Mapping of hepatic vasculature in potential living liver donors: comparison of gadoxetic acid-enhanced MR imaging using CAIPIRINHA technique with CT angiography

verfasst von: Kartik Jhaveri, Lijun Guo, Luís Guimarães, Ravi Menezes, Ian McGilvray, Mark Cattral, David Grant

Erschienen in: Abdominal Radiology | Ausgabe 7/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To retrospectively evaluate gadoxetic acid-enhanced magnetic resonance angiography (MRA) using controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique for mapping hepatic vascular anatomy in potential living liver donors, with CT angiography (CTA) as reference standard.

Methods

82 potential living liver donors who underwent MRA and CTA were enrolled in this HIPAA-compliant IRB-approved study. MRA and CTA images were evaluated by two reviewers in consensus with respect to (1) image quality scores for depiction of the hepatic vessels and (2) accuracy of MRA for determining the hepatic vascular variants with CTA as reference standard. The image quality scores were compared using Fisher’s exact test between MRA and CTA.

Results

The accuracy for determining the hepatic arterial, portal, and hepatic venous variants and segment IV arterial origin was 73, 90, 79, and 55%, respectively, compared to CTA. However, subjective image quality for depiction of hepatic arteries in MRA was significantly lower than CTA (p < 0.001). The portal and hepatic venous image quality was almost equal in both modalities (p = 0.059) except left hepatic vein being depicted better on CT images (p = 0.023).

Conclusion

Gadoxetic acid-enhanced MRA using CAIPIRINHA technique is feasible for mapping hepatic vasculature in potential living liver donors, with moderate accuracy for arterial variants and good to excellent results for hepatic and portal vein variants, compared with CTA. However, the specific delineation of segment IV arterial origin was possible in just over half of the liver donors with MRA.
Literatur
7.
13.
15.
Zurück zum Zitat Riffel P, Attenberger UI, Kannengiesser S, et al. (2013) Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging. Investig Radiol 48:554–561. https://doi.org/10.1097/RLI.0b013e31828654ff CrossRef Riffel P, Attenberger UI, Kannengiesser S, et al. (2013) Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging. Investig Radiol 48:554–561. https://​doi.​org/​10.​1097/​RLI.​0b013e31828654ff​ CrossRef
16.
Zurück zum Zitat Yu MH, Lee JM, Yoon JH, et al. (2013) Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging. J Magn Reson Imaging 38:1020–1026. https://doi.org/10.1002/jmri.24088 CrossRefPubMed Yu MH, Lee JM, Yoon JH, et al. (2013) Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging. J Magn Reson Imaging 38:1020–1026. https://​doi.​org/​10.​1002/​jmri.​24088 CrossRefPubMed
19.
Zurück zum Zitat Cheng YF, Chen CL, Huang TL, et al. (2001) Single imaging modality evaluation of living donors in liver transplantation: magnetic resonance imaging. Transplantation 72:1527–1533CrossRefPubMed Cheng YF, Chen CL, Huang TL, et al. (2001) Single imaging modality evaluation of living donors in liver transplantation: magnetic resonance imaging. Transplantation 72:1527–1533CrossRefPubMed
23.
Zurück zum Zitat Yoo JL, Lee CH, Park YS, et al. (2016) The short breath-hold technique, controlled aliasing in parallel imaging results in higher acceleration, can be the first step to overcoming a degraded hepatic arterial phase in liver magnetic resonance imaging: a prospective randomized control study. Investig Radiol 51:440–446. https://doi.org/10.1097/RLI.0000000000000249 CrossRef Yoo JL, Lee CH, Park YS, et al. (2016) The short breath-hold technique, controlled aliasing in parallel imaging results in higher acceleration, can be the first step to overcoming a degraded hepatic arterial phase in liver magnetic resonance imaging: a prospective randomized control study. Investig Radiol 51:440–446. https://​doi.​org/​10.​1097/​RLI.​0000000000000249​ CrossRef
24.
Zurück zum Zitat Haradome H, Grazioli L, Tsunoo M, et al. (2010) Can MR fluoroscopic triggering technique and slowrate injection provide appropriate arterial phase images with reducing artifacts on gadoxetic acid-DTPA (Gd-EOB-DTPA)-enhanced hepatic MR imaging? J Magn Reson Imaging 32:334–340. https://doi.org/10.1002/jmri.22241 CrossRefPubMed Haradome H, Grazioli L, Tsunoo M, et al. (2010) Can MR fluoroscopic triggering technique and slowrate injection provide appropriate arterial phase images with reducing artifacts on gadoxetic acid-DTPA (Gd-EOB-DTPA)-enhanced hepatic MR imaging? J Magn Reson Imaging 32:334–340. https://​doi.​org/​10.​1002/​jmri.​22241 CrossRefPubMed
28.
Zurück zum Zitat Limanond P, Raman SS, Ghobrial RM, et al. (2004) Preoperative imaging in adult-to-adult living related liver transplant donors: what surgeons want to know. J Comput Assist Tomogr 28:149–157CrossRefPubMed Limanond P, Raman SS, Ghobrial RM, et al. (2004) Preoperative imaging in adult-to-adult living related liver transplant donors: what surgeons want to know. J Comput Assist Tomogr 28:149–157CrossRefPubMed
Metadaten
Titel
Mapping of hepatic vasculature in potential living liver donors: comparison of gadoxetic acid-enhanced MR imaging using CAIPIRINHA technique with CT angiography
verfasst von
Kartik Jhaveri
Lijun Guo
Luís Guimarães
Ravi Menezes
Ian McGilvray
Mark Cattral
David Grant
Publikationsdatum
11.11.2017
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 7/2018
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-017-1379-x

Weitere Artikel der Ausgabe 7/2018

Abdominal Radiology 7/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.