Erschienen in:
18.03.2024 | 2023 SAGES Oral
Long-term outcomes of PGA-TMC absorbable synthetic scaffold in both clean and contaminated ventral hernia repairs
verfasst von:
Estella Y. Huang, Ryan C. Broderick, Graham J. Spurzem, Jonathan Z. Li, Rachel R. Blitzer, Joslin N. Cheverie, Bryan J. Sandler, Santiago Horgan, Garth R. Jacobsen
Erschienen in:
Surgical Endoscopy
|
Ausgabe 4/2024
Einloggen, um Zugang zu erhalten
Abstract
Background
Biosynthetic meshes afford the cost advantages of being made from fully synthetic material, but are also biodegradable, making them a versatile option that can be used in both clean and contaminated cases. The aim of this study is to evaluate the safety profile and long-term outcomes of using GORE BIO-A (BIO-A) as an adjunct to abdominal wall reconstruction in all wound classes.
Methods
A retrospective review identified patients undergoing abdominal hernia repair using BIO-A from October 2008 to June 2018. The primary outcome was hernia recurrence rate. Only patients with at least 6-month follow-up were included when looking at recurrence rates. Secondary outcomes included 30-day morbidity categorized according to CDC Surgical Site Infection Criteria, return to operating/procedure room (RTOR), 30-day readmission, length of stay (LOS), and mortality.
Results
A total of 207 patients were identified, CDC Wound Classification breakdown was 127 (61.4%), 41 (19.8%), 14 (6.8%), and 25 (12.1%) for wound classes I, II, III, and IV, respectively. Median follow-up was 55.4 months (range 0.2–162.4). Overall recurrence rate was 17.4%. Contaminated cases experienced higher recurrence rates (28.8% versus 10.4%, p = 0.002) at a mean follow up of 46.9 and 60.8 months for contaminated and clean patients, respectively. Recurrent patients had higher BMI (32.4 versus 28.4 kg/m2, p = 0.0011), larger hernias (162.2 versus 106.7 cm2, p = 0.10), higher LOS (11.1 versus 5.6 days, p = 0.0051), and higher RTOR rates (16.7% versus 5.6%, p = 0.053). 51 (24.5%) patients experienced some morbidity, including 19 (9.2%) surgical site occurences, 7 (3.4%) superficial surgical site infections, 16 (7.7%) deep surgical site infections, and 1 (0.5%) organ space infection.
Conclusion
This study affirms the use of biosynthetic mesh as a cost-effective alternative in all wound classifications, yielding good outcomes, limited long-term complications, and low recurrence.
rates.