;9:752-9.CrossRefPubMed
63.
Zurück zum Zitat McLaughlin MG, Danias PG. Transient ischemic dilation: A powerful diagnostic and prognostic finding of stress myocardial perfusion imaging. J Nucl Cardiol 2002;9:663-7.CrossRefPubMed McLaughlin MG, Danias PG. Transient ischemic dilation: A powerful diagnostic and prognostic finding of stress myocardial perfusion imaging. J Nucl Cardiol 2002;9:663-7.CrossRefPubMed
64.
Zurück zum Zitat Hansen CL, Sangrigoli R, Nkadi E, Kramer M. Comparison of pulmonary uptake with transient cavity dilation after exercise thallium-201 perfusion imaging. J Am Coll Cardiol 1999;33:1323-7.CrossRefPubMed Hansen CL, Sangrigoli R, Nkadi E, Kramer M. Comparison of pulmonary uptake with transient cavity dilation after exercise thallium-201 perfusion imaging. J Am Coll Cardiol 1999;33:1323-7.CrossRefPubMed
65.
Zurück zum Zitat Hansen CL, Cen P, Sanchez B, Robinson R. Comparison of pulmonary uptake with transient cavity dilation after dipyridamole Tl-201 perfusion imaging. J Nucl Cardiol 2002;9:47-51.CrossRefPubMed Hansen CL, Cen P, Sanchez B, Robinson R. Comparison of pulmonary uptake with transient cavity dilation after dipyridamole Tl-201 perfusion imaging. J Nucl Cardiol 2002;9:47-51.CrossRefPubMed
66.
Zurück zum Zitat Chouraqui P, Rodrigues EA, Berman DS, Maddahi J. Significance of dipyridamole-induced transient dilation of the left ventricle during thallium-201 scintigraphy in suspected coronary artery disease. Am J Cardiol 1990;66:689-94.CrossRefPubMed Chouraqui P, Rodrigues EA, Berman DS, Maddahi J. Significance of dipyridamole-induced transient dilation of the left ventricle during thallium-201 scintigraphy in suspected coronary artery disease. Am J Cardiol 1990;66:689-94.CrossRefPubMed
67.
Zurück zum Zitat Abidov A, Bax JJ, Hayes SW, et al. Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD. J Nucl Med 2004;45:1999-2007.PubMed Abidov A, Bax JJ, Hayes SW, et al. Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD. J Nucl Med 2004;45:1999-2007.PubMed
68.
Zurück zum Zitat Gill JB, Ruddy TD, Newell JB, et al. Prognostic importance of thallium uptake by the lungs during exercise in coronary artery disease. N Engl J Med 1987;317:1486-9.CrossRefPubMed Gill JB, Ruddy TD, Newell JB, et al. Prognostic importance of thallium uptake by the lungs during exercise in coronary artery disease. N Engl J Med 1987;317:1486-9.CrossRefPubMed
70.
Zurück zum Zitat Williams KA, Schneider CM. Increased stress right ventricular activity on dual isotope perfusion SPECT: A sign of multivessel and/or left main coronary artery disease. J Am Coll Cardiol 1999;34:420-7.CrossRefPubMed Williams KA, Schneider CM. Increased stress right ventricular activity on dual isotope perfusion SPECT: A sign of multivessel and/or left main coronary artery disease. J Am Coll Cardiol 1999;34:420-7.CrossRefPubMed
71.
Zurück zum Zitat Williams KA, Hill KA, Sheridan CM. Noncardiac findings on dual-isotope myocardial perfusion SPECT. J Nucl Cardiol 2003;10:395-402.CrossRefPubMed Williams KA, Hill KA, Sheridan CM. Noncardiac findings on dual-isotope myocardial perfusion SPECT. J Nucl Cardiol 2003;10:395-402.CrossRefPubMed
72.
Zurück zum Zitat Cerqueira MD, Weissman NJ, Dilsizian V, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. J Nucl Cardiol 2002;9:240-5.CrossRefPubMed Cerqueira MD, Weissman NJ, Dilsizian V, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. J Nucl Cardiol 2002;9:240-5.CrossRefPubMed
73.
Zurück zum Zitat Tilkemeier PL, Cooke CD, Ficaro EP, et al. ASNC imaging guidelines for nuclear cardiology procedures: Standardized reporting of myocardial perfusion images. J Nucl Cardiol 2009;16:165. Tilkemeier PL, Cooke CD, Ficaro EP, et al. ASNC imaging guidelines for nuclear cardiology procedures: Standardized reporting of myocardial perfusion images. J Nucl Cardiol 2009;16:165.
74.
Zurück zum Zitat Hachamovitch R, Berman DS, Shaw LJ, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction. Circulation 1998;97:535-43.PubMed Hachamovitch R, Berman DS, Shaw LJ, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction. Circulation 1998;97:535-43.PubMed
75.
Zurück zum Zitat Travin MI. The oft neglected rest study. J Nucl Cardiol 2009;15:739-42. Travin MI. The oft neglected rest study. J Nucl Cardiol 2009;15:739-42.
76.
Zurück zum Zitat Shaw LJ, Hendel RC, Heller GV, et al. Prognostic estimation of coronary artery disease risk with resting perfusion abnormalities and stress ischemia on myocardial perfusion SPECT. J Nucl Cardiol 2009;15:762-73. Shaw LJ, Hendel RC, Heller GV, et al. Prognostic estimation of coronary artery disease risk with resting perfusion abnormalities and stress ischemia on myocardial perfusion SPECT. J Nucl Cardiol 2009;15:762-73.
77.
Zurück zum Zitat Berman DS, Kang X, Van Train KF, et al. Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1998;32:1987-95.CrossRefPubMed Berman DS, Kang X, Van Train KF, et al. Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 1998;32:1987-95.CrossRefPubMed
78.
Zurück zum Zitat Leslie WB, Tully SA, Yogendran MS, et al. Prognostic value of automated quantification of 99mTc-sestamibi myocardial perfusion imaging. J Nucl Med 2005;46:204-11.PubMed Leslie WB, Tully SA, Yogendran MS, et al. Prognostic value of automated quantification of 99mTc-sestamibi myocardial perfusion imaging. J Nucl Med 2005;46:204-11.PubMed
79.
Zurück zum Zitat Berman DS, Kang X, Gransar H, et al. Quantitative assessment of myocardial perfusion abnormality on SPECT myocardial perfusion imaging is more reproducible than expert visual analysis. J Nucl Cardiol 2009;16:45-53.CrossRefPubMed Berman DS, Kang X, Gransar H, et al. Quantitative assessment of myocardial perfusion abnormality on SPECT myocardial perfusion imaging is more reproducible than expert visual analysis. J Nucl Cardiol 2009;16:45-53.CrossRefPubMed
80.
Zurück zum Zitat Iskandrian AS, Garcia EV, Faber T, Mahmarian JJ. Automated assessment of serial SPECT myocardial perfusion images. J Nucl Cardiol 2009;16:6-9.CrossRefPubMed Iskandrian AS, Garcia EV, Faber T, Mahmarian JJ. Automated assessment of serial SPECT myocardial perfusion images. J Nucl Cardiol 2009;16:6-9.CrossRefPubMed
81.
Zurück zum Zitat Mahmarian JJ, Cerqueira MD, Iskandrian AS. Regadenoson induces comparable left ventricular perfusion defects as adenosine: A quantitative analysis from the ADVANCE MPI 2 Trial. J Am Coll Cardiol Img 2009;2:959-68. Mahmarian JJ, Cerqueira MD, Iskandrian AS. Regadenoson induces comparable left ventricular perfusion defects as adenosine: A quantitative analysis from the ADVANCE MPI 2 Trial. J Am Coll Cardiol Img 2009;2:959-68.
82.
Zurück zum Zitat Takeishi Y, Sukekawa H, Fujiwara S, et al. Reverse redistribution of technetium-99m-sestamibi following direct PTCA in acute myocardial infarction. J Nucl Med 1996;37:1289-94.PubMed Takeishi Y, Sukekawa H, Fujiwara S, et al. Reverse redistribution of technetium-99m-sestamibi following direct PTCA in acute myocardial infarction. J Nucl Med 1996;37:1289-94.PubMed
83.
Zurück zum Zitat Weiss AT, Maddahi J, Lew AS, et al. Reverse redistribution of thallium-201: A sign of nontransmural myocardial infarction with patency of the infarct-related coronary artery. J Am Coll Cardiol 1986;7:61-7.CrossRefPubMed Weiss AT, Maddahi J, Lew AS, et al. Reverse redistribution of thallium-201: A sign of nontransmural myocardial infarction with patency of the infarct-related coronary artery. J Am Coll Cardiol 1986;7:61-7.CrossRefPubMed
84.
Zurück zum Zitat Sharir T, Kang X, Germano G, et al. Prognostic value of poststress left ventricular volume and ejection fraction by gated myocardial perfusion SPECT in women and men: Gender-related differences in normal limits and outcomes. J Nucl Cardiol 2006;13:495-506.CrossRefPubMed Sharir T, Kang X, Germano G, et al. Prognostic value of poststress left ventricular volume and ejection fraction by gated myocardial perfusion SPECT in women and men: Gender-related differences in normal limits and outcomes. J Nucl Cardiol 2006;13:495-506.CrossRefPubMed
85.
Zurück zum Zitat Hendel RC, Budoff MJ, Cardella JF, et al. ACC/AHA/ACR/ASE/ASNC/NASCI/RSNA/SAIP/SCAI/SCCT/SCMR/SIR key data elements and definitions for cardiac imaging. J Am Coll Cardiol 2009;53:91-124.CrossRefPubMed Hendel RC, Budoff MJ, Cardella JF, et al. ACC/AHA/ACR/ASE/ASNC/NASCI/RSNA/SAIP/SCAI/SCCT/SCMR/SIR key data elements and definitions for cardiac imaging. J Am Coll Cardiol 2009;53:91-124.CrossRefPubMed
86.
Zurück zum Zitat Douglas PS, Hendel RC, Cummings JE, et al. ACC/ACR/AHA/ASE/ASNC/HRS/MITA/NASCI/RSNA/SAIP/SCCT/SCMR health policy statement on structured reporting in cardiovascular imaging. J Am Coll Cardiol 2009;53:76-90.CrossRefPubMed Douglas PS, Hendel RC, Cummings JE, et al. ACC/ACR/AHA/ASE/ASNC/HRS/MITA/NASCI/RSNA/SAIP/SCCT/SCMR health policy statement on structured reporting in cardiovascular imaging. J Am Coll Cardiol 2009;53:76-90.CrossRefPubMed
87.
Zurück zum Zitat Hendel RC, Ficaro EP, Williams KA. Timeliness of reporting results of nuclear cardiology procedures. J Nucl Cardiol 2007;14:266.CrossRef Hendel RC, Ficaro EP, Williams KA. Timeliness of reporting results of nuclear cardiology procedures. J Nucl Cardiol 2007;14:266.CrossRef
Metadaten
Titel
Single photon-emission computed tomography
verfasst von
Thomas A. Holly, MD
Brian G. Abbott, MD
Mouaz Al-Mallah, MD
Dennis A. Calnon, MD
Mylan C. Cohen, MD, MPH
Frank P. DiFilippo, PhD
Edward P. Ficaro, PhD
Michael R. Freeman, MD
Robert C. Hendel, MD
Diwakar Jain, MD
Scott M. Leonard, MS, CNMT, RT(N)
Kenneth J. Nichols, PhD
Donna M. Polk, MD, MPH
Prem Soman, MD, PhD
Publikationsdatum
01.10.2010
Verlag
Springer-Verlag
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 5/2010
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-010-9246-y

Weitere Artikel der Ausgabe 5/2010

Journal of Nuclear Cardiology 5/2010 Zur Ausgabe

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Triglyzeridsenker schützt nicht nur Hochrisikopatienten

10.05.2024 Hypercholesterinämie Nachrichten

Patienten mit Arteriosklerose-bedingten kardiovaskulären Erkrankungen, die trotz Statineinnahme zu hohe Triglyzeridspiegel haben, profitieren von einer Behandlung mit Icosapent-Ethyl, und zwar unabhängig vom individuellen Risikoprofil.

Gibt es eine Wende bei den bioresorbierbaren Gefäßstützen?

In den USA ist erstmals eine bioresorbierbare Gefäßstütze – auch Scaffold genannt – zur Rekanalisation infrapoplitealer Arterien bei schwerer PAVK zugelassen worden. Das markiert einen Wendepunkt in der Geschichte dieser speziellen Gefäßstützen.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.