Skip to main content
Erschienen in: Lasers in Medical Science 4/2010

01.07.2010 | Original Article

Microleakage and scanning electron microscopy evaluation of all-in-one self-etch adhesives and their respective nanocomposites prepared by erbium:yttrium–aluminum–garnet laser and bur

verfasst von: Yonca Korkmaz, Emre Ozel, Nuray Attar, Ceren Ozge Bicer, Erhan Firatli

Erschienen in: Lasers in Medical Science | Ausgabe 4/2010

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to evaluate the microleakage of all-in-one self-etch adhesives and their respective nanocomposites in class V cavities prepared by erbium:yttrium–aluminum–garnet (Er:YAG) laser and bur. Class V cavities were prepared on both buccal and lingual surfaces of 72 premolars by Er:YAG laser or bur and divided into six groups (n = 24). The occlusal margins were enamel and the cervical margins were cementum. The groups were as follows: group 1 Er:YAG laser preparation (E) + Xeno V (X) + CeramX (C); group 2 bur preparation (B) + X + C; group 3 E + AdheSE One (A) + Tetric EvoCeram (T); group 4 B + A + T; group 5 E + Clearfil S3 Bond (CSB) + Clearfil Majesty Esthetic (CME); group 6 B + CSB + CME. All teeth were stored in distilled water at 37°C for 24 h, then thermocycled 500 times (5–55°C). Ten teeth from each group were chosen for the microleakage investigation and two teeth for the scanning electron microscopy (SEM) evaluation. The teeth that were prepared for the microleakage test were immersed in 0.5% basic fuchsin dye for 24 h. After immersion, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed by Kruskal–Wallis and Mann–Whitney U tests (P < 0.05). Bur-prepared cavities presented less microleakage in all groups for enamel (P < 0.05); however, in cervical margins, there were no differences between laser-prepared and bur-prepared cavities in the Xeno V + CeramX and AdheSE One + Tetric EvoCeram groups (P > 0.05). SEM observations of restorative material–dentin interfaces seemed to correspond with those of the microleakage test. Microleakage at the cervical interfaces was greater than that at the occlusal interfaces. Er:YAG laser-prepared class V cavities yielded more microleakage in occlusal margins with all-in-one self-etch adhesives and the respective manufacturer’s nanocomposites.
Literatur
1.
Zurück zum Zitat Mitra SB, Wu D, Holmes BN (2003) An application of nanotechnology in advanced dental materials. J Am Dent Assoc 134:1382–1390PubMed Mitra SB, Wu D, Holmes BN (2003) An application of nanotechnology in advanced dental materials. J Am Dent Assoc 134:1382–1390PubMed
2.
Zurück zum Zitat Van Meerbeek B, De Munck J, Yoshida Y, Inoue S, Vargas M, Vijay P, Van Landuyt K, Lambrechts P, Vanherle G (2003) Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges. Oper Dent 28:215–235PubMed Van Meerbeek B, De Munck J, Yoshida Y, Inoue S, Vargas M, Vijay P, Van Landuyt K, Lambrechts P, Vanherle G (2003) Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges. Oper Dent 28:215–235PubMed
3.
Zurück zum Zitat Perdigão J, Geraldeli S, Hodges JS (2003) Total-etch versus self-etch adhesive. Effect on postoperative sensitivity. J Am Dent Assoc 134:1621–1629PubMed Perdigão J, Geraldeli S, Hodges JS (2003) Total-etch versus self-etch adhesive. Effect on postoperative sensitivity. J Am Dent Assoc 134:1621–1629PubMed
4.
Zurück zum Zitat Attar N, Korkmaz Y (2007) Effect of two light-emitting diode (LED) and one halogen curing light on the microleakage of class V flowable composite restorations. J Contemp Dent Pract 8:80–88PubMed Attar N, Korkmaz Y (2007) Effect of two light-emitting diode (LED) and one halogen curing light on the microleakage of class V flowable composite restorations. J Contemp Dent Pract 8:80–88PubMed
6.
Zurück zum Zitat Miyazaki S, Iwasaki K, Onose H, Moore BK (2001) Enamel and dentin bond strengths of single application bonding systems. Am J Dent 14:361–366PubMed Miyazaki S, Iwasaki K, Onose H, Moore BK (2001) Enamel and dentin bond strengths of single application bonding systems. Am J Dent 14:361–366PubMed
7.
Zurück zum Zitat Leinfelder KF, Kurdziolek SM (2003) Self-etching bonding agents. Compend Contin Educ Dent 24:447–454PubMed Leinfelder KF, Kurdziolek SM (2003) Self-etching bonding agents. Compend Contin Educ Dent 24:447–454PubMed
8.
Zurück zum Zitat Perdigão J, Anauate-Netto C, Carmo AR, Lewgoy HR, Cordeiro HJ, Dutra-Corrêa M, Castilhos N, Amore R (2004) Influence of acid etching and enamel beveling on the 6-month clinical performance of a self-etch dentin adhesive. Compend Contin Educ Dent 25:33–34, 36–38, 40 Perdigão J, Anauate-Netto C, Carmo AR, Lewgoy HR, Cordeiro HJ, Dutra-Corrêa M, Castilhos N, Amore R (2004) Influence of acid etching and enamel beveling on the 6-month clinical performance of a self-etch dentin adhesive. Compend Contin Educ Dent 25:33–34, 36–38, 40
9.
Zurück zum Zitat Christensen GJ (2002) Preventing postoperative tooth sensitivity in class I, II and V restorations. J Am Dent Assoc 133:229–231PubMed Christensen GJ (2002) Preventing postoperative tooth sensitivity in class I, II and V restorations. J Am Dent Assoc 133:229–231PubMed
10.
Zurück zum Zitat Eick JD, Gwinnett AJ, Pashley DH, Robinson SJ (1997) Current concepts on adhesion to dentin. Crit Rev Oral Biol Med 8:306–335CrossRefPubMed Eick JD, Gwinnett AJ, Pashley DH, Robinson SJ (1997) Current concepts on adhesion to dentin. Crit Rev Oral Biol Med 8:306–335CrossRefPubMed
12.
Zurück zum Zitat Swift EJ Jr (2002) Dentin/enamel adhesives: review of the literature. Pediatr Dent 24:456–461PubMed Swift EJ Jr (2002) Dentin/enamel adhesives: review of the literature. Pediatr Dent 24:456–461PubMed
13.
Zurück zum Zitat Walshaw PR, McComb D (1996) Clinical considerations for optimal dentinal bonding. Quintessence Int 27:619–625PubMed Walshaw PR, McComb D (1996) Clinical considerations for optimal dentinal bonding. Quintessence Int 27:619–625PubMed
15.
Zurück zum Zitat Gokcelik A, Ozel Y, Ozel E, Arhun N, Attar N, Firatli S, Firatli E (2007) The influence of Er:YAG laser conditioning versus self-etching adhesives with acid etching on the shear bond strength of orthodontic brackets. Photomed Laser Surg 25:508–512. doi:10.1089/pho.2007.2096 CrossRefPubMed Gokcelik A, Ozel Y, Ozel E, Arhun N, Attar N, Firatli S, Firatli E (2007) The influence of Er:YAG laser conditioning versus self-etching adhesives with acid etching on the shear bond strength of orthodontic brackets. Photomed Laser Surg 25:508–512. doi:10.​1089/​pho.​2007.​2096 CrossRefPubMed
16.
Zurück zum Zitat Cozean C, Arcoria CJ, Pelagalli J, Powell GL (1997) Dentistry for the 21st century? Erbium:YAG laser for teeth. J Am Dent Assoc 128:1080–1087PubMed Cozean C, Arcoria CJ, Pelagalli J, Powell GL (1997) Dentistry for the 21st century? Erbium:YAG laser for teeth. J Am Dent Assoc 128:1080–1087PubMed
19.
Zurück zum Zitat Aranha AC, Turbino ML, Powell GL, Eduardo Cde P (2005) Assessing microleakage of class V resin composite restorations after Er:YAG laser and bur preparation. Lasers Surg Med 37:172–177. doi:10.1002/lsm.20208 CrossRefPubMed Aranha AC, Turbino ML, Powell GL, Eduardo Cde P (2005) Assessing microleakage of class V resin composite restorations after Er:YAG laser and bur preparation. Lasers Surg Med 37:172–177. doi:10.​1002/​lsm.​20208 CrossRefPubMed
21.
Zurück zum Zitat Korkmaz Y, Ozel E, Attar N (2007) Effect of flowable composite lining on microleakage and internal voids in class II composite restorations. J Adhes Dent 9:189–194PubMed Korkmaz Y, Ozel E, Attar N (2007) Effect of flowable composite lining on microleakage and internal voids in class II composite restorations. J Adhes Dent 9:189–194PubMed
23.
Zurück zum Zitat Sidhu SK, Henderson LJ (1992) In vitro marginal leakage of cervical composite restorations lined with a light-cured glass ionomer. Oper Dent 17:7–12PubMed Sidhu SK, Henderson LJ (1992) In vitro marginal leakage of cervical composite restorations lined with a light-cured glass ionomer. Oper Dent 17:7–12PubMed
25.
Zurück zum Zitat Ozel E, Korkmaz Y, Attar N (2008) Influence of location of the gingival margin on the microleakage and internal voids of nanocomposites. J Contemp Dent Pract 9:65–72PubMed Ozel E, Korkmaz Y, Attar N (2008) Influence of location of the gingival margin on the microleakage and internal voids of nanocomposites. J Contemp Dent Pract 9:65–72PubMed
26.
Zurück zum Zitat Asmussen E, Jorgensen KD (1978) Restorative resins: coefficient of thermal expansion—a factor of clinical significance? Quintessence Int Dent Dig 9:79–82PubMed Asmussen E, Jorgensen KD (1978) Restorative resins: coefficient of thermal expansion—a factor of clinical significance? Quintessence Int Dent Dig 9:79–82PubMed
27.
Zurück zum Zitat Chinelatti MA, Ramos RP, Chimello DT, Borsatto MC, Pécora JD, Palma-Dibb RG (2004) Influence of the use of Er:YAG laser for cavity preparation and surface treatment in microleakage of resin-modified glass ionomer restorations. Oper Dent 29:430–436PubMed Chinelatti MA, Ramos RP, Chimello DT, Borsatto MC, Pécora JD, Palma-Dibb RG (2004) Influence of the use of Er:YAG laser for cavity preparation and surface treatment in microleakage of resin-modified glass ionomer restorations. Oper Dent 29:430–436PubMed
28.
Zurück zum Zitat De Munck J, Van Meerbeek B, Satoshi I, Vargas M, Yoshida Y, Armstrong S, Lambrechts P, Vanherle G (2003) Microtensile bond strengths of one- and two-step self-etch adhesives to bur-cut enamel and dentin. Am J Dent 16:414–420PubMed De Munck J, Van Meerbeek B, Satoshi I, Vargas M, Yoshida Y, Armstrong S, Lambrechts P, Vanherle G (2003) Microtensile bond strengths of one- and two-step self-etch adhesives to bur-cut enamel and dentin. Am J Dent 16:414–420PubMed
30.
Zurück zum Zitat Perdigao J, Gomes G, Duarte S Jr, Lopes MM (2005) Enamel bond strengths of pairs of adhesives from the same manufacture. Oper Dent 30:492–499PubMed Perdigao J, Gomes G, Duarte S Jr, Lopes MM (2005) Enamel bond strengths of pairs of adhesives from the same manufacture. Oper Dent 30:492–499PubMed
31.
Zurück zum Zitat Van Landuyt KL, De Munck J, Snauwaert J, Coutinho E, Poitevin A, Yoshida Y, Inoue S, Peumans M, Suzuki K, Lambrechts P, Van Meerbeek B (2005) Monomer-solvent phase separation in one-step self-etch adhesives. J Dent Res 84:183–188CrossRefPubMed Van Landuyt KL, De Munck J, Snauwaert J, Coutinho E, Poitevin A, Yoshida Y, Inoue S, Peumans M, Suzuki K, Lambrechts P, Van Meerbeek B (2005) Monomer-solvent phase separation in one-step self-etch adhesives. J Dent Res 84:183–188CrossRefPubMed
34.
Zurück zum Zitat Korkmaz Y, Attar N (2007) Dentin bond strength of composites with self-etching adhesives using LED curing lights. J Contemp Dent Pract 8:34–42PubMed Korkmaz Y, Attar N (2007) Dentin bond strength of composites with self-etching adhesives using LED curing lights. J Contemp Dent Pract 8:34–42PubMed
36.
Zurück zum Zitat Niu W, Eto JN, Kimura Y, Takeda FH, Matsumoto K (1998) A study on microleakage after resin filling of class V cavities prepared by Er:YAG laser. J Clin Laser Med Surg 16:227–231PubMed Niu W, Eto JN, Kimura Y, Takeda FH, Matsumoto K (1998) A study on microleakage after resin filling of class V cavities prepared by Er:YAG laser. J Clin Laser Med Surg 16:227–231PubMed
37.
Zurück zum Zitat Hatibovic-Kofman S, Wright GZ, Braverman I (1998) Microleakage of sealants after conventional, bur, and air-abrasion preparation of pits and fissures. Pediatr Dent 20:173–176PubMed Hatibovic-Kofman S, Wright GZ, Braverman I (1998) Microleakage of sealants after conventional, bur, and air-abrasion preparation of pits and fissures. Pediatr Dent 20:173–176PubMed
39.
Zurück zum Zitat Corona SA, Borsatto M, Dibb RG, Ramos RP, Brugnera A, Pécora JD (2001) Microleakage of class V resin composite restorations after bur, air-abrasion or Er:YAG laser preparation. Oper Dent 26:491–497PubMed Corona SA, Borsatto M, Dibb RG, Ramos RP, Brugnera A, Pécora JD (2001) Microleakage of class V resin composite restorations after bur, air-abrasion or Er:YAG laser preparation. Oper Dent 26:491–497PubMed
40.
Zurück zum Zitat Setien VJ, Cobb DS, Denehy GE, Vargas MA (2001) Cavity preparation devices: effect on microleakage of class V resin-based composite restorations. Am J Dent 14:157–162PubMed Setien VJ, Cobb DS, Denehy GE, Vargas MA (2001) Cavity preparation devices: effect on microleakage of class V resin-based composite restorations. Am J Dent 14:157–162PubMed
41.
Zurück zum Zitat Wright GZ, McConnell RJ, Keller U (1993) Microleakage of class V composite restorations prepared conventionally with those prepared with an Er:YAG laser: a pilot study. Pediatr Dent 15:425–426PubMed Wright GZ, McConnell RJ, Keller U (1993) Microleakage of class V composite restorations prepared conventionally with those prepared with an Er:YAG laser: a pilot study. Pediatr Dent 15:425–426PubMed
42.
Zurück zum Zitat Palma Dibb RG, Milori Corona SA, Borsatto MC, Ferreira KC, Pereira Ramos R, Djalma Pécora J (2002) Assessing microleakage on class V composite resin restorations after Er:YAG laser preparation varying the adhesive systems. J Clin Laser Med Surg 20:129–133. doi:10.1089/104454702760090209 CrossRefPubMed Palma Dibb RG, Milori Corona SA, Borsatto MC, Ferreira KC, Pereira Ramos R, Djalma Pécora J (2002) Assessing microleakage on class V composite resin restorations after Er:YAG laser preparation varying the adhesive systems. J Clin Laser Med Surg 20:129–133. doi:10.​1089/​1044547027600902​09 CrossRefPubMed
43.
Zurück zum Zitat Ceballo L, Toledano M, Osorio R, Tay FR, Marshall GW (2002) Bonding to Er-YAG-laser-treated dentin. J Dent Res 81:119–122CrossRefPubMed Ceballo L, Toledano M, Osorio R, Tay FR, Marshall GW (2002) Bonding to Er-YAG-laser-treated dentin. J Dent Res 81:119–122CrossRefPubMed
45.
Zurück zum Zitat Sano H, Takatsu T, Ciucchi B, Horner JA, Matthews WG, Pashley DH (1995) Nanoleakage: leakage within the hybrid layer. Oper Dent 20:18–25PubMed Sano H, Takatsu T, Ciucchi B, Horner JA, Matthews WG, Pashley DH (1995) Nanoleakage: leakage within the hybrid layer. Oper Dent 20:18–25PubMed
46.
Zurück zum Zitat Roebuck EM, Sauders WP, Whitters CJ (2000) Influence of erbium:YAG laser energies on the microleakage of class V resin-based composite restorations. Am J Dent 13:280–284PubMed Roebuck EM, Sauders WP, Whitters CJ (2000) Influence of erbium:YAG laser energies on the microleakage of class V resin-based composite restorations. Am J Dent 13:280–284PubMed
48.
Zurück zum Zitat Prati C, Chersoni S, Mongiorgi R, Pashley DH (1998) Resin-infiltrated dentin layer formation of new bonding systems. Oper Dent 23:185–194PubMed Prati C, Chersoni S, Mongiorgi R, Pashley DH (1998) Resin-infiltrated dentin layer formation of new bonding systems. Oper Dent 23:185–194PubMed
Metadaten
Titel
Microleakage and scanning electron microscopy evaluation of all-in-one self-etch adhesives and their respective nanocomposites prepared by erbium:yttrium–aluminum–garnet laser and bur
verfasst von
Yonca Korkmaz
Emre Ozel
Nuray Attar
Ceren Ozge Bicer
Erhan Firatli
Publikationsdatum
01.07.2010
Verlag
Springer-Verlag
Erschienen in
Lasers in Medical Science / Ausgabe 4/2010
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-009-0672-5

Weitere Artikel der Ausgabe 4/2010

Lasers in Medical Science 4/2010 Zur Ausgabe