Skip to main content
Erschienen in: Annals of Surgical Oncology 10/2014

01.10.2014 | Breast Oncology

Localizing High-Risk Lesions for Excisional Breast Biopsy: A Comparison Between Radioactive Seed Localization and Wire Localization

verfasst von: Emilia J. Diego, MD, Atilla Soran, MD, MPH, Kandace P. McGuire, MD, Corinne Costellic, MD, Ronald R. Johnson, MD, Marguerite Bonaventura, MD, Gretchen M. Ahrendt, MD, Priscilla F. McAuliffe, MD, PhD

Erschienen in: Annals of Surgical Oncology | Ausgabe 10/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

Improved resolution and utilization of screening breast imaging has increased identification of nonpalpable high-risk lesions (HRL) and subsequent excisional breast biopsies (EBBs). Wire localization (WL), used most commonly for EBBs, may have shortcomings, including wire displacement, patient discomfort, limitations with incision planning and scheduling logistics. Radioactive seed localization (RSL) may overcome these drawbacks. The purpose of this study was to compare WL and RSL for EBBs for HRLs.

Methods

All single-site EBBs for HRL performed by four breast surgeons were retrospectively reviewed over two consecutive 1-year periods. Patients with cancer on percutaneous core biopsy (CB) were excluded. Clinicopathologic information, operative time, targeted lesion retrieval rate, and upstage rate were collected.

Results

A total of 324 EBBs for HRL were performed: 196 using WL and 128 using RSL. CB pathology was atypical hyperplasia in 56 % of WLs and 62 % of RSLs. The remaining pathologies were radial scar, papilloma, atypical papilloma or lobular carcinoma in situ. Mean age was 54 years. OR time was 27 ± 8 min for WL and 27 ± 7 min for RSL (p = 0.9). Upstage rate was 6 and 5 % for WLs and RSLs, respectively (p = 0.5). Targeted lesions were retrieved in 98 % of WL and 99 % of RSL (p = 0.5). SV was 37.2 ± 32.8 cm3 and 25.7 ± 22.3 cm3 for WL and RSL, respectively (p = 0.001).

Conclusions

RSL is comparable to WL for EBB of HRLs with similar OR times and upstage rates. SV is significantly decreased with RSL and may translate into improved cosmetic outcomes without sacrificing the diagnostic accuracy of the EBB.
Literatur
1.
Zurück zum Zitat Garcia EM, Storm ES, Atkinson L, Kenny E, Mitchell LS. Current breast imaging modalities, advances, and impact on breast care. Obstet Gynecol Clin N Am. 2013;40(3):429–457.CrossRef Garcia EM, Storm ES, Atkinson L, Kenny E, Mitchell LS. Current breast imaging modalities, advances, and impact on breast care. Obstet Gynecol Clin N Am. 2013;40(3):429–457.CrossRef
2.
Zurück zum Zitat White RR, Halperin TJ, Olson JA Jr, Soo MS, Bentley RC, Seigler HF. Impact of core-needle breast biopsy on the surgical management of mammographic abnormalities. Ann Surg. 2001;233(6):769–777.PubMedCrossRefPubMedCentral White RR, Halperin TJ, Olson JA Jr, Soo MS, Bentley RC, Seigler HF. Impact of core-needle breast biopsy on the surgical management of mammographic abnormalities. Ann Surg. 2001;233(6):769–777.PubMedCrossRefPubMedCentral
3.
Zurück zum Zitat Hall FM, Frank HA. Preoperative localization of nonpalpable breast lesions. AJR Am J Roentgenol. 1979;132(1):101–105.PubMedCrossRef Hall FM, Frank HA. Preoperative localization of nonpalpable breast lesions. AJR Am J Roentgenol. 1979;132(1):101–105.PubMedCrossRef
4.
Zurück zum Zitat Hall FM, Kopans DB, Sadowsky NL, Homer MJ. Development of wire localization for occult breast lesions: Boston remembrances. Radiology. 2013;268(3):622–627.PubMedCrossRef Hall FM, Kopans DB, Sadowsky NL, Homer MJ. Development of wire localization for occult breast lesions: Boston remembrances. Radiology. 2013;268(3):622–627.PubMedCrossRef
5.
Zurück zum Zitat Homer MJ, Pile-Spellman ER. Needle localization of occult breast lesions with a curved-end retractable wire: technique and pitfalls. Radiology. 1986;161(2):547–548.PubMedCrossRef Homer MJ, Pile-Spellman ER. Needle localization of occult breast lesions with a curved-end retractable wire: technique and pitfalls. Radiology. 1986;161(2):547–548.PubMedCrossRef
6.
Zurück zum Zitat Yagan R. Needle localization of occult breast lesions with a curved-end retractable wire: techniques and pitfalls. Radiology. 1987;163(1):284.PubMedCrossRef Yagan R. Needle localization of occult breast lesions with a curved-end retractable wire: techniques and pitfalls. Radiology. 1987;163(1):284.PubMedCrossRef
7.
Zurück zum Zitat Hughes JH, Mason MC, Gray RJ, et al. A multi-site validation trial of radioactive seed localization as an alternative to wire localization. Breast J. 2008;14(2):153–157.PubMedCrossRef Hughes JH, Mason MC, Gray RJ, et al. A multi-site validation trial of radioactive seed localization as an alternative to wire localization. Breast J. 2008;14(2):153–157.PubMedCrossRef
8.
Zurück zum Zitat Klein RL, Mook JA, Euhus DM, et al. Evaluation of a hydrogel based breast biopsy marker (HydroMARK(R)) as an alternative to wire and radioactive seed localization for non-palpable breast lesions. J Surg Oncol. 2012;105(6):591–594.PubMedCrossRef Klein RL, Mook JA, Euhus DM, et al. Evaluation of a hydrogel based breast biopsy marker (HydroMARK(R)) as an alternative to wire and radioactive seed localization for non-palpable breast lesions. J Surg Oncol. 2012;105(6):591–594.PubMedCrossRef
9.
Zurück zum Zitat Postma EL, Witkamp AJ, van den Bosch MA, Verkooijen HM, van Hillegersberg R. Localization of nonpalpable breast lesions. Expert Rev Anticancer Ther. 2011;11(8):1295–1302.PubMedCrossRef Postma EL, Witkamp AJ, van den Bosch MA, Verkooijen HM, van Hillegersberg R. Localization of nonpalpable breast lesions. Expert Rev Anticancer Ther. 2011;11(8):1295–1302.PubMedCrossRef
10.
Zurück zum Zitat Sajid MS, Parampalli U, Haider Z, Bonomi R. Comparison of radioguided occult lesion localization (ROLL) and wire localization for non-palpable breast cancers: a meta-analysis. J Surg Oncol. 2012;105(8):852–858.PubMedCrossRef Sajid MS, Parampalli U, Haider Z, Bonomi R. Comparison of radioguided occult lesion localization (ROLL) and wire localization for non-palpable breast cancers: a meta-analysis. J Surg Oncol. 2012;105(8):852–858.PubMedCrossRef
11.
Zurück zum Zitat Jakub JW, Gray RJ, Degnim AC, Boughey JC, Gardner M, Cox CE. Current status of radioactive seed for localization of non palpable breast lesions. Am J Surg. 2010;199(4):522–528.PubMedCrossRef Jakub JW, Gray RJ, Degnim AC, Boughey JC, Gardner M, Cox CE. Current status of radioactive seed for localization of non palpable breast lesions. Am J Surg. 2010;199(4):522–528.PubMedCrossRef
12.
Zurück zum Zitat Gray RJ, Salud C, Nguyen K, et al. Randomized prospective evaluation of a novel technique for biopsy or lumpectomy of nonpalpable breast lesions: radioactive seed versus wire localization. Ann Surg Oncol. 2001;8(9):711–715.PubMedCrossRef Gray RJ, Salud C, Nguyen K, et al. Randomized prospective evaluation of a novel technique for biopsy or lumpectomy of nonpalpable breast lesions: radioactive seed versus wire localization. Ann Surg Oncol. 2001;8(9):711–715.PubMedCrossRef
13.
Zurück zum Zitat McGhan LJ, McKeever SC, Pockaj BA, et al. Radioactive seed localization for nonpalpable breast lesions: review of 1,000 consecutive procedures at a single institution. Ann Surg Oncol. 2011;18(11):3096–3101.PubMedCrossRef McGhan LJ, McKeever SC, Pockaj BA, et al. Radioactive seed localization for nonpalpable breast lesions: review of 1,000 consecutive procedures at a single institution. Ann Surg Oncol. 2011;18(11):3096–3101.PubMedCrossRef
14.
Zurück zum Zitat Alderliesten T, Loo CE, Pengel KE, Rutgers EJ, Gilhuijs KG, Vrancken Peeters MJ. Radioactive seed localization of breast lesions: an adequate localization method without seed migration. Breast J. 2011;17(6):594–601.PubMedCrossRef Alderliesten T, Loo CE, Pengel KE, Rutgers EJ, Gilhuijs KG, Vrancken Peeters MJ. Radioactive seed localization of breast lesions: an adequate localization method without seed migration. Breast J. 2011;17(6):594–601.PubMedCrossRef
15.
Zurück zum Zitat Barentsz MW, van den Bosch MA, Veldhuis WB, et al. Radioactive seed localization for non-palpable breast cancer. Br J Surg. 2013;100(5):582–588.PubMedCrossRef Barentsz MW, van den Bosch MA, Veldhuis WB, et al. Radioactive seed localization for non-palpable breast cancer. Br J Surg. 2013;100(5):582–588.PubMedCrossRef
16.
Zurück zum Zitat Gobardhan PD, de Wall LL, van der Laan L, et al. The role of radioactive iodine-125 seed localization in breast-conserving therapy following neoadjuvant chemotherapy. Ann Oncol. 2013;24(3):668–673.PubMedCrossRef Gobardhan PD, de Wall LL, van der Laan L, et al. The role of radioactive iodine-125 seed localization in breast-conserving therapy following neoadjuvant chemotherapy. Ann Oncol. 2013;24(3):668–673.PubMedCrossRef
17.
Zurück zum Zitat Gray RJ, Giuliano R, Dauway EL, Cox CE, Reintgen DS. Radioguidance for nonpalpable primary lesions and sentinel lymph node(s). Am J Surg. 2001;182(4):404–406.PubMedCrossRef Gray RJ, Giuliano R, Dauway EL, Cox CE, Reintgen DS. Radioguidance for nonpalpable primary lesions and sentinel lymph node(s). Am J Surg. 2001;182(4):404–406.PubMedCrossRef
18.
Zurück zum Zitat Lovrics PJ, Goldsmith CH, Hodgson N, et al. A multicentered, randomized, controlled trial comparing radioguided seed localization to standard wire localization for nonpalpable, invasive and in situ breast carcinomas. Ann Surg Oncol. 2011;18(12):3407–3414.PubMedCrossRef Lovrics PJ, Goldsmith CH, Hodgson N, et al. A multicentered, randomized, controlled trial comparing radioguided seed localization to standard wire localization for nonpalpable, invasive and in situ breast carcinomas. Ann Surg Oncol. 2011;18(12):3407–3414.PubMedCrossRef
19.
Zurück zum Zitat Barnes G, Jr., Matory WE. Needle localization and surgical management of occult breast lesions. J Natl Med Assoc. 1989;81(6):633–636.PubMedPubMedCentral Barnes G, Jr., Matory WE. Needle localization and surgical management of occult breast lesions. J Natl Med Assoc. 1989;81(6):633–636.PubMedPubMedCentral
20.
Zurück zum Zitat Snell MJ, Ostrow LB, DuBois JJ, Boyle LM, Calfee LW. Needle-localized biopsy of occult breast lesions: an update. Mil Med. 1992;157(2):61–64.PubMed Snell MJ, Ostrow LB, DuBois JJ, Boyle LM, Calfee LW. Needle-localized biopsy of occult breast lesions: an update. Mil Med. 1992;157(2):61–64.PubMed
22.
Zurück zum Zitat Rao R, Moldrem A, Sarode V, et al. Experience with seed localization for nonpalpable breast lesions in a public health care system. Ann Surg Oncol. 2010; 17(12):3241–3246.PubMedCrossRef Rao R, Moldrem A, Sarode V, et al. Experience with seed localization for nonpalpable breast lesions in a public health care system. Ann Surg Oncol. 2010; 17(12):3241–3246.PubMedCrossRef
23.
Zurück zum Zitat Murphy JO, Moo TA, King TA, et al. Radioactive seed localization compared to wire localization in breast-conserving surgery: initial 6-month experience. Ann Surg Oncol. 2013;20(13):4121–4127.PubMedCrossRef Murphy JO, Moo TA, King TA, et al. Radioactive seed localization compared to wire localization in breast-conserving surgery: initial 6-month experience. Ann Surg Oncol. 2013;20(13):4121–4127.PubMedCrossRef
24.
Zurück zum Zitat Gray RJ, Pockaj BA, Karstaedt PJ, Roarke MC. Radioactive seed localization of nonpalpable breast lesions is better than wire localization. Am J Surg. 2004;188(4):377.PubMedCrossRef Gray RJ, Pockaj BA, Karstaedt PJ, Roarke MC. Radioactive seed localization of nonpalpable breast lesions is better than wire localization. Am J Surg. 2004;188(4):377.PubMedCrossRef
Metadaten
Titel
Localizing High-Risk Lesions for Excisional Breast Biopsy: A Comparison Between Radioactive Seed Localization and Wire Localization
verfasst von
Emilia J. Diego, MD
Atilla Soran, MD, MPH
Kandace P. McGuire, MD
Corinne Costellic, MD
Ronald R. Johnson, MD
Marguerite Bonaventura, MD
Gretchen M. Ahrendt, MD
Priscilla F. McAuliffe, MD, PhD
Publikationsdatum
01.10.2014
Verlag
Springer US
Erschienen in
Annals of Surgical Oncology / Ausgabe 10/2014
Print ISSN: 1068-9265
Elektronische ISSN: 1534-4681
DOI
https://doi.org/10.1245/s10434-014-3912-2

Weitere Artikel der Ausgabe 10/2014

Annals of Surgical Oncology 10/2014 Zur Ausgabe

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Deutlich weniger Infektionen: Wundprotektoren schützen!

08.05.2024 Postoperative Wundinfektion Nachrichten

Der Einsatz von Wundprotektoren bei offenen Eingriffen am unteren Gastrointestinaltrakt schützt vor Infektionen im Op.-Gebiet – und dient darüber hinaus der besseren Sicht. Das bestätigt mit großer Robustheit eine randomisierte Studie im Fachblatt JAMA Surgery.

Chirurginnen und Chirurgen sind stark suizidgefährdet

07.05.2024 Suizid Nachrichten

Der belastende Arbeitsalltag wirkt sich negativ auf die psychische Gesundheit der Angehörigen ärztlicher Berufsgruppen aus. Chirurginnen und Chirurgen bilden da keine Ausnahme, im Gegenteil.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.